Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Similar documents
Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Metabolomic Profiling of Accurate Mass LC-MS/MS Data to Identify Unexpected Environmental Pollutants

Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou AB SCIEX, Concord, Ontario, Canada

Food & Environmental. Overview. Introduction. Method Details. André Schreiber and Yun Yun Zou SCIEX, Concord, Ontario, Canada

Overview. Introduction

The Quantitation and Identification of Coccidiostats in Food by LC-MS/MS using the AB SCIEX 4000 Q TRAP System

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Quantitative Analysis and Identification of Migrants in Food Packaging Using LC-MS/MS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Choosing the metabolomics platform

Untargeted Screening on the X500R QTOF

Identifying Disinfection Byproducts in Treated Water

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

Tyler Trent, Applications Sales Specialist, Teledyne Tekmar P a g e 1

Key Features of Targeted Metabolite Screening. Using the TripleTOF System, an Accurate Mass Metabolite Spectral Library and MasterView Software

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

Analyst Software. Peptide and Protein Quantitation Tutorial

Powerful Scan Modes of QTRAP System Technology

Automated and accurate component detection using reference mass spectra

Analyst Software. Automatic Optimization Tutorial

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Multi-residue analysis of pesticides by GC-HRMS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Methyl 1-[(4-fluorophenyl)methyl]indazole-3-carboxylate

Higher Confidence in Identification with QTRAP LC/MS/MS Systems when Screening and Quantifying Pesticides in Fruit and Vegetable Samples

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

WADA Technical Document TD2003IDCR

How to screen and identify unexpected and unwanted compounds in food

Advanced Data Acquisition and Data Processing Workflows to Identify, Quantify and Confirm Pesticide Residues

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

Nontarget Analysis via LC-QTOF-MS to Assess the Release of Organic Substances from Polyurethane Coating

Agilent All Ions MS/MS

N-(1-carbamoyl-2-methyl-propyl)-1-(5-chloropentyl)indazole-3- carboxamide

5Cl-AKB48 and 5Br-AKB48

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Forensic and toxicological drug screening using liquid chromatography-tandem mass spectrometry with MS/MS library based identification

4-methyl-1-phenyl-2-pyrrolidin-1-yl-pentan-1-one

Application News. No. C154. Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Theory and Practical Consequences.

Making Sense of Differences in LCMS Data: Integrated Tools

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Application Note LCMS-116 What are we eating? MetaboScape Software; Enabling the De-replication and Identification of Unknowns in Food Metabolomics

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Die Nadel im Heuhaufen

Analysis and Quantification of Mycotoxins in Cereals Using MRM HR on the SCIEX X500R QTOF System with SCIEX OS

Triumphs and Challenges of High-Resolution Mass Spectrometry in Comprehensive Residue Screens

Chemical Components Identification of Cistanche Deserticola Using the X500R QTOF System

Analysis of Polar Metabolites using Mass Spectrometry

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Metabolomics in an Identity Crisis? Am I a Feature or a Compound? The world leader in serving science

Improved Automated Sample Preparation for the Analysis of 25-OH-Vitamin D3 by LC/MS/MS

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

The new Water Screening PCDL

Quantitation of Ethyl Glucuronide and Ethyl Sulfate in Urine using LC-MS/MS

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

Performing Peptide Bioanalysis Using High Resolution Mass Spectrometry with Target Enhancement MRM Acquisition

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Compounding insights Thermo Scientific Compound Discoverer Software

Application Note LCMS-110 Development of a Targeted Quantitative LC-MS/MS Method for 431 Positive and Negative Ion Pesticides in a Single Analysis

This document is a preview generated by EVS

RMassBank: Automatic Recalibration and Processing of Tandem HR-MS Spectra for MassBank

Methyl 2-[[1-(5-fluoropentyl)indole-3-carbonyl]amino]-3,3- dimethyl-butanoate

Application Note LCMS-112 A Fully Automated Two-Step Procedure for Quality Control of Synthetic Peptides

Multiple Fragmentation Methods for Small Molecule Characterization on a Dual Pressure Linear Ion Trap Orbitrap Hybrid Mass Spectrometer

Structural Analysis by In-Depth Impurity Search Using MetID Solution and High Accuracy MS/MS

2-[[2-(4-ethyl-2,5-dimethoxy-phenyl)ethylamino]methyl]phenol

LC-MS Based Metabolomics

4-Methyldiethcathinone (4-MDEC)

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

X500R QTOF A COMPENDIUM OF RELATED RESEARCH APPLICATIONS

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

1-(1,3-benzodioxol-5-yl)-2-(ethylamino)hexan-1-one

Quadrupole Time-of-Flight Liquid Chromatograph Mass Spectrometer LCMS-9030 C146-E365

The Analysis of Organophosphate Pesticides by LC/MS Application

Multi-residue analysis of pesticides in crude food extracts using a simple extraction technique and LC/MS/MS

Rapid and Sensitive Analysis of Antibiotics in Children s Urine Using the X500R QTOF System

MassHunter Software Overview

Increasing Selectivity and Confidence in Detection when Analyzing Phthalates by LC-MS/MS

profileanalysis Innovation with Integrity Quickly pinpointing and identifying potential biomarkers in Proteomics and Metabolomics research

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Cerno Application Note Extending the Limits of Mass Spectrometry

MassHunter TOF/QTOF Users Meeting

Workflow Using Hyphenated Mass Spectrometry Techniques

Accelerated Impurity Profiling Workflow for Bulk Drugs and Formulations using an Accurate Mass Workhorse

Transcription:

LC-MS/MS Based Strategy for the Non-Targeted Screening of an Unlimited Number of Contaminants in Food Using the AB SCIEX TripleTOF 5600 System and Advanced Software Tools André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada Overview The following paper presents a procedure for non-targeted screening of an unlimited number of contaminants in food samples using high resolution and accurate mass Liquid Chromatography tandem Mass Spectrometry (LC-MS/MS) using the AB SCIEX TripleTOF 5600 system. QuEChERS extracts of different fruit and vegetable samples were analyzed, and the data statistically processed to find any unexpected contaminants. High resolution and accurate mass MS and MS/MS spectra were further processed to empirically calculate molecular formulae and to identify and characterize chemical structures. Introduction LC-MS/MS using Electrospray Ionization (ESI) is a powerful analytical tool for the analysis of a wide molecular weight range of polar, semi-volatile and thermally labile compounds. The most common LC-MS/MS routine to analyze food samples is the targeted quantitation of hundreds of food contaminants in a single analysis. Triple quadrupole based mass analyzers are preferred for these analyses, as they provide an extra degree of selectivity and sensitivity when operated in Multiple Reaction Monitoring (MRM) mode. In recent years, there is a growing movement to analyze food beyond target compound lists, and a shift towards non-targeted or general unknown screening. This change can be explained by the recent high profile food residue scandals, such as the detection of melamine in infant formula and the identification of the non-registered pesticide isofenphos-methyl in strawberries. Because neither of these compounds were targeted as potential contaminants they did not show up in conventional analyses; further investigation of food samples was not required until people became ill. 1-2 The ability to perform non-targeted screening on a routine basis is made possible through advancements in LC-MS/MS technology, including hybrid systems like the triple quadrupole linear ion trap (QTRAP ) and tandem quadrupole Time-of-Flight (TripleTOF ). However, since this workflow does not use a target analyte list, compound detection is not based on any a priori knowledge, such as retention times and information on molecular and fragment ions. Nor is it limited to a specific database of spectra or masses. These full scan data files are very rich in information and can easily contain thousands of ions from any compounds present in the sample as well as from the sample matrix itself. In order to mine these chromatograms for useful information powerful software tools are needed. Here we used MarkerView software to find unexpected contaminants in full scan chromatograms. By performing statistical data analysis using Principal Components Analysis (PCA) and Principal Components Variable Grouping (PCVG), unique contaminants in unknown samples were detected. PeakView software was used for empirical formula calculation, followed by searching of the internet for possible structure identities, and MS/MS fragment ion prediction to identify compounds and to characterize chemical structures. p 1

Method Details QuEChERS extraction of different kohlrabi and tomato samples UHPLC using a Shimadzu UFLC XR system with a Restek Ultra Aqueous C18 (100 x 2.1 mm) 3 µm column and a gradient of water and methanol with 10 mm ammonium formate at a flow rate of 0.5 ml/min Injection volume of 10 µl AB SCIEX TripleTOF 5600 system with Turbo V source and ESI probe Continuous recalibration between injections using the Calibrant Delivery System (CDS) Information dependent acquisition using a TOF-MS survey scan 100-1000 Da (100 ms) and up to 10 dependent TOF- MS/MS scans 50-1000 Da (100 ms) using Collision Energy (CE) of 35 V with Collision Energy Spread (CES) of ± 15 V Statistical data processing using MarkerView software (minimum spectral peak width 0.01 Da, retention time tolerance 0.3 min, noise threshold 100 cps; Figure 1) Empirical formula calculation and fragment ion prediction using PeakView software Figure 1. Non-target peak finding parameters applied in MarkerView software before PCA Results and Discussion 0.3 min High resolution and accurate mass LC-MS/MS chromatograms contain comprehensive information of all molecules present in the sample that are amenable to the ionization technique and polarity used. A non-targeted peak finding algorithm, like that integrated into the XIC Manager application of PeakView software, allows screening for unexpected compounds. 3 Mass spectral library searching can be used to identify non-targeted compounds based on their molecular fingerprint; however, identification is limited to compounds present in the MS/MS 0.01 Da Tomato Carbendazim Figure 2. Tomato sample processed using the non-targeted peak finding algorithm of the XIC Manager application in the PeakView software, Carbendazim was identified based on MS/MS library searching against an existing library of pesticides library (Figure 2). Different software tools are needed to identify compounds which are not present the library, or which are completely unknown. As a first step of data processing a list of the peaks of interest need to be generated. Every non-targeted peak finding algorithm is capable of doing so. However, the peak list generated by such an algorithm can easily contain thousands of chromatographic and mass spectrometric signals. In depth investigation of these signals would be time consuming and inefficient, since most of these signals are derived from chemical background and matrix components. Thus the peak list generated by a non-targeted peak algorithm needs to be reduced to a list containing peaks of interest only, i.e. undesired chemical residue in food. Statistical data processing is the most effective procedure to find peaks of interest in complex samples. Here a controlled set of samples is mathematically compared to remove background and to differentiate between signals characteristic for the sample matrix and true chemical residues. A popular tool for the processing of LC-MS/MS data is Principal Components Analysis (PCA). PCA is a mathematical algorithm of orthogonal linear transformation to reduce data complexity, while retaining most differentiating information. The information of greatest variance is saved into principal components (PC). The result of this mathematical transformation is displayed in a coordinate system of two PC, the scores plot. Similar samples cluster in similar areas of the scores plot. Thus PCA visually differentiates between clean and contaminated samples. p 2

As shown in the scores plots in Figures 3 and 4 (top left) PCA clearly differentiated between the contaminated kohlrabi and tomato sample, respectively, from both control samples and store bought samples. The loadings plots in Figures 3 and 4 (top right) show all variables (m/z-retention time pairs in this case) that make the most difference in separating samples. The list of variables can be fairly long depending on the complexity of samples. Principle Component Variable Grouping (PCVG) was successfully used to Scores plot Kohlrabi contaminated Loadings plot Kohlrabi supermarket Kohlrabi control Profile plot Figure 3. PCA and PCVG of kohlrabi samples, the scores plot was used to visualize the difference between samples (top left), the loadings plot with PCVG was used to identify characteristic m/z-retention time pairs (top right) which were verified in the profile plot (bottom) Scores plot Loadings plot Tomato contaminated Tomato control Organic tomatoes (supermarket) Profile plot Figure 4. PCA and PCVG of tomato samples p 3

reduce the number of variables selected for further data processing. The loadings plot of PCVG is a two-dimensional display using the information of more than two PC to color code the display in such a way that additional variation not otherwise 4 visible can be seen. The profile plot in MarkerView software was used to verify that all variables of the selected group were characteristic for the contaminated sample (Figures 3 and 4, bottom). The combination of PCA and PCVG was able to reduce the list of peaks of interest found by the non-target peak finding algorithm from thousands to only a few dozen signals. The highest signal responsible for the contamination in kohlrabi corresponded to m/z 266.0735 at 7.0 min. The Formula Finder in PeakView software was used to empirically calculate the molecular formula with information available on the accurate mass quasi-molecular ion, isotopic pattern, cluster ions, and MS/MS fragment ions resulting in C12H6N2O2F2 (Figure 5a). Figure 5b. Online search with ChemSpider to find possible structures matching the empirically calculated formula C12H6N2O2F2. The highest probability match was found to be the pesticide Fludioxonil. XIC of 266.07 TOF-MS Δm = 17 amu M+NH 4+ Δm = 5 amu M+Na+ M+H + Figure 5a. Empirical calculation of the molecular formula of the signal 266.07 Da at 7.0 min resulted in a molecular formula of C12H6N2O2F2 This formula was subsequently searched against online databases to find possible structures. The pesticide Fludioxonil was found by ChemSpider with the highest probability (Figure 5b). The suspected structure was then compared to the MS/MS spectrum using the fragment ion prediction tool in PeakView software. All accurate mass fragment ions matched the suspected structure (Figure 5c). Thus, Fludioxonil was identified as a major contaminant in the investigated kohlrabi sample. Figure 5c. With all MS/MS fragment ions matching the suspected structure, the detected compound was consequently identified as Fludioxonil. The same workflow was applied to the determination of the major contaminant of the tomato sample, m/z 406.0712. This mass revealed two chromatographic peaks at 8.4 and 8.6 min. The pesticide Difenoconazole was identified as the major residue in the contaminated tomato sample using empirical formula calculation, online database search, and fragment ion prediction (Figure 6a-c). p4

XIC of 406.07 TOF-MS M+Na+ M+NH 4+ Δm = 5 amu M+H + Δm = 17 amu Figure 6a. Empirical calculation of the molecular formula of the isomeric signals 406.07 Da at 8.4 and 8.6 min resulted in a molecular formula of C19H17N3O3Cl2 Figure 6c. With all MS/MS fragment ions matching the suspected structure, the detected compound was consequently identified as Difenoconazole Summary A straightforward procedure using generic QuEChERS extraction and high resolution accurate mass LC-MS/MS was used to screen for and identify non-targeted chemical residues in food samples using the AB SCIEX TripleTOF 5600 system. Here we combined statistical data analysis using PCA and PCVG followed by empirical formula calculation, online database searching, and MS/MS fragment ion interpretation to successfully detect unknown contaminants. Figure 6b. Online search to find possible structures matching the empirically calculated formula C19H17N3O3Cl2. The highest probability match was found by ChemSpider to be the pesticide Difenoconazole Utilizing minimal sample preparation, maximum data collection, intelligent signal filtering and an internet search of molecular formula; this workflow can provide the user with the ability to screen a set of samples for virtually every known chemical compound and identify undesirable contaminants quickly and easily. p5

Acknowledgements The authors would like to thank Jon Wong and Kai Zhang of the FDA Center for Food Safety and Applied Nutrition (CFSAN) in College Park, MD for providing samples for analysis. References 1 2 3 4 A.K. Hau et al.: Melamine toxicity and the kidney J. Am. Soc. Nephrol. 20 (2009) 245-250 St. Lehotay et al.: Identification and confirmation of chemical residues in food by chromatography-mass spectrometry and other techniques TrAC 27/11 (2008) 1070-1090 A. Schreiber.: Using PeakView Software with the XIC Manager for Screening and Identification with High Confidence based on High Resolution and Accurate Mass LC-MS/MS Application Note AB SCIEX (2011) 2170811-02 G. Ivosev et al.: Dimensionality Reduction and Visualization in Principal Component Analysis : Anal. Chem. 80 (2008) 4933-4944 For Research Use Only. Not for use in diagnostic procedures. 2011 AB SCIEX. The trademarks mentioned herein are the property of AB Sciex Pte. Ltd. or their respective owners. AB SCIEX is being used under license. Publication number: 3690611-01 Headquarters International Sales 353 Hatch Drive Foster City CA 353 Hatch Drive Foster City CA 94404 USA For our office locations please call the division Phone 650-638-5800 www.absciex.com headquarters or refer to our website at www.absciex.com/offices