ZirChrom Columns and the Metalox 200-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived.

Similar documents
High Temperature Ultra Fast Liquid Chromatography. Peter W. Carr, Jon Thompson, Dwight Stoll, and Adam Schallinger

High Speed 2D-HPLC Through the Use of Ultra-Fast High Temperature HPLC as the Second Dimension

An Overview of the the Development of Stationary Phases for Reversed-Phase Liquid Chromatography

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Liquid Chromatography

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector

LC Technical Information

Isomer Separation on ZirChrom -CARB

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

ZirChrom Newsletter Vol. #10 Sachtopore-NP and Sachtopore-RP, titania-based HPLC phases

Introduction to Chromatographic Separations

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Quality control analytical methods- Switch from HPLC to UPLC

Chromatography. Gas Chromatography

Chapter content. Reference

Basic Principles for Purification Using Supercritical Fluid Chromatography

Assay Transfer from HPLC to UPLC for Higher Analysis Throughput

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Easy Method Transfer from HPLC to RSLC with the Dionex Method Speed-Up Calculator

HPLC Background Chem 250 F 2008 Page 1 of 24

Analytical Chemistry

Retention and Selectivity Variables

Cation Exchange HPLC Columns

How to Troubleshoot a Failed System Suitability Test

Introduction to Chromatography

Improving HPLC Column Selection and System Performance

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Introduction to Chromatographic Separations (Chapter 1) Many determinations involve separation followed by analysis chromatography electrophoresis

Theory and Instrumentation of GC. Chromatographic Parameters

Application Note. Authors. Abstract. Energy & Chemicals, Biofuels & Alternative Energy

LC and LC/MS Column Selection Flow Chart

Gas Chromatography. Introduction

FAQ's. 1 - Which column would be the most appropriate for my application?

A C18 Silica Column With Exceptional Temperature and ph Stability

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Lab 3 Guide: Gas Chromatography (GC) (Sept 8-14)

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

Bringing uhplc Performance to the Separation of Peptides

ION CHROMATOGRAPHY SYSTEM S 150

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

High Performance Liquid Chromatography (HPLC) of Three Analgesics

Practical Applications of Method Translation Using the Agilent Method Translation Tool Rita Steed Inside Application Engineer Agilent Technologies

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Sample Preparation. Approaches to Automation for SPE

Chapter 27: Gas Chromatography. Principles Instrumentation Detectors Columns and Stationary Phases Applications

Pittcon P

Multi-mode Separations Using Zirconiabased Stationary Phases

Ensure reproducible Polymeric SPE workflow for high-throughput bioanalysis applications

Chromatographic Analysis

Better HPLC Methods Using Temperature Programming

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Comparison of Solid Core HPLC Column Performance: Effect of Particle Diameter

Chiral separations efficient, fast and productive

High Performance Liquid Chromatography

Do you need trouble-free speed? The NEW Chromolith HR

Remember - Ions are more soluble in water than in organic solvents. - Neutrals are more soluble in organic solvents than in water.

Chemistry Gas Chromatography: Separation of Volatile Organics

Modernizing the USP Monograph for Acetaminophen

Biotage 2012 Webinar series

LIQUID CHROMATOGRAPHY

Do you need trouble-free speed? The NEW Chromolith HR

Instrumental Chemical Analysis

Instrumental Analysis II Course Code: CH3109. Chromatographic &Thermal Methods of Analysis Part 1: General Introduction. Prof. Tarek A.

HPLC. GRATE Chromatography Lab Course. Dr. Johannes Ranke. September 2003

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Chapter 26: An Introduction to Chromatographic Separations

LEARNING OBJECTIVES CHEM 212: SEPARATION SCIENCE CHROMATOGRAPHY UNIT. Thomas Wenzel, Bates College. In-class Problem Set Extraction.

Principles of Gas- Chromatography (GC)

Introduction to Capillary GC

Experiment UPHPLC: Separation and Quantification of Components in Diet Soft Drinks

CHEM 429 / 529 Chemical Separation Techniques

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

2] The plate height in chromatography is best described as 2

Chemistry Instrumental Analysis Lecture 27. Chem 4631

1. Recycled mobile phase could contaminate my samples during the chromatographic run.

Polymer Coated Titania for Analytical and Preparative Reversed-Phase Chromatography

Implementation of Methods Translation between Liquid Chromatography Instrumentation

Fast Analysis of Aromatic Solvent with 0.18 mm ID GC column. Application. Authors. Introduction. Abstract. Gas Chromatography

Introduction to Capillary GC. Page 1. Agilent Restricted February 2, 2011

What is Chromatography?

Shodex TM ODP2 HP series columns

Physical Separations and Chromatography

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Open Column Chromatography, GC, TLC, and HPLC

SEPARATION OF FLURBIPROFEN AND IBUPROFEN ENANTIOMERS ON A CHIRAL STATIONARY PHASE USING SUPERCRITICAL FLUIDS

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

Abstract: An minimalist overview of chromatography for the person who would conduct chromatographic experiments, but not design experiments.

Experiment Nine Thin Layer Chromatography

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Transcription:

ZirChrom Columns and the Metalox 2-C High Temperature Liquid Chromatography Column Heater - The Future of HPLC has Arrived. Welcome to the fifth issue of ZirChrom's electronic newsletter. In response to the overwhelg interest regarding a previous issue on high temperature liquid chromatography, this newsletter will revisit temperature as a cost-saving HPLC tool and the practical application of temperature in HPLC using the Metalox 2-C column heater. ELEVATED TEMPERATURE - HOW IT WORKS Chromatographers have long known that modest increases in operating temperature can dramatically improve both the efficiency and speed of an HPLC separation. For example, in a recent article, David V. McCalley found large increases in the efficiency for basic compounds at elevated temperature 1. McCalley suggested both that basic compounds should be analyzed at higher temperature and that new columns should be developed that are stable at high temperature. Using temperature to affect profound improvements in the speed of analysis, predicted by Antia and Horvath over a decade ago, can be realized through three main effects 2. Firstly, the viscosity of the mobile phase is decreased, so that higher flow rates are possible with existing equipment without increasing backpressure. Secondly, at higher temperature, the diffusion rate of analytes increases so the losses in efficiency associated with increased flow rates are imized 3. Finally, at elevated temperature, the kinetics of the interactions between the analytes and the stationary phase are faster. This will lower the overall analysis time, and often reduce or eliate peak tailing. ELEVATED TEMPERATURE - CHALLENGES Historically, there have been three main challenges to implementing high temperature liquid chromatography: (1) column thermal stability, (2) thermal mismatch broadening, and (3) analyte stability. Elevated temperature can be used with conventional HPLC columns, but can significantly reduce column lifetime. At 6 C, most silica-based columns degrade very quickly, unless operating conditions and buffers are chosen very carefully. To get good column life, a column based on a thermally stable support such as zirconia should be used. Thermal mismatch band broadening is the distortion of chromatographic peaks caused by a radial inequality of temperature across the diameter of the column. This phenomenon is caused by poor heater design; by not ensuring that the incog mobile phase temperature matches that of the column. The four sensor cascadingloop design of the Metalox 2-C eliates thermal mismatch band broadening by ensuring that the temperature within the interior of the column is equilibrated with the temperature of the exterior of the column (See Figure 1). Figure 1. Thermal Mismatch Band Broadening. Metalox 2-C Poorly Designed Column Heater

Some chromatographers (particularly in the pharmaceutical industry) are concerned about the effect of these techniques on temperature-sensitive compounds. Dr. Jon Thompson and Dr. Peter Carr have clearly demonstrated that for high temperature LC, analytes must be thermally stable only for the time scale of the chromatographic run 4. Their study of a number of pharmaceuticals shows that as the time an analyte is exposed to high temperature decreases (as the temperature increases, flow rate is increased, and dwell time is decreased), the likelihood and extent of an on-column dedgredation is greatly diished. ELEVATED TEMPERATURE VS. SHORTER COLUMNS FOR FAST LC The case has been made by others that one may simply shorten the column to increase analysis speed. However, often neglected in these discussions is the loss of resolution that must occur if a shorter column is employed. The following compares and contrasts the benefits/drawbacks of using shorter columns versus elevated column temperature for fast liquid chromatography: Table 1. Comparison of temperature versus shorter columns for fast liquid chromatography. Shorter Columns Elevated Temperature Flexibility Not Flexible. A new column needs to be Very Flexible, a wide range of temperatures allow you to adjust speed upon purchased each time you want to adjust speed. demand and fine tune your separation. Column/Analyte Stability The thermal stability of the column and analyte is not a concern. You must have a column that is up to the challenge of high temperature LC. The gain in analysis speed often prevents any undesirable on-column reactions. Resolution N α 1 k' R s = 4 α 1+ k' Decreasing the column length directly translates into a loss in plate count, as N is directly proportional to L; this then translates into a loss in resolution according to the general resolution equation. This initial loss in resolution can be overcome somewhat by increasing the rentention factor through a weakening of the mobile phase, however this is counterproductive in terms of improving speed. The use of elevated temperature to decrease the viscosity of the eluent allows higher flow rates and therefore faster analyses, without sacrificing resolution through a decrease in plate count.

ELEVATED TEMPERATURE - SAFETY CONCERNS Some scientists worry that their mobile phase will boil in the columns at higher temperatures causing damage to their equipment and/or a safety hazard in the lab. It is important to remember, however, that the extremely high pressure in an HPLC column raises the boiling points of HPLC solvents, so that flashing cannot occur. Below 8 C, it is not necessary to modify a standard HPLC system to operate safely. The tubing from the column to the detector and from the detector to the waste receptacle is sufficient to cool the mobile phase back to room temperature. Above 1 C, adding a backpressure regulator, such as the one included with the Metalox 2-C, after the detector to keep about 3 bar on the system is generally enough to prevent flashing. At very high temperature (~15 C), it is important to cool the mobile phase downstream of the column and before the detector. The Metalox 2-C incorporates this feature by using its efficient heated exchanger design to cool 2 C water mobile phase at a flow rate of 6 ml/ down to 8 C before leaving the column heater. Another safety concern addressed by the engineers of the Metalox 2-C is the possibility of a small leak in the column connection inside the heating chamber. The smaller, energy efficient, oven design of the Metalox 2-C eliates the large air volumes that can trap volatile vapors from a connection leak. ELEVATED TEMPERATURE - THE BOTTOM LINE Elevated temperature can allow some separations not possible at ambient temperatures, however the main advantage of using high temperature is faster analysis times. The Metalox 2-C can help you to increase your laboratory's throughput, sometimes obviating the need to buy additional expensive HPLC systems. The chromatograms in Figure 2 clearly demonstrate the gains in speed (12-fold improvement!) that can be made without losing resolution by simply increasing column temperature. Figure 2. Analysis of Pharmaceuticals at 21 C and 14 C - 12 fold decrease in analysis time. 21 C LC Conditions: Mobile Phase, 26.5/73.5 ACN/5mM Tetramethylammonium hydroxide, ph 12.2; Flow Rate, 1.35 ml/.; Injection volume,.2 ul; 254 nm detection; Column Temperature, 21 C; Pressure drop = 195 bar; Solutes: 1=Doxylae, 2=Methapyrilene, 3=Chlorphenirae, 4=Triprolidine, 5=Meclizine 1mm x 4.6mm ZirChrom -PBD 3 6 1 5 4 3 2 3 4 2 Temperature: 21 o C Flow rate: 1.35 ml/. Pressure drop: 195 bar Resolution (2,3): 2.1 Analysis time: 12.5 2 1 2.4 2.6 2.8 3 3.2 5 2 4 6 8 1 12 14 14 C LC Conditions: Mobile Phase, 2.5/79.5 ACN/5mM Tetramethylammonium hydroxide, ph 12.2; Flow Rate, 4.2 ml/.; Injection volume,.5 ul; 254 nm detection; Column Temperature, 14 C; Pressure drop = 194 bar; Solutes: 1=Doxylae, 2=Methapyrilene, 3=Chlorphenirae, 4=Triprolidine, 5=Meclizine 1mm x 4.6mm ZirChrom -PBD 7 6 5 4 3 2 1 1 3 4 7 6 5 2 5 4 3 2 1.25.5.75 1 12 - fold Faster!.48.52.56.6.64 Temperature: 14 o C Flow rate: 4.2 ml/. Pressure drop: 194 bar Resolution (2,3): 2.1 Analysis time:.85 utes -1 2 4 6 8 1 12 14

Table 2 is an example of the the final analysis generated by a value assessment program used by ZirChrom using the data from Figure 2. This assessment can be customized to your specific application to quantitate how temperature can help your productivity. Contact a ZirChrom representative today to help adapt this value assessment model to your specific analysis. Table 2. Cost Effectiveness of Analysis Time Decrease.

The Bottom Line: A Case Study The following case study demonstrates the cost savings that were actually realized by using elevated column temperature. This summary represents a customer experience using the Metalox 2-C column heater and ZirChrom columns. Surface Specialties UCB is a company located in Smyrna, Georgia who manufacturers specialty chemicals, coating resins, additives, adhesives, and technical resins. Surface Specialties UCB approached ZirChrom method developers with the challenge of shortening the run time of an analysis of mono- to di- ester ratio in a final polymer product. The current methodology for Surface Specialties UCB s analysis of the mono- to di-ester ratio in a final polymer product, specifies an HPLC method which is 3 utes in length. Two injections are required for each process sample bringing the total analysis time for each process sample to approximately 6 utes. This analysis is used to monitor in-process reactions to detere completion. Using the current method, the pertinent information regarding reaction completion would be obtained when it was no longer relevant, that is when the reaction had already gone too far. ZirChrom Solution: Use temperature to speed up the analysis! Figure 3 shows what ZirChrom and Metalox method developers did for the customer s separation. Customer Allyson Norman, Analytical Scientist with Surface Specialties UCB had this to say about the ZirChrom method; ZirChrom method developers reduced our analysis turn around time from 1 hour to 1 utes! The ZirChrom value assessment program predicts reducing the total analysis time from 6 utes (3 utes/injection) to 1 utes (5 ute/injection) will save Ms. Norman s company roughly $2./sample in total analysis costs. This translates to roughly $158,6/year in savings (savings based on possible cycles/instrument/year using the the ZirChrom column). The savings are after the cost of purchasing the Metalox 2-C high temperature column heater had been factored into the ZirChrom analysis overhead. Although these cost savings are impressive, and beneficial to the customer, having the analysis completed before the reaction had gone too far is priceless. Figure 3. Separation of Mono and Di-ester at 8 C using ZirChrom-PBD and the Metalox 2-C. 7 Di-ester 6 5 4 3 2 1 Mono-ester 1 2 3 4 5 6 Time (.) Separation of mono- and di-esters from BPA(EO)3DMA methacrylated polyol. LC Conditions: Gradient elution from 2/8 ACN/water to 8/2 ACN/water over 5 utes; Flow rate, 1.5 ml/.; Temperature, 8 o C; Injection volume, 5 µl; Analyte concentration is approximately 1 mg/ml; Detection at 24 nm; Backpressure, 155 bar; Column, 15 mm x 4.6 mm i.d. ZirChrom -PBD

HIGH TEMPERATURE LC BECOMES A REALITY The innovations of the Metalox 2-C enables the chromatographer to take advantage of the increased speed of high temperature while eliating obstacles to high temperature liquid chromatography such as irreproducibility, thermal mismatch band broadening and mobile phase overheating. The revolutionary design of the Metalox 2-C column heater incorporates a four sensor cascading loop control, a patented active shield adiabatic column jacket and an energy efficient micro heat exchanger (See Figure 4). Figure 4. Metalox 2-C. For more information on high temperature liquid chromatography and full specifications on the Metalox 2-C high temperature column heater contact Metalox at www.metalox.com or 763-421-337. As always, ZirChrom's innovative technical support staff would be happy to assist you in applying this cutting edge technology to your application. Please contact them at support@zirchrom.com or 1-866-STABLE1. Please visit our website: www.zirchrom.com. REFERENCES 1. McCalley, D. J. Chrom. A 92, 311-321 (2) 2. Antia, F.; Horvath, C. J. Chrom. 435, 1-15 (1988) 3. Li, J.W; Carr, P.W. Anal. Chem., 69(5), 837-843 (1997) 4. Thompson, J.; Carr, P.W. Anal. Chem. 74, 117-123 (22)