arxiv: v3 [physics.ins-det] 13 Dec 2016

Similar documents
Measurement of nuclear recoil responses of NaI(Tl) crystal for dark matter search

arxiv: v1 [physics.ins-det] 29 Jun 2011

D. Medvedev GEMMA and vgen Nalchik, June 6, Investigation of neutrino properties with Ge detectors on KNPP

The 46g BGO bolometer

Neutron flux measurement using fast-neutron activation of 12 B and 12 N isotopes in hydrocarbonate scintillators

Detectors for the COHERENT neutrino experiment R. Tayloe Indiana U. for the COHERENT collaboration

The fast light of CsI(Na) crystals

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

This paper should be understood as an extended version of a talk given at the

First tests of the big volume ultra low background gamma spectrometer

A Trial of Neutrino Detection from Joyo Fast Research Reactor

The Search for θ13 : First Results from Double Chooz. Jaime Dawson, APC

Sensitivity of sodium iodide cryogenic scintillation-phonon detectors to WIMP signals

arxiv: v1 [physics.ins-det] 27 Sep 2018

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Status of KIMS-NaI experiment

arxiv: v2 [physics.ins-det] 8 Feb 2013

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

Figure 1. Decay Scheme for 60Co

Scintillation efficiency measurement of Na recoils in NaI(Tl) below the DAMA/LIBRA energy threshold

David Reyna Belkis Cabrera-Palmer AAP2010, Japan

Background Neutron Studies for Coherent Elastic Neutrino-Nucleus Scattering Measurements at the SNS

arxiv: v1 [physics.ins-det] 3 Feb 2011

Activation Analysis. Characteristic decay mechanisms, α, β, γ Activity A reveals the abundance N:

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

arxiv: v1 [physics.ins-det] 22 Dec 2016

Cherenkov Detector. Cosmic Rays Cherenkov Detector. Lodovico Lappetito. CherenkovDetector_ENG - 28/04/2016 Pag. 1

ANAIS: Status and prospects

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

Observation of Reactor Antineutrinos at RENO. Soo-Bong Kim for the RENO Collaboration KNRC, Seoul National University March 29, 2012

THE COMPTON EFFECT Last Revised: January 5, 2007

arxiv:hep-ex/ v1 15 Aug 2006

Quality Assurance. Purity control. Polycrystalline Ingots

Detection and measurement of gamma-radiation by gammaspectroscopy

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

Daya Bay and joint reactor neutrino analysis

DETECTORS. I. Charged Particle Detectors

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

PARTICLES REVELATION THROUGH SCINTILLATION COUNTER

The COHERENT Experiment: Overview and Update of Results

Oak Ridge National Laboratory, TN. K. Scholberg, Duke University On behalf of the COHERENT collaboration August 2, 2017 DPF 2017, Fermilab

1 of :32

REFERENCE SOURCES FOR THE CALIBRATION OF THE AUTOCORRELATION SINGLE-CRYSTAL SCINTILLATION TIME SPECTROMETER

Neutrinos. Why measure them? Why are they difficult to observe?

Background and sensitivity predictions for XENON1T

Single Channel Beta-Gamma Coincidence Detection of Radioactive Xenon Using Digital Pulse Shape Analysis of Phoswich Detector Signals

anti-compton BGO detector

Simulation of 4π HPGe Compton-Suppression spectrometer

章飞虹 ZHANG FeiHong INTERNATIONAL SCHOOL OF SUBNUCLEAR PHYSICS Ph.D. student from Institute of High Energy Physics, Beijing

The DarkSide-50 Outer Detectors

Status of the ANAIS experiment at Canfranc

Background Studies for the XENON100 Experiment. Alexander Kish Physics Institute, University of Zürich Doktorandenseminar August 30, 2010 UZH

Preparatory experiments for cold-neutron induced fission studies at IKI

Measurements of liquid xenon s response to low-energy particle interactions

Reactor On/Off Monitoring with a Prototype of Plastic Anti-neutrino Detector Array (PANDA)

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Update on Calibration Studies of the Canadian High-Energy Neutron Spectrometry System (CHENSS)

Measurements of Neutron Total and Capture Cross Sections at the TOF spectrometers of the Moscow Meson Factory

Precision neutron flux measurement with a neutron beam monitor

Physics Dept. PHY-503-SEMESTER 112 PROJECT. Measurement of Carbon Concentration in Bulk Hydrocarbon Samples

arxiv: v2 [nucl-ex] 24 Jul 2015

SCINTILLATION DETECTORS AND PM TUBES

Measurement of prompt fission γ-ray spectra in fast neutroninduced

Gamma ray coincidence and angular correlation

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

Photoneutron reactions studies at ELI-NP using a direct neutron multiplicity sorting method Dan Filipescu

Pulsed Neutron Interrogation Test Assembly - PUNITA

Mass Yield Distribution in the Photon-induced Fission of 232 Th, 238 U, nat Pb, and 209 Bi

Results from 730 kg days of the CRESST-II Dark Matter Search

Results on geoneutrinos at Borexino experiment. Heavy Quarks and Leptons Yamagata Davide Basilico

XMASS: a large single-phase liquid-xenon detector

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

THE INSTALLATION FOR EXPERIMENTAL NEUTRON SPECTRA RESEARCH IN REACTOR MATERIALS COMPOSITIONS Hliustin D.V. Institute for Nuclear Research, Moscow,

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

He-3 Neutron Detectors

ANAIS: Status and prospects

Absolute activity measurement

Characterization and Monte Carlo simulations for a CLYC detector

Chapter 3: Neutron Activation and Isotope Analysis

Walter C. Pettus University of Wisconsin Madison. Weak Interactions Discussion Group Yale Physics 21 Oct 2013

The Daya Bay Reactor Neutrino Experiment

The relevance of XENON10 constraints in this low-mass region has been questioned [15] C.E. Aalseth et al. arxiv: v1

A POSITION SENSITIVE ALPHA PARTICLE DETECTOR BASED ON A LYSO CRYSTAL AND A MICRO-PIXEL AVALANCHE PHOTODIODE

R. MacLellan on behalf of the EXO Collaboration Department of Physics & Astronomy, University of Alabama, Tuscaloosa AL USA

Compton suppression spectrometry

- The CONUS Experiment - COherent elastic NeUtrino nucleus Scattering

Louis Baum University of Michigan, REU Student Summer UM Nuclear Sciences Group

Total probability for reaction Yield

A. Aleksanyan, S. Amirkhanyan, H. Gulkanyan*, T. Kotanjyan, L. Poghosyan, V. Pogosov

arxiv:physics/ v1 3 Aug 2006

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Neutron interactions and dosimetry. Eirik Malinen Einar Waldeland

LOW ENERGY SOLAR NEUTRINOS WITH BOREXINO. Lea Di Noto on behalf of the Borexino collaboration

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

Waveform Analysis for DM-Ice17. Zachary Pierpoint University of Wisconsin - Madison October 21, 2013 Yale Weak Interactions Discussions Group

Rice University Physics 332 LIFETIME OF THE MUON I. INTRODUCTION...2! II. MEASUREMENT PROCEDURES...3! III. ANALYSIS PROCEDURES...7!

Dependence on neutron energy of neutron induced peaks in Ge detectors. E. Gete, D.F. Measday B.A. Moftah, M.A. Saliba, T.J. Stocki

Compton Imaging with Coincidence Measurements for Treaty Verification Purposes

The Generalized Centroid Difference Method

Past searches for kev neutrinos in beta-ray spectra

Transcription:

arxiv:1608.02409v3 [physics.ins-det] 13 Dec 2016 Sensitive neutron detection method using delayed coincidence transitions in existing iodine-containing detectors E. Yakushev a,, S. Rozov a, A. Drokhlyansky b, D. Filosofov a, Z. Kalaninova a,c, V. Timkin a, D. Ponomarev a a Dzhelepov Laboratory of Nuclear Problems, JINR, Joliot-Curie 6, 141980 Dubna, Russia b Department of Physics, MIT, Cambridge, MA 02139, USA c Department of Nuclear Physics and Biophysics, Comenius University, 84248 Bratislava, Slovakia Abstract This work explains a new, highly sensitive method for the detection of neutrons, which uses the T 1/2 = 845 ns delay in the decay of 128 I at the 137.8 kev energy level, resulting from the capture of thermal neutrons by iodine nuclei in NaI and CsI scintillation detectors. The use of delayed coincidence techniques with a several µs delay time window for delayed events allows for the highly effective discrimination of neutron events from any existing background signals. A comparison of ambient neutron measurements between those identified through the suggested method from a cylindrical, ø63mm 63mm NaI(Tl) scintillator and those from a low-background proportional 3 He counter experimentally demonstrates the efficacy of this neutron detection method. For an isotropic, 4π, thermalneutronflux of1ncm 2 s 1, the absolutesensitivityofthe NaI detector was found to be 6.5±1countss 1 with an accidental coincidence background of 0.8eventsday 1 for any delay time window of t = 1µs. The proposed method can provide low-background experiments, using NaI or CsI, with measurements of the rate and stability of incoming neutron flux to a greater accuracy than 10 8 ncm 2 s 1. Keywords: Neutron detection, NaI, CsI Corresponding author Email address: yakushev@jinr.ru (E. Yakushev) Preprint submitted to Nuclear Instruments and Methods in Physics Research ADecember 14, 2016

1. Introduction The search for alternative neutron detectors to replace those that use 3 He presents a pressing issue in modern physics[1, 2]. The fairly low cost, widespread availability, and ease of use of NaI(Tl), CsI(Tl), CsI(Na), and CsI(pure) scintillation detectors makes their implementation for the detection of neutrons an incredible opportunity. Neutrons have previously been detected by these scintillation devices through various approaches (see Table 1). Table 1: Prior approaches for neutron detection with NaI and CsI Reference Detector Neutrons Short description [3] NaI thermal boron lining with available NaI detectors [4] NaI thermal high-energy photons following (n,γ) reactions in the NaI [5, 6] NaI(Tl) thermal triple β γ γ coincidences in two detectors following (n,γ) reactions on 23 Na [7] NaI thermal activated NaI detector ( 128 I β decay, T 1/2 = 25min and 24 Na β decay, T 1/2 = 15h) [8] CsI(Na) fast 57.6 kev signal from 127 I(n,n ) inelastic scattering [9] NaI(Tl), CsI(Tl) fast 1-200 MeV neutrons, (n,p) and (n,α) reactions, pulse-shape discrimination It is important to note that, in [4], when a NaI spectrometer was compared to a 3 He-based portal monitor with a comparable active volume, the detection efficiencies and minimum detectable activities of the devices were found to be similar. In general, neutron measurements with NaI and CsI detectors require accurately accounting for background signals in the neutron detection region of interest because of the high sensitivity of these detectors to cosmic and γ-rays. To efficiently discriminate neutron events from background signals, the neutron 2

detection method proposed in this work uses delayed coincidence techniques with a short delay time window. 2. Description of the method Iodine has only one stable isotope: 127 I. This isotope has a cross section for thermal neutron capture of σγ 0 = 6.2±0.2 b [10], which is 860 times lower than 3 He s cross section of 5333 ± 7 b. However, it is important to note that NaI (solid) has 109 times as many moles as an equal volume of 3 He (gas, 500 kpa), and CsI (solid) has 77 times as many moles. Thus, despite its relatively low cross section, the fairly small ø63mm 63mm NaI(Tl) detector (used for the experimentdescribedinthiswork,andhenceforthreferredtowith 63 63 NaI)has an 50% neutron capture (on 127 I) effectiveness, as obtained from Geant4 [11] modeling based on assumptions about the uniform thermal neutron flux (the Maxwell-Boltzmann distribution at room temperature). 128 I in its excited state (6.8 MeV) is produced as a result of neutron capture, and its decay to the ground state proceeds through a series of low-energy levels (see Table 2). This decay process often includes the energy level 137.8 kev with T 1/2 = 845±20ns. To identify neutron capture by iodide in a detector, thereby measuring neutron flux, measurements of the following delayed coincidences by the same detector can be used: the decay transition from 6.8 MeV to 137.8 kev (the neutron prompt signal) and the transition from 137.8 kev to the ground state (the neutron delayed signal). According to [12], following neutron capture by iodide, 40±10% of all deexcitations pass through the 137.8 kev energy level. This energy level is filled and emptied via a series of low-energy, highly converted transitions, including the 4.2 kev transition, which has never been experimentally investigated on its own. These transitions raise uncertainty about the probability of decay via this energy level, causing uncertainty when estimating the detector s overall sensitivity. The lack of direct measurements of low-energy γ-transition intensities and of internal conversion coefficients also results in significant uncertainty in 3

Table 2: 128 I excited energy levels below 200 kev and their decay transitions (from [10] and [12]). Energy level T 1/2 Energy levels in 128 I (kev) (ns) following decay (kev) 180 160.8, 85.5, 27.4 167.4 175±15 137.8 160.8 27.4, 0 151.6 85.5, 27.4 144.0 133.6 137.8 845±20 133.6, 85.5 133.6 12.3±0.5 85.5, 27.4, 0 128.2 85.5 85.5 27.4 27.4 0 0 the detector s effectiveness at recording neutron prompt and delayed events. Nevertheless, Geant4 MC s estimations obtain a >75% absorption probability for low-energy γ-rays and electrons released in the 63 63 NaI detector, following neutron capture. Thus, the overall effectiveness of this NaI detector at detecting neutrons is roughly estimated with performed MC to be 10% and has significant uncertainties, as described above. 3. The Experiment For experimental verification of the suggested method, a simple spectrometer was created, as shown in Fig. 1. A 3 PMT R6091 (Hamamatsu) was attached to a cylindrical, ø 63 mm 63 mm NaI(Tl) scintillator via optical grease, and this device was placed in a 5-cm thick lead brick well. The top part of this lead brick shield was left open. A cardboard box, covered along the inside in black paper, shielded the detector from light. A CAEN DT5780 Dual Digital Multi Channel Analyzer collected data using an event by event list mode. Consecutive events 4

Figure 1: On left: NaI spectrometer inside lead shield (front side of shield removed). 1) ø63 63 mm NaI(Tl) scintillator, 2) R6091 PMT, 3) lead bricks. On right: NaI and 3 He neutron spectrometers during data acquisition. 4) Black box with NaI detector inside, 5) CHM-57 3 He filled proportional counter, 6) 3 He neutron detector s preamplifier, 7) DT5780 Dual Digital Multi Channel Analyzer used to acquire data from both detectors. within a delay time smaller than 1.8µs could not be properly registered due to the NaI scintillator s 250 ns decay time, after-pulses in the PMT, and impulse shapes with tails extending up to approximately 1.5 µs after the initial peak. Therefore, 1.8 µs was chosen as the trigger holdoff. With an energy threshold slightly below 100 kev, the total count rate of the detector was 7.3 Hz. The energy response in the 137 kev expected region for delayed signals was calibrated with measurements collected in the presence of a 139 Ce radioactive source (165.9 kev γ-line). In the first successful test following the calibration measurements, ahighlyactive(>10 4 ns 1 ) PuBeneutronsourcewasusedtosee if the number of neutron events could be measured using a NaI scintillator via the suggested method (Fig. 2). This test did not involve any special moderators: fast neutrons from the source were thermalized by surrounding materials. Ambient neutron measurements using the aforementioned spectrometer were conducted in one of the buildings of JINR s Laboratory of Nuclear Problems (Dubna, Russia, 120 m above sea level). Simultaneously, a low-background 3 He neutron detector (CHM-57 [13, 14, 15]) also performed neutron flux measurements, as shown in Fig. 1. This 3 He detector had a neutron sensitivity, 5

Figure 2: Delayed coincidences registered without (left half of each graph) and in the presence of (right half of each graph) the PuBe neutron source. Each dot represents one coincidence event. The upper graph shows coincidences with delayed events in the 137 kev region, i.e. ADC channels from 150 to 350 (see Fig. 3). During the run with the PuBe source, the number of coincidence events in the upper graph is evidently greater for a delay time of t<7 µs than for a larger delay time. The lower graph shows delayed coincidence events registered from ADC channel 1000 to 8000 (well above the expected signal for a neutron event). In this graph, the noticeable increase of random coincidences for the run with the PuBe source, as compared to that without it, does not depend on the delay time. 6

which refers here and hereafter to the isotropic, 4π, 1ncm 2 s 1 thermal neutron flux in the detector s absence, of 243±24countss 1. Fig. 3 displays the experimental energy spectra obtained by the NaI(Tl) detector over the course of 42 days of measurements from May to June, 2016. As evident from these spectra, it is impossible to discern neutron events from background signals without using coincidence detection techniques to distinguish the delayed event line in the 137 kev energy region. The T 1/2 of 825±12 ns (Fig. 4), obtained from measurements for this energy level, agrees with the tabulated value of 845 ± 20 ns [10]. Since systematic effects on the determination of T 1/2, such as event time precision, were not studied in this work, the acquired T 1/2 value should not be considered an improvement of the tabulated one. The 214 Bi 214 Po peak in coincidence events in data from measurements with a delay time window of 10 to 500 µs helps to indirectly verify the delay time window approach to identifying coincidence events. The experimentally acquired T 1/2 = 168.3 ± 10.8 µs for 214 Po agrees with the tabulated value of 164.3±2.0 µs [10]. Fig. 5 compares the neutron flux measured by the 63 63 NaI detector with that measured simultaneously by the low-backgroundproportional 3 He counter, thereby demonstrating the sensitivity of the NaI-based neutron detection approach. Both spectrometers detected the small changes in ambient neutron flux, on the level of 10 3 ncm 2 s 1, caused by the operation of one of JINR s acceleration facilities. Based on analyses of the simultaneous measurements from the two detectors, the absolute sensitivity of the 63 63 NaI spectrometer was found to be 6.5 ± 1countss 1 for a neutron flux of 1ncm 2 s 1 (without accounting for loss of effectiveness due to the 1.8 µs trigger holdoff). Meanwhile, the number of coincidence events occurring within a delay time window of 1 µs was determined to be 0.8 day 1 based on the constant background signal for a delay time greater than 10µs (see Fig. 4), as well as on matching calculations with known event count rates above the energy threshold and in the 137 kev energy region. 7

Figure 3: The experimental energy spectra measured during 42 days in the LNP, JINR with a 63 63 NaI spectrometer. Black dots - energy spectrum without any cuts; blue dots with error bars and red triangles - neutron prompt and neutron delayed spectra, respectively (delay time window is 1.8 10 µs, no ADC window cuts were applied, neutron events in the delayed spectrum are in a peak corresponding to ADC channels 150-350); green dots - delayed events with delay time window from 10 to 500 µs. Insert: blue filled area - delayed event spectrum with delay time window from 1.8 to 10 µs (i.e. neutron events), asymmetrical peak shape caused by prompt signal influence on delayed signals; red squares - delayed event spectrum with shifted delay time window (11.8 to 20 µs); dots with error bars - calibration with 139 Ce (experimental calibration spectrum scaled down to match amplitude of delayed event spectrum). 8

Figure 4: Delayed coincidences. Upper graph shows 214 Po s α-decay. Lower decay curve illustrates 137 kev level s T 1/2. On both plots, dots with error bars correspond to observed coincidences with particular delay times. Solid lines show the fit of the function: f = constant background + A expe ln(2)t/t 1/2, from which the half-lives of the data sets can be determined. 9

He detector 3 s -1 ) measured by -2 Neutron flux (m 40 35 30 25 20 15 10 5 0 09h 30/05 09h 01/06 09h 03/06 09h 05/06 09h 07/06 09h 09/06 09h 11/06 09h 13/06 Time (hour dd/mm) 40 35 30 25 20 15 10 5 0 Neutron count rate per 2 h registered by NaI spectrometer Figure 5: Comparison of neutron flux measured by 3 He detector and number of neutron events registered by NaI spectrometer (from measurements taken in May-June, 2016). Black dots with error bars - neutron flux from 3 He detector; red triangles with error bars - neutron count rate from 63 63 NaI spectrometer. 10

4. Discussion Multiplying the event count rates in the prompt and delayed energy regions yields the frequency of coincidence events comprising the background signal for the suggested method of neutron measurement, which is almost quadratically proportional to the overall background signal. Thus, the proposed method is especially sensitive in low-background experiments that use iodine-containing detectors with masses of 10s or 100s of kilograms as active veto systems or as the main detectors. Some examples of these types of experiments include the DAMA/LIBRA dark matter search experiment, which uses a 250 kg NaI(Tl) detector [6]; the KIMS dark matter search experiment, which implements a 103 kg CsI(Tl) detector [16]; the νgen reactor neutrino nuclear coherent scattering experiment, which uses an approximately 400 kg NaI(Tl) anti-compton veto system [17]; and the COHERENT experiment, which uses a 14 kg CsI(Na) detector to search for coherent elastic neutrino scattering from the Spallation Neutron Source [18]. In the aforementioned experiments, neutrons comprise one of the most uncertain sources of background events. Considering the sensitivity calculated for the 63 63 NaI scintillatordescribed in thiswork, it is alsopossible toestimate the ability to detect the level and stability of thermal neutron flux in low-background experiments. For a thermal neutron flux on the level of 10 8 ncm 2 s 1, approximately 1 neutron per day can be detected with a 100 kg NaI detector (the precise number can only be estimated after accounting for the influence of the detector s geometry on neutron capture efficiency and the detection of prompt and delayed signals). For many low background experiments, only the detection of fast neutrons, which is a difficult and often even impossible task, is of interest. However, since no thermal neutron sources exist in nature, the thermal neutron flux is always in equilibrium with the fast neutron flux. Thus, despite the typically unknown ratio of fast to thermal neutrons, the measurement of thermal neutrons provides useful information about the total neutron flux and stability. For example, in [6], the upper limit on the thermal neutron flux pass- 11

ing through the multicomponent DAMA/LIBRA shield was determined to be: < 1.2 10 7 cm 2 s 1 (90% C.L.). The majority of existing neutron detectors are used for nuclear safeguards, security, and reactor instrumentation. The golden standard among such detectors is the 3 He-filled proportional counter with its high neutron detection efficiency and simultaneously low sensitivity to γ-radiation. A thorough comparison of NaI detectors with 3 He detectors in the particular case of neutron portal monitors already exists in [4]. Along with all other iodine-containing detectors, NaI spectrometers with comparable active volumes to 3 He-based portal monitors have similar detection efficiencies and minimum detectable activities. The strong suppression of γ- background radiation marks the main advantage of the delayed coincidence approach to the detection of neutrons via an NaI (CsI) spectrometer. At the same time, the 1.8µs trigger holdoff and the fact that not all of the transitions pass through the delayed 137 kev level reduce the efficiency by a factor of 10, which can be prevented through improved data acquisition and/or a different light detector. To implement the proposed approach in a high intensity neutron field, the important, degrading effect of high-dose fast neutron bombardment on crystals must be taken into account. For large detectors, such as that used in [4] or larger, a subsequent measurement of the total, high-energy transition cascade (above the natural radioactivity threshold) coupled with measurements from the delayed 137.8 kev energy level can effectively suppress background signals, even with a high γ-count rate. This differs from the NaI detector used in this experiment and other relatively small detectors, where only a fraction of events in the high-energy cascade from 6.8 MeV to 137.8 kev are registered. Another important point of discussion is the detection of neutron events with a high multiplicity (neutrons from spontaneous fission, those produced by high energy muons in surrounding detector materials, etc). The proposed method can measure such events only after careful consideration and changes in the experiment: conducting the experiment with a short delay time window for prompt-delayed events of < 3µs would likely still not exceed the average time 12

between neutron production and capture in the detector. The decay process of 128 I has another notable excited state at 167.4 kev, which has a T 1/2 of 175±15 ns (Table 2). This energy level is emptied exclusively via a 29.6 kev transition to the aforementioned 137.8 kev energy level, providing a potential way to radically suppress background signals through triple coincidence measurements. However, this goal necessitates the detection of delayed events in a time window of 100s of ns. This is a difficult task when using NaI, and especially CsI, scintillators because they have a decay time of 200 500 ns. Triple coincidence measurements were not investigated in this research. A similar neutron detection method can be implemented for Ge-detectors by using 73 Ge s delayed transitions from the 13.3 kev (T 1/2 = 2.95µs) and 66.7 kev (T 1/2 = 0.499s) energy levels, where the latter is only helpful in ultra-low-background measurements. However, it is important to note several experimental differences: 72 Ge s thermal neutron capture cross section of 0.98 b is 6 times smaller than that of 127 I, and the 72 Ge isotope only comprises 27.7% of the atoms in nat Ge. Furthermore, unlike 128 I, 73 Ge is a stable isotope, so it can be excited to the aforementioned energy levels by fast neutron inelastic scattering, causing ambiguous results. For low-background neutron measurements, the cosmogenic isotope 73 As s decay needs to be accounted for in the analysis. Also, in a Ge-detector it is necessary to consider the influence of the cold cryostat, the amount of nitrogen in the Dewar vessel, and the vessel itself on the incoming neutron energy distribution (i.e. the neutron capture cross section). 5. Conclusion In summary, this work proposes a fundamentally new neutron detection technique involving spectrometers with existing, iodine-containing (NaI or CsI) scintillation detectors. The additional use of delayed coincidence techniques allows for the highly effective discrimination of neutron events from background signals. The precise measurements from a simple, inexpensive NaI(Tl) spec- 13

trometer of the ambient neutron flux at sea-level demonstrate the sensitivity of this technique. Acknowledgments This work has been funded by the Russian Science Foundation under grant 14-12-00920. A. Drokhlyansky would like to thank MIT Science and Technology Initiatives for their support. References References [1] R. Kouzes, J. Ely, L. Erikson, W. Kernan, A. Lintereur, E. Siciliano, D. Stephens, D. Stromswold, R. V. Ginhoven, M. Woodring, Nucl. Instrum. Methods Phys. Res., Sect. A 623 (3) (2010) 1035 1045. doi:http://dx.doi.org/10.1016/j.nima.2010.08.021. [2] R. Kouzes, A. Lintereur, E. Siciliano, Nucl. Instrum. Methods Phys. Res., Sect. A 784 (2015) 172 175, symposium on Radiation Measurements and Applications 2014 (SORMA XV). doi:http://dx.doi.org/10.1016/j.nima.2014.10.046. [3] W. Metwally, Nucl. Instrum. Methods Phys. Res., Sect. B 338 (2014) 48 51. doi:http://dx.doi.org/10.1016/j.nimb.2014.08.001. [4] P. Holm, K. Perajarvi, A.-P. Sihvonen, T. Siiskonen, H. Toivonen, Nucl. Instrum. Methods Phys. Res., Sect. A 697 (2013) 59 63. doi:http://dx.doi.org/10.1016/j.nima.2012.09.010. [5] R. Bernabei, P. Belli, R. Cerulli, F. Montecchia, M. Amato, G. Ignesti, A. Incicchitti, D. Prosperi, C.J. Dai, H.L. He, H.H. Kuang, J.M. Ma, Eur. Phys. J. C 18 (2) (2000) 283 292. doi:10.1007/s100520000540. 14

[6] R. Bernabei, et al., Nucl. Instrum. Methods Phys. Res., Sect. A 592 (3) (2008) 297 315. doi:http://dx.doi.org/10.1016/j.nima.2008.04.082. [7] A. S. Kuznetsov, G. N. Malyshkin, A. N. Makarov, I. N. Sorokin, Y. S. Sulyaev, S. Y. Taskaev, Technical Physics Letters 35 (4) (2009) 346 348. doi:10.1134/s1063785009040178. [8] J. Collar, N. Fields, M. Hai, T. Hossbach, J. Orrell, C. Overman, G. Perumpilly, B. Scholz, Nucl. Instrum. Methods Phys. Res., Sect. A 773 (2015) 56 65. doi:http://dx.doi.org/10.1016/j.nima.2014.11.037. [9] C. Bartle, R. Haight, Nucl. Instrum. Methods Phys. Res., Sect. A 422 (1-3) (1999) 54 58. doi:http://dx.doi.org/10.1016/s0168-9002(98)01062-6. [10] R. Firestone, et al., Table of Isotopes, 8th Edition, New York: Wiley, 1998. [11] S. Agostinelli, et al., Geant4a simulation toolkit, Nucl. Instrum. Methods Phys. Res., Sect. A 506 (3) (2003) 250 303. doi:http://dx.doi.org/10.1016/s0168-9002(03)01368-8. [12] S. Sakharov, et al., Nuclear Physics A 528 (2) (1991) 317 347. doi:http://dx.doi.org/10.1016/0375-9474(91)90092-k. [13] G. Vidyakin, et al., Prib. Tekh. Eksp. 32 (4) (1989) 70 73. [14] S. Rozov, et al., Bulletin of the Russian Academy of Sciences: Physics 74 (4) (2010) 464 466. [15] S. Rozov, et al., ArXiv e-printsarxiv:1001.4383. [16] H. Lee, et al., Phys. Rev. D 90 (2014) 052006. doi:10.1103/physrevd.90.052006. [17] V. Belov, et al., Journal of Instrumentation 10 (12) (2015) P12011. doi:10.1088/1748-0221/10/12/p12011. 15

[18] D. Akimov, et al., ArXiv e-printsarxiv:1509.08702. 16