JOURNAL OF ENVIRONMENTAL SCIENCES 35 (2015) Available online at ScienceDirect

Similar documents
Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

Aminoglycosides in Milk Using Agilent Bond Elut Plexa SPE, Agilent Poroshell 120, and LC/Tandem MS

Application Note. Gas Chromatography/Mass Spectrometry/Food Safety. Abstract. Authors

Quantification of growth promoters olaquindox and carbadox in animal feedstuff with the Agilent 1260 Infinity Binary LC system with UV detection

Determination of Alkaloids in Goldenseal Using Agilent Bond Elut Plexa Solid Phase Extraction Sorbent for Cleanup and HPLC-DAD Analysis

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

with diode array detection

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Determination of underivatized aflatoxins B2, B1, G2, and G1 in ground hazelnuts by immunoaffinity solid-phase extraction with HPLC-FLD detection

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

It s hot! ZIC -chilic

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

DETERMINATION OF CHLORAMPHENICOL RESIDUES IN HONEY BY MONOLITHIC COLUMN LIQUID CHROMATOGRAPHY MASS SPECTROMETRY AFTER USE OF QUECHERS CLEAN-UP

Comparison of high-speed counter-current chromatography and high-performance liquid chromatography on fingerprinting of Chinese traditional medicine

Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

This method describes the identification of the following prohibited colorants in cosmetic products:

Simultaneous Determination of Paraquat and Diquat in Environmental Water Samples by HPLC-MS/MS

Solid Phase Extraction Method Development Tips and Tricks

[ Care and Use Manual ]

Supporting Information

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Electronic Supplementary Information. The selective response of templated polymer for the cationic drug

Supporting Information. Detection and Occurrence of Chlorinated By-products of Bisphenol A, Nonylphenol and

Automated Switching Between 1D-LC and Comprehensive 2D-LC Analysis

Appendix II- Bioanalytical Method Development and Validation

HPLC Winter Webinars Part 2: Sample Preparation for HPLC

12 Nicarbazin Nicarbazin (4,4 -dinitro carbanilid (DNC) and 2-hydroxy-4,6-dimethyl pyrimidine (HDP))

Volume 6, Issue 2, January February 2011; Article-015

EVOLUTE WCX Columns for Solid Phase Extraction of Quaternary Amines and Strongly Basic Compounds from Aqueous Samples

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Selective Formation of Benzo[c]cinnoline by Photocatalytic Reduction of 2,2 Dinitrobiphenyl with TiO 2 and UV light irradiation

Supporting information Online HPLC-ESI-HRMS Method for the Analysis and Comparison of Different Dissolved Organic Matter Samples

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Mashhour Ghanem 1 and Saleh Abu-Lafi 2 * ABSTRACT ARTICLE INFO

Department of Analytical Chemistry, International Institute of Biotechnology and Toxicology (IIBAT), Padappai, Kancheepuram , India

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

ANALYTICAL METHOD DETERMINATION OF VOLATILE ALDEHYDES IN AMBIENT AIR Page 1 of 11 Air sampling and analysis

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

A rapid and highly selective colorimetric method for direct detection of tryptophan in proteins via DMSO acceleration

Yuhui Yang, An Trinh, Michael Ye, and Tom Henderson 595 North Harrison Road, Bellefonte, PA T HKB

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

IDENTIFICATION OF STEROIDS IN COSMETIC PRODUCTS BY TLC AND HPLC 1 02/12/2005 ACM 007 A. THIN LAYER CHROMATOGRAPHY (TLC)

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

Introduction to Pharmaceutical Chemical Analysis

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Validated RP-HPLC Method for Estimation of Cefprozil in Tablet Dosage Form

TECHNICAL BRODIFACOUM

Preparative Separation of Active Components from Natural Products using Low-pressure Gradient Preparative HPLC

Hydrophilic Interaction Liquid Chromatography: Some Aspects of Solvent and Column Selectivity

Impact factor: 3.958/ICV: 4.10 ISSN:

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

Detection of 9-tetrahydrocannabinol ( 9-THC) in human urine by Solid Phase Extraction and HPLC.

Determination of Pharmaceuticals in Environmental Samples

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

Determination of trace anions in concentrated hydrofluoric acid

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Minimizing Solvent Impact on Purification of Nitrogencontaining

HPLC Praktikum Skript

DETERMINATION OF CHLORPYRIFOS PESTICIDE BY EFFERVESCENCE LIQUID PHASE MICROEXTRACTION HPLC UV-VIS

LC/MS/MS Analysis of Pesticide Residues in Apples Using Agilent Chem Elut Cartridges

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

METHOD 8032A ACRYLAMIDE BY GAS CHROMATOGRAPHY

Application Note. Agilent Application Solution Analysis of acaricides in honey. Authors. Abstract. Food

NOTE. Separation of chlorophenols using columns of hydroxyaluminium interlayered clays

Test method for the determination of NDMA and NDEA by LC-MS/MS in Sartan containing film coated tablets

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

The Effect of Contact Angle and Wetting on Performance in Solid Phase Extraction

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Chemical derivatization

Simultaneous, Fast Analysis of Melamine and Analogues in Pharmaceutical Components Using Q Exactive - Benchtop Orbitrap LC-MS/MS

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

Sensitive Femtogram Determination of Aflatoxins B 1 , B 2 , G 1. and G 2. in Food Matrices using Triple Quadrupole LC/MS. Authors.

Transcription:

Available online at www.sciencedirect.com ScienceDirect www.journals.elsevier.com/journal-of-environmental-sciences Analysis of trace dicyandiamide in stream water using solid phase extraction and liquid chromatography UV spectrometry Huidong Qiu 1,2,, Dongdi Sun 2, Sameera R. Gunatilake 2, Jinyan She 2, Todd E. Mlsna 2, 1. Department of Chemistry and Chemical Engineering, Chongqing University of Science and Technology, Chongqing 401331, China. E-mail: qhd324@163.com 2. Department of Chemistry, Mississippi State University, Mississippi State, MS 39762, USA ARTICLE INFO Article history: Received 14 November 2014 Revised 4 February 2015 Accepted 4 February 2015 Available online 6 June 2015 Keywords: Dicyandiamide Solid phase extraction Stream water samples High performance liquid chromatography ultraviolet spectrometry ABSTRACT An improved method for trace level quantification of dicyandiamide in stream water has been developed. This method includes sample pretreatment using solid phase extraction. The extraction procedure (including loading, washing, and eluting) used a flow rate of 1.0 ml/min, and dicyandiamide was eluted with 20 ml of a methanol/acetonitrile mixture (V/V = 2:3), followed by pre-concentration using nitrogen evaporation and analysis with high performance liquid chromatography ultraviolet spectroscopy (HPLC UV). Sample extraction was carried out using a Waters Sep-Pak AC-2 Cartridge (with activated carbon). Separation was achieved on a ZIC -Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50 mm 2.1 mm, 3.5 μm) chromatography column and quantification was accomplished based on UV absorbance. A reliable linear relationship was obtained for the calibration curve using standard solutions (R 2 > 0.999). Recoveries for dicyandiamide ranged from 84.6% to 96.8%, and the relative standard deviations (RSDs, n = 3) were below 6.1% with a detection limit of 5.0 ng/ml for stream water samples. 2015 The Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V. Introduction Dicyandiamide (DCD) is a chemical compound used broadly as a nitrification inhibitor, which mixes with urease inhibitors and urea to prevent nitrogen loss in the soil and keep nitrogen in the stable ammoniacal form for a longer period of time (Willison and Anderson, 1991; Di and Cameron, 2011; Zhang et al., 2009). It has also been applied for promoting the growth of grass in cow pastures. However, contaminated grass and drinking water may result in the production of milk with trace levels of dicyandiamide residues. Low levels of dicyandiamide residues in 10 out of 100 samples of Fonterra dairy milk products from the North and South Islands of New Zealand in 2012 have been reported (Lucas, 2013). Investigation of the toxicology (Jia et al., 2008) suggested that when DCD was given to mice at the highest dose, after 16 hr the mice began to show restlessness, jumping, and shortness of breath, and later died within a few minutes. According to the dosage and the mortality of mice, the dicyandiamide LD 50 was greater than 5000 mg/kg, and its acute toxicological properties were similar to those of melamine. Therefore, DCD residue in food has become a severe concern in milk and dairy products due to the potential risk to children's health. Dicyandiamide (Fig. 1) is a strong polar amine compound (Stockel, 1969) which can be stable in water streams. The source of drinking water for pasture animals in many New Zealand farms is contaminated with DCD because of its stability in water. Therefore, there is a growing desire to monitor trace dicyandiamide in water streams located near pastureland where DCD has been applied. Corresponding authors. E-mail: mushdq@gmail.com (Todd E. Mlsna). http://dx.doi.org/10.1016/j.jes.2015.02.010 1001-0742/ 2015 The Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences. Published by Elsevier B.V.

39 Fig. 1 Structure of dicyandiamide. A paper chromatographic method (Milks and Janes, 1956) was first developed to detect dicyandiamide in 1956, but the method provides only qualitative analysis. Spectroscopic (Pretorius et al., 1991) and additional chromatographic methods (Zhou et al., 2009; MacMahon et al., 2012; Hiradate et al., 2005; Xu et al., 2013) have been applied for DCD analysis in the food and medical industries. Turowski et al.'s study (Turowski and Deshmukh, 2004) demonstrated detection limits at 100 ng/ml in an aqueous solution, and another method (Chen et al., 2013) obtained a limit of quantification (LOQ) up to 0.5 ng/g DCD in dairy products using high performance liquid chromatography diode array detector (HPLC DAD). A high performance liquid chromatography tandem mass spectrometry (HPLC MS MS) method was developed (Wang et al., 2012) that produced a limit of detection (LOD) of 0.3 ng/ml in food samples. However, most of these methods are expensive (tandem mass spectrometer needed). They have low sensitivity and reproducibility, and require complex sample preparation (pre-column derivatization). Therefore, there is a growing need to develop a fast, simple and cheap method for analyzing trace dicyandiamide in environmental water mixtures. Sample pretreatment is very important when carrying out trace analysis, because an effective sample pretreatment method (Zheng et al., 2008; Liu et al., 2014; Tang et al., 2014; Tran et al., 2013) may increase overall method sensitivity. Oasis MCX mixed-mode cation exchange and reversed-phase sorbent has high selectivity for basic compounds and is suitable for compounds with amine groups. This sorbent has active carbon nanoparticles, which possess high surface activity and result in efficient adsorption and desorption of DCD. DCD contains a cyanide and amine groups, therefore, cation exchange mode extraction cartridges such as proelut PXC and Sep-Pak AC-2 (containing activated carbon) could also be used as part of a detection and quantification method. The goal of this work was essentially pragmatic: to develop a method using simple apparatus that is effective, highly sensitive, cheap and easily implemented in ordinary laboratories for monitoring trace level DCD. 1. Materials and methods 1.1. Reagents, apparatus, equipment and solutions Dicyandiamide (analytical grade) to prepare the required analytical standards, and acetonitrile and methanol (HPLC grade) were purchased from Sigma Aldrich (USA). Ultrapure water was produced by a Milli-Q water purification system (Direct-Q3, Merck Millipore, Wimereux, France). Calibration standard solutions were diluted with ultrapure water to obtain different concentration solutions in the range of 1.0 100.0 mg/l, then 0.2 ml of each solution was diluted to 2.0 ml with acetonitrile to obtain the final corresponding standard solution, respectively. The eluting solution was prepared by mixing two volumes of methanol with three volumes of acetonitrile. Sep-Pak AC-2 solid phase extraction (SPE) cartridges (400 mg, Waters Corporation, Milford, MA, USA) were purchased from Waters. A nitrogen evaporator (N-EVAPIII, Organmation Associates Inc., West berlin, MA, USA) and vortex mixer (Standard mixer, Fisher Scientific, Fair Lawn, NJ, USA) were applied. The HPLC UV system was an Agilent 1200 with UV detector system (HPLC-1200, Agilent Technologies Inc., Santa Clara, CA, USA) and liquid chromatography column ZIC -Hydrophilic Interaction Liquid Chromatography (ZIC-HILIC) (50 mm 2.1 mm, 3.5 μm, Merck & Co. Inc., Darmstadt, Germany). 1.2. Instrumental analysis The analysis of DCD was performed on an Agilent 1200 HPLC system. Separation was achieved with a ZIC-HILIC column (50 mm 2.1 mm, 3.5 μm). The column temperature was kept at 22 C, the mobile phase was an acetonitrile aqueous solution (acetonitrile:water = 90:10), the flow rate was 0.1 ml/min and injection volume was 5 μl. Total run time was 6 min and the UV detection wavelength was set at 219 nm. 1.3. Solid phase extraction and preparation of solution for analysis According to the manufacturer's instructions, Sep-Pak AC-2 cartridges (400 mg) were activated using 10 ml acetonitrile and equilibrated with 10 ml ultrapure water. Water samples (20 100 ml) were then loaded onto the cartridges and adsorbed by activated carbon at a flow rate of 1 ml/min. Subsequently, the cartridge was washed with 10 ml of ultrapure water. Dicyandiamide was eluted immediately with 20 ml of an acetonitrile/methanol mixture (ratio 3:2, V/V) with a flow rate of 1 ml/min. In order to obtain reasonable extraction efficiency, 10 50 ng/ml standard solutions with increments of 10 ng/ml were selected for the experiment, with three replicates for each concentration. Different concentration water samples were loaded onto a Sep-Pak AC-2 cartridge and eluted with separate 1 ml portions of acetonitrile and methanol mixed solution, respectively. After the Sep-Pak AC-2 solid phase extraction, the 20 ml eluant solution was evaporated using a nitrogen stream in a 50 C water bath for 15 min; the residue was then dissolved in 1 ml of a 90% acetonitrile aqueous solution (LC mobile phase solution). Subsequently, the acetonitrile aqueous solution was vigorously shaken using a vortex mixer for 30 sec and filtered by a 0.45 μm filter membrane; the final solution was then ready for the LC-UV analysis. 1.4. Calculation method for recovery Recovery experiments were also carried out to evaluate the extraction efficiency of the method. 20 100 ml of dicyandiamidespiked water samples was extracted using the above-mentioned method. Concentrations of the spiked samples were determined

40 JOURNAL OF ENVIRONMENTAL SCIENCES 35 (2015) 38 42 using a calibration curve. Recoveries were calculated as the following Eq. (1): R ¼ ðx 1 X 2 Þ=X 3 100% ð1þ where, R is the recovery; X 1 istheobservedamountforthespiked sample; X 2 is the observed amount for the unspiked sample; and X 3 is the amount in the spiked sample. 2. Results and discussion 2.1. Selection of chromatographic separation column DCD is an organic amine compound containing two amine groups that are extremely polar. Following the reported literature (MacMahon et al., 2012; Xu et al., 2013), comparative experiments were carried out using a ZIC-HILIC column (50 mm 2.1 mm, 3.5 μm) and an Agilent ZORBAX Extend C18 column (150 mm 4.6 mm, 5 μm). Experimental results showed that with the Extend C18 column, retention was too weak to separate interfering substances, such as urea, from DCD. Although the ZIC-HILIC column required more time to equilibrate than the Extend C18 column, the ZIC-HILIC column had better separation under the method conditions specified. Therefore the ZIC-HILIC column was selected for this method. The mobile phase (acetonitrile:water = 9:1) was optimized at a flow rate of 0.1 ml/min to obtain optimum separation. The chromatograms of dicyandiamide in water samples are shown in Fig. 2. 2.2. Selection of solid phase extraction column The extraction of the dicyandiamide compound from water by SPE is difficult because of its strong polarity. Therefore we studied the SPE for dicyandiamide precisely using various polymeric adsorbent materials. The strong cation exchange mode-sulfonic acid group SPE cartridges, such as Oasis MCX (Mixed-mode Cation Exchange, Waters Corporation, Milford, MA, USA), proelut PXC (Mixed-mode Cation Exchange, Dikma Technologies Inc., Lake Forest,CA,USA), and proelut SPE (Ion Exchange, Dikma Technologies Inc., Lake Forest, CA, USA), and an activated carbon adsorption SPE cartridge (Sep-Pak AC-2, Waters Corporation, Milford, MA, USA) were investigated in the experiment. According to the conditions for using SPE cartridges and the chemical properties of dicyandiamide, the methanol and acetonitrile can be evaporated quickly and the UV cut-off wavelength is suitable for a UV detector, thus, the mixed solution of methanol and acetonitrile was selected to elute the analyte from SPE cartridges. It is well recognized that the solution flow rate may affect the extraction efficiency and an appropriate slow flow rate is suitable for extraction. According to the cartridges' recommended values for flow rate (1.0 2.0 ml/min) and saturated capacity, the experiment selected 20 100 ml water samples, which were then loaded onto the cartridges and eluted with a flow rate of 1.0 ml/min under the natural gravitational discharge. Meanwhile, the eluent volume was optimized in order to ensure complete elution of the analyte. In addition to testing the different cartridges, the effect of varying the ph of the water was studied. DCD is a weakly basic compound; therefore, the water sample should be acidified before SPE because then the analyte is charged and experiences maximum retention, primarily via the ion-exchange mechanism, which is beneficial to be able to capture the basic analyte and then wash out interfering substances aggressively. The optimal ph value of the dicyandiamide solutions for the different cation exchange SPE cartridges was approximately 2.0. However, the effect of varying the ph value when using the activated carbon adsorption SPE cartridge (Sep-Pak AC-2, Waters Corporation, Milford, MA, USA) was extremely small, and the Sep-Pak AC-2 cartridge demonstrated the best extraction efficiency compared to other cartridges without sample ph adjustment. After the extraction, the cartridges were not allowed to dry. They were washed of interfering compounds using 10 ml H 2 O and then immediately eluted with 20 ml of a mixture of methanol and acetonitrile (2:3, V/V). The compounds were eluted into 10 ml glass vials. The solvent mixture was evaporated to dryness using a gentle stream of nitrogen in a water bath at 50 C, then 1.0 ml acetonitrile was used to dissolve the analyte in vials. Absolute recoveries were determined using a calibration curve. The extraction efficiency was calculated using 5 50 ng/ml DCD standard solutions with three replicates. The average extraction efficiency of these cartridges is shown in Fig. 3, and Table 1 shows that the extraction recovery of DCD was 84.6% 96.8%. It should be noted that the operator technique and different cartridge batches also affect the extraction efficiency in water samples, as shown in Fig. 3. 2.3. Matrix effect Fig. 2 Chromatogram of dicyandiamide (DCD) in water sample. (a) No sample pretreatment for DCD aqueous solution of 10 ng/ml; (b) after SPE and concentrated 20 times for DCD aqueous solution from 5 to 100 ng/ml. Peaks at 3.665 and 4.528 min are characteristic of DCD. mau: 10 3 absorbance unit. Matrix effects were determined by preparing a calibration curve in acetonitrile and comparing the response to a curve prepared with post-extraction matrix extracts (Matuszewski et al., 2003). The response at each concentration in a matrix extract was divided by the response of the equivalent concentration in the acetonitrile solvent. The linear regression equations of DCD in solvent and matrix were Y 1 =0.2633C 1 0.8633 (R 1 =0.9999)

41 Fig. 3 Solid phase extraction efficiency. RSD: relative standard deviation; n: the number of replicates; Sep-Pak AC-2, Oasis MCX, proelut SPE, proelut PXC are different types of SPE cartridges. and Y 2 = 0.2421C 2 + 4.9498 (R 2 = 0.9997), respectively. In this study, we used Eq. (2) to calculate the matrix effect. Matrix effect ¼ ðx 4 X 5 Þ=X 4 100% ð2þ where, X 4 and X 5 are slopes of the calibration curves of dicyandiamide in pure solvent and matrix, respectively. A calculated matrix effect with a positive value indicates ion suppression, whereas a negative value indicates ion enhancement. An efficient SPE step may eliminate some of the coeluting substances and result in reduced matrix interferences. The experiment result shows that the matrix effect for the pretreatment matrices was 8.1% (<12%). Research workers have emphasized that matrix effects are not significant if the matrix effect value is less than 12% for trace organic compounds in environmental water (Moreno-Bondi et al., 2009). Since the extraction method used for this study reduced matrix effects, the preparation of a matrix-matched calibration curve was not necessary. Linear regression for the two calibration curves was 0.999. In addition, the experiment achieved acceptable recoveries (84.6% 96.8%) using pure solvent calibration curves. 2.4. Detection limits and linear range This method has enrichment and concentration factors of 100 fold, where the water sample pretreatment procedure should be considered. The method limit of detection (LOD) and limit of quantitation (LOQ) were determined with a blank postextraction matrix with known standard concentrations, measuring the concentrations where the signal to noise ratios of quantitative transition for dicyandiamide were greater than 3:1 (LOD) and 10:1 (LOQ). Subsequently the LOD and LOQ of the method were calculated using seven replicates to obtain a standard deviation. In the present study, a method LOD 1.5 ng/ml and LOQ 5.0 ng/ml were successfully achieved in the matrix water samples. In addition, the linearity of the present method was established using different working concentrations of dicyandiamide. Results showed that this method has a good linear range of 5.0 1000 ng/ml with R 2 of 0.9997. 2.5. Recovery and dicyandiamide concentration of water samples In this study, experimental water samples were collected from New Zealand pasture streams in the southland province of New Zealand. Three different classes of water samples were selected including New Zealand stream water, simulated water samples with matrix chemicals, and New Zealand blank water samples. The recoveries, which ranged from 84.6% to 96.8%, are summarized in Table 1. Relative standard deviations were less than 6.1%. Higher than 100% recovery is the result of enrichment or operation factors, whereas low R would occur if a fraction of the analyte is lost during extraction. The method is considered to be reliable for quantification of DCD in stream waters, and it has relatively low relative standard deviations based on three replicate analyses. 3. Conclusions The method was optimized to ensure fast and sensitive determination of trace dicyandiamide by combining solid phase extraction with HPLC-UV. The solid phase extraction method significantly reduced about 70% of the matrix interference. A low limit of quantification of 5 ng/ml was achieved using a relatively small sample volume of 20 100 ml. The experimental results suggested that the method is reliable and consistent, as the method produced acceptable recoveries in the range of 84.6% 96.8% with 1.8% 6.1% RSDs. Table 1 Results of water samples and recovery experiment. Sample describe Amount of unspiked sample Spiked amount Enrichment factor Amount of spiked sample Recovery Relative standard deviations Mixed water 1# from New Zealand stream Mixed water 2# from New Zealand stream Simulated water of matrix from New Zealand blank water 13.5 10.0 20 450 95.7% 6.1% 13.5 10.0 20 399 84.6% 13.5 10.0 20 426 90.6% 50.5 50.0 10 986 96.2% 1.8% 50.5 50.0 10 962 91.4% 50.5 50.0 10 953 89.6% 0.0 50.0 20 942 94.2% 3.7% 0.0 20.0 50 916 91.6% 0.0 10.0 100 968 96.8%

42 JOURNAL OF ENVIRONMENTAL SCIENCES 35 (2015) 38 42 Acknowledgments The authors would like to acknowledge the Department of Chemistry at Mississippi State University for financial support for this project and Dr. Christoph Matthaei's research group from the Department of Zoology at the University of Otago for water sample supply. REFERENCES Χηεν, X.Z., Chen, W.Q., Wang, J., Huang, L.Y., Zhang, D.L., 2013. Determination of dicyandiamide in dairy products by high performance liquid chromatography. Chin. J. Chromatogr. 31 (9), 875 877. Di, H.J., Cameron, K.C., 2011. Inhibition of ammonium oxidation by a liquid formulation of 3,4-dimethylpyrazole phosphate (DMPP) compared with a dicyandiamide (DCD) solution in six new Zealand grazed grassland soils. J. Soils Sediments 11 (6), 1032 1039. Hiradate, S., Kamo, T., Nakajima, E., Kato, K., Fujii, Y., 2005. Direct quantitative determination of cyanamide by stable isotope dilution gas chromatography mass spectrometry. J. Chromatogr. A 1098 (1-2), 138 143. Jia, G.L., Wang, J.F., Lin, X.M., Mei, L., 2008. A comparative study of four kinds of toxic melamine. China Anim. Husb. Veterin. Med. 35 (12), 162 163. Liu, X.D., Yu, Y.J., Zhao, M.Y., Zhang, H.Y., Li, Y., Duan, G.L., 2014. Solid phase extraction using magnetic core mesoporous shell microspheres with C18-modified interior pore-walls for residue analysis of cephalosporins in milk by LC MS/MS. Food Chem. 150, 206 212. Lucas, G.N., 2013. Dicyandiamide contamination of milk powders. Sri Lanka J. Child Health 42 (2), 63 64. MacMahon, S., Begley, T.H., Diachenko, G.W., Stromgren, S.A., 2012. A liquid chromatography tandem mass spectrometry method for the detection of economically motivated adulteration in protein-containing foods. J. Chromatogr. A 1220, 101 107. Matuszewski, B.K., Constanzer, M.L., Chavez-Eng, C.M., 2003. Strategies for the assessment of matrix effect in quantitative bioanalytical methods based on HPLC MS/MS. Anal. Chem. 75 (13), 3019 3030. Milks, J.E., Janes, R.H., 1956. Separation and detection of cyanamide and its derivatives and determination of urea by paper chromatography. Anal. Chem. 25 (5), 846 849. Moreno-Bondi, M.C., Marazuela, M.D., Herranz, S., Rodriguez, E., 2009. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples. Anal. Bioanal. Chem. 395 (4), 921 946. Pretorius, D.C., Vanstaden, J.F., Botha, A.D.P., 1991. An automated colorimetric method for the determination of cyanoguanidine in water. Water SA 17 (4), 273 280. Stockel, R.F., 1969. Dicyandiamide (cyanoguanidine). J. Chem. Educ. 46 (6), 391. Tang, K.J., Gu, X.H., Luo, Q.S., Chen, S.W., Wu, L.Y., Xiong, J.H., 2014. Preparation of molecularly imprinted polymer for use as SPE adsorbent for the simultaneous determination of five sulphonylurea herbicides by HPLC. Food Chem. 150 (2), 106 112. Tran, K., Mactal, L.P., Cromer, M.R., Vocque, R.H., Smith, R.E., 2013. Development and validation of ethylenethiourea determination in foods using methanol-based extraction, solid-phase extraction cleanup and LC-MS/MS. Food Chem. 140 (1-2), 340 342. Turowski, M., Deshmukh, B., 2004. Direct chromatographic method for determination of hydrogen cyanamide and dicyandiamide in aqueous solutions. Anal. Lett. 37 (9), 1981 1989. Wang, Z.X., Jiang, J., Sun, L., Zhou, H.B., Zhao, Y.X., 2012. Determination of urea, biuret and dicyandiamide in foods by high performance liquid chromatography tandem mass spectrometry. J. Instrum. Anal. 31 (5), 593 599. Willison, T.W., Anderson, J.M., 1991. Dicyandiamide as an inhibitor of denitrification in coniferous forest soils. Soil Biol. Biochem. 23 (7), 605 607. Xu, J.J., Zhang, J.X., Huang, B.F., Ren, Y.P., 2013. Isotope dilution determination of dicyandiamide in milk powder by liquid chromatography tandem mass spectrometry. J. Food Saf. Qual. 4 (2), 415 420. Zhang, L.L., Wu, Z.J., Chen, L.J., Zhang, H.J., Zhang, Y.L., Chen, Z.H., 2009. Effect of coating and dicyandiamide incorporation on NH + 4 nitrification and NO 3 leaching. J. Ecol. Environ. Sci. 18 (4), 1508 1515. Zheng, M.M., Zhang, M.Y., Peng, G.Y., Feng, Y.Q., 2008. Monitoring of sulfonamide antibacterial residues in milk and egg by polymer monolith microextraction coupled to hydrophilic interaction chromatography/mass spectrometry. Anal. Chim. Acta 625 (2), 160 172. Zhou, C.M., Zhou, J.P., Wu, J., Li, X.J., 2009. HPLC method for determination of dicyandiamide in workplace air. Jiangsu J. Prev. Med. 20 (3), 63 64.