Total Organic Carbon, Total Nitrogen

Similar documents
Fusion UV/Persulfate TOC Analyzer

SKALAR. your partner in chemistry automation. Formacs series Total Organic Carbon & Total Nitrogen Analyzers

Fusion UV/Persulfate TOC Analyzer

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

Total Organic Carbon Analysis of Solid Samples for Environmental and Quality Control Applications

United States EPA Method 415.3

SKALAR. your partner in chemistry automation. Primacs SNC Total Carbon and Total Nitrogen Analyzer

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

SKALAR. your partner in chemistry automation. Primacs SN Protein-Nitrogen Analyzer

Organic Carbon, Total (Low Level) (UV Promoted, Persulfate Oxidation) CAS # Total Organic Carbon TOC C

2. Pharmaceutical industry

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Oxygen Demand, Chemical

Advanced technics in the. (TIC/TOC/TNb)

Persulfate Digestion Method Method to 25.0 mg/l N (LR) Test N Tube Vials

Persulfate Digestion Method Method to 150 mg/l N (HR) Test N Tube Vials

Basic Digestion Principles

Examining the Role of TOC Analyzers in the Pharmaceutical Laboratory

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Chemical Oxidation Oxidizing agents

Standard Operating Procedure for the Analysis of Dissolved Inorganic Carbon CCAL 21A.1

Oxygen Demand, Chemical

USGS District Laboratory, Troy, NY Dissolved Inorganic Carbon Analysis Standard Operating Procedure

Persulfate Digestion Method Method to 40 mg/l N (HR) TNTplus 827

2. Pharmaceutical industry

TRL-TOC-M MODEL MODULAR TC/IC/TOC/TN ANALYZER FOR LIQUID AND SOLID SAMPLES. TRL-TOC-M Model TC/IC/TOC/TN Analyzers are designed to handle:

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

The. Family of Mercury Analyzers. Hydra II AA Atomic Absorption Detection Liquid Samples

Ground Water & UST Samples: Containers, Preservation and Hold Times Table

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

Hydra-C Application Note: 1076

METHOD 8030A ACROLEIN AND ACRYLONITRILE BY GAS CHROMATOGRAPHY

National Research Council Institute for Ecosystem Study Verbania Pallanza - Italy

costech instruments ECS 4010 Elemental Combustion System CHNS-O

1,2-Dibromoethane (EDB) and 1,2-dibromo-3-chloropropane (DBCP), gas chromatography, microextraction

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

R021. BioTector TOC Analyzer Reagents_Mixer Reactor Systems

DI 3500 Discrete Aoalvzer

Mercury Stack Monitor SM-4

5. TOC in daily practice

Kjeltec 2300 Analyzer Unit

Phosphorus, Total. USEPA 1 PhosVer 3 with Acid Persulfate Digestion Method Method to 3.50 mg/l PO. Test preparation

TWO-STAGE ADVANCED OXIDATION PROCESS AS AN ALTERNATIVE TO THE THERMAL AND UV PERSULFATE OXIDATION FOR TOC ANALYSIS

Carbon (Organic, and Inorganic)

Method to 0.50 mg/l NH 3 N Powder Pillows

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Nitrogen total LR VARIO TT mg/l N b) Persulphate Digestion

Dimethylphenol Method Method to mg/l NO 3 N or 1.00 to mg/l NO

ISO 8245 INTERNATIONAL STANDARD. Water quality Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC)

Chromotropic Acid Method Method to 30.0 mg/l NO 3 N (HR) Test N Tube Vials

110 Lowell Rd Hudson, NH USA Tel:

Carbonate content. SCAN-N 32:98 Revised White, green and black liquors and burnt lime sludge

Method to 0.50 mg/l NH 3 N Powder Pillows

Salicylate Method Method HR (2 to 47 mg/l NH 3 N) TNTplus 832

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

DETERMINATION OF CHEMICAL OXYGEN DEMAND COD

Bromine 10 T mg/l Br 2 DPD

Glossary of Common Laboratory Terms

AOAC Official Method 2016.xx. Determination of Total Sulfur in Fertilizers by High Temperature Combustion

SECTION D.2 AMMONIA NITROGEN

novaa 800 D Atomic Absorption Spectrometer

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

Application Note No. 116 / 2013 Nitrogen determination in sodium nitrate

NITROGEN AND ITS COMPOUNDS Q30 (i) Explain how the following would affect the yield of ammonia. An increase in (i). Pressure.

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

Phosphate total HR TT mg/l P b) Phosphomolybdenum Blue

lems. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement task.

Sodium Chloride - Analytical Standard

Product Descriptions and Offerings

Industrie pharmaceutique

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Anethole. Gas chromatograhpy determination of trans-anethole in Spirit srinks of viti-vinicultural origin

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

METHOD 7196A CHROMIUM, HEXAVALENT (COLORIMETRIC)

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

NITROGEN, TOTAL, Test N Tube * Method 10071

Phosphate total LR TT mg/l P b) Phosphomolybdenum Blue

Member of the envea Group. Automatic Mercury Analyzer for the Laboratory

The Importance of Area and Retention Time Precision in Gas Chromatography Technical Note

Chemistry Instrumental Analysis Lecture 27. Chem 4631

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Manganese III Digestion Method * (with chloride removal)

Application Note #119 Alkalinity and Chloride by Titration

Chlorine, Free and Total, High Range

Determination of Pb, Cd, Cr and Ni in Grains Based on Four Chinese National Methods via Zeeman GFAAS

Scope and application: For water, wastewater and seawater. Distillation is required for wastewater and seawater.

Low Level Phosphorus: A Method Comparison Study

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Astoria-Pacific proudly offers our rapid-t software for the ChemWell-T an easy-to-use, compact automated chemistry analyzer:

Simplifying the Process: Automated USP 643 / EP

cobas e 411 analyzer Confidence in every result.

Water analysis Guidelines for the determination of total organic carbon (TOC) and dissolved organic carbon (DOC) ISO-CEN EN 1484

Using FIMS to Determine Mercury Content in Sewage Sludge, Sediment and Soil Samples

METHOD 9040B. ph ELECTROMETRIC MEASUREMENT

Thermo Scientific Dionex Ion Chromatography Solutions. Global water safety. bromate analysis in drinking water

2 EQUILIBRIUM 2.1 WHAT IS EQUILIBRIUM? 2.2 WHEN IS A SYSTEM AT EQUILIBRIUM? 2.3 THE EQUILIBRIUM CONSTANT

Preparation of Food and Feed Samples for Metals Analysis

Elemental analysis of river sediment using the Agilent 4200 MP-AES

The Claviature of Gas Analysis

Transcription:

Thermalllox TOC--TN The modern alternative to COD and TKN Thermal oxidation with unrivalled sensitivity Aqueous matrices with a solids option TOC, TC, TIC, NPOC, POC, TN b Total Organic Carbon: Total Carbon: Total Inorganic Carbon: Non-purgeable Organic Carbon: Purgeable Organic Carbon: Total Nitrogen Total Organic Carbon, Total Nitrogen

Measuring Total Organic Carbon methods drawbacks advantages TOC (Total Organic Carbon) is a measurement widely used in a number of industries to assess the organic contamination of water. In wastewater TOC concentrations of many thousands of ppm are often found. At the other extreme, low ppb TOC levels must be measured in the Ultra-Pure water used by Pharmaceutical, Semiconductor and the Power Generation industries. The basic techniques used to determine TOC are well established and suitable analytical equipment has been commercially available since the 60 s. Essentially, the total carbon (TC) of a water sample is measured by oxidising all the carbon species to carbon dioxide (CO 2). The resulting CO 2 is then detected using well understood analytical techniques, including Non-dispersive Infrared. The inorganic carbon in the sample (carbonate and bicarbonate) is either removed prior to the TC measurement, or the inorganic carbon is measured separately and this value is subtracted from the TC value to give TOC. Various oxidation techniques are used. Firstly, chemical oxidation using a strong oxidising reagent such as TiO 3 or a persulfate. Oxidation may only be partial, so care should be exercised with samples containing particulate or difficult to oxidise materials. This method is therefore generally unsuitable for high level samples, such as wastewater. A second method improves upon the wet chemical method by irradiating the sample with ultra-violet light after adding an oxidant such as persulfate. Photolysis of the persulfate and sample produces hydroxyl radicals and other strong oxidising agents which react with the organic carbon to produce CO 2. This technique is widely used and offers precision and some advantages at very low levels. However it is now accepted that the oxidation of particulate and many commonly occurring organics is quite poor. Indeed the EN1484 standard for TOC specifically cautions against it where humic material or particulate need to be measured (In other words where you have to measure TOC as opposed to DOC). The third technique, developed by Dow Chemicals in the 60 s relies on introducing the sample into a furnace in the presence of a catalyst and oxygen. Thermal oxidation of the carbon produces CO 2. The method does not suffer from any of the incomplete oxidation problems of the methods previously described. However the furnace and catalyst can introduce contamination and because steam is produced this limits the flow of sample that can be introduced, restricting the detection limit of the method. With all the methods described the CO 2 product is generally measured as a gas using a Non-dispersive Infrared detector. Although the technique is very accurate and selective, sensitivity is very much a function of cost and most vendors will compromise by trying to process larger amounts of sample to produce more CO 2. Inevitably larger sample volumes reduce catalyst life, slow down the analysis and challenge the oxidation. At very low levels where the carbon oxidant will stay in solution as carbonate the carbon concentration can be 2- determined by measuring the CO 3 ion, using selective conductivity methods. The major problem here is making the conductivity detector selective to carbonate. However, conductivity is a very sensitive technique and therefore capable of determining PPT levels. The Thermalox employs the thermal catalytic oxidation technique to give near perfect oxidation, but combines this with the most sensitive detector manufactured anywhere in the world Oxidation Method Advantages Disadvantages Wet Chemical Inexpensive and robust. Inefficient oxidation. Poor with particulate or hard to oxidise compounds. Slow. Only for low levels UV Persulfate Good Precision, Low detection limits. Ideal for DOC in pure waters. Better than wet chemical, but still not good with particulate or humic material (i.e. natural waters) Thermal Catalytic Oxidation Near perfect recovery (oxidation). Fast. Higher ownership costs. Trace catalyst contamination means sensitivity is compromised 2 Thermalox

Thermalox Why choose the Thermalox over other thermal oxidation systems? Analytical Sciences has made important advances in its techniques for measuring TOC and TN b. Working with one of the world's leading NDIR analyser manufacturers, it has dramatically increased the sensitivity of its CO 2 detector. The Thermalox detector is now over twenty times more sensitive than its leading rival. In addition, the furnace has been constructed to virtually eliminate trace carbon contamination within the reactor and catalyst, without compromising catalyst efficiency. This allows lower injection volumes to be used leading to less catalyst contamination, more accuracy and faster measurements. It also provides a dramatic improvement in the detection limit for this method. Some manufacturers use Pt coated quartz wool for low level work. This is fine with DI water, but rapidly blinds in natural waters. Other manufacturers attempts to lower detection limits and increase the accuracy of their TOC and TN b thermal oxidation analysers have centred on using larger injection volumes. However this slows down measurements and shortens the operating life of the catalyst, particularly if contaminants salts, for example, are present in the samples. Our NO x detector employs a number of features to ensure excellent sensitivity and stability. As well as heating the reaction under vacuum, we utilise an innovative NO x NO reduction furnace that remains efficient over an extended life. We use electronic vacuum flow control to maintain stable conditions inside the reactor. For safe operation of the detector, ozone is catalytically decomposed before any gases are vented Another of the many benefits of using sensitive detectors is the long term stability of the calibration, which is exceptional. With these improvements, the sophisticated but userfriendly software and excellent build quality, the THERMALOX Environmental has become recognized as probably the most cost-effective, powerful and robust tool for the analysis of TOC and TN b anywhere in the world. The Thermalox tolerates salts and suspended material without sacrificing detection limits Catalytic thermal oxidation. The only way to measure real samples containing particulate or difficult to oxidise materials Standard Deviation better than 20ppb on low level Carbon Standard Deviation better than 10ppb on low level Nitrogen Upper Range Limit greater than 50,000ppm for TOC Detection Limit of better than 40ppb for TOC and 10ppb for TN Remember you can have b Analysis time less than two minutes per replicate stand alone TOC, stand Complete recovery, including Suspended Solid fraction alone TN b or combination Handles salts and particulate easily Holds up to 88 samples Complete washing between samples ensures no carry over Totally software driven from a Windows based platform Automatic preparation of calibration standards The Thermalox is so well automated that you can mix high and low level samples on the same vial rack 3 Thermalox

Thermalox The Thermalox Environmental is equipped, as standard, with features many manufacturers treat as extras and you can measure solids The Thermalox instruments utilize our Model 8000 XYZ autosampler. This gives maximum flexibility and allows a high degree of automation. Calibrants can be made up automatically; sparging, dilutions and sample agitation can easily be carried out. The standard vial rack holds up to 88 glass or disposable plastic vials, with or without lids. It can be chilled and we are happy to provide racks to suit special requirements. By using a special aspiration step, samples containing particulate can be automatically agitated, ensuring that a representative sample aliquot is aspirated from the vial. Both TOC by subtraction and by pre-stripping of inorganic carbon methods are fitted as standard Carrier gas generation fitted as standard on TOC no need for bottled gases Automatically prepares its own calibrants eliminates human error Peltier cooler for condensate removal - no desiccants Precise electronic mass flow control of the carrier gas stable calibrations Highly sensitive detectors prolongs catalyst life, lowers detection limit Stand-by Mode - limits carrier gas consumption and prolongs oven life Specially manufactured Carbon-free catalysis - virtually no blank carbon peak Direct Injection method - eliminates blockage or carryover contamination Options for adding the measurement of solids and sample sonication Windows Platform software. Easy to learn Easy to use Secure Robust Tailored to suit you 4 Thermalox

Thermalox Carbon Analysis begins by loading samples into a vial rack. The AS8000 XYZ autosampler handles up to 88 vials. A sample aliquot from 3µl to 150µl is injected into the TC furnace through a special carbon free septum. CO 2 free Carrier gas sweeps the oxidant through to the CO 2 detector. Concentration is monitored by a PC and a characteristic asymmetric peak is plotted, the area of which is proportional to the CO 2 product of the oxidation. By calibration, TC is then determined from this peak area. The inorganic carbon, carbonates, bicarbonates and dissolved CO 2 are either stripped from the sample prior to the TC measurement, or this fraction is measured separately by introducing an aliquot of sample into the TIC reactor. This reactor contains phosphoric acid heated to 120 C which reacts with the carbonate to form CO 2. This is swept to the CO 2 detector and measured in the same way as the TC fraction. Both of these methods, TOC by difference and TOC by acid stripping (sometimes known as NPOC non purgeable organic carbon) are available on the Thermalox Instrument as standard. The disadvantage of the difference method is that if most of the carbon present is inorganic, the inaccuracy of the difference value, TC-TIC, will be too large. The disadvantage of the acid stripping method is that there is a risk of stripping out purgeable organic material and at low levels contaminating the sample. To handle samples with high levels of suspended solids, such as effluents, large bore needles up to 1.0mm - may be fitted to the autosampler. 5 Total Organic Carbon

Thermalox Nitrogen Total Nitrogen (TN) determination may be added to the Thermalox TOC analyser to give TOC and TN measurements from the same vial. We also manufacture the Thermalox TN b analyser where only this analyte is required. In the same way as TC measurements are performed, a sample aliquot is injected into a catalytic furnace. Carrier gas (oxygen) sweeps the oxidant, in this case NO x gases, through to the NO x detector. The NO concentration is monitored by the PC controller and a characteristic asymmetric peak is plotted, the area of which is proportional to the NO x product of the decomposition. By calibration, TN b is determined from this peak area. As can be seen from the graph below, temperature, concentration and injection volume have a critical effect on the conversion of R-N to NO. The detector utilizes the chemiluminescent reaction between NO and O 3 to determine the NO concentration. Because NO 2 is also present as an oxidant, this is reduced in a special reduction furnace to NO a step many of our competitors omit. The importance of this reduction step is illustrated by the different NO/NO 2 splits of the various compounds shown below. Oxidation Ratios NO/NO2 100 95 90 85 80 1.0mg/l Sodium Nitrate 1.0mg/l Creatinine 10.0mg/l Ammonium Chloride 10.0mg/l Creatinine Unlike most vendors, our chemiluminescent reaction is performed under vacuum in a heated chamber. This gives the Thermalox TN analyser its remarkable sensitivity; at least an order of magnitude more than its main rivals. NO NO2 For most applications the TC catalytic furnace can be modified to allow it to perform both the TC and TN decompositions. However for higher level TN applications up to 200mg/l or highly particulated samples, a specialised TN oven is added. This oven runs at up to 1000 C and has a larger internal volume and special catalyst. This overcomes the quenching effects experienced on many TN applications where larger sample volumes are needed or higher concentrations of TN are measured - for example effluent samples. Large bore needles may be used to aspirate particulated samples representatively. 6 Total Nitrogen

Thermalox Rangeability Calibration from two to 7 points may be automatically defined in the method set-up. The software then uses regression mathematics to generate a best fit curve. This may be a linear or an n-order polynomial function to give unrivalled rangeability. Automation Users can select a method which includes automatically preparing calibrants from a stock solution, calibration, acid stripping and measurement of TOC and TN all in one operation. The principals of FDA21 CFR11 are applied to ensure that the data is tamperproof and auditable. Sensitivity and precision It s very hard to beat the sensitivity and precision of the Thermalox range of elemental analysers. The following results were obtained on the Thermalox TOC/TN Environmental. Accuracy Test TC µg/l KHP TC mg/l KHP TC mg/l KHP TN µg/l NH 4Cl TN mg/l NH 4Cl TN mg/l NH 4Cl Concentration 145 1.97 10,108 101 1.03 201.6 138 1.99 10,023 98 1.02 200.8 143 2.00 10,098 98 0.98 199.4 Mean 142 1.99 10,076 99 1.01 200.6 Nominal Concentration 140 2.00 10,000 100 1.00 200.0 SD 2.9µg/l 0.01 mg/l 37.93 mg/l 1.25 µg/l 0.02 mg/l 0.91 mg/l CV 2.1 % 0.5 % 0.38 % 1.25 % 2.0 % 0.45 % Recovery TN Digestion Efficiency 40µl Injection Creatinine NH 4Cl (Calibrant) NaNO 3 Concentration (mg/l N) 98.8 100.3 102.0 98.2 99.8 101.8 98.7 100.1 101.7 Mean (mg/l N) 98.62 100.10 101.87 Nominal Concentration 100.00 100.00 100.00 SD (mg/l N) 0.26 0.20 0.13 Digestion Efficiency 98.6% 100.1% 101.9% The above samples were prepared by adding each of the chemicals in the nominal concentrations to deionised water. The digestion efficiency represents the ratio of nitrogen measured compared to the amount of chemically bound nitrogen contained in the sample. Oven Temperature was 950 C. Lower oven temperatures give a wider spread of recoveries at higher concentrations, but have some advantages with some matrices at low levels. 7 Thermalox

Thermalox Thermalox TOC/TN Analyte Applications Method Range Cycle time Precision Sample matrix Injection volume Sample injection Carrier gas TC, TIC, TOC, NPOC, POC with options for measuring TN and TP Drinking water, pharmaceutical cleaning in place water, ground water, surface water, saline waters, domestic, and industrial wastewater Total substance: Thermal catalytic oxidation at 680ºC (1000ºC for TN). Inorganic substance: acid stripping or injection into low temperature acid reactor (120ºC) Carbon: Various from less than a range of 40-150µg/l to greater than a range of 100-40,000mg/l: Nitrogen: From 20-100µg/l to 1.0-200mg/l Typically 120 180 seconds Standard deviation: 5% of full scale for ranges to 3mg/l; 3% of full scale for ranges up to 500mg/l and 2% of full scale for ranges up to 40,000mg/l Aqueous samples including those containing suspended solids and salts. Acids, slurries, sludges and organics by special application. A solids option is available 3 to 150µl. Needle diameters up to 1.0mm are available for particulated samples Automatically from an 88 position vial tray, or manually. A carrier gas generator is fitted as standard for TOC, except for very low level measurements. For TN, oxygen (grade 5.5 or better) is required; flow rate is 15 litres per hour or less. Power supply 230V AC ± 10%, 50Hz ± 1%; or 115V AC ± 10%, 60 Hz ± 1% Ambient temperature 5 35ºC Dimension and weight 645 W x 505 D x 650 H mm footprint (WDH) ; weight 50kg; (figures include sampler) Protection Class EMI class Euro 50081/50082. TOC and TN method compliance BS and DIN EN 1484 of 1997; ISO 8245, AOAC973.47, Standard Methods 5310B, Environmental Protection Agency (EPA) Methods 415.1, EPA SW-846 Method 9060A, ASTM D2579-85. TN according to DIN38409 part 27, ENV 12260 and ISO/TR11905-2. Solids Option Analyte Method Range TC, TIC, TOC TC by Thermal catalytic oxidation at 950ºC. TIC by acid decomposition at 120ºC. TOC by difference From 50µg C to 150mg C per sample Cycle time Precision Sample matrix Sample size Sample introduction Carrier gas Power supply Typically 5 minutes for TC, 8-31 minutes for TOC Greater of +/-15% or 15µg per sample Soils, Sludge, Slurries, Sediments, Polymers Maximum 1.0 gm Semi-Automatically Ambient temperature 10 40ºC Dimension and weight Analytical Sciences Limited, Cambridge, England CB3 9EY Telephone: +44 (0) 1223 569150; Facsimile: +44 (0) 1223 569152; Email: sales@analyticalsciences.com 12 litres per hour Oxygen, 5.5 grade. Also 18 litres hour dry compressed air for actuators. 230V AC ± 10%, 50Hz ± 1%; or 115V AC ± 10%, 60 Hz ± 1%. 950VA 585 H x 178 W x 406 D ; weight 12kg; All information within this publication is for reference purposes only; individual specifications for any product(s) may vary and are subject to change without notice. Publication 20-50-002 8