Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab

Similar documents
HRMS PBDE Analysis on a Thermo DFS. Dave Hope, Pacific Rim Laboratories Inc

Technical Report. Abstract: Pu Wang 1, Huizhong Sun 1, Qinghua Zhang 1, Feifei Tian 2, Lei Cao 2

Verification and Review of Data for Chlorinated Dioxins, Furans and PCB Congeners by Isotope Dilution HRGC/ HRMS

METHOD 3600C CLEANUP

PosterReprint INTRODUCTION

METHOD 3600B CLEANUP

Orbitrap GC-MS: An Opportunity to Help Address the Challenges of Chlorinated Paraffins Analysis

Fast and Accurate Analysis of PBDEs in a Single Run, Including BDE-209

Fast and Accurate Analysis of PBDEs in a Single Run, Including

Aroclors, Homologs and Congeners An Evaluation of the Options for PCB Analysis and a Comparison of the Interpretive Value

ApplicationNOTE THE ANALYSIS OF POLYCHLORINATED BIPHENYLS (PCBS) BY GC-HIGH RESOLUTION MASS SPECTROMETRY USING THE MICROMASS AUTOSPEC ULTIMA NT

Organochlorine Pesticides by GCxGC-ECD

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

Food analysis. Solutions for Your Analytical Business Markets and Applications Programs

U.S. EPA Method 8270 for multicomponent analyte determination

Methods of Analysis of Polychlorinated Biphenyl Congeners Using an Application-Specific Capillary GC Column

EPA Test Methods for GC

environmental Rtx -CLPesticides and Rtx -CLPesticides2 Columns: The Ideal Confirmational Pair for Analyzing Polychlorinated Biphenyls (PCBs)

A novel high resolution accurate mass Orbitrap-based GC-MS platform for routine analysis of Short Chained Chlorinated Paraffins

Dioxins & PCBs concerns

The Truth About Dioxin Analysis: Using High Resolution GC-TOFMS and GCxGC-TOFMS to. Analytical Approaches

Validation of GC-MS/MS for Detection and Confirmation of Low-Level Dioxins

Application Note. Abstract. Introduction. Determination of Polycyclic Aromatic Hydrocarbons in Seafood by an Automated QuEChERS Solution

GC Analysis of Polybrominated Flame Retardants Application

ENVIRONMENTAL analysis

METHOD 8100 POLYNUCLEAR AROMATIC HYDROCARBONS

PAHs in Parking Lot Sealcoats. Performance Study. Asphalt Based. Coal Tar Sealcoat Sealcoat. Sealcoat. Scrapings. Asphalt Based.

Putting the Pieces of the Puzzle Together. By Kim Kirkland, Methods Team Leader EPA s Office of Resource Conservation and Recovery

GC/MS/MS Dioxin and Dioxin-like PCBs in Feed and Food. Jessica Westland, LSAG Applications Chemist

Rosemary extract liquid

DETERMINATION OF OCs, PCBs AND SYNTHETIC PYRETHROIDS IN ANIMAL FAT

T H E ANA LYSIS O F DIOX INS AND F U R A NS USING H RG C- H IG H R E SO LU T IO N MS W IT H T H E AU T OS P EC- ULTIMA NT

Identification and Quantitation of PCB Aroclor Mixtures in a Single Run Using the Agilent 7000B Triple Quadrupole GC/MS

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Spectra Library Electron Capture Negative Ion (ECNI) Mass Spectra of Selected Polybrominated Diphenyl Ethers (PBDEs)

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Hans-Joachim Hubschmann. Handbook ofgc-ms. Fundamentals and Applications. Third Edition. Wl LEY-VCH. VerlagGmbH & Co. KG aa

Multi-residue Analysis for PAHs, PCBs and OCPs on Agilent J&W FactorFour VF-Xms

Fast, Quantitative Analysis of Residual Solvents in Cannabis Concentrates

Estimation of LOQ for the Analysis of Persistent Organic Pollutants, in particular PCDD/Fs and PCBs

Consideration of Non-radioactive Harmful Substances

APPLICATION NOTE Authors Jane Cooper, 1 Jordi Parera, 2 Esteban Abad, 2 Richard Law,¹ and Cristian Cojocariu 1

The Third Dimension of Information Vol. IV Applications with the Agilent Technologies Atomic Emission Detector. O H Cl. Fe Se

1.0 INTRODUCTION AND BACKGROUND

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

The Suite for Environmental GC Analysis

ONE STEP CLOSER TO A COOK BOOK METHOD FOR DIOXIN ANALYSIS PART 2: ANALYSIS OF FOOD SAMPLES

Polychlorinated biphenyls (PCBs)

The Practicality (Necessity) of Use of Clean-up Techniques for the Analysis of D/F and PCB Congeners

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

The Role of Proficiency Tests in the Estimation of Measurement Uncertainty of PCDD/PCDF and PCB Determination by Isotope Dilution Methods

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Gas Chromatography Mass Spectrometry (GCMS)

ApplicationNOTE ULTRA TRACE ANALYSIS OF DIOXINS AND FURANS IN HUMAN ADIPOSE TISSUE USING SFE-LC EXTRACTION/CLEANUP AND THE WATERS AUTOSPEC ULTIMA NT

TECORA Isostack G4 and DECS Stack Emissions Sampling. Methods for sampling emissions of Dioxins, Mercury and Heavy Metals

Multi-residue analysis of pesticides by GC-HRMS

Luminescence transitions. Fluorescence spectroscopy

ABI 3200 Q TRAP LC/MS/MS System

Katherine K. Stenerson, Michael Ye, Michael Halpenny, Olga Shimelis, and Leonard M. Sidisky. Supelco, Div. of Sigma-Aldrich Bellefonte, PA USA

PCBs and the Great Lakes

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

New Approaches to the Development of GC/MS Selected Ion Monitoring Acquisition and Quantitation Methods Technique/Technology

ISO INTERNATIONAL STANDARD. Soil quality Determination of organochlorine pesticides and. capture detection

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

Accurate, Reproducible Results for Environmental Methods with Zebron GC Columns

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

The following revisions are being implemented for the PCDD/F Supplemental QAPP:

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Accelerated Solvent Extraction GC-MS Analysis and Detection of Polycyclic Aromatic Hydrocarbons in Soil

Analysis of Illegal Dyes in Food Matrices using Automated Online Sample Preparation with LC/MS

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Analytical Instrumentation


CORUS R, D and T, Swinden Technology Centre, Rotherham, UK S60 3AR. HALL ANALYTICAL LABORATORIES, Manchester, UK M23 9YJ

Get Selective. By Jaap de Zeeuw

METHOD 8082A. POLYCHLORINATED BIPHENYLS (PCBs) BY GAS CHROMATOGRAPHY

Choosing Fit-For-Purpose Food Safety Methods

Learning centre Management Chemicals Issues of Importance for Sustainable Development. CSD-19 May 3, Beijing, April 2010

Determination of Polycyclic Aromatic Hydrocarbons (PAHs) in Seafood Using GC/MS

Speciation of Bromine Compounds in Ozonated Drinking Water using Ion Chromatography and Inductively Coupled Plasma Mass Spectrometry

Real Time On-Site Odor and VOC Emission Measurements Using a znose

Fast, Accurate Environmental Testing

The Theory of HPLC. Quantitative and Qualitative HPLC

DFS Magnetic Sector GC/MS

Thermo Scientific ICP-MS solutions for the semiconductor industry. Maximize wafer yields with ultralow elemental detection in chemicals and materials

Application Note. Agilent Application Solution Analysis of PAHs in soil according to EPA 8310 method with UV and fluorescence detection.

Generating the Right PCB Data: Determination of Aroclors Versus PCB Congeners 8075

Quantification of Pesticides in Food without Calibration using GC/FID with the Polyarc Reactor

2015 Delaware Estuary Science & Environmental Summit Jim Occhialini, Cindy McQueen Alpha Analytical

Uncontrolled Copy. SOP 109 Ethylene Glycol Screen by Gas Chromatography/Mass Spectrometry. Table of Contents. 1. Principle of Assay...

GUIDELINES ON THE USE OF MASS SPECTROMETRY (MS) FOR IDENTIFICATION, CONFIRMATION AND QUANTITATIVE DETERMINATION OF RESIDUES CAC/GL

PCB Chemistry 101. Presented by Valerie Tillinghast O Reilly, Talbot & Okun Associates, Inc.

Presentation Title. Isotope Dilution: Where it doesn t work Where we should expand its use. August 10, David I. Thal Principal Chemist

OBJECTIVE DATA PACKAGE DELIVERABLES

Advanced analytical methods in the determination of xenobiotics in water samples

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

METHOD 8033 ACETONITRILE BY GAS CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION

Bromierte Flammschutzmittel die erfolgreiche kritische Trennung von BDE 49/71 und BDE209

Transcription:

An Executive Summary Using Magnetic Sector GC-HRMS in a Commercial Dioxin Lab David Hope Chief Executive Officer Pacific Rim Laboratories Introduction Persistent organic pollutants (POPs) are toxic chemicals produced intentionally or as byproducts of industrial and agricultural activity. Due to their persistence, many of these compounds migrate naturally from the environment into plant food sources and up the food chain where they bioaccumulate in the fatty tissue of animals. Magnetic sector gas chromatography high-resolution mass spectrometry (GC-HRMS) systems are the highest performing mass spectrometers available for the routine target compound analysis of dioxins and POPs in all kinds of sample matrices. The practical use of these instruments has come a long way since 2005, when attaching two gas chromatographs to one source was new for magnetic sector instruments. This technique now provides full compliance worldwide with any regulatory method for detecting dioxins, polychlorinated biphenyls (PCBs), or polybrominated diphenyl ethers (PBDEs) in food and environmental matrices. This webcast summary explains how magnetic sector GC-HRMS can be used in a commercial POPs laboratory to increase throughput for dioxin analysis and presents data for the analysis of PCBs, organochlorine pesticides (OCPs), and PBDEs. This piece also presents the results of experiments designed to test the suitability and capabilities of magnetic sector GC-HRMS for target compound analysis, including precision, accuracy, and identification capabilities in targeted workflows as well as the software s ease of use and effectiveness. Dioxins and the Thermo Scientific DFS Magnetic Sector GC-HRMS In the early 1980s, researchers found a buildup of dioxins in herring gull eggs, and the release of these chemicals was traced to pulp and paper mill manufacturers. In 1989, the US Environmental Protection Agency (EPA) issued one of the first dioxin methods, EPA 1613, which specified minimum levels of 10 100 pg/l or 1 10 ng/kg. To test these sample types, early dioxin analyses were run using a Finnigan 3200 GC-MS instrument. Detection limits were adequate for the time, but with only single-unit resolution, specificity was limited and rigorous cleanup was required. Therefore, the development of dioxin methods such as EPA 1613 led to the need for GC-HRMS systems. Such higher resolution (>10,000) instruments have sensitivities less than 1 pg injected (one part per quadrillion, 10-15) and create fewer false positives, which is especially important for the most toxic dioxin chemicals such as tetrachlorodibenzo-p-dioxins (TCDDs). More recently, the Stockholm Convention has been the driver for HRMS and especially for dioxin detection. The Convention was established in 2001 and includes 179 different countries SPONSORED BY

or parties. Initially concerned with only 12 byproducts and manmade chemicals, several more compounds were added in 2009 under the Stockholm Convention. To detect dioxin levels, one can use two GC instruments, as shown with the Thermo Scientific DFS Magnetic Sector GC-HRMS in the schematic in Figure 1. Using two GC systems does not double sample analysis throughput, but it certainly improves it because two different chemistries can be run off the same instrument. Analysts can use a dioxin column placed in one GC instrument, and a PCB column in the second instrument so that analysis can switch back and forth between two methods without venting the MS source. HRMS Mainstream: PCB and PBDE Although the production of PCBs is banned, there are still unintended sources. For example, yellow dyes contain PCB-11 and building materials like caulks also contain PCBs. EPA Method 1668 was first introduced in 1997 for 12 dioxin-like PCBs and six markers. It has been revised many times since then and has expanded to include 209 congeners of PCBs with 27 carbon-13 labeled standards, which significantly complicating the method. With the current EPA Method 1668, a five- or a six-point calibration is run for the 27 standards and a single-point calibration for the remainder of the compounds (182) is performed. Unfortunately, no single column can resolve all 209 compounds of interest and MS systems dwell times on each one of the ions is short, which limits sensitivity. Thus, GC-HRMS system can provide the resolution that GC-MS instruments alone cannot. Brominated diphenyl ethers have also been an issue in the last 15 to 18 years as a potential contamination source Figure 1: Thermo Scientific DFS Magnetic Sector GC-HRMS. and their concentrations in the environment are of concern. For many of these compounds, HRMS instrumentation is not required, however HRMS systems can provide better sensitivity and isotope dilution can be used. Since brominated diphenyl ethers are increasingly prevalent in the environment, they can be found in food matrices that require detection in the low part per trillion range. When analyzing a matrix from a regulatory point of view, detection limits are important. When tracking compounds, it is more important to have an absolute value to determine if levels are increasing or decreasing, thus requiring the capabilities of HRMS systems. Methods for Polycyclic Aromatic Hydrocarbons (PAHs), Tributyltin, N-nitrosodimethylamine (NDMA), Nonylphenyls, and Organochlorine Pesticides Several additional methods can be run on a HRMS system. While HPLC instruments with UV and fluorescence detectors or GC/FID can be used for PAH analyses, US EPA methods now all require GC-MS. While GC-MS detection limits are adequate for regulatory purposes, they may not be low enough for the detailed investigation work that is suited for GC-HRMS analysis. Figure 2 illustrates the analysis of fish samples exposed to a fire in a commercial freezer. The local authorities would not release fish store in adjacent freezers until they were certain no PAH present. A testing method capable of detecting PAH in fish tissue at 0.1 0.3 parts per billion was needed. HRMS analysis was the selected for this purpose for its sensitivity. Some 3 pg of phenanthrene and anthracene were injected. Using GC-HRMS analysis, one can see the carbon-13 labeled analogs at 100 pg. Tr i b u t y l tin c a n a l s o b e analyzed via HRMS; using a derivatized deuterated analog of tributyltin, chloride detection limits of <0.001 μg/l or <0.001 mg/kg can be obtained. NDMA (a drinking water contaminant), nonylphenyls, monoethoxylate, and diethox ylate, are also commonly analyzed by HRMS when sensitivity is required. Nonylphenyl is comprised of approximately 20 compounds; with a gross detection limit of 0.01 µg/l, a detection limit of 10 20 times lower is needed for each individual compound. O C Ps a re a l s o p a r t of the Stockholm Convention. Traditionally analyzed using an electron capture detector (ECD) or GC-MS, the new EPA 1699 Method of HRMS analysis

C-PAH @ 100 Figure 2: Sensitivity not an issue 3 pg injected ( 13 C-PAH @ 100 pg). Phenanthrene Anthracene 13 C-PAH has recently been implemented. The scope of EPA 1699 includes 34 organochlorine pesticides and several carbon-13 standards. In addition, it covers organic pesticides such as triazenes and pyrethroids. Laboratories commonly use an in-house generated fivepoint calibration of 1 400 ng/ml with all analytes at the same concentration rather than the varying concentrations listed in EPA 1699. Isotope dilution is used for pesticides that have a carbon-13 labeled standard; internal standards are usually used for everything else. Normally, for HRMS analysis of halogenated compounds, two ions in each parent cluster are monitored; for dioxins and PCBs, the ion ratio should be within 15% of the theoretical. For EPA 1699, ±25% from theoretical is allowed. For sample cleanup, a fluorouracil column elution is split into two or three fractions to focus on a few example analytes at a time, as demonstrated in Figure 3 for the analysis of Endrin using a mid-level standard at 25 pg/µl and a low-level standard at 1 pg/µl. Figure 3: Analysis of Endrin using a mid-level standard at 25 pg/µl and a low-level standard at 1 pg/µl. New Techniques for HRMS One of the newest techniques used to improve efficiency in HRMS analyses is the Thermo Scientific DualData XL Module within the DFS Magnetic Sector GC-HRMS. The DFS DualData XL module enables higher throughput and faster response times by staggering injections from two GC

DFS DualData XL Module: Staggered Figure 4: DFS DualData XL module: staggered injection. Injection Figure 5: The system also allows for the use of mixed chemistries, all without venting the MS source. systems to maintain the EPA Method 1613b PCDD required minimum elution time of at least 25 minutes (see Figure 4). The DFS DualData XL mode eliminates the 20-minute wait at the beginning of the analysis by alternating between two GC systems. The second GC instrument injects 20 minutes before the finish of the first GC instrument s run. Then the first GC instrument re-injects 20 minutes before the finish of the second instrument s run. Using a single HRMS system, two GC instruments, and a microwafer, sample throughput can be doubled. The system also allows for the use of mixed chemistries, all without venting the MS source (see Figure 5). For example, with a standard run time of 62 minutes from injection to injection (including cool down and autosampler preparation), the resulting throughput is approximately 23 samples per day. But by running in the DFS DualData XL mode and eliminating the 20-minute offset at the beginning of each run, it takes 67 minutes to complete the cycles for both GC instruments, or approximately 42 injections per day (82% more samples). Other advantages of this module is that it is less expensive than buying a new instrument, it requires no additional floor space, does not require any additional electrical considerations, and the autosampler is ready to inject as soon as a ready signal is established. Another DFS DualData XL module example is presented in Figure 6 for the analysis of dioxins and PCBs. By combining the analysis of dioxins (62 minutes run time) and dioxin-like PCBs (48 minute run time), the DFS DualData XL module run time is only 57 minutes, which is less time

Figure 6: DFS DualData XL module example for the analysis of dioxins and PCBs. PCDD/F & dlpcb PCDD\H 5unQme DHE nz minutes dlpcb 5unQme DHE jv minutes 5unQme DualData XL Module 57 minutes to complete cycle for both GCs Therefore, you can run dioxins and PCBs to@ether in less Qme than it tales to run one dioxin sample!!! than running a dioxin analysis alone, using the HRMS much more efficiently. Conclusion HRMS analysis is a valuable tool for any commercial laboratory; with the DualData XL Module within the DFS Magnetic Sector GC-HRMS, it becomes even more valuable. The DFS DualData XL mode significantly increases laboratory efficiency and diversity, since it is not limited to running the same column or GC program on each GC instrument, and the MS source does not need to be vented when changing columns, capabilities are expanded significantly. In addition, because the burn-off at the end of a dioxin or a PBC run is vented to vacuum and not going onto the source, with the DFS DualData XL mode, the source stays much cleaner, resulting in less down time in cleaning, also improving laboratory efficiency.