Estimation of acoustical streaming: theoretical model, Doppler measurements and optical visualisation

Similar documents
INVESTIGATION OF ACOUSTIC STREAMING JETS IN LIQUID

Density Field Measurement by Digital Laser Speckle Photography

TRACKING OF THERMAL STRUCTURES FROM INFRARED CAMERA BY PIV METHOD

SCATTERING OF ULTRASONIC WAVE ON A MODEL OF THE ARTERY J. WÓJCIK, T. POWAŁOWSKI, R. TYMKIEWICZ A. LAMERS, Z. TRAWIŃSKI

DETERMINATION OF THE B/A OF BIOLOGICAL MEDIA BY MEASURING AND MODELING NONLINEAR DISTORTION OF PULSED ACOUSTIC WAVE IN TWO-LAYER MEDIA TAMARA KUJAWSKA

Today s menu. Last lecture. Measurement of volume flow rate. Measurement of volume flow rate (cont d...) Differential pressure flow meters

On the study of elastic wave scattering and Rayleigh wave velocity measurement of concrete with steel bar

Abstract Particle image velocimetry (PIV)

Output intensity measurement on a diagnostic ultrasound machine using a calibrated thermoacoustic sensor

Today s menu. Last lecture. Ultrasonic measurement systems. What is Ultrasound (cont d...)? What is ultrasound?

A Study of the Motion of Particles in Superfluid Helium-4 and Interactions with Vortices

Effect of Liquid Viscosity on Sloshing in A Rectangular Tank

Simultaneous Velocity and Concentration Measurements of a Turbulent Jet Mixing Flow

APPENDIX Tidally induced groundwater circulation in an unconfined coastal aquifer modeled with a Hele-Shaw cell

Advanced Computational Methods in Heat Transfer - eat Tra nsf er EDITORS: A.J. Nowak Silesian Technical University, Poland

Particles, drops, and bubbles. Lecture 3

Doppler echocardiography & Magnetic Resonance Imaging. Doppler echocardiography. History: - Langevin developed sonar.

SIMULTANEOUS VELOCITY AND CONCENTRATION MEASUREMENTS OF A TURBULENT JET MIXING FLOW

EHD flow produced by positive and negative point-to-plate corona discharges

ULTRASONIC INSPECTION, MATERIAL NOISE AND. Mehmet Bilgen and James H. Center for NDE Iowa State University Ames, IA 50011

Microwave-induced thermoacoustic tomography using multi-sector scanning

Structure of Biological Materials

Elec Eng 3BA3: Structure of Biological Materials

Non-invasive measurement of blood hematocrit in artery

CFD MODELLING OF THE ACOUSTIC STREAMING INDUCED BY AN ULTRASONIC HORN REACTOR

A PIV Algorithm for Estimating Time-Averaged Velocity Fields

PIV Visualization of Acoustic Streaming in Non-Newtonian Fluid

Measuring vibration characteristics at large amplitude region of materials for high power ultrasonic vibration system

TURBULENCE IN MICRO-CHANNELS

PD233: Design of Biomedical Devices and Systems

ESTIMATION OF LAYER THICKNESS BY THE COST FUNCTION OPTIMIZATION: PHANTOM STUDY

18th International Symposium on the Application of Laser and Imaging Techniques to Fluid Mechanics LISBON PORTUGAL JULY 4 7, 2016.

Imaging of vibrating objects using speckle subtraction

Journal of Fluid Science and Technology

Modelling I. The Need for New Formulas Calculating Near Field, Lateral Resolution and Depth of Field D. Braconnier, E. Carcreff, KJTD, Japan

Disruptive shear stress measurements of fibre suspension using ultrasound Doppler techniques

On the correlation of the acoustic signal of microphones mounted on a flat plate to the turbulence of an impinging jet

STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI

Ultrasonic Measurement of Minute Displacement of Object Cyclically Actuated by Acoustic Radiation Force

DEVELOPMENT OF NANO PARTICLE SIZING SYSTEM USING FLUORESCENCE POLARIZATION

Experimental analysis of natural convection with Joule heating by means of particle image velocimetry

Velocity Measurement of Blood Flow in a Microtube Using Micro PIV System

Installation effects on an ultrasonic flow meter with implications for self diagnostics

THE EFFECT OF SAMPLE SIZE, TURBULENCE INTENSITY AND THE VELOCITY FIELD ON THE EXPERIMENTAL ACCURACY OF ENSEMBLE AVERAGED PIV MEASUREMENTS

Electrical Engineering 3BA3: Structure of Biological Materials

ActiPix SDI300 Surface Dissolution Imaging System

ULTRASONIC NDE RHEALOGICAL MEASUREMENT TOOLS FOR INDUSTRIAL PROCESS CONTROL

Applications in Biofluidics

Atmospheric Lidar The Atmospheric Lidar (ATLID) is a high-spectral resolution lidar and will be the first of its type to be flown in space.

Abstract. 1 Introduction

Design and Aerodynamic Characterization of a Synthetic Jet for Boundary Layer Control

TODAY A very brief introduction to measuring turbulent flows... To back up some techniques used in papers today...

Dynamics of Large Scale Motions in Bubble-Driven Turbulent Flow

FLOW VISUALIZATION OF FERROMAGNETIC NANO- PARTICLES ON MICROCHANNEL FLOW USING DARK FIELD MICROSCOPY

Visualization of flow pattern over or around immersed objects in open channel flow.

D-D FUSION NEUTRONS FROM A STRONG SPHERICAL SHOCK WAVE FOCUSED ON A DEUTERIUM BUBBLE IN WATER. Dr. Michel Laberge General Fusion Inc.

White Paper FINAL REPORT AN EVALUATION OF THE HYDRODYNAMICS MECHANISMS WHICH DRIVE THE PERFORMANCE OF THE WESTFALL STATIC MIXER.

Ultrasonic Flow Metering Errors due to Pulsating Flow

Time-resolved photoacoustics for glucose concentration measurement: theory and experiment

Angular Spectrum Decomposition Analysis of Second Harmonic Ultrasound Propagation and its Relation to Tissue Harmonic Imaging

Workshop 2: Acoustic Output Measurements

The Physics of Doppler Ultrasound. HET408 Medical Imaging

ANALYSIS OF TURBULENT FLOW IN THE IMPELLER OF A CHEMICAL PUMP

BNG/ECE 487 FINAL (W16)

ANALYSIS OF FREQUENCY CHARACTERISTICS ON NON-INVASIVE ULTRASONIC-DOPPLER FLOW MEASUREMENT FOR METAL PIPES

Today s menu. Last lecture. A/D conversion. A/D conversion (cont d...) Sampling

Georgia Institute of Technology. Nonlinear Dynamics & Chaos Physics 4267/6268. Faraday Waves. One Dimensional Study

NUMERICAL MODELING OF TRANSIENT ACOUSTIC FIELD USING FINITE ELEMENT METHOD

Quantitative Measurement of planar Droplet Sauter Mean Diameter in sprays using Planar Droplet Sizing

Medical Imaging Physics Spring Quarter Week 3-2

Lesson 05: Intensity Measurements and Bioeffects. This lesson contains 18 slides plus 6 multiple-choice questions.

EL-GY 6813/BE-GY 6203 Medical Imaging, Fall 2016 Final Exam

Colloquium FLUID DYNAMICS 2013 Institute of Thermomechanics AS CR, v.v.i., Prague, October 23-25, 2013 p.1

Investigation of irregularity of flow distribution across the tube bundle in shell-and-tube heat exchanger with segmental baffles using PIV method

Optodynamic Characterization of Laser-Induced Bubbles

Technical University of Denmark

Experiments on the perturbation of a channel flow by a triangular ripple

Counter-Current Shear Layer Vortex Generation Facility

Noncontact measurement technique for wide range of viscosity of µl-order liquid sample

Observations of Giant Bursts Associated with Microscale Breaking Waves

AE Source Orientation by Plate Wave Analysis * Michael R. Gorman Aeronautics and Astronautics Naval Postgraduate School Monterey, CA 93943

Regular article Phase change problems with free convection: fixed grid numerical simulation

First observations of the second solar spectrum with spatial resolution at the Lunette Jean Rösch

Chapter 33: ELECTROMAGNETIC WAVES 559

Supplementary Informations Spatial cooperativity in soft glassy flows

Sound wave bends as it hits an interface at an oblique angle. 4. Reflection. Sound wave bounces back to probe

Visualization of ultrasonic cavitation in visible and IR spectra

Velocity and temperature measurements in a large-scale Rayleigh-Bénard experiment using LDA and micro thermistors

Measurements of rotational transform due to noninductive toroidal current using motional Stark effect spectroscopy in the Large Helical Device

PIV Measurements of the Influence of Seeding Particles Concentration on the Velocity of an EHD Flow

Mandatory Assignment 2013 INF-GEO4310

Experimental Setup. Flow Direction Leading Edge. Field of View (25 25 mm) Trailing Edge. Cavity Wall. H=30.0 mm. L=38.1 mm

The Scattering of Light by Small Particles. Advanced Laboratory, Physics 407 University of Wisconsin Madison, Wisconsin 53706

2D TIME AVERAGED FLOW MAPPING OF DIE ENTRY IN FLOW OF HIGHLY CONCENTRATED SHEAR-THINNING AND SHEAR-THICKENING SUSPENSIONS

MEASUREMENT OF LOCAL POROSITY OF PARTICLES REINFORCED COMPOSITES WITH THE LASER OPTOACOUSTIC METHOD

Measurement of the optical absorption coefficient of a liquid by use of a time-resolved photoacoustic technique

Generated Flow in Fluid Medium by Focused Ultrasound: Acoustic Streaming PIV Measurements

31545 Medical Imaging systems

A FEM STUDY ON THE INFLUENCE OF THE GEOMETRIC CHARACTERISTICS OF METALLIC FILMS IRRADIATED BY NANOSECOND LASER PULSES

Measurement of Elastic Constants Using Ultrasound

Transcription:

European Journal of Ultrasound 7 (1998) 73 81 Scientific paper Estimation of acoustical streaming: theoretical model, Doppler measurements and optical visualisation Andrzej Nowicki *, Tomasz Kowalewski, Wojciech Secomski, Janusz Wójcik Institute of Fundamental Technological Research, Polish Academy of Sciences, Swietokrzyska 21, 00-049 Warsaw, Poland Abstract An approximate solution for the streaming velocity generated by flat and weakly focused transducers was derived by directly solving the Dirichlet boundary conditions for the Poisson equation, the solution of the Navier-Stokes equation for the axial components of the streaming velocity. The theoretical model was verified experimentally using a 32 MHz pulsed Doppler unit. The experimental acoustical fields were produced by three different 4 mm diameter flat and focused transducers driven by the transmitter generating the average acoustic power within the range from 1 W to 6 mw. The streaming velocity was measured along the ultrasonic beam from 0 to 2 cm. Streaming was induced in a solution of water and corn starch. The experimental results showed that for a given acoustic power the streaming velocity was independent of the starch density in water, changed from 0.3 to 40 grams of starch in 1lof distilled water. For applied acoustic powers, the streaming velocity changed linearly from 0.2 to 40 mm/s. Both, the theoretical solutions for plane and focused waves and the experimental results were in good agreement. The streaming velocity field was also visualised using the particle image velocimetry (PIV) and two different evaluation methods. The first based on the FFT-based cross-correlation analysis between small sections for each pair of images and the second employing the algorithm of searching for local displacements between several images. 1998 Elsevier Science Ireland Ltd. All rights reserved. Keywords: Doppler; Acoustical streaming; Velocity; Particle image velocimetry 1. Introduction The acoustic waves which propagate in liquids obey the general laws of hydrodynamics. In a * Corresponding author. Tel.: +48 22 8269841; fax: +48 22 8269815; e-mail: anowicki@ippt.gov.pl linear medium the dependence between the pressure and the particle velocity is linear; in other words, the acoustic impedance is constant. In a non-linear medium, the impedance varies in time and the acoustic pressure has a constant component and by analogy to electric systems, it may be said that a non-linear medium acts like a pressure 0929-8266/98/$19.00 1998 Elsevier Science Ireland Ltd. All rights reserved. PII S0929-8266(98)00020-2

74 A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 rectifier. Waves with finite amplitudes are accompanied by such events as the radiation pressure and streaming. 2. Theory Nyborg (1965) solved the Navier-Stokes equation with an accuracy up to the second order approximations. Wu and Du (1993) developed the theory of deriving the approximate solution to the Nyborg equation. Adopting relevant assumptions, the authors obtained the Poisson equation as a description of the component 2z of the vector =[ 2r, 2z ] of the streaming velocity: 2 2z = 1 I z c z = 2 c I z (1) where is the absorption coefficient, c, the wave propagation velocity in the medium,, the shear viscosity coefficient, and I z, the acoustic intensity along the axis. Although Wu and Du (1993) undertook to solve Eq. (1) from the beginning, we have applied the general solution including the relevant Dirichlet conditions for the equation of this type. For the case of a bounded plane wave with a circular section, perpendicular to the propagation axis z, with the radius a, and for a Gaussian beam generated by a circular transducer with the radius a, the following solutions were obtained for the component 2z (x, y, z) of the Fig. 1. Block diagram of the Doppler measurement set-up. vector of the streaming velocity along the beam axis (x=0, y=0). (1) Linear (bounded) plane wave 2z (0, 0, z)= I 0a 2 c 0 e 2 as 1+ z a s 2 1+ z a +s 2+ z a +s z a s n ds (3) where z is the propagation axis, a, the radius of a transducer,, the absorption coefficient, c, the wave propagation velocity in the medium,, the shear viscosity coefficient, and I 0, the acoustic intensity at the transducer face. (2) A weakly focused beam with a Gaussian intensity distribution Fig. 2. Streaming velocity in function of the radiated acoustic power; plane 32 MHz transducer (Nowicki et al., 1997).

A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 75 Fig. 3. Doppler spectrum of the streaming velocity measured at the depth of 0.6 mm for plane beam. Fig. 4. Streaming velocity vs. distance, plane 32 MHz transducer. The radius of the transducer is equal to 4 mm. The solid line, theoretical calculations, points, experimental results (Nowicki et al., 1997). 2z (0, 0, z)= 1 I 0 a 2 2 2 cb e (2A(z )/a2 )(z z ) 2 erfc 2A(z ) a e (2A(z )/a2 )(z+z ) 2 erfc 2A(z ) a where 0 A(z ) e 2 z (z z ) n (z+z ) nn dz (4) BRF(R) A(z) z F(R)) 2 +C(R), F(R) r 2 0R r 2 0+(BR), 2 C(R) F(R)[R F(R)], R is the geometrical focal length of the acoustic lens, F(R) is the physical focal length (the position of the maximum of the field intensity distribution), r 0 =(1/2)ka 2, B is a constant related to the Gaussian beam and equals one on the transducer surface (z=0). In their computer calculations the authors used the numerical approximation of the function erfc(x) (Abramowitz and Stegun, 1968): erfc(x)=efc(x) e x2 + (x), (x) 1.5 10 7, 5 efc(x) p n f(x) n, f(x)= 1 (5) n=1 1+px p=0.3275911, p 1 =0.254829592, p 2 = 0.284496736, p 3 =1.421413741, p 4 = 1.453152027, and p 5 =1.0614005429.

76 A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 Fig. 5. Streaming vs. distance; focused transducers, focal distance=8 and 12 mm, radius of the transducer is equal to 4 mm. The solid line, theoretical calculations, points, experimental results (Nowicki et al., 1997). Substituting approximation (5) into (4), the following expression, convenient for computer calculations is obtained. 2z (0, 0 z)= I 0a 2 2 cb 2A(z ) z z a z+z g 2 z A(z ) e efc n dz a (6) 0 n 2A(z )(z+z ) efc where z g depends in fact on z and the properties of the function A(z ) e 2 z. In our calculations for z 3R we adopted z g =3R. For z 4R it is sufficient to adopt z g R. For large z, but ones smaller than 1/, z g may be determined using the relation z+z g max[1/, 2R)]. It was assumed in the calculations that in water =2.53 10 16 f 2 Np/cm Hz 2 and =0.01 Poise. 3. Methods and results 3.1. Measuring system The streaming was measured using a Doppler ultrasound blood flowmeter. The transmitter generated a 32 MHz bursts, lasting 0.5 s with the repetition frequency equal to about 31 khz. The backscattered signal was received in a gate of 0.5 s duration and variable delay. The bandwidth of the receiver was extended from the DC up to 4 khz. The backscattered Doppler signal was analysed using the digital oscilloscope LeCroy 9450A including FFT spectrum analyser. Up to 100 successive Doppler spectra were averaged (frequency resolution was 0.1 1 Hz). Three different flat and focused (focused at depths of 8 and 12 mm) lithium niobate 4 mm diameter transducers were examined. The estimated power was about 1.4 mw for each of the three transducers. Fig. 1 3.2. Measurements Streaming was measured in a rectangular container filled with a corn starch suspension in distilled water. The system consisted of a Doppler flowmeter and an ultrasonic transducer working at 32 MHz, submerged in a container with water. The Doppler signal was analysed using the oscilloscope LeCroy 9450A with an FFT analysis module. The maximum flow velocity was determined as the maximum frequency below which 90% of the power of the Doppler signal lies. The streaming velocity increased linearly with the power transmitted in the range between 0.001 to 6 mw. The correlation coefficient was R=0.9992. (see Figs. 2 and 3). Fig. 4 shows the streaming velocity for a plane transducer. Fig. 5 shows the streaming velocities for transducers focused at 8 and 12 mm depths, respectively. The flow velocity changes were measured for different densities of the starch suspension in water. It was found that for densities between 0.3

A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 77 Fig. 6. Visualisation of acoustic streaming, ten superimposed images taken at 200 ms interval. (a) Plane wave transducer, (b) focused transducer. and 40 g/l the streaming velocity hardly varied. The maximum deviation from the mean value was 5.3%. The S.D./mean ratio=0.07. For a higher starch concentration than 40 g/l, the streaming velocity fell; it was probably caused by higher viscosity of the suspension. 4. Flow visualisation and measurement of the velocity field An experimental set-up used for measurements consisted of a 64 64 90 mm rectangular box, special constructed halogen tube illumination, and a CCD video camera. As a flow medium distilled water and two aqueous solutions of glycerine (40 and 80% per vol.) were used. The flow was seeded with a very dilute (below 0.1%) fine pine pollen powder. The cavity walls were made of glass with the top side left opened. Ultrasonic transducers used were immersed at the centre of the top surface, approximately 4 mm deep into the liquid. Two 32 MHz transducers generating the plane and focused beams (12 mm focal distance) were used. The flow was observed at the vertical cross sections of the cavity using a light sheet technique. The flow images of 768 512 pixels were acquired by an 8-bit frame grabber (VFG-ITI). Transient development of the flow was recorded using short series of images acquired every 30 60 s and stored on the hard disk of the computer for later evaluation. The 2-D velocity vector distribution was measured by particle image velocimetry (PIV). By this method, the motion of the scattering particles observed in the plane of the illuminating light sheet can be analysed. Each of the images shows a relatively dense cloud of single illuminated parti-

78 A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 Fig. 6. (Continued) cles. A sequence of two or more separately captured digital images taken at a constant time interval (typically 200 ms) were used to evaluate the magnitude and direction of the velocity vectors. Two evaluation methods were used. The first one is based on the FFT-based cross-correlation analysis between small sections (interrogation windows) performed for each pair of images (Hiller et al., 1993). The average particle displacement during given time interval determines the velocity vector representing analysed section. By moving step by step interrogation widow across the image about 1000 vectors per one pair of images were obtained. The spatial resolution of the method is limited by minimum amount of tracers to be present in the interrogation window. In practice, the minimum window size was 32 32 pixels. The second method, recently developed DP-PIV optical flow based technique, searches for local displacements between several images (Quenot et al., 1997). It allowed to improve accuracy and to obtain dense velocity field (displacement vector for each image pixel). Several images recorded periodically within a given time interval were added in the computer memory in order to obtain a general view of the flow pattern. Displayed images are similar to the multiexposed photographs, showing the flow direction and its structure (Fig. 6). The generated flow is strongly 3-D but only its central cross-section was recorded. Observed asymmetry of the flow pattern indicates effects of the third velocity component, shifting the main flow stream out of the symmetry plane. The acoustic field radiating from the transducer generated flow in the cavity. This was observed for the pure water and 40% glycerol solution. For highly viscous 80% glycerol the effect of the acoustic field was invisible. The onset of the flow was recorded. After switching the power on, al-

A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 79 Fig. 7. Measured velocity field in the centre cross-section by DP-PIV method; only every 16th vector displayed. (a) Plane beam, horizontal size 62 mm, (b) focused beam, horizontal size 53 mm. most uniform flow stream along the axis of the transducer was observed. The flow originated from the transducer, pointing down into the cavity bottom. Subsequent flow interaction with the side walls and the liquid surface induced reverse flow, transporting liquid back to the surface. Finally complex interaction of the main flow stream with the reverse flow established an regular flow pattern, with the characteristic doublevortex structure. Typical transition time was about 3 min for water as a flow medium. A different flow pattern was observed for the 40% glycerine solution. For this case, it took up to about 5 min after switching the acoustic field on before a steady circulation was established in the near transducer region (about 15 mm below the transducer face), where the spiralling motion transported liquid down along the transducers axis and back to the surface. The maximum flow velocity was about 2 mm/s. This circulation induced very slow secondary recirculation in the cavity. The effect of the acoustic field characteristic was investigated replacing plane beam transducer with the focused one. The flow patter for both cases differed mainly in details. Its main feature exhibits the main portion of the fast flow streaming pointing down. The example of the velocity profiles extracted along the transducer axis and perpendicularly to it illustrate main differences in flow characteristics (Figs. 7 and 8). 5. Conclusions The streaming velocities generated by plane and weakly focused ultrasonic heads were calculated. The measured velocity changes as a function of depth confirm well the theoretical calculations for all the three heads. Good quantitative agreement was obtained between the measured streaming velocities and those calculated theoretically. The latter were modified with respect to the solution of the Poisson equation given earlier by Wu and Du. The slight differences are probably caused by the inaccuracy of estimation of the maximum Doppler frequency and the impossibility of accurate measurement of the real acoustic power radiated by transducers in the high frequency range. The measurements for the frequency of 32 MHz indicated a linear dependence of the streaming velocity on the acoustic power. It may be assumed that the addition of starch did not affect the streaming velocity measurements for no changes were found in the measured velocities with percentage variations of the starch content in the suspension. Given the measurement repeatability and accuracy it may be hoped that in the future the streaming velocity measurement can be applied in evaluating the acoustic power radiated by a transducer. This method may be used to measure

80 A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 Fig. 8. Velocity profiles extracted from the PIV measurements. (a) Vertical velocity component along transducer axis, distance measured from the transducer external surface, (b) vertical velocity component along horizontal line, passing maximum value (approximately 17 mm from the plane transducer and 13 mm from the focused one).

A. Nowicki et al. / European Journal of Ultrasound 7 (1998) 73 81 81 the acoustic power of ultrasonographic probes meant for medical diagnostics. The digital flow images demonstrated the main 2-D characteristics of the acoustic steaming generated for the plane and focused beam. The PIV and DP-PIV evaluation of the flow images gave us full plane velocity vector fields, allowing quantitative analysis of the observed flow. The quantitative results obtained with PIV are not to be directly compared to the ones measured with Doppler. The acoustic intensities used for PIV were not calibrated as the visualisation was intended to be to be the pilot study enhancing the understanding of the streaming phenomena associated with the fluid flow generated by the acoustic radiation force References Abramowitz M, Stegun IA, editors. Handbook of Mathematical Functions. New York: Dover, 1968. Hiller WJ, Koch St, Kowalewski TA, Stella F. Onset of natural convection in a cube. Int J Heat Mass Transf 1993;36:3251 63. Nowicki A, Secomski W, Wójcik J. Acoustic streaming: comparison of low amplitude linear model with streaming velocities measured by means of 32 MHz Doppler. Ultrasound Med. Biol. 1997;23(5):783 91. Nyborg WL. Acoustic streaming. In: Mason WP, editor. Physical Acoustics, IIB. New York: Academic Press, 1965:265 331. Quenot G, Pakleza J, Kowalewski TA. Particle Image Velocimetry with Optical Flow (submitted). Wu J, Du G. Acoustic streaming generated by focused Gaussian beam and finite amplitude toneburst. Ultrasound Med. Biol. 1993;19(2):167 76...