Manual. CBT Sensor H3L3 v1.0. Updates to this manual found at:

Similar documents
Coulomb blockade thermometry, primary thermometer, traceability, thermodynamic temperature

LECTURE 2: Thermometry

B I A S T E E Reducing the Size of the Filtering Hardware. for Josephson Junction Qubit Experiments Using. Iron Powder Inductor Cores.

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

Electronic refrigeration and thermometry in nanostructures at low temperatures

Peltier Application Note

Using a Mercury itc with thermocouples

Charge spectrometry with a strongly coupled superconducting single-electron transistor

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Application Note Thermal Design for the AWB, AWM and AWT series of Power Amplifier Modules Rev 0

SVSM User Training and Example Sequences

THERMOMETRY above 1 Kelvin

Main Applications Par lighting LED Bulb Ceiling lighting Spot lighting Down lighting

Coulomb s Law PHYS 296

Low temperature thermometry in high magnetic fields. VII. Cernox sensors to 32 T

Main Applications High specification down lighting LED Bulb Ceiling lighting Spot lighting Low-Bay lighting

THERMYS 150. Advanced field reference thermometer / temperature calibrator

Main Applications High specification down lighting High profile architectural lighting Street lighting Stage lighting High-Bay & Low-Bay lighting

PHYS320 ilab (O) Experiment 2 Instructions Conservation of Energy: The Electrical Equivalent of Heat

ME 4/549 Lab Assignment 5: Single Block Experiment Spring 2006 due 1 June 2006

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

single-electron electron tunneling (SET)

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-3 umodule SPOT PHASED OUT 46,5 39,5 35,5 NTC NTC LED + LED 8,5 4,5 8,5

BMXART0814 analog input module M340-8 inputs - temperature

IC Temperature Sensor Provides Thermocouple Cold-Junction Compensation

3mm Photodiode PD204-6B

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

Resistivity vs. Temperature of a Superconductor WARNING

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P320-2 umodule SPOT C.PHASED NTC

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P330-3 EM umodule SPOT PHASED OUT NTC NTC LED + LED + LED EM LED EM

WW25R ±1%, ±5%, 2W Metal plate low ohm power chip resistors Size 2512 (6432)

WW25Q ±1%, ±5%, 1W Metal plate low ohm power chip resistors Size 2512 (6432)

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

LAMP UTW/S400-X9/T10(WS)

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-3 EM umodule SPOT PHASED OUT 39,5 35,5 NTC NTC

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

U LED modules, converters and systems GENERAL ILLUMINATION. Umodule SPOT P310-2 umodule SPOT C.PHASED NTC

EVERLIGHT ELECTRONICS CO., LTD.

UVTOP265-HL-TO39. Description. Maximum Rating (T CASE = 25 C) Electro-Optical Characteristics (T CASE = 25 C, I F = 20 ma)

1. Voltage is how much work is being done for a charge. 2. Lightning is the electric breakdown of air by weak electric fields and is a flow of energy.

LAMP /T2C1-4WYC

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Microcare LCD Solar MPPT User Documentation

PHY3901 PHY3905. Hall effect and semiconductors Laboratory protocol

3mm Advanced Super Flux LEDs B84-YSC-A1T1U1DH-AM

Precise Thermometry for Next Generation LHC Superconducting Magnet Prototypes

Microwave Enhanced Cotunneling in SET Transistors

334-15/T2C3-4RTC InGaN White Water Clear

Thermal Coatings for In-vacuum Radiation Cooling LIGO-T C R. Abbott, S. Waldman, Caltech 12 March, 2007

5mm Silicon PIN Photodiode, T-1 3/4 PD333-3B/H0/L2

Thermal design of the CFRP support struts for the spatial framework of the Herschel Space Observatory

V N (8) V N (7) V N (6) GND (5)

Microsemi Power Modules. Reliability tests for Automotive application

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

Technical Data Sheet 3ψ Infrared Piranha

PRODUCT SPECIFICATION 1 SCOPE APPLICABLE STANDARDS CATALOG NO. STRUCTURE..3 4 CONNECTOR SHAPE, DIMENSIONS AND MARTERIALS..

Nanoscale work function measurements by Scanning Tunneling Spectroscopy

LM34 Precision Fahrenheit Temperature Sensors

φ φ0.2 Bare copper wire 2352 Walsh Ave., Santa Clara, CA 95051, U. S. A. Tel.: (408) , Fax: (408)

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

PHOENIX CONTACT - 04/2016. Features

Principles and Applications of Superconducting Quantum Interference Devices (SQUIDs)

334-15/X1C5-1QSA. Technical Data Sheet. Features. Descriptions. Applications Message panels Optical Indicators Backlighting Marker Lights

LM34 - Precision Fahrenheit Temperature Sensor

MOFLEX. Insulated copper flexibars

Decade Capacitance System

Calorimetric tunneling study of heat generation in metal-vacuum-metal tunnel junction

Microwave Loss Reduction in Cryogenically Cooled Conductors R. Finger and A. R. Kerr

Critical Current Properties of HTS Twisted Stacked-Tape Cable in Subcooled- and Pressurized-Liquid Nitrogen

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

ph Probe ReallyEasyData com

technical bulletin Installation Instructions: Wall-Mount Dewpoint Probe ( )

Louisiana State University Physics 2102, Exam 2, March 5th, 2009.

FYSZ 460 Advanced laboratory work: Superconductivity and high T C superconductor Y 1 Ba 2 Cu 3 O 6+y

5484BN/R7DC-AHJB/XR/MS(ELA)

Design Guidelines for SFT Chipsets Assembly

arxiv:astro-ph/ v1 4 Sep 2001

5mm Infrared LED HIR383C/L289

UVTOP. Specification S-T39B-B (Formerly UVTOP250TO39BL) RoHS. Drawn Approval Approval

Coulomb s Law. Equipment list Qty Item Part Number 1 Coulomb Balance ES Voltage Suppy. Purpose

Welcome. Functionality and application of RTD Temperature Probes and Thermocouples. Dipl.-Ing. Manfred Schleicher

MODEL NAME : LLDMWW0-15K*0*A

Position calibration of cryogenic dark matter detectors

DATA SHEET WIEGAND WIRE SENSOR WS-UTS-4-U0, WS-UFS-4-U0

P-LED EALP03SXDOA1-AM. Lead (Pb) Free Product- RoHS Compliant

SCB10H Series Pressure Elements PRODUCT FAMILY SPEFICIFATION. Doc. No B

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

Trek electrostatic voltmeters Setup, environment, working conditions

PHASED OUT. LED light engine / OLED LED compact. Umodule SLE G4 15mm 2000lm 9x0 H EXC D50

Cryoconference Young researchers

Electrical Equivalent of Heat J

Preview of Period 17: Induction Motors and Transformers

LAMP /X1C2-1UWA

LED HIGH POWER CoB Product Data Sheet M074xxSSxx Series. LED HIGH POWER M074xxSSxx Series. Created Date: 05 / 22 / 2014 Revision: 0.

TABLE OF CONTENTS. IC Recorder. Model No. RR-US300E. Colour (S)...Silver Type

P-LED EALP03SXARA0-AM. Lead (Pb) Free Product - RoHS Compliant

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

SPECIFICATION. Topview 5550 SMD LED IWS 505-UG-K3. Product : Topview 5550 SMD LED Part No : IWS-505-UG-K3 Customer : Date : Ver.1.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Commercial Chip - R3L 16Vdc to 5kVdc

Transcription:

Manual CBT Sensor H3L3 v1.0 This manual describes the handling and assembly of CBT sensor provided by Aivon Oy, Finland. Further information: Aivon Oy Tietotie 3, FI-02150 Finland tel. +358-400-265501 email: info@aivon.fi Updates to this manual found at: www.aivon.fi

This manual applies to the following products: Sensor type Description Temperature range (C1) H3L3 CBT sensor unit, no magnet, bobbin, Cu screw 40 mk& 1 K (C1) H3L3m CBT sensor unit, magnet, bobbin, Cu screw * 40 mk& 1 K *=neodymium magnet, diameter 5 mm, height 2 mm, theoretical maximum holding strength 0.65 kg, max. temperature 80 C. The sensor H3L3m is used in cryogenic setups without external magnetic field or with field less than 50 mt. Sensor H3L3 is used when the cryostat is exposed to external magnetic field larger than 50 mt. & =lowest temperatures achievable only with properly thermalized and filtered wiring. Drawings Dimensional drawings can be found in Appendix I at the end of this manual. Figure 1: The sensor H3L3 consists of two gold-plated copper parts, lid and holder. From left to right: Opened sensor, sensor H3L3, sensor H3L3m with magnet, and bobbin B1. The sensor wire is 30-cm long phosphor bronze twisted pair. Unpacking and handling The sensor is delivered in ESD (ElectroStatic Discharge) package to prevent the sensor from electrostatic shocks. After removal from the original package the sensor should always be handled carefully taking into account proper ESD practices such as grounded wrist wraps, shoes, desks, tools, etc. The sensor H3L3m contains strong permanent magnet on top of the sensor package. Due to magnetic forces the sensor can move suddenly if magnetic objects e.g. tools are in close proximity. Please use nonmagnetic or plastic tools when working with these sensors. Please keep the package in case you need to transport or return the sensor.

The user is encouraged to measure the room-temperature resistance of the sensor from the loose wire ends of the twisted pair sensor wire. Use measuring current not exceeding 0.01 ma. Make also sure that you do not expose the sensor to voltages exceeding 5 V. If the resistance is not between 40 kohm 70 kohm, please contact Aivon. Do not open the sensor. Warranty is not valid if the cover is removed. If the lid detached from the holder, please attach it carefully on top of the holder and observe that the wire is fed thru one of the grooves on the lid. Contact Aivon for further assistance and possible replacement. Assembly Clean the surfaces and apply suitable thermally conducting paste such as Apiezon N to improve thermal contact between sensor and substrate. Attach the sensor with a M4 screw to the substrate. A copper screw is provided. Also other screw materials can be used provided that thermal contraction is taken into account. In order to improve thermal anchoring of the 30-cm long sensor wire, the user should attach bobbin B1 either on top of the sensor (using same mounting hole and screw) or nearby the sensor. The wire should be tightly wrapped around the bobbin and attached using varnish or suitable epoxy (e.g. Stycast). Solder the loose end of the sensor wire to your setup using standard lead-free or leaded solder using temperature not exceeding 320 degrees C for short time not exceeding few seconds. Wiring recommendations All sensors need only two wires to measure the resistance. The sensor resistance is approximately 60 kohms and thus a 100-Ohm wiring resistance yields only 0.17 % error in resistance reading. Obviously, the wiring resistance can be compensated to make error even smaller. You can also make four-wire measurements by attaching two wires per one sensor wire by soldering. If properly mounted by the user, the sensor described in this manual cover temperature range 40 mk 1 K. Ultra low temperature operation If the sensor is operated below 100 200 mk, poor wiring can prevent the sensor from following the cryostat temperature. Thus it is recommended that the wiring has the following properties: - thermal anchoring. The sensor twisted pair is not thermally anchored. Thus, the user must thermalize the wiring to the same temperature stage that is being measured by the sensor. The use of bobbin B1 is recommended (see Assembly) - rf filtering. At lowest temperatures, a tiny radio frequency (rf) power can heat up the sensor and give incorrect readings. It is thus recommended to ensure rf tightness of the whole cryostat. It means that all room temperature connectors have to be filtered at radio frequencies. It might be important to use auxiliary low temperature filters such as powder filters close to the sensor. One possibility to arrange adequate wiring is to use so-called thermocoax (www.thermocoax.com). In this case thermocoax cable is fed from room-temperature rf tight connector down to lowest temperatures. The

cable should be thermally anchored in several stages to ensure negligible heating power along the cable to the sensor. A good overview of the wiring techniques is found in Ref. 5. Low temperature operation above 200 mk. At higher temperatures the requirements for wiring are less stringent. A moderately thermally anchored (to e.g. 4K, 1K and sample temperature) twisted pair is adequate. Suitable resistive materials for twisted pair wire are phosphor bronze, constantan or manganin. Also rf filtering can be lighter. Noise heating of 4 pw at 200 mk would imply an error less than 1% from the actual temperature. Operation The operation of Coulomb Blockade Thermometer is based on tunneling of current-carrying electrons in small metallic tunnel junctions or arrays of junctions [1]. The differential conductance depends on voltage bias and electron temperature of the sensor as depicted in Figure 2, where the conductance is normalized by G T, the conductance at high bias voltages (G T ~ (60 kohm) -1 ).

Figure 2: Normalized conductance curves at different temperatures. Fits are based on full theory (Ref. 4.) It has been shown [1] that the full width at half maximum V ½ of the conductance curve is proportional to temperature by V ½ = 5.439 x N k B T / e, where N=100 is the number of series tunnel junctions in the array, Boltzmann constant k B = 1.38x 10-23, and electron charge e = 1.609 x 10-19 C. This equation is valid within 5% at temperatures above 40 mk. Thus, by measuring the full width V ½ one obtains primary temperature T pri from T pri = ev ½ / (5.439 x N k B ) = 21.44 x V ½ [K/V]. The normalized depth of the conductance curve dip g = G 0 /G T at zero bias voltage is inversely proportional to temperature, g = Cal / T, where Cal is a sensor-specific calibration constant. By once measuring the primary temperature T pri and the corresponding dip depth g pri = G 0 /G T at the same temperature, one can obtain unknown temperature T by measuring g and using the following equation: T = T pri x g pri /g. Since G T depends only slightly on temperature one can make fast measurements on temperature T fast by measuring the zero-bias conductance G 0 only and by using the equation T fast = T pri x G 0pri /G 0, where G 0pri is G 0 measured at T pri. The above formula is accurate if the temperature T fast does not deviate too much from the previously obtained T pri. The advantage of measuring only the zero-bias conductance instead of full conductance curve is that it heats the sensor several orders of magnitude less due to absence Joule heating from dc voltage bias. Further studies of the theory and measurements on CBT s are found in references [2] [3] in the References section of this manual.

Practical instructions A) The operation of the sensor is based on normal-state electron transport. If you are using sensor without magnet H3L3 please apply an external magnetic field when the temperature is below the superconducting transition temperature of aluminum (~ 1K). B) To obtain reliable G T, use wide enough sweep for dc voltage bias. A rule of thumb: -2.5 x V ½ < V dc < 2.5 x V ½. Use figure 2 to estimate the voltage bias range needed. C) To measure the conductance dip accurately, use small enough ac excitation (probe) voltage. A rule of thumb: V ac < V ½ /10. Use figure 2 to estimate the ac voltage needed. Too small probe voltage yields noisy readings. References [1] J. P. Pekola, K. P. Hirvi, J. P. Kauppinen, and M. A. Paalanen, Thermometry by Arrays of Tunnel Junctions, Phys. Rev. Lett. 73, 2903 (1994). [2] K. P. Hirvi, J. P. Kauppinen, A. N. Korotkov, M. A. Paalanen, and J. P. Pekola, Arrays of normal metal tunnel junctions in weak Coulomb blockade regime, Appl. Phys. Lett. 67, 2096 (1995). [3] J. P. Pekola, J. K. Suoknuuti, J. P. Kauppinen, M. Weiss, P. v. d. Linden and A. G. M. Jansen, Coulomb Blockade Thermometry in the Milli-Kelvin Temperature Range in High Magnetic Fields, Journal of Low Temperature Physics, Vol. 128 (5-6), (2002). [4] M. Meschke, J. P. Pekola, F. Gay, R.E. Rapp, and H. Godfrin, Electron thermalization in metallic islands probed by Coulomb blockade thermometry, Journal of Low Temperature Physics, Vol. 134, 1119 (2004). [5] F. Pobell, Matter and Methods at Low Temperatures, 3 rd Edition, Springer-Verlag.

Appendix I: Drawings and dimensions (All drawings and dimensions are subject to change without prior notice.)