Testing and data reduction of the Chinese Small Telescope Array (CSTAR) for Dome A,

Similar documents
arxiv: v1 [astro-ph.im] 27 Jan 2010

arxiv: v1 [astro-ph.im] 31 Jul 2014

arxiv: v1 [astro-ph.im] 31 Jul 2014

Progress and Results from the Chinese Small Telescope ARray (CSTAR)

arxiv: v1 [astro-ph.ga] 27 Jan 2010

Optical system of the Three Antarctic Survey Telescopes

Optical system of the Three Antarctic Survey Telescopes

The First Release of the CSTAR Point Source Catalog from Dome A, Antarctica

The Telescopes and Activities on Exoplanet Detection in China. ZHOU Xu National Astronomical Observatories

Upgraded Photometric System of The 85-cm Telescope at Xinglong Station

Investigating the Efficiency of the Beijing Faint Object Spectrograph and Camera (BFOSC) of the Xinglong 2.16-m Reflector

Sky brightness from Dome A

Study of Physical Characteristics of High Apogee Space Debris

Mass Astronomical Data at Dome A and VO

Chin. J. Astron. Astrophys. Vol. 2 (2002), No. 5, 474{480 Chinese Journal of Astronomy and Astrophysics Ghost Images in Schmidt CCD Photometry Bin Yan

The Kunlun Infrared Sky Survey (KISS) with AST3-NIR Camera. Jessica Zheng

arxiv:astro-ph/ v1 26 Nov 2004

DOME C AS A SETTING FOR THE PERMANENT ALL SKY SURVEY (PASS)

A Calibration Method for Wide Field Multicolor. Photometric System 1

Modeling the CCD Undersampling Effect in the BATC Photometric System

Thirteen-Color Photometry of Open Cluster M48

Present and future Chinese large telescope projects

The Large Sky Area Multi-Object Fiber Spectroscopic Telescope (LAMOST)

The Optical Microvariability and Spectral Changes of the BL Lacertae Object S

arxiv: v1 [astro-ph.im] 24 Mar 2009

arxiv: v2 [astro-ph.sr] 16 May 2013

Large FOV Mobile E-O Telescope for Searching and Tracking Low-earth Orbit Micro-satellites and Space Debris

Astronomy in Antarctica

ASTROPHYSICS FROM DOME A

V551 Aur, an oea binary with g-mode pulsations?

VRI Photometry of M67 for CCD Standardization at 2.3m VBT

Atmospheric monitoring strategy for the Ali site, Tibet

1 A photometric probe for Pan-STARRS

You, too, can make useful and beautiful astronomical images at Mees: Lesson 3

NEWFIRM Quick Guide for Proposal Preparation

Observation of Light Curves of Space Objects. Hirohisa Kurosaki Japan Aerospace Exploration Agency Toshifumi Yanagisawa.

Alignment metrology for the Antarctica Kunlun Dark Universe Survey Telescope

Problem Solving. radians. 180 radians Stars & Elementary Astrophysics: Introduction Press F1 for Help 41. f s. picture. equation.

Discovery of a deep, low mass ratio overcontact binary GSC

Variable stars in the field of open cluster NGC 2126

Mid-Infrared Astronomy with IRAIT at Dome C: performances and simulations

1 The Preliminary Processing

Future Robotic observatory on Mountain Vidojevica: site and equipment specification

Photometric Techniques II Data analysis, errors, completeness

AST 101 Intro to Astronomy: Stars & Galaxies

Millimagnitude Accuracy Photometry of Extra solar Planets Transits using Small Telescopes

A very bright (i = 16.44) quasar in the redshift desert discovered by the Guoshoujing Telescope (LAMOST)

PLATO operation and Dome A site properties. Michael Ashley / University of New South Wales

AS750 Observational Astronomy

Atmospheric extinction coefficients and night sky brightness at the Xuyi Observation Station

OPTICAL PHOTOMETRY. Observational Astronomy (2011) 1

PHOTOMETRIC QUALITY OF DOME C FOR THE WINTER 2008 FROM ASTEP SOUTH

Introduction to the Chinese Giant Solar Telescope

Chapter 6 Lecture. The Cosmic Perspective Seventh Edition. Telescopes Portals of Discovery Pearson Education, Inc.

Igor Soszyński. Warsaw University Astronomical Observatory

arxiv: v2 [astro-ph.sr] 9 Nov 2015

Astronomy 203 practice final examination

Notes: Reference: Merline, W. J. and S. B. Howell (1995). "A Realistic Model for Point-sources Imaged on Array Detectors: The Model and Initial

Transiting Exoplanet in the Near Infra-red for the XO-3 System

AUTOMATED SITE TESTING FROM ANTARCTICA

Astronomical Experiments for the Chang E-2 Project

Reduction procedure of long-slit optical spectra. Astrophysical observatory of Asiago

Discovery of a deep, low mass ratio overcontact binary GSC

An experimental indoor phasing system based on active optics using dispersed Hartmann sensing technology in the visible waveband

Spitzer Space Telescope

Introduction of Chinese Antarctic Optical Telescopes

Photometric Observations of the δ Scuti Star UV Trianguli and its Evolutionary Status

Real Telescopes & Cameras. Stephen Eikenberry 05 October 2017

PoS(ICRC2015)641. Cloud Monitoring using Nitrogen Laser for LHAASO Experiment. Z.D. Sun 1,Y. Zhang 2,F.R. Zhu 1 for the LHAASO Collaboration

The Correction of Atmospheric Dispersion in LAMOST*

New Northern Hemisphere Variables

arxiv: v1 [astro-ph.im] 20 Nov 2012

1. Give short answers to the following questions. a. What limits the size of a corrected field of view in AO?

2-D Images in Astronomy

arxiv: v1 [astro-ph.im] 31 Jul 2014

Chapter 6 Lecture. The Cosmic Perspective. Telescopes Portals of Discovery Pearson Education, Inc.

Lecture 8. October 25, 2017 Lab 5

PILOT - THE PATHFINDER FOR AN INTERNATIONAL LARGE OPTICAL TELESCOPE

Antarctic astronomy. John Storey. Image: Xuefei Gong

LAMOST Sky Survey --Site limitations and survey planning

Modern Observational/Instrumentation Techniques Astronomy 500

New Observation Results from A Rotating-drift-scan CCD System

Why Use a Telescope?

Data Processing in DES

Refraction is the bending of light when it passes from one substance into another. Your eye uses refraction to focus light.

Photometric Studies of GEO Debris

Detection of Artificial Satellites in Images Acquired in Track Rate Mode.

Snodar: 2009 performance at Dome A, Antarctica

Lab 4 Radial Velocity Determination of Membership in Open Clusters

Hanle Echelle Spectrograph (HESP)

ASTR 1120 General Astronomy: Stars & Galaxies

Simulations for H.E.S.S.

Introduction to SDSS -instruments, survey strategy, etc

Development of Laser Measurement to Space Debris at Shanghai SLR Station

On to Telescopes. Imaging with our Eyes. Telescopes and cameras work much like our eyes. ASTR 1120 General Astronomy: Stars & Galaxies !

Chapter 5. Telescopes. Copyright (c) The McGraw-Hill Companies, Inc. Permission required for reproduction or display.

Micro-fluctuations of Fried s parameter (r 0 )

Optics and Telescopes

Chapter 6: Transforming your data

The Large Synoptic Survey Telescope

Transcription:

Home Search Collections Journals About Contact us My IOPscience Testing and data reduction of the Chinese Small Telescope Array (CSTAR) for Dome A, Antarctica This article has been downloaded from IOPscience. Please scroll down to see the full text article. 2010 Res. Astron. Astrophys. 10 279 (http://iopscience.iop.org/1674-4527/10/3/009) View the table of contents for this issue, or go to the journal homepage for more Download details: IP Address: 129.94.162.194 The article was downloaded on 12/09/2012 at 04:24 Please note that terms and conditions apply.

Research in Astron. Astrophys. 2010 Vol. 10 No. 3, 279 290 http://www.raa-journal.org http://www.iop.org/journals/raa Research in Astronomy and Astrophysics Testing and data reduction of the Chinese Small Telescope Array (CSTAR) for Dome A, Antarctica Xu Zhou 1,4, Zhen-Yu Wu 1, Zhao-Ji Jiang 1,4, Xiang-Qun Cui 2,4, Long-Long Feng 3,4, Xue-Fei Gong 2,4, Jing-Yao Hu 1,4, Qi-Sheng Li 1, Gen-Rong Liu 2, Jun Ma 1, Jia-Li Wang 1,4, Li-Fan Wang 3,4, Jiang-Hua Wu 1, Li-Rong Xia 2, Jun Yan 1,4, Xiang-Yan Yuan 2,4, Feng-Xiang Zhai 2, Ru Zhang 2 and Zhen-Xi Zhu 3,4 1 National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100012, China; zhouxu@bao.ac.cn 2 Nanjing Institute of Astronomical Optics & Technology, National Astronomical Observatories, Chinese Academy of Sciences, Nanjing 210042, China 3 Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008, China; 4 Chinese Center for Antarctic Astronomy, Purple Mountain Observatory, Chinese Academy of Sciences, Nanjing 210008, China Received 2010 January 8; accepted 2010 January 21 Abstract The Chinese Small Telescope Array (CSTAR) is the first Chinese astronomical instrument on the Antarctic ice cap. The low temperature and low pressure testing of the data acquisition system was carried out in a laboratory refrigerator and on the 4500 m Pamirs high plateau, respectively. The results from the final four nights of test observations demonstrated that CSTAR was ready for operation at Dome A, Antarctica. In this paper, we present a description of CSTAR and the performance derived from the test observations. Key words: instrumentation: detectors techniques: photometric stars: variables 1 INTRODUCTION Site testing at the South Pole (90 E, 2835 m elevation) and Dome C (123 E, 75 S, 3260 m elevation) over the past decade has shown that the Antarctic plateau offers outstanding sites for astronomical observations. The extremely cold temperatures lead to very low infrared backgrounds and atmospheric water vapor content. The very low wind speeds and stable middle and upper atmosphere result in favorable seeing conditions for high-resolution imaging (Storey et al. 2007). The median free-atmosphere seeing in Dome C is 0.27 arcsec, and it is below 0.15 arcsec for 25 percent of the time (Lawrence et al. 2004). In addition, the long dark winter on the Antarctic plateau allows continuous observations of variable astronomical objects. Dome A (77 21 E, 80 22 S, 4093 m elevation), the highest point on the Antarctic plateau, is widely predicted to be an even better astronomical site than Dome C, based on the topographic similarity and Dome A s higher altitude. In January 2005, via overland traverse, Dome A was first Supported by the National Natural Science Foundation of China.

280 X. Zhou et al. Table 1 Passband Parameters of Filters Used by CSTAR Telescope CSTAR #2 CSTAR #4 CSTAR #1 CSTAR #3 Filter g r i none Effective Wavelength (nm) 470 630 780 FWHM (nm) 140 140 160 visited by the Polar Research Institute of China (PRIC). This provides astronomers with a good opportunity to explore this special area for astronomy. PRIC plans to establish a permanently manned station at Dome A within the next decade, with astronomy as one of the scientific goals of the station. As part of this program, PRIC conducted a second expedition to Dome A, arriving via overland traverse in January 2008. On this expedition, the first Chinese Antarctic astronomical instrument, CSTAR, was deployed to Dome A. Besides the task of astronomical site testing, the main scientific goals of CSTAR include variable star light curves and statistics, supernovae studies, gamma-ray burst optical afterglow detection and exoplanet detection. CSTAR was designed and constructed during 2006 2007 at the National Astronomical Observatories of China (NAOC) and the Nanjing Institute of Astronomical Optics Technology of China (NIAOT). A series of tests were performed on CSTAR before the second expedition to Dome A to ensure that it was ready for deployment. As a result of this careful preparation, CSTAR operated successfully during 2008, as part of the Plateau Observatory (PLATO) at Dome A (Yang et al. 2009). In Section 2, we describe the design and construction of CSTAR. Test observations at the Xinglong station of NAOC and the data reduction are presented in Section 3. Finally, a summary is given in Section 4. 2 INSTRUMENTS CSTAR is a small 2 2 Schmidt-Cassegrain telescope array. Each telescope of CSTAR has an entrance pupil diameter of 145 mm (effective aperture of 100 mm) and a focal ratio of f/1.2, giving a field of view of 4.5 4.5. Figure 1 shows the optical design of the CSTAR telescope, which consists of a catadioptric objective with a spherical primary mirror, delivering low chromatic aberration. The first plano lens serves both as a window and as a filter. In order to keep the focus unchanged through a 100 C temperature range (from +20 to 80 C ), Zerodur and fused silica are used for the main optical components and Invar 36 is used for the telescope tube. The tube is designed to be light weight, well sealed, and easy to assemble. The inside of the telescope tube was filled by pure nitrogen to avoid ice and frost formation on the internal optical surfaces. Each telescope tube is hermetically sealed and an ITO (Indium-Tin-Oxide) film was coated onto the front window. An electric current is passed through this film, providing 10 W of power to keep the surface of the window warmer than the ambient temperature. CSTAR is specifically designed for Antarctic operation, having no moving parts at all including the optics and mechanical supporting system. The four telescopes are installed in a steel enclosure, see Figure 2, and are pointed at the South Celestial Pole; i.e., each telescope is inclined 9 38 from the zenith. Details of the CSTAR telescope structure are described in Yuan et al. (2008). The three telescopes, CSTAR #2, #4, and #1, havefixed filters: g, r, and i, and the fourth telescope CSTAR #3 is filter-less. The main parameters of the three filters are listed in Table 1 and the transmission curves of those filters are presented in Figure 3. The filters are designed to be similar to the corresponding filters of the SDSS (Fukugita et al. 1996). Using these filters, CSTAR can obtain multicolor photometric data for each object simultaneously. An Andor DV435 1k 1k frame transfer CCD with a pixel size of 13 µm is used for the detector. Frame transfer technology is ideal for fast imaging as it has the advantage of requiring no mechanical shutter. Avoiding the need for moving parts is very desirable on the Antarctic plateau. The CCD was

CSTAR: Testing and Data Reduction 281 Fig. 1 Optical design of the CSTAR telescope. Fig. 2 Picture of the CSTAR enclosure was taken in the XingLong station of NAOC. Fig. 3 Transmission profiles of the 3 CSTAR filters. The filter codes (see Table 1) are labeled on each filter. Note that CSTAR #3 has no filter. enclosed in a control box, as shown in Figure 4. The cable at the back of the box connects to the PCI controller card installed in the control computer. The typical readout noise of the CCD is 3 e with a maximum of 12 e, and the gain is set to 2.0 e per A/D. The peak quantum efficiency of the Andor CCD at 90 C is 95%. During the typical exposure time of 30 s and under the typical ambient temperatures of less than 50 C on the Antarctic plateau, the dark current of the Andor CCD is only 0.5 e. The dark current can thus be negligible under Antarctic conditions.

282 X. Zhou et al. Fig. 4 Andor CCD enclosed in its control box. This picture was taken at Kalasu in the Tajik Autonomous County of Taxkorgan, Xinjiang Pamirs of China. Fig. 5 Computer control equipment. Each Andor CCD is controlled through the CCI-010 PCI controller card installed in an industrial control computer for each telescope. The control computer is composed of a 1TX-i7415VL main board, Intel Centrino 1.6 GHz CPU, and 1 GB of memory. Two kinds of storage disks are used for the control computer. One is a 4 GB CompactFlash (CF) disk which can operate at low temperatures (down to nearly 45 C ); the other is a normal 750 GB IDE hard disk. Figure 5 shows the four control computers. Each computer weighs 8.3 kg. The Windows operating system is installed onto the CF disk because of its greater reliability under low temperature conditions, while the 750 GB hard

CSTAR: Testing and Data Reduction 283 disk is mainly used for data storage. The CCD control and data collection software were developed based on the Andor-SDK-CCD software development kit for the Windows-XP operating system. The time of the control computer of CSTAR #3 is synchronized by GPS and the other computers correct their clock by CSTAR #3. The real time data reduction process starts automatically after the control computer boots. The image is corrected for bias and flat-field frames, and the catalog of objects is produced. The brightest 3000 stars of the catalog from 1/3 of the images are moved to a special directory for data transfer via iridium satellite communication. 3 TESTING AND DATA REDUCTION 3.1 Testing In order to assure the performance of CSTAR under the extremely low temperature conditions of Dome A, the CCD system and several different industrial control computers were tested. Finally, the whole CSTAR system was tested at low temperature in the laboratory of NAOC. These tests indicated that the four telescopes and the CCD can work at low temperatures down to nearly 80 C, while the four control computers can work down to 30 C. In 2007 February 6 9, the CCD and control computers were tested at Kalasu. Kalasu (see Fig. 4) is located in the Tajik Autonomous County of Taxkorgan, on the Xinjiang Pamirs of China at an elevation of 4450 m. We chose Kalasu as the test site because of its low temperature and low atmospheric pressure conditions similar to the Antarctic plateau. The atmospheric pressure was 58.6 kpa and the temperatures ranged from 5 C to 18 C during the testing process. Both the CCD and the control computers were shown to work normally during the two days of testing, and there were four 750GB normal hard disks which were selected for the data storage of CSTAR. On 2007 September 3 7, test observations of CSTAR were performed at the Xinglong station of NAOC. The four CCDs were cooled down to 40 C 50 C by the electronic cooling system Fig. 6 Bias frame images for each telescope.

284 X. Zhou et al. Fig. 7 Flat-field images for each telescope. of the camera. The weather was good most of the time during the four observation nights, and more than 20 000 images were obtained. The typical exposure time was 20 s. Figure 6 shows the super bias images for each telescope, which are the median of 100 bias frame images for each telescope. There is no obvious variation or structure in the super bias images. These super bias images are unique bias frames to be used for reduction of data both from observations at Xinglong and also from Dome A. Variations of night-sky background are obvious even in the zenith direction. If one takes the time during a photometric, moonless night to obtain a long series of sky-dominated images pointing directly at the zenith, the effects of the nonuniformity of the night sky can be minimized. However, our telescope observes the polar sky area at an airmass of 1.54 at the Xinglong station. The median sky background can only be used as an initial flat-field for image correction. Thus, we typically obtained supersky flat-fields by combining images of the sky (Zhou et al. 2004). During this combination, the bright stars in the images were masked and rejected, and only the areas free from stars were used. By comparing the images, the median level of each pixel could be selected to derive the final supersky flat-field. One hundred images of supersky for each telescope of CSTAR were used to obtain the supersky flat-field. These flat-fields mostly reflect the small, pixel to pixel variations in the images. Figure 7 shows the final supersky flat-field images for each telescope. Some obvious structures can still be seen. 3.2 Data Reduction First, for each filter a super bias frame was subtracted from each image, then the supersky flat-field was divided by the bias-corrected images. The bias and flat-field corrected data of 20 000 images obtained by CSTAR during the four test-observation nights were processed with the automatic data reduction software developed by Z. J. Jiang and X. Zhou based on the DAOPHOT photometric package (Stetson 1987), which was used in the data reduction of BATC

CSTAR: Testing and Data Reduction 285 (Fan et al. 1996; Wu et al. 2007). Because CSTAR has a large field and is undersampled, obtaining an accurate point-spread function (PSF) for the sources detected across the whole view of field is very difficult. The DAOFIND program was used to find stars in each image and DAOPHOT was used to perform synthetic aperture photometry on the objects detected by DAOFIND. All instrumental magnitudes of the four telescopes were then normalized to the V band magnitudes of stars in the image 39530013.fit, which was observed by the #3 telescope on 2007 September 5. 3.3 Error Analysis and Correction There are obvious systematic errors in the derived aperture-photometry magnitudes. The errors mainly come from the following sources: 1. The bias stability of each CCD. Due to the continuous observation during exposures and the frame transfer mode of the CCD, there is no opportunity to obtain real-time bias frames. The bias frames obtained at one time must be used for observations from another day at Dome A. Because of variations in the environmental parameters, such as temperature and instrumental status, the bias of each CCD camera may change. This variable bias will introduce linear errors in the observed magnitudes. 2. Non-uniformity of the supersky flat-field. The flat-field images were not obtained during ideal photometric nights, and not from the zenith sky. A brightness gradient and asymmetry may exist in the flat-field frames. The variation in temperature from 40 to 80 C may also change the characteristics of the flat field. During the polar observations by the fixed CSTAR telescopes, every star will trace out a circle on the CCD, and the residual flat-field error will give a false variation in the observed magnitude of each star. 3. Variable PSF for stars in different positions in the images of CSTAR. The telescopes of CSTAR have a large field of view. The optical design cannot keep the PSF exactly uniform over all parts of the image. When we use a fixed aperture to measure the magnitudes of the stars, the PSF depends on the location on the image and this will cause a variation in the instrumental magnitudes of each star relative to the other stars. Because we are observing a single area of the sky, and the sky s image is rotating on the CCD, we have the opportunity to correct the main residual system errors mentioned above. Using thousands of stars with very different magnitudes, we can easily determine the variable component of the bias residuals based on the different magnitudes of those stars in two different images. Using all of the circular traces of the stars, the large-scale residual flat-field correction can be obtained. Using the instrumental magnitudes from several different apertures for each star, the aperture photometry curve-of-growth can be obtained in all parts of the image, but is mainly corrected with residual flatfield correction mentioned above. The instrumental magnitudes obtained from different apertures were calibrated to the standard system. After all these corrections, the systematic errors in the derived photometric magnitudes can be reduced to the level of 0.01 mag for the brightest stars in most of the images. Some sudden abnormal variations, where they exist, mostly come from the cirrus clouds in the sky. Figure 8 presents the magnitude-corrected flat-field images for each telescope using thousands of stars, and shows the obvious circular structures that match the traces of stars on the CCD. Two kinds of error estimates have been performed. One is theoretic statistical estimation based on a star s magnitude and its sky background. The other is obtained by real repeated observations of all the objects in the images. By comparing the errors resulting from different images of the same field with the same filter, we find that the measurement errors are normally ±0.01 mag for bright stars. The statistical errors can be regarded as the lower limits of the measurement errors. In the error estimates, we ignore points with abnormally large deviations to calculate the root mean square

286 X. Zhou et al. Fig. 8 Images of the corrected flat field for each telescope. Fig. 9 Photometric errors for each telescope of CSTAR. The vertical scale is in magnitudes.

CSTAR: Testing and Data Reduction 287 Fig. 10 Image 39530013.fit obtained by CSTAR. The variable stars detected by CSTAR are labeled by green circles in the image. Fig. 11 Light curve of one of the bright sources from the CSTAR telescopes. (rms) errors. The abnormal variation may come from the true star brightness variation, or defects of the image (cosmic ray, satellites, bad pixels, etc). Figure 9 shows the photometric errors for each telescope of CSTAR at different magnitudes. Because the errors estimated by this method include real statistical errors and residual system errors from the bias and flat-field correction, the errors shown in Figure 9 should be larger than the actual observational errors. Figure 9 also shows that the efficiency of telescope #2 of CSTAR is very low and that the limiting magnitude of this telescope is about 2 mag lower than that of the other three telescopes. We knew that the CCD camera for CSTAR #2 was much noisier than the others, but we were unable to change it in the time available.

288 X. Zhou et al. Fig. 12 Light curves of variable stars detected by CSTAR during the test observations at the Xinglong station of NAOC.

CSTAR: Testing and Data Reduction 289 Fig. 12 Continued. Figure 10 shows the image 39530013.fit obtained by CSTAR during the test observations at the Xinglong station of NAOC. As an example of the data obtained, the light curve of one of the bright stars from the four CSTAR telescopes is shown in Figure 11. The main scientific objectives of CSTAR are to assess the site quality of Dome A and to study the variable objects in the region of the South Pole. The variable stars detected by CSTAR are labeled by green circles. The light curves of those variable stars are presented in Figure 12. 4 CONCLUSIONS CSTAR, China s first Antarctic astronomical instrument is described. CSTAR is composed of four small Schmidt-Cassegrain telescopes. Each telescope has an effective aperture of 100 mm and a field of view of 4.5 4.5. Three of the four telescopes are equipped with g, r, i filters, and the fourth one is filter-less. A frame-transfer Andor DV435 1k 1k CCD is used as the detector on each telescope. A specially designed control computer for each telescope is used for data acquisition and data reduction. Low-temperature laboratory testing demonstrates that the telescopes and the CCD can work under extremely low temperatures (down to nearly 80 C ), while the control computer can work at temperatures as low as 30 C. Actual test observations at Kalasu in the Xinjiang Pamirs indicated that the CCD and control computer can work at these low temperatures and under low atmospheric pressure conditions.

290 X. Zhou et al. Super bias and supersky flat-field images were obtained during the test observations at the Xinglong station of NAOC. These test observations and the subsequent data reduction indicate that CSTAR can work stably and obtain a large volume of scientific data. A special data reduction method was used to derive the observational errors for each of the objects detected by CSTAR. The data reduction process is done automatically in real time, and a catalog of the brightest star from 1/3 of the images obtained are prepared for further data transfer via iridium satellite communication. Finally, eight variable stars were detected by CSTAR during the test observations. Acknowledgements This work was supported by the National Natural Science Foundation of China (Grant Nos. 10873016, 10633020, 10603006 and 10803007), and by National Basic Research Program of China (973 Program, No. 2007CB815403). We thank our colleagues at the University of New South Wales, Australia, for assistance in editing this paper. References Fan, X. H., et al. 1996, AJ, 112, 628 Fukugita, M., et al. 1996, AJ, 111, 1748 Lawrence, J. S. Ashley, M. C., Tokovinin, A., & Travouillon, T. 2004, Nature, 431, 278 Stetson, P. B. 1987, PASP, 99, 191 Storey, J. W. V., Lawrence, J. S., & Ashley, C. B. 2007, Revista Mexicana de Astronomia y Astrofisica Conference Series, 31, 25 Wu, Z. Y., et al. 2007, AJ, 133, 2061 Yang, H. G., et al. 2009, PASP, 121, 174 Yuan, X. Y., et al. 2008, SPIE, 7012, 152 Zhou, X., et al. 2004, AJ, 127, 3642