calorimeter heat flow calorimetry, power compensation calorimetry

Similar documents
Atlas Syringe Pump XL

Perseverance. Experimentation. Knowledge.

nanoparticles automated systems for nanoparticle synthesis Syrris - High quality, control and precision in nanochemistry

Applications of the Micro Reaction Calorimeter

High Pressure Chemistry. Hydrogenation & Catalysis Tools.

High-Performance Continuous Flow Chemistry Systems. Robust Accurate Flexible Safe

MultiMax Application Note

Titrex ACT titrators have been designed to simply and precisely satisfy and perform the widest range of potentiometric titrations: acid-base, redox,

LABOTRON EXTRACTION & SYNTHESIS 2450 MHz

Automatic titrators, TitroMatic

RECORD AND ANALYSE THE PRESSURE-ENTHALPY DIAGRAM FOR A COMPRESSION HEAT PUMP

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

SOPHISTICATED DESIGN, INTUITIVE OPERATION, RESEARCH-GRADE RESULTS

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

THE VERSATILE VSP2: A TOOL FOR ADIABATIC THERMAL ANALYSIS AND VENT SIZING APPLICATIONS

The THT micro reaction calorimeter RC

THE USE OF DEWAR CALORIMETRY IN THE ASSESSMENT OF CHEMICAL REACTION HAZARDS

Experiment 24. Chemical recycling of poly(ethylene) terephthalate (PET)

CHEMICAL REACTORS TEACHING EQUIPMENT CEXC

The THT micro reaction calorimeter μrc

Our Drop Counter sensor now features housing for two electrode sensors, an anti-twist mechanism, an indicator LED and two cable guides.

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

CHEMICAL ENGINEERING LABORATORY CHEG 4137W/4139W. Reaction Kinetics Saponification of Isopropyl Acetate with Sodium Hydroxide

Thermochemistry/Calorimetry. Determination of the enthalpy of vaporization of liquids LEC 02. What you need: What you can learn about

Microscopy Cryostat System

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Contact Us. Syrris network of offices in the UK, USA, Japan, India and Brazil plus over 35 distributors worldwide offer local service and support.

SOPHAS - Speeding up the process of discovery and optimisation

The White Paper* of Reaction Calorimetry

Coflore Agitated Cell Reactor

Name Group # Date Partners. Specific Heat and Calorimetry

INSTRUCTOR RESOURCES

473-SHX Dew Point Mirror

Hess' Law: Calorimetry

VISIMIX TURBULENT. TACKLING SAFETY PROBLEMS OF STIRRED REACTORS AT THE DESIGN STAGE.

55 Acid base titration: Polyprotic acids, determination of the molar concentration of phosphoric acid in cola

Micro Reaction Calorimeter

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

LABORATORY LINE. REACTRON RT 1 and RT 2. Reaction and mixing processes at a laboratory level, modular design laboratory reactors

Experiment C-10 Titration of a Strong Acid and a Strong Base

Metz Syn 10 Reaction Station

Avoid Batch Failures via Scale Down Simulation of Exothermic Reactions in the Lab

Getting started with BatchReactor Example : Simulation of the Chlorotoluene chlorination

C80. Calvet Calorimeter From ambient to 300 C. A trademark of KEP Technologies group

IMPROVED ADIABATIC CALORIMETRY IN THE PHI-TEC APPARATUS USING AUTOMATED ON-LINE HEAT LOSS COMPENSATION

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

The Vacuum Sorption Solution

Acid-Base Titration. Sample

data sheet DONATELLO FAST General characteristics Rev. First emission - 01/07/ PRO02 code

Dewpoint Meter Data Sheet / Instructions

Process Safety. Process Safety and Hazard Assessment Avoiding Incidents in the Lab and in the Plant

Spectrometer User s Guide

Temperature control for Varian Cary line of UV/Vis Spectrophotometers and the Eclipse Fluorometer

38 Acid base titration: Polyprotic acids, determination of the molar concentration of phosphoric acid in cola

next generation Welcome to the Dispersion options Smarter particle sizing Your sample, expertly processed and prepared Particle size

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

Data Sheet / Instructions. Dewpoint MeterO

Supporting Information. Flow Grignard and Lithiation: Screening Tools and Development of Continuous Processes

Total Carboxylic Acid Group Content Applicable Products: Carbopol * Polymers and Pemulen * Polymeric Emulsifiers

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

Water & Vapor Sorption

473 Dew Point Hygrometer

ASTORIA PACIFIC. Automated Wet-Chemistry Analyzers and Diagnostic Reagents. rapid-t

Development of an organometallic flow chemistry. reaction at pilot plant scale for the manufacture of

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

The analysis of organic acid content of additives, premix, feed, and water.

Heat of Solution for Aqueous Potassium Nitrate

CHEMICAL REACTION ENGINEERING LAB

Experiment C-15 Distillation - part 1

# 12 ph-titration of Strong Acids with Strong Bases

FlowSyn The Continuous Flow Reactor from Uniqsis Designed by chemists for chemists

Investigation of adiabatic batch reactor

Standardizing a Solution of Sodium Hydroxide. Evaluation copy

Freezing point depression (Item No.: P )

1. Starting of a project and entering of basic initial data.

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

High Pressure DSC Differential Scanning Calorimeter

Reaction Calorimetry as a Tool in Process Development, Research and Safety Analysis

Analysing Phenol-Formaldehyde Resin Reaction For Safe Process Scale Up

cobas c 111 analyzer Big analyzer performance in a small package

Thermochemistry: Calorimetry and Hess s Law

INNOVATIVE ENGINEERING FOR SIMPLE OPERATION

C q T q C T. Heat is absorbed by the system H > 0 endothermic Heat is released by the system H < 0 exothermic

Lab 5 Enthalpy of Solution Formation

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

CHEMISTRY 135 General Chemistry II. Energy of Phase Changes [1]

Automated multi-vapor gravimetric sorption analyzer for advanced research applications

Dielectric Analysis of Insulation Liquids

CONSTANT PRESSURE CALORIMETRY: A STUDY OF GLYCINE PROTON-TRANSFER ENTHALPIES 1

Karl-Fischer Titration the method for determining water

Titration of a strong acid with a strong base with Cobra4

FlowCAT a versatile continuous flow reactor system focusing on reactions under elevated pressure and/or involving heterogeneous catalysis.

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Lab Report. Dystan Medical Company - Cold Packs and Hot Packs. Colin Hancock. Wolfgang Allred #202

CuBiAn XC C u l t u r e B i o c h e m i s t r y a n a l y z e r extra compact

Scale-up problems are often perceived as difficult. Here the reaction calorimetry has proven to be

CEO LETTER. - Rolf Ludwig

473 Dew Point Hygrometer

ph Titration Curves You will need about 10 ml of ~6M NaOH solution and about 40 ml of each acid solution and about 1.5 grams of KHP.

THE ENERGY OF PHASE CHANGES

Transcription:

calorimeter heat flow calorimetry, power compensation calorimetry Atlas simply does it all

What is the Atlas Reaction Calorimeter? The Atlas Reaction Calorimeter accurately measures the power and enthalpy of chemical reactions. This provides information such as reaction kinetics and safety data that is invaluable in process optimization, scale-up and hazard analysis. Atlas Calorimeter Specification Interchangeable jacketed reaction vessels Temperature range 100ml, 250ml, 500ml, 1 litre and 2 litre vacuum jacketed reactors available with a range of profiles including round, torispherical, conical or custom. -40 C to 150 C recommended for calorimetry (up to 200 C possible). Accuracy Typically 1 to 5% (dependent on settling time and external conditions). Calorimetric techniques Heat flow calorimetry (HFC) or power compensation calorimetry (PCC). used Footprint Chemical resistance Maximum reaction power Safety features Stirring options Circulator options Equipment supplied Dosing options Other sensor options From 40cm (16 ) wide. Glass, PTFE and other fluoropolymers. 100W/litre maximum (50W for power compensation calorimetry). Warnings, alarms and automatic shutdown can be set for the whole experiment and each process step. Anchor, pitched blade propeller, retreat curve impeller or custom made in glass or PTFE. 0-800RPM (up to 11Ncm) or 0-1000RPM (up to 90Ncm) with torque feedback. Julabo, Huber, Lauda, Haake Standard Atlas Potassium System, plus: Atlas PC Software Atlas Calorimetry Software Upgrade and Atlas Reporting Software Atlas Port for recirculator control Vacuum jacketed vessel (see above) Fast response reaction temperature probe T j (jacket in) measurement probe with node and insulated cover PC controlled heater power supply with Atlas Port Reactor heater Manual dosing, Atlas Syringe Pump for automatic volumetric dosing or peristaltic pump and balance for gravimetric dosing. ph, in-situ FTIR sensor, turbidity, pressure, etc.

Benefits and Applications The Atlas Reaction Calorimeter has the following benefits: Fully automated Excellent control Accurate Walk away operation Wide temperature and pressure range Easy analysis Quick to set up Flexible Safe Compact Atlas Reaction Calorimeter has the following applications: Above: Quick response RTD probe measures the temperature of the jacket (Tj) Process development Safety Kinetic studies Scale-up Parallel chemistry Process optimization End point detection Left: Heat Flow Calorimetry configuration with gravimetric dosing

The Atlas Calorimeter System The Atlas Calorimeter system allows reactors of 100ml, 250ml, 500ml, 1L or 2L to be interchanged in under a minute. All sensors, stirrers, pumps, etc. are automatically detected and easily controlled, allowing quick upgrade of functionality. Options include automated liquid addition, pressure reactions, and sensors such as ph, turbidity or in situ FTIR. Atlas Calorimeter Options Quick Connect Stirrer Automatically aligning overhead stirrer drive clicks into place without tools. Atlas Calorimeter Options PC control The Atlas Software will generate power and enthalpy graphs with the click of a button. Reporting Software enables graphical analysis of log files. Quick Response RTD Probe FEP coated RTD probe in various sizes to suit all vessels. FTIR Analysis The addition of a Bruker Matrix Spectrophotometer allows the Atlas Calorimeter to be upgraded to include FTIR analysis. Temperature Node Allows RTD probes to be connected to the Base Unit and displayed on the front panel. Turbidity Sensing The addition of an Atlas Turbidity Node and Probe allows the Atlas Calorimeter to be upgraded to include Turbidity sensing. Quick Connect Pipes and Insulators Reduces condensation and/or ice build-up at connections to help maintain accurate Tj. Quick Vessel Clamp Allows vessels to be changed in under a minute. High Pressure The addition of a pressure vessel with valves, cooling coils, burst disc and various other components allows the Atlas Calorimeter to be upgraded for high pressure applications. Heater Rod FEP coated heater rod for HFC and PCC. RTD Stainless Steel Probe Accurately monitors the temperature of the jacket Atlas Syringe Pump Enables automated volumetric dosing Vacuum Jacketed Vessel Offers excellent insulation and available in 100, 250, 500, 1000 and 2000ml. Various Stirrers Choice of anchor (pictured), propeller pitched blade, retreat curve impeller or custom made. Power Supply Delivers power to the heater rod for heat flow and power compensation calorimetry. ph Monitoring The addition of an Atlas ph and Temperature Node and Probe allows the Atlas Calorimeter to be upgraded to include ph monitoring. USB Download Download data to USB stick High Torque Stirring The addition of a Heidolph Stirrer and Heidolph stirrer adaptor kit allows the Atlas Calorimeter to be upgraded for applications that require high torque stirring. Gravimetric Dosing The addition of a balance and a peristaltic pump allows the Atlas Calorimeter to be upgraded to include gravimetric dosing.

Heat Flow and Power Compensation Calorimetry The Atlas Calorimeter has been designed so heat flow calorimetry (HFC) and power compensation calorimetry (PCC) are performed with the same equipment, allowing a choice of methods for the reaction. Heat Flow Calorimetry (HFC) or Power Compensation Calorimetry (PCC)? HFC is generally used for reactions where the heater may have an effect on the chemistry, since the dip in heater is not used during the reaction. HFC is also preferred when large exotherms are expected. PCC is used where quicker results are required, since no pre and post calibration is required. Data can be shown in real time with both methods using Atlas. Power Compensation Calorimetry (PCC) PCC provides a very direct method for measuring process power and enthalpy. The reactor runs isothermally with the jacket set at a constant temperature below the desired reaction temperature. The temperature offset is maintained by the addition of power. The energy input is adjusted continuously by the Atlas Software to maintain the reactor contents at the desired temperature. PCC determines the heat of reaction by monitoring the power supplied to a compensation heater placed in the reactor (above). Heat Flow Calorimetry (HFC) HFC determines the heat flow into or out of the system by measurement of the temperature difference between the vessel jacket and the reactor. The reactor temperature is controlled isothermally at all times by modulating the jacket temperature and the difference between the reactor temperature and the jacket temperature is monitored. Data is gathered by measuring the difference between reactor temperature (Tr) and jacket temperature (Tj). The result (Tr-Tj) is a measure of the heat flow between the reactor and the jacket, is directly proportional to the actual power and is automatically calibrated before and/or after the experiment. Why use the Atlas Calorimeter? Accurate A major (top three) pharmaceutical company independently tested the Atlas Calorimeter System using heat flow calorimetry (HFC) and power compensation calorimetry (PCC). They performed a range of endothermic and exothermic processes. The results of the experiments are shown below. Real time data with no extra effort Reaction calorimetry is a non-intrusive, nondestructive, real time technique that yields valuable process data. Historically, reaction calorimeters were too expensive, too difficult to operate or too slow to set up. The Atlas Calorimeter generates calorimetry data with the same effort required to run a regular experiment. Independent Data Experiment name Literature value H (kj/mole) Atlas value H (kj/mole) Atlas Calorimeter technique used Accuracy Sensible heat of addition1 +6.06 +5.91 PCC 97.5% Hydrolysis of Ac 2O in H 2O2-56.6-54.1 PCC 95.6% Dissolution of NaOH in H2O 3-44.51-44.51 HFC 100% Hydrolysis of Ac 2O in H 2O 2-56.6-53.51 HFC 94.5% 1 50ml of H2O added to 150ml of H2O at 50 C over 10 minutes 2 16g of Acetic anhydride added to 200ml of H 2O 50 C over 10 minutes 3 15g of Sodium hydroxide pellets added in one portion to 150ml of H 2O at 25 C

Reaction Calorimetry has Never Been so Simple The Atlas Calorimeter is designed for ease of use. Setting up a system, running an experiment with software and then analysing the data using the innovative Atlas Reporting Software are all made easy with the Atlas Calorimeter. Set-up System The standard hardware required for a power compensation calorimetry (PCC) system and a heat flow calorimetry (HFC) system is the same. All parts can be put together quickly and easily without the need for tools. Mechanical connections click firmly into place and electronic connections such as sensors and pumps are detected automatically. The Atlas system connects to the PC by a USB cable. Define Experiment The Atlas Software has been designed to make defining, running and processing data from experiments, quick and easy. Defining an experiment could not be more simple. The drag and drop interface allows you to select the modules you want to use, e.g. circulator, power supply, temperature probe, etc. and add them to your experiment apparatus. From here you can easily define the desired calorimetry method (PCC or HFC), reaction temperature, quantity and rate of reagents to be dosed and experiment time, etc. Run Experiment When running the experiment, everything is controlled automatically including stabilization at desired reaction temperature, reagent addition and in the case of HFC, pre and/or post run calibration (no user intervention is required during the entire process). All data is continually logged to a common csv file and displayed by the software in graph format in real time. Real time analysis is made easy by the Atlas Software featuring single click plotting of power and enthalpy. Comments can be added and the experiment paused and restarted during the process. Process Data Processing data is simple with the Atlas Reporting Software which enables log files generated by Atlas Calorimetry Software to be interpreted quickly. The software s wizard style interface allows fast and effective analysis of the thermal properties of the reaction with the click of a button. The Software imports raw data and automatically corrects for the sensible heat of addition and changes in UA. Graphs of reaction power/enthalpy, overall process enthalpy, and sensible heat of addition are instantly displayed with other process data such as additions. Above: Atlas Reporting Software graphically displaying calorimetric data Far left: Reaction control with PC software Left: Analyse power and enthalpy data with Reporting Software

Atlas - The Best Value Process Reactor in the World! The Atlas Calorimeter is one product within the Atlas range of automated reactor systems. Atlas is a series of high performance, easy to use modular products. Options include ph control, volumetric or gravimetric dosing, high pressure, FTIR analysis and crystallization in flasks, vials or jacketed reactors. Atlas Benefits Easy to use: Twist & click knob, large display and intuitive. Automated reactions without PC control: Set points, ramps or sophisticated profiles are all possible for reaction temperature and stirrer speed. Automatic data capture: Data such as temperatures and stirrer speed are logged in a.csv file and can be downloaded to a USB stick. Easy to upgrade to perform: Calorimetry, ph control, gravimetric or volumetric reagent addition, crystallizations, parallel reactions, etc. High performance stirring: 1200RPM magnetic or 800RPM powerful overhead stirrer. Quick: Everything clicks together quickly and easily without tools. Change vessels in under a minute. Small footprint: 23cm (9 ) square easily fits in fume cupboards. Robust: Specifically designed for use in chemical laboratories. Syrris Ltd. Unit 1, Anglian Business Park, Orchard Road Royston, Hertfordshire, SG8 5TW, United Kingdom T: +44 (0)1763 242555 F: +44 (0)1763 246125 Syrris Inc. (North America) 29 Albion Place Charlestown, MA 02129 T: 617 848 2997 F: 617 532 1033 Syrris Japan, Inc. SOHO Station 202 24-8, Yamashita-cho, Naka-ku, Yokohama, Japan 231-00231 T: 078 919 5909 E: info@syrris.co.jp W: www.syrris.co.jp Syrris India. 420 / 421, Corporate Avenue, Sonawala Road, Goregaon, East Mumbai 400 063 T: +91 22 2686 4410 Syrris Brasil. São Paulo SP Brasil T: +55 11 6185 0883