Non-Targeted Suspect Screening Strategies Using Low Resolution LC-MS-MS

Similar documents
RMassBank: Automatic Recalibration and Processing of Tandem HR-MS Spectra for MassBank

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

LC-MS Based Metabolomics

Making Sense of Differences in LCMS Data: Integrated Tools

Analytical Technologies and Compound Identification. Daniel L. Norwood, MSPH, PhD SCĪO Analytical Consulting, LLC.

WADA Technical Document TD2003IDCR

Agilent G3212 GC-APCI Source

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Features or compounds? A data reduction strategy for untargeted metabolomics to generate meaningful data

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

LC-MS. Pre-processing (xcms) W4M Core Team. 22/09/2015 v 1.0.0

Multi-residue analysis of pesticides by GC-HRMS

De Novo Metabolite Chemical Structure Determination. Paul R. West Ph.D. Stemina Biomarker Discovery, Inc.

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Finnigan LCQ Advantage MAX

MassHunter TOF/QTOF Users Meeting

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Welcome! Course 7: Concepts for LC-MS

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

WADA Technical Document TD2015IDCR

This document is a preview generated by EVS

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Protein Quantitation II: Multiple Reaction Monitoring. Kelly Ruggles New York University

Electron Ionization Source Parameters in GC-MS

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

A Platform to Identify Endogenous Metabolites Using a Novel High Performance Orbitrap MS and the mzcloud Library

1. Prepare the MALDI sample plate by spotting an angiotensin standard and the test sample(s).

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Powerful Scan Modes of QTRAP System Technology

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

TANDEM MASS SPECTROSCOPY

Analysis of Polar Metabolites using Mass Spectrometry

microtof-q III Innovation with Integrity The bench-mark in accurate mass LC-MS/MS ESI-Qq-TOF

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Quantitative Screening of 46 Illicit Drugs in Urine using Exactive Ultrahigh Resolution and Accurate Mass system

Thermo Scientific LTQ Orbitrap Velos Hybrid FT Mass Spectrometer

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating

Computational Methods for Mass Spectrometry Proteomics

Agilent ESI and APCI sources: for polar to non-polar compounds

Cerno Application Note Extending the Limits of Mass Spectrometry

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

TOMAHAQ Method Construction

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

Relative quantification using TMT11plex on a modified Q Exactive HF mass spectrometer

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Webinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Identifying Disinfection Byproducts in Treated Water

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

mzmatch Excel Template Tutorial

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Determination of challenging elements in ultrapure semiconductor grade sulfuric acid by Triple Quadrupole ICP-MS

Implementing GC-HRAM MS for More Efficient and Effective Routine Pesticide Residues Analysis

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Thermo Finnigan LTQ. Specifications

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Improved Screening for 250 Pesticides in Matrix using a LC-Triple Quadrupole Mass Spectrometer

SUSPECT AND NON-TARGET SCREENING OF ORGANIC MICROPOLLUTANTS IN WASTEWATER THROUGH THE DEVELOPMENT OF A LC-HRMS BASED WORKFLOW

Interpretation of Organic Spectra. Chem 4361/8361

Application Note. Edgar Naegele. Abstract

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Multi-residue GC-MS analysis. Richard Fussell CSL York, UK

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Choosing the metabolomics platform

Quantitative Analysis of Synthetic Opioids in Urine using Exactive LC-MS System

Accurate Mass Analysis of Hydraulic Fracturing Waters

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

FUTURE CONFIRMATORY CRITERIA

Analysis of a Verapamil Microsomal Incubation using Metabolite ID and Mass Frontier TM

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

At-a-Glance. Verapamil C 27 H 38 N 2 O 4 M+H + =

2016 iquan Series: Pesticide Quantitation on the Thermo Scientific TSQ Quantiva

THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Automated and accurate component detection using reference mass spectra

Very recently Roussis and Proulx clearly demonstrated

Transcription:

Non-Targeted Suspect Screening Strategies Using Low Resolution LC-MS-MS David Schiessel, Senior Chemist dschiessel@babcocklabs.com Babcock Laboratories, Inc. 6100 Quail Valley Court Riverside, CA 92507 951-653-3351 ext.268

Outline What, Why, When pertaining to non-targeted analysis Scope of Application Data Acquisition Data Processing (Example) Conclusions/Summary WHAT IF I TOLD YOU THAT I CAN PREDICT MASS ERROR ON LR-MS @10ppm

When Why What What, Why When Non-Targeted no assumptions made about what is present. (TICs ver. 2.0) Screening for 100-1000s of analytes using reference standards is prohibitively expensive and not practical Non-regulatory work. Client needs help/guidance Purely Discovery These are not the analytes you are looking for

Scope High-res accurate mass systems are used for this type of work However, TQMS is the best technology available in our lab Can I predict mass accuracy on a Triple- Quad?

Challenges/Solutions Data is NOT high-res Isobaric interference is possible Solution - Apply to limited number of unknowns; less complex matrices Masses may still not be accurate enough Solution Limit analyte suspects to known unknowns using a database.

Suspect Database Limit suspects to ESI responders Internal DB has 6054 ESI responders 2351 have known MS2 transitions Reverse search the observed molecular ion as being any possible adduct of any possible analyte. Search Chemspider/Pubchem using MassSpec API as a last resort (ie: if no candidates match molecular ion spectrum)

Challenges/Solutions Quadrupoles are not created equally Built-in centroiding algorithm is fast but not accurate nor precise in both mass and intensity Profile MS data reveals a distinct mass shape asymmetry Solution: Develop non-parametric regression model of profile peak across a mass range to improve centroiding accuracy

Triple Quad Limitations Mass shape also dependent on acquisition parameters (scan range, data rate, etc.) Solution: Carefully acquire sample data similarly to mass calibration verification Sensitivity in full scan is not so good Solution: Limit applicable concentration ranges to >100ug/L

Redefining Raw Data Test10 #937-957 RT: 5.69-5.81 AV: 11 NL: 6.31E5 F: - c ESI Q1MS [200.000-800.000] 238 100 90 237 239 80 Centroided Unit Resolution 70 60 50 40 30 20 240 10 241 0 242 236 237 238 239 240 241 242 m/z

Redefining Raw Data Test10 #937-957 RT: 5.69-5.81 AV: 11 NL: 6.31E5 F: - c ESI Q1MS [200.000-800.000] 237.8349 100 90 236.8576 238.8184 80 Centroided Low Res 0.4Da FWHM 70 60 50 40 30 20 239.8607 10 240.9436 0 241.9687 236 237 238 239 240 241 242 m/z

Redefining Raw Data Test11 #1631-1679 RT: 5.68-5.85 AV: 49 SM: 3B NL: 1.35E6 T: - p ESI Q1MS [232.800-242.800] 237.8300 100 90 Profile Apex Mass Low Res 0.2Da FWHM 80 70 236.8481 Note: peak assymetry 60 238.8320 50 40 30 20 10 239.3531 239.8741 0 236 237 238 239 240 241 242 m/z

Redefining Raw Data Test11 #1631-1679 RT: 5.68-5.85 AV: 49 SM: 3B NL: 1.35E6 T: - p ESI Q1MS [232.800-242.800] 237.8967 100 90 Profile Centroided Mass Low Res 0.2Da FWHM 80 236.9028 70 60 238.8959 50 40 30 20 10 237.4001 238.3997 239.3960 239.8979 240.4021 240.9593 241.9288 0 236 237 238 239 240 241 242 m/z

Data Acquisition Mass Calibration Verification (daily) Full scan ESI +/- (0.4m/z FWHM centroid) Molecular Ion Peak Picking, Adducts, Database Search SIM Profile MS Product Scan 237.8 > 50-800 Precursor Scan 1 (SO 3 80) Neutral Loss 6 (SO 2 64)

Data Acquisition Summary Full scan centroid at 0.4 FWHM in both ESI+/- from 90-1000mz Profile MS is duty cycle limited Perform Peak Picking Acquire SIM profile data at 0.2 FWHM Apply mass correction based on daily check data Database search mass/intensity

Mass Calibration Using 0.1% Phosphoric acid in 50:50 MeOH:Water as mass calibrant Full mass calibration weekly ~ 2 hours (25mins/Quad/polarity) Daily mass check in septuplicate (5mins) using mass calibrant at 10 masses Used to build mass correction curve and upper/lower bounds for suspects Manual Tune Tweaks (Voltages, Fits)

Mass Error Prediction Curve - upper/lower bounds

Mass Error Prediction Data Relative Error (ppm) Mass(Da) Rep1 Rep2 Rep3 Rep4 Rep5 Rep6 Rep7 StdDev Mean 99.7% conf interval 98.98417 154.4454 147.8787 144.8479 147.3736 149.8992 145.353 140.3017 4.4 147.2 133.9 160.4 196.9611 57.11872 59.14958 58.38801 57.62643 52.54929 61.18044 60.16501 2.8 58.0 49.6 66.4 294.938 20.80291 20.80291 21.9896 18.26 20.29432 20.29432 21.48102 1.2 20.6 17.0 24.1 392.9149 3.15705 3.411558 6.974671 7.356433 6.847417 6.465655 4.938607 1.8 5.6 0.3 10.9 490.8918-5.00042-4.59289-3.88001-4.28743-3.98186-1.23176-3.47258 1.2-3.8-7.5-0.1 588.8686-5.21221-4.61785-3.00459-1.47624-0.45733-2.49514-3.59895 1.7-3.0-8.0 2.1 686.8455-1.88535-1.01179-2.46772-1.37577-1.88535-1.81255-2.54051 0.5-1.9-3.5-0.2 784.8224 7.059509 4.192619 5.976462 6.231297 4.765997 6.295005 5.849045 1.0 5.8 2.8 8.7 882.7993 10.11086 12.20647 13.39587 12.37638 11.47018 13.79234 13.79234 1.4 12.4 8.4 16.5 980.7762 23.70595 26.71377 29.92551 27.93729 26.56083 23.96085 28.65101 2.3 26.8 19.8 33.7

Analytical Parameters Suggested Mobile phase: Water with dilute NH 4 OH (0.02%) + Methanol (protic). Use C8 or C18 column to use SLogP to eliminate candidates based on retention time No Acetonitrile: ACN completely suppresses certain analyte classes 5 (pyrethroid esters) Direct aqeuous injection Minimize background and the possibility of missing potential analytes (nonextractables)

Step1: Data partitioning Separate full scan into 10mz bins and perform peak picking RT: 0.00-12.00 SM: 3B 100 80 60 RT: 6.17 NL: 8.72E6 Base Peak m/z= 363.00-373.00 F: + p ESI Q1MS [363.000-373.000, 405.000-415.000, 450.000-460.000, 520.000-530.000, 678.000-688.000] MS ICIS SIM-Pyr5-1B 40 20 RT: 6.74 RT: 5.81 RT: 8.41 0 100 80 60 RT: 7.16 RT: 6.78 RT: 7.37 NL: 2.19E7 Base Peak m/z= 405.00-415.00 F: + p ESI Q1MS [363.000-373.000, 405.000-415.000, 450.000-460.000, 520.000-530.000, 678.000-688.000] MS ICIS SIM-Pyr5-1B 40 20 0 100 80 60 40 RT: 6.37 RT: 6.75 RT: 7.17 RT: 8.04 RT: 9.25 NL: 5.63E6 Base Peak m/z= 450.00-460.00 F: + p ESI Q1MS [363.000-373.000, 405.000-415.000, 450.000-460.000, 520.000-530.000, 678.000-688.000] MS ICIS SIM-Pyr5-1B 20 RT: 10.99 0 100 80 60 RT: 6.89 NL: 2.59E7 Base Peak m/z= 520.00-530.00 F: + p ESI Q1MS [363.000-373.000, 405.000-415.000, 450.000-460.000, 520.000-530.000, 678.000-688.000] MS ICIS SIM-Pyr5-1B 40 20 0 RT: 3.88 RT: 6.70 RT: 7.80 0 1 2 3 4 5 6 7 8 9 10 11 Time (min)

Step 2: SIM Profile Generate Mass/Intensity List SIM-Pyr5-1B #1518-1535 RT: 7.10-7.17 AV: 18 NL: 1.28E7 F: + p ESI Q1MS [363.000-373.000, 405.000-415.000, 450.000-460.000, 520.000-530.000, 678.000-688.000] 408.07 100 95 90 85 80 75 70 65 410.05 60 55 50 45 40 35 30 25 409.09 20 413.02 15 10 411.01 412.05 414.98 5 414.02 405.18 406.22 406.84 407.20 409.45 0 410.47 411.71 413.32 405 406 407 408 409 410 411 412 413 414 415 m/z

Step 3: Gather Information Determine Corrected Monoisotopic Mass Look for Multiple Adducts Determine Charge: usually 1, but don t assume Assemble Mass/Intensity List and do a quick search. Compare observed with theoretical Best to search using automated algorithm Many suspects will be eliminated at this point

Automated Search Example Mass, Abun 408.1046,100 409.1118,23.53 410.1025,68.77 411.1107,15.5 412.0993,12.85 20ppm Mass Error http://massspec.info/php/spdr4ms.php

Spectral Accuracy Experimental Data mz inten mzacc FWHM mzcorr RelInt 408.1087 8808896 408.1071 0.2313 408.1046 100 409.1307 2072994 409.1143 0.239 409.1118 23.53 410.1127 6058035 410.105 0.2286 410.1025 68.77 411.1147 1365217 411.1132 0.2411 411.1107 15.50 412.0966 1131671 412.1018 0.2335 412.0993 12.85 Theoretical m/z Abund 408.11297 100 409.11627 23.42 410.11039 67.03 411.11334 15.19 412.10855 12.37 413.1105 2.49 http://massspec.info/php/spectrumsim.php

Data Processing Tools ReAdW.exe: Export ThermoSci raw data files to mzxml (github.com/pedriolilab/readw) R packages: XCMS 2, mzr, envipat 3, npreg KNIME: Generate ESI bit-strings based on chemoinformatics (knime.org) MS2 Analyzer 4 : Piece together MS2 fragmentation scans

Final Thoughts Mass accuracy can be predicted with known error and precision limits on a reasonable time scale using a triple-quadrupole. Some non-targeted suspects can be eliminated based on narrower mass tolerances and whether or not they respond in ESI Knowing the limitations of a Low-Res MS system is key to applying mass measurements to sample data

Acknowledgements Dr. Creed Jones Software Engineering Professor, California Baptist University Klaus Schiessel Physicist (Retired), Northrop Grumman Justin Reed Senior Chemist, Babcock Laboratories

Questions?? David Schiessel, Senior Chemist dschiessel@babcocklabs.com Babcock Laboratories, Inc. 6100 Quail Valley Court Riverside, CA 92507 951-653-3351 ext.268

References 1) Storm, Thomas, Claudia Hartig, Thorsten Reemtsma, and Martin Jekel. Exact Mass Measurements On-Line with High-Performance Liquid Chromatography on a Quadrupole Mass Spectrometer. Analytical Chemistry 73, no. 3 (February 2001): 589 95. doi:10.1021/ac0006728. 2) Smith, Colin A., Elizabeth J. Want, Grace O Maille, Ruben Abagyan, and Gary Siuzdak. XCMS: Processing Mass Spectrometry Data for Metabolite Profiling Using Nonlinear Peak Alignment, Matching, and Identification. Analytical Chemistry 78, no. 3 (February 2006): 779 87. doi:10.1021/ac051437y. 3) Loos, Martin, Christian Gerber, Francesco Corona, Juliane Hollender, and Heinz Singer. Accelerated Isotope Fine Structure Calculation Using Pruned Transition Trees. Analytical Chemistry 87, no. 11 (June 2, 2015): 5738 44. doi:10.1021/acs.analchem.5b00941. 4) Ma, Y., Kind, T., Yang, D., Leon, C., Fiehn, O., 2014. MS2Analyzer: A Software for Small Molecule Substructure Annotations from Accurate Tandem Mass Spectra. Analytical Chemistry 86, 10724 10731. doi:10.1021/ac502818e 5) Colizza, Kevin, Keira E. Mahoney, Alexander V. Yevdokimov, James L. Smith, and Jimmie C. Oxley. Acetonitrile Ion Suppression in Atmospheric Pressure Ionization Mass Spectrometry. Journal of The American Society for Mass Spectrometry 27, no. 11 (November 2016): 1796 1804. doi:10.1007/s13361-016-1466-1.