Similar documents
E-LINEMK. Busbar Systems A.

DATA RACK BUSBAR. Data Rack Busbar Systems A.

MR medium rating busbar

VX25 Enclosure System. Technical documentation PE conductor connection, current carrying capacity

ZUCCHINI MR - MEDIUM RATING BUSBAR

BETA Protecting. Low-Voltage Fuse Systems. LV HRC fuse links. 3/36 Siemens ET B1 2008

Switches in conformity with ATEX directive

SPECIFICATION SS 51/9 400KV COUPLING CAPACITORS FOR POWER LINE CARRIER SYSTEM

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

2.12. Ex-Linear light fittings for fluorescent lamps - max. ambient temperature + 60 C - nllk W - 58 W for Zone 2 and 22

TECHNICAL INFORMATION

S R O T C U D IN & MYRRA

5SJ4...-.HG Circuit Breakers to IEC and UL 489

LD-LP-LL-LC Rope Safety Switches with reset for emergency stop

Various Busduct Assemblies: Various Busduct Assemblies: Various Busduct Assemblies:

Thermal-Magnetic Circuit Breaker 2210-S2..

INSULATORS INSULATORS

Thermal-Magnetic Circuit Breaker 2210-S2..

Universal limit switches

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2...

Thermal-Magnetic Circuit Breaker 2210-S2..

Tap Changer Type MHF III Specification, Assembly and Materials

GESELLSCHAFT FÜR ELEKTRISCHE HOCHLEISTUNGSPRÜFUNGEN Mitglied der Short-Circuit-Testing Liaison (STL) Test Report

Pressure transmitters for industrial applications MBS 32 and MBS 33

Thermal-Magnetic Circuit Breaker 2210-T2...

AC axial compact fan

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

VK2 volume flow controller Overview

TeSys circuit-breakers

16 Appendix 16 Electrical Research Association Report

4.3. Ex-Pendant light fittings AB 50 / SPG 1N / AB 51 / EVI 200 / EVI 500 / EV35 LED. (Zone 1, 2, 21, 22)

General characteristics

SWITCHGEAR: design concepts, testing, standards and safety of persons and installations

CDS. high density spring connection

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HAH1BVW S/08

AC axial compact fan

ZF Series Force Transducers

Issued August DATA SHEET. 3VT3 MCCB up to 630 A

AC axial compact fan

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

2.12. Ex-Linear light fittings for fluorescent lamps. nllk W - 58 W (Zone 2, 21, 22)

Internal Components Forms of Separation

MCB NB1-63H Miniature Circuit Breaker

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-T...

C60N circuit breakers0 B, C and D curves IEC 60898: 6000 A, IEC : 10 ka

System Extensions for Switchgear Manufacturing

LV-MV INSULATORS INSULATORS

Surface-mounting thermostats Series ATH

ATyS Automatic and remotely operated transfer switches from 125 to 3200 A

BASE. Rotary limit switch. OptiOnS. FEAtuRES. CERtiFiCAtiOnS

PHOENIX CONTACT - 04/2016. Features

Surface-mounting Thermostats ATH Type Series

Proximity Sensor Ideal for High Temperatures and Cleaning Processes. Applicable to 120 C

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

4.2. Ex-Ceiling light fittings AB 80 / AB 05 LED / AB 05 / AB 12 NAV 70. (Zone 1, 2, 21, 22)

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

AC axial compact fan

Non-Contact Safety Systems CMS

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Varius SUMMARY OF MODELS OF HRC FUSE-LINKS

ISEmax CAM40/CAS40. Technical Information

3VT4 Molded Case Circuit Breakers up to 1000 A

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Amphenol. Amphenol-Tuchel Electronics GmbH. Circular Connectors C 091 A/B/D Series

Field IT 50T Series Transmitters

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

AC axial fan. Limited partnership Headquarters Mulfingen Amtsgericht (court of registration) Stuttgart HRA

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

C120N circuit-breakers B, C and D curves EN 60898/EN 61009: IEC : 10 ka

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Capacitor Discharge called CD welding

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

Dimension OD±1. General Technical Data. Technical Characteristics GB IEC252:1992 Operating temperature -25 ~+70. Capacitance Tolerance

Film Capacitors. EMI suppression capacitors. Date: June 2018

Operating Instructions for Digital Manometer. Model: MAN-SD

T20WN. Data Sheet. Torque transducers. Special features. Installation example with bellows couplings. B en

SECTION 3 BASIC AUTOMATIC CONTROLS UNIT 12 BASIC ELECTRICITY AND MAGNETISM

Masterpact. Installation recommendations

Size : Ends : Min Temperature : Max Temperature : Materials : Brass

Imformation of C091D series

MINIATURE MICROSWITCHES - PREMIUM

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

90 MCB MODULAR CIRCUIT BREAKERS FOR CIRCUIT PROTECTION

Ref: HLSR 16-PW; HLSR 32-PW; HLSR 40-PW-000; HLSR 50-PW-000,

Precision Thin Film Chip Resistor Array

Selecting the current rating for equipment

Siemens AG Miniature Circuit Breakers. Totally Integrated Power SENTRON. Configuration. Edition 10/2014. Manual. siemens.

For the electronic measurement of current: DC, AC, pulsed..., with galvanic separation between the primary and the secondary circuit.

AUTOMOTIVE CURRENT TRANSDUCER OPEN LOOP TECHNOLOGY HC6H 400-S/SP1

Three Core XLPE/LSF/SWA/LSF Power Cable

5SP and 5SY Supplementary Protection UL 1077

Amphenol. Amphenol-Tuchel Electronics GmbH. Series C 146 Heavy Duty Connectors Core Programme

Overhead lines. 110 kv wood tower with guy wires

Installation Manual. Installation manual for PerfectEnergy Solar Modules. Content

All part numbers in the coding below start with "TC-" and end with "203"

Fault Calculation Methods

Chapter-Content Page 14.0 Surface Mounted Boxes 14.1 Flush Mounted Boxes 14.2 Distribution Pillar

Interference suppression film capacitors MKP 336 1

Transcription:

ELINEMK Technical Characteristics Rated Current Busbar Code Standards Rated Isolation Voltage Max. Rated Operational Voltage Rated Frequency Pollution Degree Protection Degree External Mechanical Impacts (IK Code)* Rated Short-time Withstand Current (1s) Rated Peak Withstand Current Rated Short-time Withstand Current for Neutral Conductor (1s) Rated Peak Withstand Current for Neutral Conductor Rated Short-time Withstand Current for CPE Conductor (1s) Rated Peak Withstand Current for CPE Conductor Rated Short-time Withstand Current for PE Conductor (1s) Rated Peak Withstand Current for PE Conductor MEAN PHASE CONDUCTOR CHARACTERISTICS AT RATED CURRENT In Resistance at a conductor temperature of 20 C R 20 Resistance at an ambient air temperature of 35 C R Reactance (Independent from Temperature) X Positive and negative sequence impedances at an ambient air temperature of 35 C Z Positive and negative sequence impedances at a conductor temperature of 20 C Rated Power Loss at 35 C DC Resistance at a conductor temperature of 20 C for Phases DC Resistance at a conductor temperature of 20 C for Neutral DC Resistance at a conductor temperature of 20 C for PE DC Resistance at a conductor temperature of 20 C for CPE SECTIONS L1,L2,L3,N PE (5 Conductors) PE (Sheet Metal) Conductor Dimensions Busbar Weight (4 Conductors) Busbar Weight (5 Conductors) MEAN FAULT-LOOP CHARACTERISTICS Zero-sequence Impedance Zero-sequence impedance at a conductor temperature of 20 C Zero-sequence impedance at a conductor temperature of 20 C Zero-sequence impedance at a conductor temperature of 20 C Zero-sequence impedance at an ambient temperature of 35 C Zero-sequence impedance at an ambient temperature of 35 C Zero-sequence impedance at an ambient temperature of 35 C Resistances and Reactances Resistance at a conductor temperature of 20 C Resistance at a conductor temperature of 20 C Resistance at a conductor temperature of 20 C Resistance at a conductor temperature of 20 C Resistance at an ambient air temperature of 35 C Resistance at an ambient air temperature of 35 C Resistance at an ambient air temperature of 35 C Resistance at an ambient air temperature of 35 C Reactance (Independent from temperature) Reactance (Independent from temperature) Reactance (Independent from temperature) Reactance (Independent from temperature) In A Copper Conductor (MKC) E L E K T R İ K 100 160 100 160 225 10 16 10 16 22 IEC 61439-6, TS EN 61439-6, IEC 61439-1, TS EN 61439-1 Ui Ue f 3 IP V V Hz 55 690 690 50 Plug-in Busbar IK07 I cw I pk I cw I pk I cw I pk I cw I pk Z 20 R/ort Ph R N R PE R CPE Z (0) b20phn Z (0) b20phpe Z (0) b20phcpe Z (0) bphn Z (0) bphpe Z (0) bphcpe R b20phph R b20phn R b20phpe R b20phcpe R bphph R bphn R bphpe R bphcpe X bphph X bphn X bphpe X bphcpe ka (rms) ka ka ka ka ka ka ka m /m m /m m /m m /m m /m W/m m /m m /m m /m m /m mm² mm² mm² mmxmm kg/m kg/m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m m /m Aluminium Conductor (MKA) 3,5 5,25 2,1 3,15 2,1 3,15 2,1 3,15 0,640 0,787 0,154 0,802 0,658 23,4 0,608 0,603 0,885 0,609 47,25 47,25 198 4,5x10,5 2,35 2,50 2,801 3,781 2,774 3,386 4,570 3,350 1,265 1,278 1,587 1,280 1,557 1,573 1,954 1,575 0,302 0,392 0,446 0,379 6 10,2 3,6 5,4 3,6 5,4 3,6 5,4 0,391 0,506 0,138 0,525 0,415 37,6 0,378 0,377 0,885 0,378 76,50 76,50 198 4,5x17 2,70 2,90 1,866 3,284 1,878 2,357 4,235 2,374 0,780 0,792 1,384 0,794 1,030 1,045 1,827 1,048 0,261 0,374 0,491 0,367 3,5 5,25 2,1 3,15 2,1 3,15 2,1 3,15 0,747 0,942 0,191 0,961 0,771 27,7 0,699 0,702 0,885 0,702 27 27 198 4,5x6 2,75 3,00 3,227 3,811 3,244 3,918 4,620 3,942 1,486 1,502 1,668 1,494 1,836 1,856 2,061 1,846 0,352 0,453 0,483 0,461 6 10,2 3,6 5,4 3,6 5,4 3,6 5,4 0,405 0,535 0,158 0,558 0,435 40,3 0,389 0,386 0,885 0,385 47,25 47,25 198 4,5x10,5 3,30 3,70 1,984 3,186 1,967 2,474 4,052 2,453 0,819 0,831 1,436 0,830 1,072 1,087 1,879 1,085 0,311 0,420 0,633 0,424 12,5 25 7,5 12,75 7,5 12,75 7,5 12,75 0,251 0,341 0,135 0,367 0,284 49,7 0,242 0,241 0,885 0,242 76,50 76,50 198 4,5x17 4,50 5,20 1,409 3,050 1,406 1,765 4,040 1,759 0,523 0,533 1,152 0,533 0,708 0,722 1,560 0,722 0,268 0,380 0,558 0,376 5

ELINEMK Declaration CE DECLARATION OF CONFORMITY E L E K T R İ K Product Group Manufacturer E-Line MK Busbar Energy Distribution System EAE Elektrik Asansor End. Insaat San. ve Tic. A.S. Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 Esenyurt-Istanbul This is to attest, under our sole responsibility, that the aforementioned products conforms with the determined regulations,guidelines and the below standards. Standard : EN 61439-6 Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems IEC 61439-6 Low-voltage switchgear and controlgear assemblies - Part 6: Busbar trunking systems (busways) CE - Directive 2006/95/EC Electrical equipment designed for use within certain voltage limits Date EAE Elektrik A. S. 23.02.2015 EAE Elektrik Asansor End. Insaat San. ve Tic. A. S. Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 Esenyurt-Istanbul Tel: +90 (212) 866 20 00 Fax: +90 (212) 886 24 20 www.eae.com.tr 22

ELINEMK Product Overview E L E K T R İ K PRODUCT OVERVIEW (100...225A MK) E L EshallK T R İ K a- The box shall only be plugged in and removed from the busbar at OFF position. 1- The busbar system shall have Al conductors for 100A and 160A or Cu conductors for 100A, 160A and 225A. 2- The busbar system shall conform to the following phase configuration. a- 4 conductors L1 / L2 / L3 / N / PE(Housing) b- 5 conductors L1 / L2 / L3 / N / PE+Housing c- 5 conductors (with clean earth) L1 / L2 / L3 / N / CPE / PE(Housing) 3- The insulation voltage of the busbar shall be 690V. 4- The busbar housing shall be of 0,60mm thick epoxy painted galvanized sheet metal. (RAL 7038) 5- The Al conductors shall be plated with nickel and then with tin, the Cu conductors shall be plated only with tin. The plating shall be continuous along the conductor. 6- The busbar joint shall have a single bolt construction and the nut of main joint bolt shall be a double headed nut, tightened at 20Nm. 7- The busbar housing shall be continuously clamped together by roll forming method. 8-10 plug-in windows shall be located on a standard 3m length. 9- Busbar and tap off boxes shall be IP55 protection class under normal operation conditions. 10- IP protection covers of plug-in points shall be hinged and lockable from single point. 11- Tap off boxes up to 16A shall be removed from the busbar before opening their lids. 12- The tap off boxes above 16A, shall have the following mechanical and electrical safety features. b- The energy on the connected load be automatically cut, when the box lid is open. c- The tap off box shall comply IP2X requirements, while it is plugged into the busbar and the lid is open. 13- All tap off box contacts shall be silver plated. 14- Jawed tap off box contacts shall be reinforced by steel springs. 15- Busbar systems shall be tested and certified according to IEC 61439-6 by international laboratories. 16- Busbar system shall have flexible elbows and expansion units. 17- Manufacturing facility of busbar systems shall have ISO 9001 and ISO 14001 certification. 23

ELINEMK Certificate E L E K T R İ K 24

EAE Elektrik A.Ş. Akcaburgaz Mahallesi, 119. Sokak, No:10 34510 Esenyurt-Istanbul-TURKEY Tel: +90 (212) 866 20 00 Fax: +90 (212) 886 24 20 www.eae.com.tr IEC 61439-6 T s E ME 04 ISO 9001 14001 ENVIRONMENTAL MANAGEMENT SYSTEMS QUALITY AND Catalogue 05-Eng. / Rev 07 1.000 Pcs. 25/02/2015 www. atamatbaa.net / A.C.E./ 612 40 66 EAE has full right to make any revisions or changes on this catalogue without any prior notice.