ICARUS Status and Plans

Similar documents
ICARUS T600 experiment: latest results and perspectives

ICARUS experiment - status and perspectives

Sterile neutrinos in Icarus and Borexino. Paola Sala (Icarus) Gioacchino Ranucci (Borexino) INFN Milano

P. Sala For the ICARUS Collaboration. Slide: 1

ICARUS at FNAL: a proposal. Carlo Rubbia, GSSI INFN, Italy

- ICARUS status and near future

Muon momentum measurement in ICARUS-T600 LAr-TPC via multiple scattering in few-gev range

arxiv: v4 [hep-ex] 19 Feb 2013

Status of ICARUS T600

1. The ICARUS T600 detector

arxiv: v1 [hep-ex] 1 Oct 2015

A. Fava for the ICARUS Collaboration I.N.F.N. Padova

Measurement of the neutrino velocity with the ICARUS detector at the CNGS beam

Status and early events from ICARUS T600

The Short Baseline Neutrino Program at Fermilab

Latest Results from the OPERA Experiment (and new Charge Reconstruction)

Results from the OPERA experiment in the CNGS beam

ICARUS and the status of LAr technology

Performance of the ICARUS T600 detector

RECENT RESULTS FROM THE OPERA EXPERIMENT

The ICARUS Project FRONTIERS IN CONTEMPORARY PHYSICS II. Vanderbilt University, March 5-10, Sergio Navas (ETH Zürich) " Atmospheric neutrinos

Jonathan Asaadi Syracuse University

Upgrade of the ICARUS T600 Time Projection Chamber

First neutrino beam and cosmic tracks. GDR neutrino

PoS(HEP2005)177. Status of the OPERA experiment. Francesco Di Capua. Universita Federico II and INFN.

The CNGS neutrino beam

A. Chukanov On behalf of OPERA collaboration JINR, Dubna TAUP 2011, Munich, 5-9 september, 2011

arxiv:hep-ex/ v1 2 Jun 2006


Recent T2K results on CP violation in the lepton sector

Recent Results from Alysia Marino, University of Colorado at Boulder Neutrino Flux Workshop, University of Pittsburgh, Dec 6 8,2012

Long Baseline Neutrinos

The CERN-Gran Sasso Neutrino Program

K2K and T2K experiments

The Marvellous Neutrino. Carlo Rubbia CERN, Geneva, Switzerland Institute for Advanced Sustainability Studies Potsdam, Germany

ICARUS at FNAL. Proposal. The ICARUS Collaboration

Results from the OPERA experiment in the CNGS beam

arxiv: v1 [hep-ex] 11 May 2013

QE or not QE, that is the question

NOE, a Neutrino Oscillation Experiment at Gran Sasso Laboratory

New Hadroproduction results from the HARP/PS214 experiment at CERN PS

SciBar and future K2K physics. F.Sánchez Universitat Aútonoma de Barcelona Institut de Física d'altes Energies

The CNGS project. Pasquale Migliozzi INFN - Napoli

Measuring the neutrino mass hierarchy with atmospheric neutrinos in IceCube(-Gen2)

Neutrino Oscillations Physics at DUNE

Sterile Neutrino Experiments at Accelerator

HARP (Hadron Production) Experiment at CERN

Liquid Argon TPCs for future neutrino oscillation experiments

Long Baseline Neutrino Experiments

Application of GLoBES: GLACIER on conventional neutrino beams

Updated results of the OPERA long baseline neutrino experiment

PMT Signal Attenuation and Baryon Number Violation Background Studies. By: Nadine Ayoub Nevis Laboratories, Columbia University August 5, 2011

Publications of Francesco Arneodo: journal articles

MINOS. Physics Program and Construction Status. Karol Lang The University of Texas at Austin. YITP: Neutrinos and Implications for Physics Beyond

MINOS. Luke A. Corwin, for MINOS Collaboration Indiana University XIV International Workshop On Neutrino Telescopes 2011 March 15

Experimental results on the atmospheric muon charge ratio

PoS(NEUTEL2015)037. The NOvA Experiment. G. Pawloski University of Minnesota Minneapolis, Minnesota 55455, USA

New Results for ν µ ν e oscillations in MINOS

The HARP Experiment. G. Vidal-Sitjes (INFN-Ferrara) on behalf of the HARP Collaboration

PoS(NEUTEL2017)041. Icarus. Andrea Zani, on behalf of the ICARUS/WA104 Collaboration. CERN

PoS(EPS-HEP2017)483. The CERN Neutrino Platform. Stefania Bordoni CERN

Measurement of the neutrino velocity with the OPERA detector in the CNGS beam

CNGS neutrino beam - MODULAr project

The T2K experiment Results and Perspectives. PPC2017 Corpus Christi Mai 2017 Michel Gonin On behalf of the T2K collaboration

DUNE detector design and lowenergy reconstruction capabilities. Inés Gil Botella

PoS(NOW2016)003. T2K oscillation results. Lorenzo Magaletti. INFN Sezione di Bari

CNGS beam monitor with LVD

The US Liquid Argon Time Projection Chamber (LArTPC) experiments

MiniBooNE, LSND, and Future Very-Short Baseline Experiments

Status and Neutrino Oscillation Physics Potential of the Hyper-Kamiokande Project in Japan

Search for nu tau appearance via neutrino oscillations in the nu mu CNGS beam with the OPERA experiment

Particle production vs. energy: how do simulation results match experimental measurements?

Neutrino physics with the SHiP experiment at CERN

T2K neutrino oscillation results

Search for sterile neutrino mixing in the muon neutrino to tau neutrino appearance channel with the OPERA detector

Latest results of OPERA

NINJAExperiment: NINJA. Tsutomu Fukuda(IAR, Nagoya University) on behalf of NINJA collaboration

Neutrino Experiments: Lecture 2 M. Shaevitz Columbia University

Neutrino Scattering in Liquid Argon TPC Detectors

Perspectives of neutrino oscillation physics with long baseline beams

Results from HARP. Malcolm Ellis On behalf of the HARP collaboration DPF Meeting Riverside, August 2004

The SOX experiment. Stefano Davini (on behalf of the Borexino-SOX collaboration) Brussels, December 1 st 2017

Challenges in ν-argon scattering and new results from the MicroBooNE experiment

Neutrino mixing II. Can ν e ν µ ν τ? If this happens:

PHYS 5326 Lecture #2. Wednesday, Jan. 24, 2007 Dr. Jae Yu. Wednesday, Jan. 24, 2007 PHYS 5326, Spring 2007 Jae Yu

Measurement of Muon Momentum Using Multiple Coulomb Scattering for the MicroBooNE Experiment

Recent results from Super-Kamiokande

Hadron Production Experiments and Neutrino Beams

Detectors for astroparticle physics

The MINERnA Experiment

The OPERA Experiment

PoS(KAON13)012. R K Measurement with NA62 at CERN SPS. Giuseppe Ruggiero. CERN

ICARUS. A Second-Generation Proton Decay Experiment and Neutrino Observatory at the Gran Sasso Laboratory and The CNGS beam from CERN to Gran Sasso

The Research Activities within CERN Neutrino Platform

SHiP: a new facility with a dedicated detector for neutrino physics

Commissioning of the ATLAS LAr Calorimeter

Recent results from MiniBooNE on neutrino oscillations

The CERN Neutrino Platform. Paola Sala CERN and INFN Milano For the NP team 09/09/2016 Neutrino Platform NOW2016 1

Sensitivity of CNGS muon

NA62: Ultra-Rare Kaon Decays

Transcription:

ICARUS Status and Plans P. Sala INFN Milano For the ICARUS Collaboration Nufact 2013

The ICARUS Collaboration M. Antonello a, B. Baibussinov b, P. Benetti c, F. Boffelli c, A. Bubak k, E. Calligarich c, N. Canci a, S. Centro b, A. Cesana d, K. Cieslik e, D. B. Cline f, A.G. Cocco g, A. Dabrowska e, D. Dequal b, A. Dermenev h, R. Dolfini c, A. Falcone c, C. Farnese b, A. Fava b, A. Ferrari i, G. Fiorillo g, D. Gibin b, S. Gninenko h, A. Guglielmi b, M. Haranczyk e, J. Holeczek k, M. Kirsanov h, J. Kisiel k, I. Kochanek k, J. Lagoda j, S. Mania k, A. Menegolli c, G. Meng b, C. Montanari c, S. Otwinowski f, P. Picchi l, F. Pietropaolo b, P. Plonski n, A. Rappoldi c, G.L. Raselli c, M. Rossella c, C. Rubbia a,i,m, P. Sala d, A. Scaramelli d, E. Segreto a, F. Sergiampietri o, D. Stefan a, R. Sulej j,i, M. Szarska e, M. Terrani d, M. Torti c, F. Varanini b, S. Ventura b, C. Vignoli a, H. Wang f, X. Yang f, A. Zalewska e, A. Zani c, K. Zaremba n. a INFN Laboratori Nazionali del Gran Sasso Assergi, Italy b Dipartimento di Fisica e Astronomia, Università di Padova and INFN, Padova, Italy c Dipartimento di Fisica Nucleare e Teorica Università di Pavia and INFN, Pavia, Italy d Politecnico di Milano and INFN, Milano, Italy e Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Science, Krakow, Poland f Department of Physics and Astronomy, University of California, Los Angeles, USA g Dipartimento di Scienze Fisiche Università Federico II di Napoli and INFN, Napoli, Italy h INR RAS, Moscow, Russia i CERN, Geneva, Switzerland j National Centre for Nuclear Research, Otwock/Swierk, Poland k Institute of Physics, University of Silesia, Katowice, Poland l INFN Laboratori Nazionali di Frascati, Frascati, Italy m GSSI, Gran Sasso Science Institute, L Aquila, Italy n Institute of Radioelectronics, Warsaw University of Technology, Warsaw, Poland o INFN Pisa. Pisa, Italy

The ICARUS detector at LNGS Laboratory ICARUS T600 is the first large mass LAr-TPC (760 tons) operated underground (in Hall B of LNGS Laboratory). Exposed to CNGS n beam, taking data also with cosmic rays to study the detector capability for atmospheric n and proton decay search. In operation since May 2010 ICARUS decommissioning started on June 27 th, cryo empty on July 25 th 740 tons of LAr recovered Slide: 3

Outline Plenty of high quality data from CNGS and cosmic rays allows for physics studies, for deep investigation of all the detector technical aspects and for development of advanced reconstruction algorithms In this talk, focus will be on Validation of the muon momentum measurement with the Multiple Scattering technique Search for n m n e oscillations in the framework the LSND/MiniBooNE anomaly Slide: 4

cathode ICARUS @ LNGS: the first LARGE LAr-TPC 1.5m Hall B cryogenics (behind) LN 2 vessels readout electronics E E T300 T300 readout wire arrays Two identical T300 modules (2 TPC chambers per module) LAr active mass 476 t:; drift length = 1.5 m; E drift = 0.5 kv/cm; v drift = 1.6 3 readout wire planes at 0, ±60 53000 wires, 3 mm pitch 2 Induction planes, 1 Collection PMT for scintillation light (128 nm): (20+54) PMTs mm/ms trigger and t 0 Total energy reconstruction of events from charge integration. Full sampling, homogeneous calorimeter; excellent accuracy for contained events. Slide: 5

max drift 60 ppt O 2 equiv. ICARUS CNGS RUN (Oct 2010 Dec 2012) Exposed to CNGS n beam since 2010 October 1 st up to 2012 December 3 rd CNGS trigger: coincidence of PMT sum signals with beam extraction Total collected event statistics: 8.6 10 19 pot with a remarkable detector live-time > 93 % 2010 2011 2012 Excellent results on Lar purification LAr continuously filtered t ele > 5ms (~60 ppt [O 2 ] eq ), maximum charge attenuation at 1.5 m: 17%. Slide: 6

Measurement of muon momentum via multiple scattering In the T600 and in future LAr TPCs, a method to measure the momentum of escaping μ is needed in order to reconstruct n μ CC events Deflections due to Multiple Coulomb Scattering (MS) provide such a tool The RMS of depends on p and on the meas. error 13.6MeV p Horizontal m stopping in the T600 are an excellent benchmark Calorimetric measurement is possible The energy range (0.5-4 GeV) is perfectly matched to those of future short and long baseline experiments A sample of 130 stopping muons from CNGS n interactions in the upstream rock has been selected and analyzed RMS l X 0 l noise 3 2 Muon momentum reconstructed by calorimetric measurement for the stopping muon sample Slide: 7

3 d reco Results and brem excluded from MS Calorimetric estimate <1% Exluding the last 1.5 m of track, to really mimic escaping muons 3D reconstructed track with nodes Bremsstrahlung Filling with estimated de/dx Muon cluster used for MS Identified rays Distribution of momentum by MS p MS vs momentum by calorimetry p cal More statistics coming Extension to full CNGS sample ongoing Muon p determination by MS is possible with a resolution 10% in the momentum range of interest for future LAr TPCs Event by event ratio p MS / p cal <P MS /P Cal )>= 0.97 (P MS /P Cal ) = 0.13 Slide: 8

n μ n e anomalous oscillations See Carlo Giunti s talk on sterile n LSND has observed an excess of n e events in a n μ beam, 87.9 ± 22.4 ± 6.0 3.8 MiniBoone (PRL 110 (2013) 161801) event excess: antineutrino 78.4 28.5 events (2.8 ) for 200 < E QE <1250 MeV. neutrino 162 47.8 events (3:4 ) but the energy distribution is marginally compatible with a two neutrino oscillation formalism.. Slide: 9

A search for LSND effects The CNGS facility delivered an almost pure n m beam peaked in 10-30 GeV energy range (beam associated n e ~1%) at a distance L=732 km from target n μ Expected CNGS neutrino CC spectra at LNGS n e n e n μ Differences w.r.t. the LSND experiment: L/E n 1 m/mev at LSND, but L/E n 36.5 m/mev at CNGS LSND-like short distance oscillation signal averages to: sin 2 (1.27Dm 2 new L /E) ½ and <P> n m n e ½ sin 2 (2 new ) When compared to other long baseline results (MINOS,T2K) ICARUS operates in a L/E n region in which contributions from standard neutrino oscillations are not yet too relevant.. Slide: 10

Selection Event Selection of n e events n e CC eventcandidates are selected visually Fiducial volume (for shower id.) : > 5 cm from TPC walls and 50 cm downstream Energy cut: < 30 GeV 50% reduction on beam n e only 15% signal events rejected n m CC events identified by L > 250 cm primary track without had. int. n e MC event The Electron signature requires: A charged track from primary vertex, m.i.p. on 8 wires, subsequently building up into a shower; very dense sampling: every 0.02 X 0!!! Clearly separated (150 mrad) from other ionizing tracks near the vertex in at least one of 2 transverse views. Electron efficiency studied with events from a MC (FLUKA) reproducing in every detail the signals from wire planes: h = 0.74 ± 0.05 (h = 0.65 ± 0.06 for intrinsic n e beam due to its harder spectrum). Slide: 11

Event rates First results published in Eur. Phys. J. C 73 (2013). New analysis presented here refers to 1995 n interactions (6.0 10 19 pot statistics). The expected number of n e events due to conventional sources in the energy range and fiducial volume are: 5.7 ± 0.8 events due to the estimated ν e beam contamination; 2.3 ± 0.5 n e events due to the oscillations from sin 2 ( 13 ) = 0.0242 ± 0.0026; 1.3 ± 0.1 n t with t e events from the three neutrino mixing standard model predictions, Giving a total of 9.3 ± 0.9 expected events Taking into account the selection efficiency, the expected number of e- events from intrinsic ν e beam, 13 ~9 0 and n m -n t oscillations is then 6.4±0.9 (syst. only). The measurement error is dominated by statistics Slide: 12

Sources of systematic errors : 1 n e component in the CNGS beam: from MC predictions on particle production and transport Normalization errors cancel out in the n e / n μ ratio Comparison of FLUKA predictions with NA49 data for primary p ± (on C) and K ± production (on free proton). pp -> K ± pc -> p ± p + K + K - p - ~5% extimated uncertainty on particle production mostly based on NA49 angle integrated data at 158 GeV (3.8% exp. systematics), assuming the X F scaling between reality and MC is the same within few %. Conservative estimate on n e / n μ : 10% Work in progress for next analyses Slide: 13

Sources of systematic errors : 2 Effect of 30 GeV energy cut on background estimate: MC: m=2.37 MeV/cm; RMS=1.37 data: μ=2.32 MeV/cm; RMS=1.31 Test of MC/data agreement on de/dx from long muon tracks de/dx in 3 mm track segments (3D), after removing rays and e.m. cascades MC data agreement on the level of 2% signal/noise from Landau + gaussian 10 MC - Data comparison of total energy deposited in identified n μ CC events Agreement data-mc on de/dx and total energy better than 2.5% Applied to n e spectrum uncertainty < 10% Slide: 14

e/g separation and p 0 reconstruction in ICARUS p 0 reconstruction: E k = 102 ± 10 MeV θ p π o = 912 ± 26 MeV/c m π o = 127 ± 19 MeV/c² θ = 28.0 ± 2.5º MC: single electrons (Compton) MC: e + e pairs (g conversions) data: EM cascades (from p 0 decays) 1 m.i.p. 2 m.i.p. 1 m.i.p. 2 m.i.p. E k = 685 ± 25 MeV Sub-GeV E range MC Collection Mgg: 133.8±4.4(stat)±4(syst) MeV/c 2 Unique feature of LAr to distinguish e from g and reconstruct p 0 Estimated bkg. from p 0 in NC and n μ CC : negligible (from MC and scanning) Slide: 15

4 n e events observed n e events in 1995 n interactions 1 In the sample of 1995 n events, 4 were identified as n e CC The expected backgr. being 6.4±0.9 (1) E tot = 11.5 ± 1.8 GeV, p t = 1.8 ± 0.4 GeV/c (2) E tot vis = 17 GeV, p t = 1.3 ±0.18 GeV/c (3) E tot = 27 ± 2.0 GeV, p t = 3.5 ± 0.8 GeV/c (4) E tot = 14 ± 1 GeV, p t = 1.5 ±0.1 GeV/c In all events: single electron shower opposite to had. component in the transverse plane Slide: 16

Event n. 3 Experimental pictures of the third event with a clear electron signature The evolution of the actual de/dx from a single track to an e.m. shower for the electron shower is shown along the individual wires. The event has a total energy of ~27 GeV and an electron of 6.3 ± 1.5 GeV with a transverse momentum of 3.5 ± 0.9 GeV/c. Slide: 17

Event N.4 Fourth n e event total energy ~14 GeV electron energy 6.4 ± 0.3 GeV transverse momentum 1.2 ± 0.2 GeV/c. 3D reconstruction of primary particles in the event (red dots correspond to vertices of polygonal fit ) Slide: 18

ICARUS results on the LSND-like anomaly The first ICARUS result (Eur. Phys. J. C 73 2013) limits the window of possible parameters for LSND anomaly to a narrow region around (Dm 2 sin 2 2 ) = (0.5 ev 2-0.005), where all experiments are compatible. This analysis is based on a doubled statistics in total 6.0 x 10 19 pot and 1995 n events 4 evt observed, 6.4±0.9 expected background Limits on number of events due to LSND anomaly: 3.68 (90% CL) 8.34 (99% CL) the corresponding limits on oscillation probability are: P νμ νe 3.4 10-3 (90% CL) P νμ νe 7.6 10-2 (99% CL) Slide: 19

Antineutrino The LSND result was based on anti-neutrino events. A small ~2% antineutrino event contamination is also present in the CNGS beam According to simulations, the n μ CC event rate is (1.2 ± 0.25) % of n μ CC for E n < 30 GeV In the limiting case in which the whole effect is due to n μ, the absence of an anomalous signal gives a limit of 4.2 events at 90% CL. Corresponding to <P( n μ n e ) > 0.32 Or sin 2 (2 new ) 0.64. Slide: 20

Conclusions on n e search A major fraction of the two dimensional plot [Dm 2, sin 2 (2 )] new from the experiments sensitive to the LSND anomaly is excluded by ICARUS The ICARUS result allows to define a small region around (Dm 2,sin 2 (2θ)) = (0.5 ev 2, 0.005) in which there is 90 % CL agreement among all experiments A similar search performed at the CNGS beam by the OPERA exp. has confirmed our finding with an independent limit sin 2 (2 new ) < 7.2 10-3 There is tension between the limit sin 2 (2 new ) < 6.8 10-3 at 90% CL and < 1.52 10-2 at 99% CL of ICARUS and the neutrino lowest energy points of MiniBooNE (see also Giunti s talk) As a conclusion, the LSND anomaly appears to be still alive and further experimental efforts are required to prove the possible existence of sterile neutrinos. The recently proposed ICARUS/NESSiE experiment at the CERN-SPS neutrino beam, based on two identical LAr-TPC detectors, complemented with magnetized muon spectrometers and placed at two ( near and far ) distances from proton target, has been designed to definitely settle the origin of these n-related anomalies. Slide: 21

ICARUS at the (proposed) CERN North Area Neutrino Facility 100 GeV primary proton beam fast extracted from SPS in North Area: C-target station + two magnetic horns, 100 m decay pipe, Fe/graphite dump, followed by µ stations. Interchangeable n and anti n focussing. New CERN SPS 2 GeV neutrino facility in North Area Far position: 1600 m ICARUS-T600 detector + magnetic spectrometer Near position: 460 m 150t LAr-TPC detector + magnetic spectrometer SPSC-P347 Slide: 22

Exploring all channels: expected sensitivity e-appearance: 1 year n μ beam (left) 2 year antin μ beam (right) for 4.5 1019 pot/year, 3% syst. uncertainty n μ n e n μ n e LSND allowed region is fully explored in both cases n e n e e/m-disappearance: 1 year n μ beam (left) 1 year n μ + 2 years anti-n μ beams (right) combined anomalies : from reactor ns, Gallex and Sage experiments. In addition: Detector R&D (T150) Neutrino cross sections (huge statistcs of n e ) Event reconstruction pave the way for future LBL experiments Slide: 23

Thank you! LNGS_May2011 Slide 24

Minutes of the 108 th SPSC meeting Jan 2013: The SPSC recommends moving the ICARUS detector from LNGS to CERN during LHC LS1, to a position suitable for use as the far detector of a short baseline experiment for search for sterile neutrinos. The SPSC supports the physics cases The SPSC supports the focus of the European neutrino community on the LAr TPC technology, The SPSC recommends that future European R&D for neutrino beam physics at CERN should be made in close contact with the US groups in anticipation of cooperation on future projects. Slide: 25

Backup slides Slide: 26

3D reconstruction (example of stopping µ) NEW: Simultaneous 3D polygonal fit 2D hit-to-hit associations no longer needed Adv.High Energy Phys. 2013 (2013) 260820 T300 real event Collection view Induction 2 view Induction 1 view SPS-C_June.2013 Slide# : 27

Beam and detector systematics on n m disappearance First muon pit Results at Muon pits: data vs MC Effect of Earth B field (in 1 km decay tunnel) included in MC. Data MC Experimental uncertainties: muon detector calibration (work ongoing), density of rock in between the two pits (67 m). Spill by spill corrections for (small) horn/reflector instabilities ICARUS trigger system efficiency Selection efficiency & possible contamination from interactions in the materials around the active LAr: data and MC scanning ongoing Detector response uniformity/stability for interaction vertices. SPS-C_June.2013 Slide# : 28

Performance of the ICARUS T600 Trigger Main trigger source: scintillation light signals from PMT system integrated with low noise (RC=10 ms) preamps to efficiently exploit the 6ns fast and 1.6 ms slow components CNGS neutrino trigger: PMT-Sum signal (thr. ~100 phe) for each chamber in coincidence with CNGS Early Warning beam gate (60 ms) ~80 triggers/day (few tens events expected). Cosmic Rays trigger: PMT-Sum signal coincidence of two adjacent chambers (50% central cathode transparency) ~130 events/h (~160 expected) Preliminary analysis done, needing a more detailed study of the collected data and comparison with MC simulation. Slide# Slide: : 29 29

1.5m drift 1.5m drift Additional trigger on local charge deposition Dedicated algorithm implemented on FPGA on SuperDAEDALUS chip: on-line hit-finding of ionization charge signal from single TPC wires Collection view Collection view Events under threshold for PMT s Short muons traks ~2 MeV isolated electron CR events Used to improve the cosmic ray/cngs trigger efficiency in 0.1 1 GeV range An efficient data reduction system 0-skipping Slide# Slide: : 30 30

max drift 60 ppt O 2 equiv. LAr purification (<60 parts per trillion O 2 equivalent) West Cryostat East Cryostat New pumps LAr continuously filtered! LAr recirculation upgrade: new more efficient non-immersed motor pump installed in East-cryo t ele > 5ms (~60 ppt [O 2 ] eq ), maximum charge attenuation at 1.5 m: 17%. A paper in preparation on successful commissioning and three year underground operation of the cryogenic plant. SPS-C_June.2013 Slide# : 31

Automation of reconstruction CNGS n event primary vertex: automatic reconstruction Validation with visually identified CNGS vertices algorithm efficiency ~ 97% automatic event segmentation algorithm Track identification Shower identification Ready in 2D, to be extended in 3D FIRST STAGE, output from segmentation: clusters and vertices Candidates for shower: high density of vertices Just single hits-> neutron, noise SECOND STAGE, Track clusters, after merging clusters from the segmentation stage: Selected example in green SPS-C_June.2013 Deltas are excluded during the clusters merging. Slide# : 32

ICARUS LAr-TPC detection technique 2D projection for each of 3 wire planes per TPC 3D spatial reconstruction from stereoscopic 2D projections charge measurement from Collection plane signals Collection (top view) Induction 2 (top view) Induction 1 (frontal view) CNGS n m charged current interaction 33

The method Collection view Induction 1 view 3 dimensional reconstruction Two method developed for ICARUS: Variable track segmentation ( classical ) Kalman filter The projection of the track in the Collection plane is split in segments of length l Deflections between segments are calculated The RMS of deflection angles depends on the momentum p and on the measurement error 13.6MeV p l X 0 l noise 3 2 Slide: 34

Signal selection efficiency check in MC simulation automatic cuts mimicking data selection, large sample of MC C1: inside fiducial volume and E dep < 30 GeV; C2: no identified muon, at least one shower; C3: one shower: initial point (or g conversion point) < 1 cm from vtx, separated from other tracks; C4: ionisation signal from single mip in the first 8 wires. Signal selection efficiency (after the fiducial and energy cuts): 0.6/0.81 = 0.74, in agreement with the visual scanning method. 35