Cone differential pressure flow meter. Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

Similar documents
405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Integral V-Cone Flowmeter VD series

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Coriolis Mass Flowmeter. (MCM Series) 100% Customer Satisfaction MAXIFLO TM. Coriolis Mass Flowmeter Series MCM

Flow Monitoring Technologies in Oil and Gas. Don Ford, Technical Specialist Spartan Controls Ltd.

Volumetric Flow Measurement

Flow Measurement in Pipes and Ducts COURSE CONTENT

Conductivity sensor for hygienic applications

Target Insertion Flowmeter

Experiment (4): Flow measurement

Electromagnetic Flowmeter

SELECCIÓN DE CAUDALIMETROS. Tablas de Fabricantes

SITRANS F flowmeters. SITRANS F US System information SITRANS F US Ultrasonic flowmeters 4/181

Experiment No.4: Flow through Venturi meter. Background and Theory

ED 701 General Industry Pressure Transmitter

CORIOLIS MASS FLOW METERS FOR GAS AND LIQUID MEASUREMENT. Michael Keilty (Presented by Hubbard Donald) Endress + Hauser Flowtec AG

Serie B2.1. Flanged ductile iron ball valve. made in. Application fields. Shut-off valves E U R O P E. 18

Annubar Primary Element Flow Calculations

Fundamentals of Flow Metering

MX Series COMPACT AND USER FRIENDLY. Metal Tube Type Variable Area Flowmeter OUTLINE STANDARD SPECIFICATION MODEL CODE MX-400, MX-71 MX-52E

ULTRA OVAL Meter Sizes:39, 41, 45, 50, 52, 53 w/unfactored Pulse Generator (NPG60A)

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

Turbine Meter TRZ 03 PRODUCT INFORMATION. Reliable Measurement of Gas

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

IBV Series C Carbon Steel Inverted Bucket Vertical Steam Trap

IBV Series Z Alloy Steel Inverted Bucket Vertical Steam Trap

v = m / s Thermal Flow Sensors TA with thin-film sensor element Probes Probe Guides Measuring Tubes

Laboratory work No 2: Calibration of Orifice Flow Meter

Fluid Dynamics Exam #1: Introduction, fluid statics, and the Bernoulli equation March 2, 2016, 7:00 p.m. 8:40 p.m. in CE 118

DETERMINATION OF DISCHARGE AND HEAD LOSS USING A FLOW-MEASURING APPARATUS

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Applied Fluid Mechanics

Applied Fluid Mechanics

Pressure Transmitter ED 701

v = 00,20 m/s Thermal Flow Sensors TA with thin-film sensor element Probes Probe guides Measuring tubes

Orifice Plate. Stainless Steel. Flow Data. Herz Valves UK Ltd.

Chemical Engineering 3P04 Process Control Tutorial # 1 Learning goals

Flow Introduction. 1.1 Introduction Objectives History of DP Flow Pressure DP Flow

PTF30 Series. Features. Ordering information. G 6 N N F8 (0 to 5 kgf/cm 2 ) PTF30

Flow Measurement in Pipes and Ducts COURSE CONTENT

Orifice and Venturi Pipe Flow Meters

SECTION 1 - WHAT IS A BTU METER? BTU's = Flow x ΔT Any ISTEC BTU Meter System consists of the following main components:

Press. Allbest Creative Development Ltd. (ALLBEST)

FLOW MEASUREMENT. INC 102 Fundamental of Instrumentation and Process Control 2/2560

FLOW MEASUREMENT IN PIPES EXPERIMENT

ABSTRACT I. INTRODUCTION

Model Selection 1. Process Valves. Air. Vacuum

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Applicable Fluid. Accuracy. Flow Rate Range. Fluid Temperature. Fluid Viscosity. Connection Size. Flange Rating. Housing. Material. Blade.

An Essential Requirement in CV Based Industrial Appliances.

Mechanical Measurements and Metrology Prof. S. P. Venkateshan Department of Mechanical Engineering Indian Institute of Technology, Madras

MCE380: Measurements and Instrumentation Lab

Measurement of fluid flow in closed conduits

14:1400 (0206) KRAL Volumeter - OMG

ISEmax CAM40/CAS40. Technical Information

FLOW MEASUREMENT INC 331 Industrial process measurement 2018

Lecture 13 Flow Measurement in Pipes. I. Introduction

Instrumentation & Data Acquisition Systems

Operating Instructions for Digital Manometer. Model: MAN-SD

Measurements using Bernoulli s equation

Flow rate and mass flow rate

Orifice and Venturi Pipe Flow Meters

ph/o.r.p. probe Type 8619 multicell transmitter/controller General data Measuring range Bürkert ph probe Bürkert O.R.P. probe Medium temperature

04/01/1998 Developments in DP Flowmeters By Jesse Yoder

CHAPTER THREE FLUID MECHANICS

Model Selection 1. Process Valves

Process Gas Flow Measurement and Performance Evaluation API TECHNICAL REPORT 2571 SECOND EDITION DRAFT, FEBRUARY 2018

Introduction to Blackbody Sources

Name. Chemical Engineering 150A Mid-term Examination 1 Spring 2013

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

ME332 FLUID MECHANICS LABORATORY (PART I)

AEROSPACE ENGINEERING DEPARTMENT. Second Year - Second Term ( ) Fluid Mechanics & Gas Dynamics

CHAPTER (13) FLOW MEASUREMENTS

CHAPTER 3 BASIC EQUATIONS IN FLUID MECHANICS NOOR ALIZA AHMAD

2/3 Port Valves for Fluid Control Model Selection 1

ME411 Engineering Measurement & Instrumentation. Winter 2017 Lecture 11

INFLUENCE OF DIAPHRAGM EDGE ROUNDNESS ON THE MEASURED FLOW RATE

Pressure Measurement. Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level 2/27

DEPARTMENT OF CHEMICAL ENGINEERING University of Engineering & Technology, Lahore. Fluid Mechanics Lab

Direct-operated 2/2-way compact solenoid valves Type EV210A

Innovation in. Motionless Mixers

FINAL EXAM. ME 200 Thermodynamics I, Spring 2013 CIRCLE YOUR LECTURE BELOW:

Chapter 5. Mass and Energy Analysis of Control Volumes

REX Evaluation Guide. American Micro Detection Systems Inc March Lane, Suite 200 Stockton, CA 95219

ME 4600:483 Lab Notes Revised 11/16/2015. Flow Measurement

10 minutes reading time is allowed for this paper.

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Chapter 5. Mass and Energy Analysis of Control Volumes. by Asst. Prof. Dr.Woranee Paengjuntuek and Asst. Prof. Dr.Worarattana Pattaraprakorn

2/3 Port Valves for Fluid Control Model Selection 1

Cooling Water Flow Regulator

5 ENERGY EQUATION OF FLUID MOTION

Flow Measurement in Pipes and Ducts

VDN2.. VEN2.. VUN2.. Radiator valves. Building Technologies HVAC Products ACVATIX TM. NF norm, for 2-pipe heating systems

Laboratory 1: Calibration of a High-Volume Sampler

Readings for this homework assignment and upcoming lectures

2012 Thermodynamics Division C

VK2 volume flow controller Overview

first law of ThermodyNamics

Transmitters for basic requirements SITRANS P MPS (submersible sensor) Transmitter for hydrostatic level

Transcription:

Cone differential pressure flow meter Operating manual WIDE PLUS PRECISION INSTRUMENTS CO., LTD.

INDEX Introduction 2 Principle Application The characteristics of flow meter Specification Technical features Structural form 5 Precise pipeline dimension Model and specification 6 Attention of installation and service 1

Precise flow measurement An expert in the field of flow measurement Two-wire system connection The following products may be replaced to use Orifice plate Venture Nozzl vortex flow meter Vortex precession flowmeter Rotameter flow meter 1. Introduction Cone differential pressure flow meter that is an innovative flowmeter with high-precise flow measure and specially design to various kinds of difficult occasion carry out high-precisely survey to fluid. The product is throttled down a V type cone that is hanged on the center of manifold. This will force the fluid is centered as the centerline of manifold, and washed around the cone. Compare with traditional throttling component, this kind of geometric figure has many advantages. This product doesn t bring visible influence to its accuracy of measurement because of its special design, and enable it to apply to difficult measuring occasion such as no straight length, flow disorder, and biphase compound bodies and so on. 2. Principle Cone differential pressure flow meter belongs to differential pressure flowmeter that adopted the principle of conservation of energy. As shown in figure 1, when a medium is near measurement body, its pressure is P1, but when the medium pass over throttling zone of measurement body, its flow velocity is increased and its pressure is reduced to P2. Connecting P1 and P2 onto corresponding differential pressure transmitter via take pressure tap, and then work out the change of the flow according to changes of difference pressure. The fluid is proportional to square root of flow velocity of the medium in the pipeline. As shown in figure 1. Figure 1 A V type cone is hanged in the center of pipeline. After the fluid washed the cone, its speed quickened and kinetic energy increased. Kinetic energy improved in the section is switched by a fall of rest energy below the cone that is, a low pressure zone will be formed by down stream of V type cone. The quantity of the fluid is in linear with square root of difference pressure produced around V type. That is Bernoulli theorem of mutual energy transformation in the sealed pipeline. Q=KY Where: Q= flow, K= constant, dimensionless, result from different flow Y=expansion coefficient of gas, dimensionless, Y=1 when non-compression application P=P1-P2, p= density of fluid For cone-type differential pressure flowmeter: K= Where: K= instrument s coefficient, dimensionless, g= acceleration of gravity 2

D=internal diameter of pipeline, d=external diameter of the cone, =ratio of diameter, dimensionless, C=flow coefficient 3. Application Application medium Gas medium scale Coal gas (coke oven gas, blast furnace gas, generating furnace gas, gas of city pipe), natural gas (include natural gas covering wet 5% below), air, Oxygen, Nitrogen, Hydrogen, CO 2, CL 2, Methane gas, Propylene gas, fune, saturated steam, superheating steam, and wet gas and so on. Liquid scale: water, oil (containing crude oil, gasoline, diesel oil, kerosene, residuum etc.) emulsion, pure water, hydrogen peroxide, glycerine, alchhol, sewage, benzene and the other various kinds of liquid. Application area Oil, gas products and transportation petroleum refining purified water and waste water Chemical industry/medical technology energy/combined heat and power generation mining Paper pulp/papermaking manufacture food and beverage Application condition Form deep cooling to ultra critical situation Temperature: -100 500 Max. pressure: 40 MPa Reynolds number scope:8*103 5*106 (wide range) Full differential pressure scope: form 0.1 dozens of Kpa 4. Characteristics of flowmeter High accuracy: FS: 0.5% High repeatability: 0.2% or more Reforming function about the field of flow velocity Requirement around straight length is lowest Ratio of wide-range: generally 1 10 (require even higher) Low loss of pressure Difficult application occasion: dirty liquid, wet gas, pulp Low ratio of noise Self-cleaning function 5. Specification Accuracy: ±0.5% F.S. (application of fixed fluid and Reynolds which may be required to specially check) Repeatability: ±0.2% or more Ratio of range: 1 3 to 10 or higher Standard value: 0.45 0.85, special value may be used Loss of pressure: changes according to ß value and differential pressure 3

Requirement of mounting pipeline: 0 3 times diameter before measuring body 0 1 times diameter after measuring body Material: carbon-steel, 304 or 316 L stainless steel, P/PTFE or using special material meet users requirements 6. Technical features Ratio of wide-range Because of the design of cone differential pressure flowmeter is unique, its range is bigger, generally with from 1 3 to 1 30. If demand, it may be increased.. When Reynolds number is above 8000, its output signal is linear; if Reynolds number is below 8000, it needs to being modified to its output signal. Requirement of straight length is low Due to the curve of the fluid is distributed uniformly, compare with other flowmeter, the requirements for upstream/downstream length is lower. Generally speaking, length both upstream 0 3D and downstream 0 1D will completely meet its requirement. When the product is applied to large pipeline or limited occasion of installation position, it has irreplaceable characteristics. As shown in figure 2. Fig 2 Long-term stability well Special design in the cone which guaranteed the fluid is a gradation process and has no mutation when it flow the cone. First of all, the flow went through the cone, and then reached the edge of the cone again. So the cone couldn t be damaged frequently, value will always remain the same. If the apparatus will be used for a long time but needn t to be calibrated afresh. When cone differential pressure flowmeter is to being calculated, its calculation formula adopted is the same with other differential pressure flowmeter, but the structure of throttling part is the different with other flowmeter that is realized by the cone in the center of manifolds hanged. This cone will force the medium in the center of pipeline is washed around the cone, as shown in figure 3, its distribution of flow velocity is very equal. Figure 3 Due to the cone is hanged on the center of manifold, it directly contact with freeway zone in the fluid, to force the fluid at freeway zone is confused with the fluid near low speed zone of tube wall and then make flow velocity uniformity, therefore, flow velocity at freeway zone continued to decline. This is why cone differential pressure flowmeter is able to survey lower flow velocity. Cone differential pressure flowmeter distributes the fluid uniformly under the worst circumstances, such as upstream the proximate instrument on which has single bend and double bend. The 4

distribution of the fluid is more uniform via rectified the cone so as to be sure to get higher accuracy of measurement under the worst circumstances. As shown in figure 3. Signal stability well All of flow meters that adopt difference pressure measure will have signal wave, this is because the fluid is very stable even if entering measuring instrument. After thought once measuring component, it will also bring signal wave, and then creating interference to reading of measuring instrument, as shown in figure 4, that is in contrast to signal wave produced by cone differential pressure flowmeter and orifice flowmeter. Figure 4 With self-cleaning function The design of cone-type differential pressure flowmeter is unique, and made its cone doesn t exist dead zone, on the cone there don t accumulate fragments, viscosity or pollutant of the fluid, so with ability to self-cleaning 7. Structural form Cone differential pressure flowmeter that is divided into three things: precise pipeline type: size DN15 DN900 or bigger, mutual clip type: sizedn15 DN150, square type: size DN150 DN900. this instruction takes pipeline type for example. 8. Precise pipe dimension Precise pipe dimension Caliber Size A Size B Pipeline size Size D Size E Weight Size A B C (CS + Stainless) D E Kg Caliber mm mm mm mm G/NPT DN15 200 90 15.8 21.3 1/4 4 DN20 200 90 20.9 26.7 1/4 5 DN25 200 90 26.64 33.4 1/4 6 DN40 250 80 41.78 48.3 1/4 7 DN50 300 85 53.44 60.3 1/2 9 DN65 300 85 63.60 73.0 1/2 11 DN80 350 90 78.84 88.9 1/2 16 DN100 400 90 103.8 114 1/2 23 DN150 550 100 154.1 168 1/2 50 DN200 650 120 202.7 219 1/2 118 DN250 700 120 254.5 273 1/2 153 DN300 750 130 303.4 323 1/2 186 5

DN350 750 130 333.5 355 1/2 206 DN400 750 140 381.0 406 1/2 262 DN500 900 180 489.0 508 1 332 DN600 1200 200 590.6 609 1 481 DN700 1500 200 743 762 1 562 DN800 1500 240 813 1 726 DN900 1500 240 914 1 898 In the table, if there is any change, don t another notice. 8. Model and specification Model and specification options for cone-type differential pressure flowmeter WP Structural form Caliber Flange Degree of pressure Material of measuring tube Material of measuring cone Flange material Transmitter Model NT PT GT Description Precision pipeline type Precision square tube type Ordinary clamp-hold type () DN15 mm DN300 mm ST A D G S Special size 10 1 MPa 16 1.6 MPa 25 2.5 MPa 40 4 MPa ANSI flanged standard DIN2501 flanged standard GB9115 national standard User s requirement 3 304 stainless steel L C P T 316L stainless steel Carbon-steel PTFE/PP Special material 3 304 stainless steel L P 316L stainless steel PTFE/PP 3 304 stainless steel L C P 316 L stainless steel Carbon-steel PTFE/PP 0 None 1 Standard 2 Multi-parameter inspection with temperature, pressure, flow etc. 3 User s requirement Secondary 0 None 6

apparatus 1 Standard display 2 With display, accumulation 3 Display, accumulation and temperature compensation 2 0.2 degree Accuracy 5 0.5 degree N No protection Protection E Protection 0 None Accessories 1 With manifolds 2 With matching flange 1. Option for example: WP-NT0020G16L310N1 NT: precision pipeline type 0020: caliber DN20 G: GB9115 flange standard 16:1.6 MPa L: material of measuring tube is 316L stainless steel L: material of measuring component is 316 L stainless steel 3: connecting flange material is 304 stainless steel 1: standard transmitter 0: without secondary apparatus N: no anti-explosion 1: with manifolds 2 Please offer the following parameters when ordering (1) Caliber (2) Measuring medium (3) Maximum measuring range (or maximum flow M 3 /H) (4) Normal working scope (5) Minimum measuring range (or minimum flow M 3 /H) (6) Working pressure (7) Working temperature (8) Density of medium (9) Viscosity of medium (10) Using local average atmosphere 9. Attention for installation and service Fluid direction of coned throttling device should be in conformity to arrow direction of equipment body When measured medium is vapor or higher than 60 degree, which should be additionally mounting condenser to reduce temperature so as to avoid damaging inspection elements in the rear of differential pressure Before mounting the equipment, please sweeping the pipeline in advance Confirming the degree of pressure when ordered, be sure to usage in the range of pressure Don t hit the cone in the pipeline, if there some cones tends to twist, then measuring accuracy will be affected. After select to use the throttling device, random accompanied by a calculation book of range, 7

please check up on corresponding condition of process. If there is not the same, then contact us and afresh calculating range Except damage by human factor, this equipment will be carried out quality assurance since the date of delivery within 18 months This equipment matches to use with differential pressure transmitter, its range refers to calculation sheet, and output signal must act as square root to deal with flow. Attached reference diagram of installation 8