The Dual-Phase Liquid Xenon Time Projection Chamber (TPC) of Münster

Similar documents
arxiv:physics/ v1 3 Aug 2006

Measurement of the transverse diffusion coefficient of charge in liquid xenon

Low Energy Particles in Noble Liquids

arxiv:astro-ph/ v1 15 Feb 2005

Measurements of liquid xenon s response to low-energy particle interactions

Light Dark Matter and XENON100. For the XENON100 Collaboration Rafael F. Lang Columbia University

Dark Matter Detection and the XENON Experiment. 1 Abstract. 2 Introduction

The Neutron/WIMP Acceptance In XENON100

PANDA-?? A New Detector for Dark Matter Search

XENONNT AND BEYOND. Hardy Simgen. WIN 2015 MPIK Heidelberg. Max-Planck-Institut für Kernphysik Heidelberg

The LZ Experiment Tom Shutt SLAC. SURF South Dakota

High pressure xenon gas detector with segmented electroluminescence readout for 0nbb search

DARWIN. Marc Schumann Physik Institut, Universität Zürich. Aspera Technology Forum 2010, October 21-22, 2010

XENON100. Marc Schumann. Physik Institut, Universität Zürich. IDM 2010, Montpellier, July 26 th,

The XENON1T Experiment

The next generation dark matter hunter: XENON1T status and perspective

Understanding the response of LXe to electronic and nuclear recoils at low energies

arxiv:physics/ v1 [physics.ins-det] 14 Feb 2005

Prospects for WIMP Dark Matter Direct Searches with XENON1T and DARWIN

XENON1T: opening a new era in the search for Dark Matter. Elena Aprile, Columbia University on behalf of the Collaboration, UCLA, February 17, 2016

Effects of Nitrogen and Oxygen contamination in Liquid Argon

Direct WIMP Detection in Double-Phase Xenon TPCs

Scintillation Efficiency of Nuclear Recoils in Liquid Xenon. T. Wongjirad, L. Kastens, A. Manzur, K. Ni, and D.N. McKinsey Yale University

THE qualities of liquid xenon (LXe) as an efficient

Supernova Neutrino Physics with XENON1T and Beyond

Dark Matter Detection and PMT Base Optimization

Distillation purification and radon assay of liquid xenon

DARWIN. Marc Schumann. U Freiburg PATRAS 2017 Thessaloniki, May 19,

Direct dark matter search using liquid noble gases

Oddities of light production in the noble elements. James Nikkel

Cleaning Electronegative Contamination from Gaseous Xenon Through Cryogenic Pumping

LAAPD Performance Measurements in Liquid Xenon

PHY 599: How it is usually done

Factors Affecting Detector Performance Goals and Alternative Photo-detectors

TWO-PHASE DETECTORS USING THE NOBLE LIQUID XENON. Henrique Araújo Imperial College London

PoS(EPS-HEP2017)074. Darkside Status and Prospects. Charles Jeff Martoff Temple University

PANDA-X A New Detector for Dark Matter Search. Karl Giboni Shanghai Jiao Tong University

THE NEXT EXPERIMENT FOR NEUTRINOLESS DOUBLE BETA DECAY SEARCHES ANDER SIMÓN ESTÉVEZ ON BEHALF OF THE NEXT COLLABORATION

nerix PMT Calibration and Neutron Generator Simulation Haley Pawlow July 31, 2014 Columbia University REU, XENON

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

The XENON1T experiment

Liquid Argon TPCs for future neutrino oscillation experiments

PandaX detector calibration and response. 报告人 : 肖梦姣 Shanghai Jiao Tong University (On behalf of the Panda-X Collaboration)

The XENON100 Dark Matter Experiment

DARWIN. Marc Schumann. U Freiburg LAUNCH 17 Heidelberg, September 15,

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

Two-phase and gaseous cryogenic avalanche detectors based on GEMs

can be read by PMTs w/o wave length shifter

Background and sensitivity predictions for XENON1T

DARWIN: dark matter WIMP search with noble liquids

The XENON100 Dark Matter Experiment at LNGS: Status and Sensitivity

XEMIS: The new Compton camera with liquid xenon

DarkSide-50: Investigating Low Energy Peaks

XENON Dark Matter Search. Juliette Alimena Columbia University REU August 2 nd 2007

The XENON Project. M. Selvi The XENON project

Kenji Ozone (ICEPP, Univ. of Tokyo, Japan) Outline. Introduction prototype R&D ー PMTs ー small & large type summary

Gamma and X-Ray Detection

Studies of the XENON100 Electromagnetic Background

Prospects for 0-ν ββ Search with a High-Pressure Xenon Gas TPC. What s NEXT?

DarkSide new results and prospects

The Search for Dark Matter with the XENON Experiment

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

The XENON Dark Matter Project: Status of the XENON100 Phase. Elena Aprile Columbia University

Direct dark matter search using liquid noble gases

The ArDM project: A Liquid Argon TPC for Dark Matter Detection

LUX: The next stage(s) Multi-tonne LXe TPC s (DM08, Marina del Rey, 21 Feb 08)

Recent Advances in Bubble-Assisted Liquid Hole-Multipliers in Liquid Xenon

Results from DarkSide-50 with underground argon

DARK MATTER SEARCH AT BOULBY MINE

Nuclear Recoil Scintillation and Ionization Yields in Liquid Xenon

Detecting low energy recoils with Micromegas

The XENON dark matter search. T. Shutt CWRU

Testing the Purity Monitor for the XENON Dark Matter Search

mean free path stopping power absorption coefficient detected recoil rate detected 0νββ events

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

X-ray ionization yields and energy spectra in liquid argon

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

The Search for Dark Matter, and Xenon1TP

Direct detection: results from liquid noble-gas experiments

WIMP Dark Matter Search with XENON and DARWIN

Gamma-Ray Polarimetry in the Pair Production Regime

Proportional Counters

Status of KIMS-NaI experiment

Status of the XENON100 Dark Matter Search

PoS(TIPP2014)033. Upgrade of MEG Liquid Xenon Calorimeter. Ryu SAWADA. ICEPP, the University of Tokyo

Recent results from the UK Dark Matter Search at Boulby Mine.

Charge readout and double phase

Rn assay and distillation purification

Beam diagnostics: Alignment of the beam to prevent for activation. Accelerator physics: using these sensitive particle detectors.

Xenon Compton Telescopes at Columbia: the post LXeGRIT phase. E.Aprile. Columbia University

Studies of Hadron Calorimeter

PHYS 3446 Lecture #12

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Direct Dark Matter Search with Noble Liquids

Status and Sensitivity Projections for the XENON100 Dark Matter Experiment

arxiv: v1 [physics.ins-det] 31 Oct 2015 Alden Fan 1

LIQUID XE DETECTOR FOR MU E GAMMA SEARCH

arxiv: v2 [physics.ins-det] 26 Oct 2015

Recent Advances in Bubble-Assisted Liquid Hole-Multipliers in Liquid Xenon

Transcription:

The Dual-Phase Liquid Xenon Time Projection Chamber (TPC) of Münster Calibration and Safety Aspects Schule für Astroteilchenphysik 2017 10.10.2017

Properties of Xenon as Detector Material Noble gas characterized by: High atomic number Z = 54 Atomic weight Ā = 131.30 u Density (liquid xenon) ρlxe = 3 g/cm³ Boiling point -108.1 C (1 bar) Freezing point -111.8 C (1 bar) Operation at -100 C, 2 bar Transparent to own scintillation light gaseous Self-shielding (absorption of higher energy photons) Bad news: Xenon is expensive! gaseous 2

Signal Generation with Xenon Excitation process: Processes after interaction: Excitation Ionization Generation of ions and free electrons Heat Emission of 178 nm scintillation light * * Xe + Xe + Xe Xe2 + Xe Xe *2 2 Xe + h ν Ionization process: Xe + + Xe Xe +2 Xe +2 + e - Xe** + Xe Xe ** Xe* + heat Xe *+ Xe + Xe Xe*2 + Xe * Xe 2 2 Xe + h ν 3

Working principle of Dual-Phase Liquid Xenon TPCs Two electric fields between cathode, gate and anode Top and bottom PMTs detect light Signal generation: PMTs Incoming particle S1 signal: Xe-dimers are created via excitation and ionization light emission S2 signal: Electrons are drifted to gate via Edrift and extracted via Eextraction light emission via electrolumniscence PMTs L. Althüser, GEANT4 simulations of the Muenster dual phase xenon TPC, Bachelor thesis, 2015 4

Working principle of Dual-Phase Liquid Xenon TPCs S1: mainly seen by bottom PMTs S2: mainly seen by top PMTs Energy reconstruction by using anti-correlated S1 and S2 PMTs Coincidence determination & correct energy estimation only with low concentration of e.g. O2, H2O,... 3d position reconstruction z: S1-S2 time difference & electron drift velocity drift length xy: hit pattern of PMTs PMTs L. Althüser, GEANT4 simulations of the Muenster dual phase xenon TPC, Bachelor thesis, 2015 5

Design of the Münster TPC Designed originally for monitoring purity of XENON1T Xenon filling by guiding xenon gas slowly into cryostat Gaseous xenon cooled to -100 C by coldhead liquefaction Vacuum vessel for thermal insulation (high vacuum) Gas circulation through hot zirconium getter by pump reduce electronegative impurities J. Schulz, Design of a 2-Phase Xenon Time Projection Chamber for Electron Drift Length Measurement, Diploma thesis, 2011 6

7 Design of the Münster TPC Basic Design Diameter 8 cm, height 17 cm (i.e. drift length) Maximum mass of 2.6 kg xenon Cylindrical polytetraflourethylene (PTFE) container Highly reflective Fitting high purity demands Low electric field distortion by PTFE (ɛr, LXe = 1.88; ɛr, PTFE = 2.1) 14 Hamamatsu R8520-06-Al 1 PMTs (same as XENON100) J. Schulz, Design of a 2-Phase Xenon Time Projection Chamber for Electron Drift Length Measurement, Diploma thesis, 2011

8 Design of the Münster TPC Basic Design Diameter 8 cm, height 17 cm (i.e. drift length) Maximum mass of 2.6 kg xenon Cylindrical polytetraflourethylene (PTFE) container Highly reflective Fitting high purity demands Low electric field distortion by PTFE (ɛr, LXe = 1.88; ɛr, PTFE = 2.1) 14 Hamamatsu R8520-06-Al 1 PMTs (same as XENON100) J. Schulz, Design of a 2-Phase Xenon Time Projection Chamber for Electron Drift Length Measurement, Diploma thesis, 2011

9 Design of the Münster TPC Electric Field Design High Voltage: Cathode: -8.5 kv (i.e. Edrift = 0.5 kv/cm) Anode: 2.5 kv (i.e. Eextraction = 5 kv/cm) Annular electrodes for improved field homogenity Electric fields in xenon: Electron extraction yield dependent on field strength (Münster TPC: ~70 %) Electron drift velocity dependent on field strength (Münster TPC: < 2 mm/µs) Increased electric field feasible! J. Schulz, Design of a 2-Phase Xenon Time Projection Chamber for Electron Drift Length Measurement, Diploma thesis, 2011

10 Design of the Münster TPC Filling Height Importance of liquid level: PMTs Electron extraction efficiency dependent on field strength Field strength highest between gate and anode Highest signal rate there! Current project! Level meters Cylindrical capacitors from bottom to top of TPC Change of filling height change of capacity: PMTs D. Schulte, Capacitance-Based Levelmeter Read-Out for the Münster Dual Phase Xenon Time Projection Chamber, Bachelor thesis, 2016

Design of the Münster TPC Critical Devices Gas system Pressure in TPC limited by rupture disc Prevent blocking of pump Slow Control Monitoring temperature, pressure, high voltage, gas flow cia LabView crio system Sends out mail and SMS alarms, if certain parameters out of range Shifters: Manual protocolling of certain parameters and device states Emergency prevention Date Stability Liq N2 Michael 201710-02 ok ok mm Alex 201710-09 P2 oscill. ok af Kevin 201710-16 ok Refill! kg Sign... NOT OK? Uninterruptible power supply... Shifter ALARM! 11

Light Collection Efficiency (LCE), Electron Lifetime (EL), Light Yield (LY) LCE: S1 generation not homogenous, as shown by LCE map Deeper generated S1 are bigger EL: Electrons catched by impurities (e.g. O2) S2 from deeper S1 events are smaller LY: Assigned energy per pe Use Kr-83m source for calibration Energy of 32.2 kev and 9.4 kev (with 156 ns delay) see talk of M. Wigard (4e) Simulated LCE map for 7 ev photons measured with bottom PMTs L. Althüser, GEANT4 simulations of the Muenster dual phase xenon TPC, Bachelor thesis, 2015 12

Outlook Safety enhancement Liquid level adjustment Energy calibration with Kr-83m Light collection efficiency S1 correction Electron lifetime S2 correction Light yield Corrected energy estimation Use other sources (e.g. Cs-137 with 662 kev photons) 13

Thank you for your attention! 14

Backup 15

Purity Aspects Electron lifetime Electron lifetime τ: mean time before attachement Electron attachement rate constant k dependent on field strength and impurity Exponential electron reduction by impurities: electronegative molecules, e.g. N2O, O2, Purification by hot metal getter XENON1T: τ 450 µs (mean) Münster: electron lifetime not yet measured E. Aprile, T. Doke, Liquid Xenon Detectors for Particle Physics and Astrophysics, 10.1103/RevModPhys.82.2053, 2009 16

Purity Aspects Photon absorption by impurities E. Aprile, T. Doke, Liquid Xenon Detectors for Particle Physics and Astrophysics, 10.1103/RevModPhys.82.2053, 2009 17

Electric Fields in Xenon Extraction yield of generated electrons from liquid to gaseous xenon dependent on field strength 100 % at Eextraction > 10 kv/cm Electron drift velocity dependent on field strength Saturation at 3-10 kv/cm E. Aprile, T. Doke, Liquid Xenon Detectors for Particle Physics and Astrophysics, 10.1103/RevModPhys.82.2053, 2009 18

Electric Fields in Xenon Extraction yield of generated electrons from liquid to gaseous xenon dependent on field strength 100 % at Eextraction > 10 kv/cm Electron drift velocity dependent on field strength Saturation at 3-10 kv/cm E. Aprile, T. Doke, Liquid Xenon Detectors for Particle Physics and Astrophysics, 10.1103/RevModPhys.82.2053, 2009 19

20 Signal Chain Trigger on S2-signals: Amplitude Threshold = 150 ADC (1.3 pe) Time threshold = 30 samples (300 ns) Recording of 2k samples after and 14k samples before trigger Time: 1 sample 10 ns 1 Event contains 16k samples, i.e. 160 µs Drift length: 17 cm; e- drift velocity: 2 mm/µs Maximum drift time 85 µs

Processor for Analyzing XENON (PAX) C. Wittweg, XENON100 Dark Matter Search with the PAX Raw Data Processor for XENON1T, Master thesis, 2016 21

Processor for Analyzing XENON (PAX) Pulse area needs 5 sigma over baseline to be declared as hit Coincident hits are summed to peaks If lone hits occur, channels are marked as suspicious (reduction of noise) Peaks are classified as S1 (e.g. area < 50 pe, width < 100 ns) S2 (e.g. area > 50 pe, width > 75 ns) S1 and S2 signals then get paired to interactions if S1 arrives before S2 22

Processor for Analyzing XENON (PAX) S1 S2 23