Hardware Installation & Troubleshooting Guide. Tofino Industrial Security Solution Version 1.0.0

Similar documents
OH BOY! Story. N a r r a t iv e a n d o bj e c t s th ea t e r Fo r a l l a g e s, fr o m th e a ge of 9

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Overload Relays. SIRIUS 3RU1 Thermal Overload Relays. 3RU11 for standard applications. 5/46 Siemens LV 1 AO 2011

ISSP User Guide CY3207ISSP. Revision C

SC125MS. Data Sheet and Instruction Manual. ! Warning! Salem Controls Inc. Stepper Motor Driver. Last Updated 12/14/2004

Installation guide 862 MIT / MIR

WeatherHub2 Quick Start Guide

Assembly and Operation Manual. April 2016

PHOENIX CONTACT - 04/2016. Features

A L A BA M A L A W R E V IE W

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Instruction Sheet COOL SERIES DUCT COOL LISTED H NK O. PR D C FE - Re ove r fro e c sed rea. I Page 1 Rev A

I zm ir I nstiute of Technology CS Lecture Notes are based on the CS 101 notes at the University of I llinois at Urbana-Cham paign

5SJ4...-.HG Circuit Breakers to IEC and UL 489

QUANTUM CONCEPT. Swimming User s Manual

T h e C S E T I P r o j e c t

16 Input AC Block I/O Module

xlogic SuperRelay is a compact and expandable CPU replacing mini PLCs, multiple timers, relays and counters.

Microcare LCD Solar MPPT User Documentation

Single point load cells

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR 19 TECHNOLOGY. NET Protector Surge Arrester. Protects switches, HUBs and telecommunication

32 Input AC Block I/O Module

MODEL: R7K4FML3. Remote I/O R7K4F Series. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.)

TC7WB66CFK,TC7WB66CL8X TC7WB67CFK,TC7WB67CL8X

ED 701 General Industry Pressure Transmitter

Fog Monitor 100 (FM 100) Extinction Module. Operator Manual

Overlay Transport Virtualization (OTV) Unicast-Mode Transport Infrastructure Deployment

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Thermal-Magnetic Circuit Breaker 2210-S2..

Table of C on t en t s Global Campus 21 in N umbe r s R e g ional Capac it y D e v e lopme nt in E-L e ar ning Structure a n d C o m p o n en ts R ea

P a g e 5 1 of R e p o r t P B 4 / 0 9

Training Guide. Coastal Environmental Systems, Inc.

Thermal-Magnetic Circuit Breaker 2210-S2..

SuperCELL Data Programmer and ACTiSys IR Programmer User s Guide

What are S M U s? SMU = Software Maintenance Upgrade Software patch del iv ery u nit wh ich once ins tal l ed and activ ated prov ides a point-fix for

ANNEX to IECEx Certificate

Esterification in a PFR with Aspen Plus V8.0

MPP5800 series - PANEL MOUNT PRINTERS. Options

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

Installation and Operation Manual. AllSync Plus Wired Clocks

Thermal-Magnetic Circuit Breaker 2210-S2..

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

O P E R A T I N G M A N U A L

Page 1 of 16 Issue No. 0 of IECEx TUN X

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Orbit Support Pack for Excel. user manual

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type SSM6N15FE

Assembly Instructions for the 1-Wire Weather Station V2.0/V3.0

Ultra-Small Footprint N-Channel FemtoFET MOSFET Test EVM

AN78xx/AN78xxF Series

Model M3484 Industrial Line Noise Filter Module Customer Reference Manual

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

What You Need to Get Started INSTALLATION GUIDE

Product Data Sheet KyoRack 2

Imformation of C091D series

Small Absolute Pressure Sensor

Panel Mount, Single Phase 120 and 240 Volt Fixed Shaft (click blue text for more details)

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Multi-function, economical instrument with 4 functions in the same casing. Accessibility and safety: large-dimension terminals Insulated circuits

SM6-36. adaptation instructions. fuse blowing electrical. English. distribution HTA

Small Gage Pressure Sensor

2.9. Namur Valves 2.9. page 175. Namur 1/4 also called Namur 1 in accordance to VDI / VDE Namur 1/2 also called Namur 2.

Small, Gauge Pressure Sensor

ABLIC Inc., Rev.2.2_02

TF 202 / TF 202-Ex. Field mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

In-System Serial Programming (ISSP) Guide

SINEAX VK 636 Programmable Temperature Transmitter with PROFIBUS-PA protocol

AN78Lxx/AN78LxxM Series

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type SSM6N44FE. DC I D 100 ma Pulse I DP 200

Pascal ET is an handheld multifunction calibrator for the measurement and simulation of the following parameters: - pressure

PCAN-MicroMod Evaluation Kit. Test and Development Environment for the PCAN-MicroMod. User Manual

User s Manual: MODEL 904-T CLINOMETER PAK

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

The Ordering Code for various standard model Recorders with an AC supply and without any additional options are as follows:

TC4028BP, TC4028BF TC4028BP/BF. TC4028B BCD-to-Decimal Decoder. Pin Assignment TOSHIBA CMOS Digital Integrated Circuit Silicon Monolithic

Remote Display Unit. Installers Handbook Copyright 2001 AirSense Technology Ltd. LM Remote Display Unit Installers Handbook Issue 1.

HMS-5000 Manual. Product Name: HMS-5000 Hall Effect Measurement System with variable temperature from 80K to 350K. - Manual version: ver 5.

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

TOSHIBA Field Effect Transistor Silicon N Channel MOS Type SSM6N37FU

In-System Serial Programming (ISSP) Guide

WE RE HERE TO HELP: 1 (844) LIGHTCLOUD

INSTALLATION INSTRUCTIONS ATV SNOW PLOW Mounting Kit: PN Application: HONDA 300

Tie Bar Extension Measuring Chain

BEFORE USE... POINTS OF CAUTION COMPONENT IDENTIFICATION INSTRUCTION MANUAL MODEL R7K4DH-1-DAC32D R7K4DH-1-DAC32D

400 Volts, 50HZ 480 Volts, 60HZ 600 Volts, 60HZ TECHNICAL REFERENCE MANUAL

E2T0 DVP

COMMON BLACK IRON & BLADE PARTS

Pressure Transmitter ED 701

Operator manual. Simrad ITI Trawl instrumentation system

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

TF 212 / TF 212-Ex. Field mounted temperature transmitter, Profibus PA, Pt 100 (RTD), thermocouples, 1 or 2 independent channels. ABB Instrumentation

PLAY OFF 48" FOOSBALL TABLE ASSEM BLY I NSTRU CTI ONS

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

In-System Serial Programming (ISSP) Guide

Power Distribution System SVS04

INSTALLATION INSTRUCTIONS ATV Plow Blade Part Number: (50 ), (54 ), or (60 ) Application: All Terrain Vehicles

Product Data Sheet KyoRack 4

Transcription:

Hardware Installation & Troubleshooting Guide Tofino Industrial Security Solution Version 1.0.0

Copyright Information By res Security Inc While this information is presented in good faith and believ ed to be accurate, By res Security Inc. disclaims the implied warranties of merchantability and fitness for a particular purpose and makes no ex press warranties ex cept as may be stated in its written agreement with and for its customers. In no ev ent is By res Security Inc. liable to any one for any indirect, special or consequential damages. The information and specifications in this document are subject to change without notice. Tofino, Tofino Industrial Security Solution and Tofino Intrinsically Secure are trademarks of By res Security Inc. Other brand or product names are trademarks of their respectiv e owners. While ev ery precaution has been taken in the preparation of this document, the publisher and the author assume no responsibility for errors or omissions, or for damages resulting from the use of information contained in this document or from the use of programs and source code that may accompany it. In no ev ent shall the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to hav e been caused directly or indirectly by this document. i

Table of Contents Part I Introduction 1 Part II Installation Guide 1 Part III Troubleshooting 7 3.1 Tofino Security Appliance (SA) LED Indications 8 3.2 Control System/Network Communications 9 3.3 Tofino CMP to Tofino SA Communications Part IV Certification 10 11 4.1 Europe 11 4.2 USA 11 4.3 Canada 12 Part V Technical Support 13 ii

1 Introduction This inline Tofino SA Ethernet appliance can be used to protect HMI, DCS, PLC or RTU control dev ices, as clusters, or as indiv idual dev ices. The Tofino Industrial Security Sy stem consists of two additional core components not cov ered by this manual: The Central Management Platform (CMP) - a Windows-based management sy stem and database for centralized monitoring and configuration of each Tofino SA, regardless of its phy sical location in the company network. Loadable Security Modules (LSM) - a v ariety of software plug-ins prov iding security serv ices such as firewalls, intrusion detection sy stems (IDS) and v irtual priv ate network (V PN) encry ption. One, or more, LSMs can be downloaded into a Tofino SA, to prov ide a customized security function to suit the requirements of the control sy stem. LSMs require an activ ated software license. For information about LSM license activ ation, consult the Tofino CMP help or the Tofino CMP User's Manual. 2 Installation Guide Unpacking Unpack the appliance and check it for damage. Do not use any parts that show ev idence of damage. Preparation To install the Tofino SA y ou will need: 1. A 3mm straight blade screwdriv er 2. 9...32V DC supply with 350mA current (@24V ) per appliance. A second (i. 1

e. redundant) supply is optional. (Note: 22V DC minimum is required for 1 8V power fail detection option.) 3. Wire for DC power & power-fail connections 4. Two 1 0/1 00 base-t cables, preferably screened, to connect the Tofino SA between the network and the equipment being protected. 5. A suitable 35mm DIN rail location to mount the appliance (optional - see mounting details). 2

Mounting the Appliance At the back of the appliance, push out the mounting clips - top and bottom. Press the appliance firmly onto the DIN rail and push mounting clips back in. Check that the appliance grips the rail securely. Note: An alternativ e fix ing method is to use M4 screws through the holes in the clips (1 52mm between centres - see diagram) for mounting the appliance to a panel. Record the T ofino ID num ber (see label) & the installation location for future reference 3

Wiring for DC Power (see diagrams) Note: These two plugs use cage-clamp screw terminals to accept a stripped wire, ranging in size from 24 to 1 2 AWG (0.2 2.5mm2) One or two DC power supplies may be connected to the Tofino SA utilizing the four-position connector plug (5 8) at the bottom of the Tofino SA appliance. Two power supplies will not share the current; the higher v oltage supply will take the load. Power fail signals from the supplies may be used by connecting them to the connector plug (pins 1 & 2) at the top of the appliance - ground returns should go to pin 3. Connection Diagram Power On - Appliance Startup Do not connect the T ofino SA into the network at this stage. The appliance will not pass any network traffic until it has ex ecuted its startup sequence. At power ON, all four LED indicators are lit and the appliance will commence its startup sequence. At the end of the startup sequence, (i.e. after approx. 1 minute) the Pow er LED will remain ON, but the Fault, Event and Mode LED indicators will all be ex tinguished to show the sequence is complete. 4

Network Connection Note: The appliance must hav e completed its startup before any network connections are made. 1. Connect an RJ45 patch cable from the network switch/router to the Unsecured Tofino SA port ( ). 2. Connect an RJ45 patch cable from the Secure Tofino SA port ( network port of the equipment being protected. ) to the 3. Check that the y ellow Link activ ity light is flashing on both of the network sockets to show network traffic. The green Speed light will come on if the link is operating at 1 00Mb/s. IMPORTANT: An unconfigured Tofino SA will pass all network traffic and will not prov ide any security. Check with y our network administrator to find out if the Tofino SA is pre-configured, or read the Tofino CMP User's Manual for information on how to configure the appliance and thus make it secure. USB Load/Save Loading New Configuration or Firmware The USB Load function loads files containing firmware or configuration updates from a USB storage dev ice. Note: Only v ersion 2.0 USB storage dev ices are supported. 1. Ensure the Tofino SA has been powered for at least one minute. 2. Insert the USB storage dev ice containing the prepared files into one of its USB ports. 3. Press and hold the Config button for 5-6 seconds until the Mode-Ev entfault LEDs begin to flash, in an upward sequence, to indicate a Load. 4. When the flashing sequence stops (but not before) remov e the USB storage dev ice. 5. If the load was successful, the Tofino SA will go to OPERATIONAL mode, with the Mode LED showing a steady light. Saving Diagnostic Information The USB Sav e function copies diagnostic files from the Tofino SA to the USB storage dev ice. These files can then be sent to technical support for analy sis. 1. Insert a USB storage dev ice into one of the USB ports. 2. Press and hold the Config button for 1-2 (but less than 5) seconds 3. The Fault-Ev ent-mode LEDs will begin to flash, in downward sequence, to indicate a Sav e. 4. When the flashing sequence stops remov e the USB storage dev ice 5. If the sav e was successful the Tofino SA LEDs will rev ert to the state they were in prior to the sav ing action. 6. Send copies of these files to technical support for analy sis. 5

The Fault LED will flash a number of times if a fault occurs with USB Configuration Loading or Diagnostic Sav ing. Use Table 1 to diagnose the fault from the number of Fault LED flashes, and to decide the appropriate course of action. Table 1 Fault LED Activity During Load/Save No. of Flashes During Load Sequence The USB ports are disabled. At the CMP console, check the General /Communications settings for the particular Tofino. Confirm the USB Load Config setting is Enabled and apply the configuration. During Save Sequence 2 No USB storage dev ice in the USB port or the USB storage dev ice is not formatted with the standard Fat32 format. No USB storage dev ice in the USB port or the USB storage dev ice is not formatted with the standard Fat32 format. 3 The files on the USB storage dev ice are not v alid. The Tofino SA was unable to create the diagnostics files. Contact technical support. 4 The Tofino SA was unable to The Tofino SA was unable to encry pt the decry pt the configuration files. diagnostic files. Contact technical The files may hav e been support. corrupted during the transfer process onto the USB storage dev ice. Please try transferring them again. If this second transfer attempt is unsuccessful, then please contact technical support. 5 The Tofino SA was unable to load The Tofino SA was unable to copy the files. The files may hav e been the encry pted diagnostics files to corrupted during the transfer the USB storage dev ice. The USB process onto the USB storage storage dev ice may be full. dev ice. Please try transferring them again. If this second transfer attempt is unsuccessful, then please contact technical support. 6 The Tofino SA was unable to shut The Tofino SA was unable to shut down the USB port. Contact down the USB port. Contact technical support. technical support. 1 N/A 6

3 Troubleshooting The Tofino SA is prov ided with LEDs to indicate normal and other modes of operation. Use Table 2 for assistance in interpreting the LED display s. Table 3 and Table 4 offer further assistance in identify ing and solv ing any possible communication malfunctions. 7

3.1 Tofino Security Appliance (SA) LED Indications Table 2 Sym ptom Pos s ible Caus e Solution Pow er LED: Off T ofin o SA does n ot h a v e pow er En su r e t h e T ofin o SA h a s 9-3 2 V DC pow er con n ect ed Fa u lt LED: On Solid T ofin o SA h a s det ect ed a h a r dw a r e fa u lt a n d did n ot st a r t Rem ov e T ofin o SA fr om n et w or k a n d con t a ct t ech n ica l su ppor t Fa u lt LED: Lon g Fla sh (2 secon ds) T ofin o SA oper a t in g sy st em did n ot st a r t pr oper ly Rem ov e T ofin o SA fr om n et w or k a n d con t a ct t ech n ica l su ppor t Fa u lt LED: Sh or t Fla sh (0.5 secon ds) A T ofin o LSM ser v ice did n ot st a r t Upda t e a ll LSMs u sin g t h e T ofin o CMP, T ofin o LSM Upda t e W iza r d. If t h is does n ot solv e t h e pr oblem, r em ov e t h e T ofin o SA fr om t h e n et w or k a n d con t a ct t ech n ica l su ppor t Ev en t LED: On or Fla sh in g T ofin o SA is defen din g t h e Det er m in e t h e sou r ce of t h e a t t a ck u sin g n et w or k fr om a t t a ck t h e T ofin o CMP Ev en t V iew Dev ice h a s been a dded t o t h e n et w or k t h a t is n ot r eg ist er ed in t h e T ofin o CMP da t a ba se A dd a n ode t o t h e n et w or k dia g r a m on t h e T ofin o CMP u sin g t h e Net w or k Edit or. Cr ea t e a fir ew a ll r u le t o h a n dle t r a ffic a s n eeded (See: T ofin o CMP Fir ew a ll Ru le Con fig u r a t ion in t h e Tofino CMP Us er's Guide) Dev ice on t h e n et w or k is g en er a t in g br oa dca st t r a ffic Cr ea t e fir ew a ll r u les t o h a n dle br oa dca st t r a ffic a s n eeded. (See: T ofin o CMP Fir ew a ll Ru le Con fig u r a t ion in t h e Tofino CMP Us er's Guide) Mode LED: Off T ofin o SA is in See: T ofin o SA Modes in t h e Tofino CMP PREDEPLOY ED, PA SSIV E, Us er's Guide or DECOMMISSIONED m ode Mode LED: Lon g Fla sh (2 secon ds) T ofin o SA is in T EST m ode See: T ofin o SA Modes in t h e Tofino CMP Us er's Guide Mode LED Sh or t Fla sh T ofin o SA is in T EST FIELD-FORCE m ode See: T ofin o SA Modes in t h e Tofino CMP Us er's Guide. If a ppr opr ia t e, r et u r n t o OPERA T IONA L m ode by pr essin g t h e Mode bu t t on for 1 secon d Mode LED: On T ofin o SA is in OPERA T IONA L (pr ot ect ed) m ode No A ct ion is r equ ir ed Lin k /A ct iv it y LED (Y ellow ): Off Net w or k con n ect ion t o t h e Ch eck t h e Et h er n et ca blin g bet w een t h e T ofin o SA is m issin g T ofin o SA a n d t h e dev ices con n ect ed t o t h e T ofin o SA. Ch eck t h e Et h er n et Lin k LEDs on t h e dev ice con n ect ed t o t h e T ofin o SA (0.5 secon ds) 8

3.2 Control System/Network Communications Table 3 Sym ptom s Pos s ible Caus e Un a ble t o est a blish com m u n ica t ion s bet w een con t r ol sy st em equ ipm en t Net w or k con n ect ion t o t h e Con fir m t h a t bot h Et h er n et Lin k / T ofin o SA is m issin g A ct iv it y LEDs (Y ellow ) a r e on or fla sh in g. If n ot, ch eck a ll Et h er n et ca blin g bet w een t h e T ofin o SA a n d t h e ot h er n et w or k dev ices T ofin o SA Fir ew a ll LSM is block in g n et w or k t r a ffic t h a t n eeds t o be a llow ed Solution Sw it ch t h e T ofin o SA in t o T EST -FIELDFORCE m ode by pr essin g t h e Mode bu t t on for 1 secon d W h en t h e bu t t on is r elea sed, t h e Mode LED sh ou ld st a r t t o fla sh, in dica t in g t h a t a ll t r a ffic is a llow ed t o flow t h r ou g h t h e T ofin o SA Det er m in e w h a t t r a ffic is bein g block ed u sin g t h e Ev en t v iew on t h e T ofin o CMP Cr ea t e or a dju st fir ew a ll r u les t o a llow t r a ffic a s n eeded Ret u r n t h e T ofin o SA t o OPERA T IONA L m ode by pr essin g t h e Mode bu t t on on t h e T ofin o SA for 1 secon d T h e T ofin o SA is n ot block in g t r a ffic T ofin o SA is n ot in OPERA T IONA L m ode Con fir m t h a t t h e T ofin o SA Mode LED is on solid Fir ew a ll LSM is n ot in st a lled or is n ot a ct iv a t ed Ch eck t h e Modu les t a b of t h e T ofin o SA 's pr oper t ies pa g e on t h e T ofin o CMP Ru les in t h e T ofin o SA do Sy n ch r on ize t h e T ofin o SA w it h t h e n ot m a t ch t h e r u les sh ow n T ofin o CMP (See: Sy n ch r on izin g Y ou r on t h e T ofin o CMP T ofin o SA 's Con fig u r a t ion s in t h e Tofino CMP Us er's Manual) In cor r ect Allow r u le is a ct iv a t ed in t h e fir ew a ll Ch eck t h e fir ew a ll r u les on t h e Fir ew a ll pa g e of t h e T ofin o SA pr oper t ies pa g e on t h e T ofin o CMP 9

3.3 Tofino CMP to Tofino SA Communications Table 4 Sym ptom s Pos s ible Caus es Un a ble t o con n ect t o T h e T ofin o CMP a n d t h e t h e T ofin o SA fr om T ofin o SA do n ot h a v e a t h e T ofin o CMP clea r com m u n ica t ion s pa t h in t h e n et w or k Solutions En su r e t h a t T ofin o CMP ca n com m u n ica t e w it h a t lea st on e dev ice on t h e pr ot ect ed side of t h e T ofin o SA Not e: T est m a y r equ ir e t h e T ofin o SA t o be t em por a r ily sw it ch ed t o T EST -FIELDFORCE m ode by pr essin g t h e Mode bu t t on for 1 secon d Pr im a r y con t a ct dev ice is En su r e t h e pr im a r y con t a ct dev ice is set n ot set in t h e T ofin o CMP for t h e T ofin o SA (See: Edit in g t h e Pr oper t ies of a T ofin o SA in t h e Tofino CMP Us er's Manual) T h e T ofin o CMP does n ot h a v e t h e cor r ect IP a ddr ess for t h e pr im a r y a n d ba ck u p con t a ct dev ices En su r e t h e pr im a r y con t a ct dev ice is set for t h e T ofin o SA (See: Edit in g t h e Pr oper t ies of a T ofin o SA in t h e Tofino CMP Us er's Manual) Bot h pr im a r y or ba ck u p con t a ct dev ice is/a r e off t h e n et w or k En su r e t h e pr im a r y or ba ck u p con t a ct dev ice a r e pow er ed u p a n d on t h e n et w or k T h e T ofin o ID is m issin g or Con fir m t h e T ofin o ID on t h e fa ce of t h e in cor r ect on t h e T ofin o T ofin o SA is iden t ica l t o t h e ID en t er ed in CMP t h e T ofin o CMP (See: Edit in g t h e Pr oper t ies of a T ofin o SA in t h e Tofino CMP Us er's Manual) T h e T ofin o SA is a lr ea dy con fig u r ed t o con n ect t o a n ot h er T ofin o CMP For secu r it y r ea son s, a T ofin o SA ca n on ly con n ect t o on e T ofin o CMP. If n ecessa r y, fa ct or y r eset t h e T ofin o SA a n d r ea t t em pt con n ect ion 10

4 Certification 4.1 Europe Europe Authority MTL Standard EN 6007 95:2005 Approv ed For II 3G Ex na nc IIC T4-40 C< Ta < +7 0 C Certificate No. MTL07 A TEX921 1 X Conditions for safe use 1. The apparatus must be installed in an enclosure or an env ironment that prov ides a degree of protection not less than IP54 2. The module must not be inserted or remov ed unless either: a) the area in which the apparatus is installed is known to be non-hazardous, or b) the circuit to which it is connected has been de-energized 3. 4.2 The 9-32V supply that prov ides the input to the module must be deriv ed from a regulated power supply comply ing with the requirement USA USA Authority Standard FM FM 3600, FM 361 1 FM 381 0 Approv ed For N I/1 /2/A BCD/T4 Ta = 7 0 C Certificate No. 302991 4 1 /2/A Ex nc/iic/t4 Ta = 7 0 C Equipment Ratings: Nonincendiv e for Class I, Div ision 2, Groups A, B, C and D; Zone 2, AEx nc IIC T4 Ta = 7 0 C; in accordance with Control Drawings No. SCI-1 032, indoor hazardous (classified) locations. Conditions for safe use: 1. In Class I, Div ision 2 installations, the subject equipment shall be mounted within a tool-secured enclosure which is capable of accepting one or more of the Class I, Div ision 2 wiring methods specified in the National Electrical Code (ANSI/NFPA 7 0). 2. In ClassI, Zone 2 installations, the subject equipment shall be mounted within a tool-secured enclosure which is capable of accepting one or more of the Class I, Zone 2 wiring methods specified in the National Electrical Code (ANSI/ NFPA 7 0). Where installed in outdoor or potentially wet locations, the enclosure shall at a minimum, meet the requirements of IP54. Where installed in dry indoor locations, the enclosure shall, at minimum, meet the requirements of IP4X. 11

4.3 Canada Canada Authority Standard CA N /CSA E6007 9-0 FM CA N /CSA E6007 9-1 5 Approv ed For Certificate No. IPA /1 /2/A BCD/T4 Ta = 7 0 C 1 /2/Ex nl/iic/t4 Ta = 7 0 C 302991 4C C22.2 N o. 1 01 0-1 Equipment Ratings: Non-sparking for Class I, Div ision 2, Groups A, B, C and D; Zone 2, Ex nl IIC T4 Ta = 7 0 C; in accordance with Control Drawings No. SCI1 032, hazardous indoor locations. Conditions for safe use: 1. In Class I, Div ision 2 installations, the subject equipment shall be mounted within a tool-secured enclosure which is capable of accepting one or more of the Class I, Div ision 2 wiring methods specified in the Canadian Electrical Code (C22.2). 2. In Class I, Zone 2 installations, the subject equipment shall be mounted within a tool-secured enclosure which is capable of accepting one or more of the Class I, Zone 2 wiring methods specified in the Canadian Electrical Code (C22.1 ). Where installed in outdoor or potentially wet locations, the enclosure shall at a minimum, meet the requirements of IP54. Where installed in dry indoor locations, the enclosure shall, at minimum, meet the requirements of IP4X. 3. The user shall take necessary measures to ensure that the supply v oltage transients do not ex ceed 45V. 4. The user shall ensure that the field wiring insulation temperature is rated for 7 0 C. 5. The material used in the construction of the final enclosure, shall not contain, by mass, more than 7.5% magnesium. 6. It is the responsibility of the manufacturer to prov ide warning markings in French where required by local jurisdictions. 12

5 Technical Support Please contact the local representativ e in y our region. or e-mail: support@tofinosecurity.com web: www.tofinosecurity.com 13