All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems

Similar documents
Agilent All Ions MS/MS

MassHunter TOF/QTOF Users Meeting

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

MassHunter Software Overview

Agilent MassHunter Profinder: Solving the Challenge of Isotopologue Extraction for Qualitative Flux Analysis

Application Note. Authors. Abstract. Introduction. Environmental

Agilent TOF Screening & Impurity Profiling Julie Cichelli, PhD LC/MS Small Molecule Workshop Dec 6, 2012

Die Nadel im Heuhaufen

MassHunter METLIN Metabolite PCD/PCDL Quick Start Guide

High-Throughput Protein Quantitation Using Multiple Reaction Monitoring

Agilent MassHunter Quantitative Data Analysis

Rapid Pesticide Screening and Identification Using the High Resolution All Ions MS/MS Technique

Making Sense of Differences in LCMS Data: Integrated Tools

Cerno Bioscience MassWorks: Acquiring Calibration Data on Agilent GC/MSDs

LC/Q-TOF Workflows for Comprehensive Micropollutant Analysis

The new Water Screening PCDL

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

WADA Technical Document TD2003IDCR

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Multi-residue analysis of pesticides by GC-HRMS

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

A Q-TOF Generated, Metabolomics- Specifi c LC/MS/MS Library Facilitates Identifi cation of Metabolites in Malaria Infected Erythrocytes

Understanding Your Spectra Module. Agilent OpenLAB CDS ChemStation Edition

Agilent METLIN Personal Metabolite Database and Library MORE CONFIDENCE IN COMPOUND IDENTIFICATION

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

An Effective Workflow for Impurity Analysis Incorporating High Quality HRAM LCMS & MSMS with Intelligent Automated Data Mining

Application Note. Edgar Naegele. Abstract

Agilent 6400 Series Triple Quadrupole LC/MS/MS Users Session

Extend Your Metabolomics Insight!

Key Words Q Exactive, Accela, MetQuest, Mass Frontier, Drug Discovery

Screening for Hundreds of Pesticide Residues Using a GC/Q-TOF with an Exact Mass Pesticide Database in Food

Agilent MassHunter Quantitative Data Analysis

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Metabolomics Batch Data Analysis Workflow to Characterize Differential Metabolites in Bacteria

Analyst Software. Peptide and Protein Quantitation Tutorial

Compounding insights Thermo Scientific Compound Discoverer Software

Characterization and Classification of Heroin from Illicit Drug Seizures Using the Agilent 7200 GC/Q-TOF

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

MS n Analysis With Fast Polarity Switching in the Agilent 1100 Series LC/MSD Trap SL. Application Note. Christine Miller Agilent Technologies

Agilent ESI and APCI sources: for polar to non-polar compounds

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Analysis of Biomarkers in Crude Oil Using the Agilent 7200 GC/Q-TOF

Analysis of Extractable and Leachable (E&L) Compounds Using a Low-Energy EI-Capable High Resolution Accurate Mass GC/Q-TOF

New Dynamic MRM Mode Improves Data Quality and Triple Quad Quantification in Complex Analyses

The ultratrace determination of iodine 129 in aqueous samples using the 7700x ICP-MS with oxygen reaction mode

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Information Dependent Acquisition (IDA) 1

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Screening for Water Pollutants With the Agilent SureTarget GC/MSD Water Pollutants Screener, SureTarget Workflow, and Customized Reporting

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Screening and Quantitation of 240 Pesticides in Difficult Food Matrixes Using the Agilent 6545 Q-TOF LC/MS System

Agilent 6400 Series Triple Quadrupole Users Workshop. MH QQQ Users workshop 2/21/2014 1

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

Accurate Mass Analysis of Hydraulic Fracturing Waters

GAS CHROMATOGRAPHY MASS SPECTROMETRY. Pre-Lab Questions

A Strategy for an Unknown Screening Approach on Environmental Samples Using HRAM Mass Spectrometry

The Agilent 6545 Q-TOF LC/MS System THE ANSWERS YOU NEED: BETTER, FASTER, EASIER

Increasing Speed of UHPLC-MS Analysis Using Single-stage Orbitrap Mass Spectrometer

Using the ACD/MS Manager Software with Agilent 1100 Series LC/MS Systems. Application Note

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

TOMAHAQ Method Construction

Identification and Quantitation of Pesticides in Chamomile and Ginger Extracts Using an Agilent 6460 Triple Quadrupole LC/MS system with Triggered MRM

Guide to Peptide Quantitation. Agilent clinical research

Confirmation of In Vitro Nefazodone Metabolites using the Superior Fragmentation of the QTRAP 5500 LC/MS/MS System

A Strategy for an Unknown Screening Approach on Environmental Samples using HRAM Mass Spectrometry

Automated and accurate component detection using reference mass spectra

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

TOF/QTOF Users Meeting. Jim Lau, Agilent Technologies.

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

Accelerating the Metabolite Identification Process Using High Resolution Q-TOF Data and Mass-MetaSite Software

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Quantitation of Cystine and Identification of Related Metabolites in White Blood Cells Using a High Resolution Accurate Mass LC/MS Approach

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Analysis of Ethanol and Isotopomers by 240 Quadrupole Ion Trap GC/MS

Agilent G3212 GC-APCI Source

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

Highly Sensitive and Rugged GC/MS/MS Tool

Using TOF for Screening and Quantitation of Sudan Red Colorants in Food Application

Powerful Scan Modes of QTRAP System Technology

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Determination of EU-Banned Disperse Dyes by LC/MSD TOF Application

Thermo Scientific Pesticide Explorer Collection. Start-to-finish. workflows for pesticide analysis

SRM assay generation and data analysis in Skyline

Computer-assisted analysis of complex natural product extracts

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

The 5975 inert MSD Benefits of Enhancements in Chemical Ionization Operation Technical Note

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

The Analysis of Organophosphate Pesticides by LC/MS Application

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

Transcription:

All Ions MS/MS: Targeted Screening and Quantitation Using Agilent TOF and Q-TOF LC/MS Systems Technical Overview Introduction All Ions MS/MS is a technique that is available for Agilent high resolution TOF and Q-TOF LC/MS instruments. All Ions MS/MS uses the Agilent proprietary Personal Compound Database and Libraries (PCDLs) to identify compounds with information from their molecular and fragment ions. The PCDLs are content rich and include accurate mass information for thousands of compounds. The incorporation of All Ions MS/MS processing tools into MassHunter means that compound identification is rigorous, and can be easily reviewed. As a result, All Ions MS/MS analysis decreases method setup time, increases throughput, and enables confident, high sensitivity quantitative, and qualitative analysis on a single instrument, in a single analytical run.

Identification by Correlating Precursor to Fragment Ions In the All Ions MS/MS technique, high resolution accurate mass (HRAM) data is acquired using different conditions: (1) with a low value for the fragmentor voltage or collision energy and (2) one or multiple high energy values. The low energy spectra predominantly show just the molecular (or precursor) ions for the compounds and the high energy spectra provide the precursors plus their fragment ions. This analytical method is easy to set up using the MassHunter Workstation Acquisition for TOF and Q-TOF (rev. B.5.1 and later). Figure 1 shows a new feature in the Acquisition software, an Experiment # field allows different values of parameters during a time segment. For example, a user can set up Experiment 1 with a collision energy of V, then Experiments 2 and 3 with collision energies of 2 and 4 V. The result of alternating the fragmentor voltage or collision energy is a data file with a low energy channel that contains predominantly precursor ions and one or several high energy channels that contain precursor and fragment ions. Figure 2A shows a spectrum of simazine with a collision energy of V where the precursor ion at 22.8584 is prominently featured. Figure 2B shows an averaged spectrum of collision energies at both 2 and 4 V which contains the precursor as well as several fragment ions. New Experiment # field Fragmentor or CE can be changed Figure 1. Q-TOF tab in the MassHunter Acquisition Method Editor. Up to four experiments with different values of collision energy (Q-TOF) or Fragmentor voltage (TOF or Q-TOF) can be configured within one time segment. 1 5 3.5 A 3. 2.5 2. 1.5 1..5 1 4 4. 3.5 3. 2.5 2. 1.5 1..5 B 52.1886 5 67.2961 94.48 14.115 121.585 143.3261 174.5457 22.8584 22.8584 6 7 8 9 1 11 12 13 14 15 16 17 18 19 2 21 Figure 2. A) The precursor ion and its isotopic cluster for the herbicide simazine are in red. B) Shows an average of spectra acquired at collision energies 2 and 4 V. The precursor at 22.8584 is still present, but the fragment ions have also been acquired. 2

The All Ions MS/MS technique works in the MassHunter Qualitative Analysis Software by correlating the elution profile of the precursor ion in the low energy channel to those of the fragments generated under higher energy conditions. For example, Figure 3 shows the precursor (in red) and a fragment at m/z 132.3221 with qualifying coelution (in green). This is achieved by obtaining all the fragment information from existing compounds in the Agilent PCDL, which contains MS/MS spectra acquired at several different collision energies 1. In addition, PCDLs also contain compound information including the name, formula, accurate mass, structure, and database identifiers such as the CAS number. The PCDL is used to select potential fragment ions which are then analyzed for coelution with the precursor ion. 1 4 3.6 3.2 2.8 2.4 2. 1.6 1.2.8.4 85 94.48 121.585 14.115 132.3221 143.3261 158.9639 174.5457 186.816 22.8564 95 15 115 125 135 145 155 165 175 185 195 25 Figure 3. The precursor ion for simazine 22.8564 m/z (in red) is correlated to its fragment ion 132.3221 m/z (in green) using the All Ions MS/MS technique. Find by Formula The All Ions MS/MS technique (Figure 4) is an extension of Agilent s unique Find by Formula (FBF) algorithm in MassHunter Qualitative Analysis software. FBF starts with the formula of a compound (for example, from the PCDL) and calculates the monoisotopic mass and isotope pattern. It then pulls out Extracted Ion Chromatograms (EICs) from the data file based on the most abundant isotopes for each selected charge carrier, and extracts the averaged spectra from the top 5% of the integrated peaks. Thus, if the compound is present in the data file, it should generate chromatographic peaks for each of its major molecular ions. Extract EICs from data file based on formula Extract spectra of the most abundant isotope peaks Examine spectra for candidate ion species Calculate probability match score and accept/reject Figure 4. FBF uses a formula to calculate the monoisotopic mass and its isotopes for all selected charge carriers, extracting EICs, and then extracting peak spectra for chromatographic peaks. The peak spectra are then searched for ions associated with each compound and a probability match score is assigned. Compounds that exceed a user set threshold are labeled as identified in MassHunter Qualitative Analysis. 3

The extracted mass spectra from the peak are examined for candidate ion species based on the compound s formula. A probability match score is calculated for each species based on its mass, isotopic abundance and spacing (Figure 5). If a compound passes the match score filter, it is labeled as identified. FBF is fast and can examine a data file against an accurate mass database (CSV, PCD or PCDL) with thousands of formulas in a few minutes. Fragment Confirmation In the All Ions MS/MS technique, the FBF algorithm is enhanced with the additional step of fragment confirmation using one or several high energy channels. If the compound has at least one MS/MS spectrum in the PCDL, the most abundant product ions in the library spectra are extracted as EICs from the respective high energy channel. For example, Figure 6A displays the MS/MS library spectrum for simazine at 2 V collision energy from the Pesticide PCDL. Figure 6B shows a high energy spectrum from a sample that contains simazine. Using the PCDL, the software was able to locate fragments including those at m/z 14. and 132.3 despite much more abundant extraneous ions at m/z 94.4 and 121.5. 1 5 6 5 4 3 2 1 213.794 214.8533 215.7696 216.813 212.5 213. 213.5 214. 214.5 215. 215.5 216. 216.5 217. 217.5 Figure 5. Identification of a compound using FBF makes use of three characteristics of the precursor ion s isotopic cluster: the accurate mass of each isotope, its abundance (denoted by the red boxes), and its spacing relative to the other isotopes. Abundance 1 9 8 7 6 5 4 3 2 1 Library spectrum A 96.5563 53.61 14.1 47.94 124.8692 95.87 132.323 1. 138.7742 2.79 146.228 2.6 166.1872 15.9 174.549 21.18 22.854 92.62 95 1 15 11 115 12 125 13 135 14 145 15 155 16 165 17 175 18 185 19 195 2 25 21 1 4 3.5 B 121.585 3. 2.5 2. 94.48 1.5 1. 14.115 132.3221 22.8564.5 89.5991 143.3261 158.9639 174.5457 186.816 85 95 15 115 125 135 145 155 165 175 185 195 25 Figure 6. A) Shows an MS/MS library spectrum for simazine acquired at a 2 V collision energy. It shows the product ions for the compound including m/z 14. and 132.3. These ions are visible (in green) in the bottom spectrum (B) of the high energy channel despite more abundant ions at m/z 94.4 and 121.5. 4

The fragments from MS/MS spectra in the PCDL are extracted as EICs and overlaid with the precursor ion EIC. If no MS/MS spectra are available for a compound in the PCDL, then the most abundant fragments in the average of all the high energy channel spectra are extracted as EICs and overlaid. These overlaid EIC are evaluated using an unique coelution score parameter. The coelution score is derived from a technique which is similar to Peak Purity 2 used in UV chromatography, in that the software calculates a number based on abundance, peak shape (symmetry), peak width, and retention time. The normalized ratio of the fragment ions to the precursor ion intensity are plotted over the retention time and made available to the user for inspection in a Coelution Plot. Figure 7A shows the overlaid EICs for simazine while Figure 7B shows a Coelution Plot with all ions at the same apex (5.571 minutes). Ratio fragment ion/precursor ion 4. 3. 2. 1. 1 1 1.1 A 5.4 5.42 5.44 5.46 5.48 5.5 5.52 5.54 5.56 5.58 5.6 5.62 5.64 5.66 5.68 5.7 5.72 5.74 5.76 5.78 B 5.4 5.42 5.44 5.46 5.48 5.5 5.52 5.54 5.56 5.58 5.6 5.62 5.64 5.66 5.68 5.7 5.72 5.74 5.76 5.78 Acquisition time (min) Figure 7. A) Shows EICs for simazine, with the precursor ion in blue and its fragment ions in other colors. All ions have the same chromatographic apex. B) Shows the Coelution Plot for simazine, which plots the ratio of the normalized fragment ion intensity over the precursor ion intensity over the retention time. All fragment ions exhibit ratios of approximately 1 across the middle of the precursor peak indicating strong coelution. This provided confirmation for the identification of simazine in the sample. 5

Users can set up parameters for the All Ions MS/MS technique in a new tab in the FBF area of MassHunter Qualitative Analysis called Fragment Confirmation (Figure 8). The tab allows the user to specify whether to use a spectral library or average fragment spectrum, and how many of the most abundant ions to extract. Limits can also be set for fragment ion EICs based on retention time difference, minimum signal-to-noise (S/N) ratio, and coelution score. Once FBF has been run with fragment confirmation, users can view results for each compound in the Compound Identification Results pane (Figure 9). The name of the compound, its chemical formula, and probability match score from FBF is found at the top. The individual fragment ions used for the identification are listed below with their coelution score, collision energy (CE), and whether the fragment is qualified or not. If a fragment is not qualified, a reason is given, for example, Low S/N ratio. Figure 8. Select the Fragment Confirmation tab from the FBF area in MassHunter Qualitative Analysis. Click Confirm with fragment ions to modify FBF to perform the All Ions MS/MS technique. Users can decide whether to confirm with a spectral library (PCDL) or to use the most abundant ions from the average fragment spectrum. They can set the number of ions to use and set limits on qualifying the EICs, as well as set the minimum qualified fragments to confirm a compound s identity. Figure 9. Shows the Compound Identification Results for Chloroxuron. The first line of the table indicates the best compound match found with its name, formula, and probability matching score from FBF. The lower table shows that five fragment ions were evaluated with their coelution scores, collision energies, and whether they were qualified or not. Three fragment ions were qualified while two were rejected with a reason. 6

Viewing Compound Details It is possible to inspect All Ions MS/MS results quickly in the new Compound Details View (Figure 1). Users can scroll through all compounds in the screen and efficiently view the library match result, both MS and fragment spectra, overlaid EICs and Coelution Plots. At this point, the user will have developed a qualitative method for the identification of compounds using the All Ions MS/MS technique. Users can continue to analyze samples without having to access the PCDL s MS/MS spectra since the information about the fragment ions is saved with the MassHunter Qualitative Analysis method. New compounds can easily be added to the screening through addition to the PCDL followed by data reprocessing. This important capability means that subsequent data re-interrogation is simple and available without sample re-analysis. Compound list Library match results Overlaid chromatograms MS spectrum Coelution plot Fragment spectrum Figure 1. By selecting Compound Details View in MassHunter Qualitative Analysis, users are able to quickly and effectively review the All Ions MS/MS results. Starting at the top of the Compound List, they can move from compound to compound to confirm results and review details for rejected compounds. 7

Quantitative Analysis Once the review in Compound Details View is complete, the data can be exported to MassHunter Quantitative Analysis Software using a Compound Exchange Format (CEF) file. The CEF file contains information necessary to set up a quantitative method: compound name, retention time, precursor ion, fragment ions (to create qualifiers), collision energy, and relative abundances. This significantly speeds up the creation of a quantitative data processing method. The MassHunter Quantitative Analysis Software automatically selects the major precursor and fragment ions with a relative abundance above 1% for each compound, saving tedious manual processing. Fragment ions with different collision energies or fragmentor voltages can be selected and used by the software (Figure 11). Optionally, one of the isotopes of the precursor ion from the low energy channel can be used as a qualifier as well, see the product ion at m/z 24.828 in Figure 11. The Quantitative Analysis software extracts chromatograms for the quantifier (target), qualifier ions, and isotopic cluster of the molecular ion. The isotope pattern can be confirmed by viewing an overlay with the theoretical pattern (Figure 12). Figure 11. Method setup in Agilent MassHunter Quantitative Analysis. Compound details are imported with its name, precursor ion, product ions, and relative response ratio. Note that the collision energies for each of the qualifiers are different, giving users more flexibility for the ions used. The ion at m/z 24.828 with V collision energy is an isotope of the precursor ion and is used as a qualifier for further confirmation. 1 5 3. 2.8 2.6 2.4 2.2 2. 1.8 1.6 1.4 1.2 1..8.6.4.2 -.2 5.564 min 4.8 5. 5.2 5.4 5.6 5.8 6. 6.2 6.4 Acquisition time (min) 1 5 3.2 3. 2.8 2.6 2.4 2.2 2. 1.8 1.6 1.4 1.2 1..8.6.4.2 -.2 22.858, 124.869, 68.243, 24.828 Ratio = 2.7 Ratio = 21.6 Ratio = 31.1 4.8 5. 5.2 5.4 5.6 5.8 6. 6.2 6.4 Acquisition time (min) 1 6 1.1 1..9.8.7.6.5.4.3.2.1 Mass match score = 99.2 22.858 22 23.876 24.825 25.847 23 24 25 Figure 12. Extracted ion chromatograms of the quantifier (target) ion, qualifiers and the isotopic cluster of the molecular ion. The theoretical isotope abundance pattern is denoted by the red boxes. 8

Conclusions All Ions MS/MS is a technique that increases sample throughput, provides both qualitative and quantitative information, and minimizes the cost of analyses. This workflow is much faster than setting up quantitative analyses with triple quadrupole LC/MS instruments which requires many hours of entering compound information and choosing high abundance qualifier ions. Since the data acquired with the All Ions MS/MS technique is full scan accurate mass data, it can be re-interrogated for additional compounds simply by adding them to the method, no re-acquisition is required. With All Ions MS/MS, users can confidently carry out both targeted qualitative screening and rapid quantitative analysis using a single instrument, in a single injection. References 1. MassHunter Personal Compound Database and Library Manager Quick Start Guide, Publication number G3336-914, February 211. 2. Hans-Jürgen P. Sievert, Anton C.J.H. Drouen, Spectral matching and peak purity in Diode Array Detection in High Performance Liquid Chromatography, New York: Marcel Dekker, 1993. For More Information 5991-2295EN - Application Note on All Ions MS/MS with Pesticides 5991-2319EN - Application Note on All Ions MS/MS with Forensics All Ions MS/MS Workflow Guide 9

www.agilent.com/chem For Research Use Only. Not for use in diagnostic procedures. Information, descriptions, and specifi cations in this publication are subject to change without notice. Agilent Technologies shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance or use of this material. This information is subject to change without notice. Agilent Technologies, Inc., 213 Published in the USA, June 1, 213 5991-2465EN