Identification Of The Common Laboratory Glassware, Pipettes And Equipment. BCH 312 [Practical]

Similar documents
Experiment 8 Introduction to Volumetric Techniques I. Objectives

Volumetric Measurement Techniques. Technique #1 Use of a Burette. Technique #2 Use of a Pipette. Technique #3 Use of a Volumetric Flask

Potentiometric measurement of ph

DETERMINATION OF THE SOLUBILITY PRODUCT OF GROUPII HYDROXIDES

PRACTICAL 3 ph AND BUFFERS

# 12 ph-titration of Strong Acids with Strong Bases

MEASUREMENT: PART II

CHEM 334 Quantitative Analysis Laboratory

CHEM Practice to be done before the lab. Experiment 9 Introduction to Volumetric Techniques II. Objectives

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

The Determination of an Equilibrium Constant

6 Acid Base Titration

Experiment 7A ANALYSIS OF BRASS

Basic Equipments and Instruments used in Chemistry laboratory: Balance: It is an instrument for measuring mass.

Experiment 8 and 9 Weak Acids and Bases: Exploring the Nature of Buffers

Volumetric Analysis. Quantitative analysis answers the second question

Unit 5 Part 2 Acids, Bases and Salts Titrations, Indicators and the ph Scale UNIT 5 ACIDS, BASES AND SALTS

Measurement and Lab Equipment Basics Guided Notes

not to be republished NCERT YOU are already aware that a substance is analysed to establish its qualitative TITRIMETRIC ANALYSIS UNIT-6

#13 ph-titration of Weak Acids with Strong Bases

The Determination of an Equilibrium Constant

Introduction to Small Scale Chemistry

Final Concentration 0 excess 0.1 M 0.1 M

Basic Equipment. 2D.1 Equipment for Measuring Mass

Determination of an Equilibrium Constant

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

1,5-Diphenylcarbohydrazide Method* Powder Pillows or AccuVac Ampuls (0 to mg/l Cr 6+ )

Accuracy and Precision of Laboratory Glassware: Determining the Density of Water

Techniques for Volumetric Analysis

Experiment 3: Acids, Bases, and Buffers

Ascorbic Acid Titration of Vitamin C Tablets

Experiment 1. Determination of the Density of Water and an Unknown Solid Sample

Chemical Equilibrium: Finding a Constant, Kc

2. MASS AND VOLUME MEASUREMENTS Mass measurement Analytical and standard laboratory balances Pre-lab Exercises

Chemistry Calibration of a Pipet and Acid Titration

Determination of the K a of a Weak Acid and the K b of a Weak Base from ph Measurements

Titration of an Unknown Acid

Exercise 4-4. Titration of a Buffer Solution EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Buffer solutions

Objectives To prepare a dilute solution of a weak acid. To prepare a buffer of a specific ph value.

Pre-lab: Read section 9.9 (pages ) on acid-base titrations in the textbook. Complete the attached pre-lab by Tuesday, June 2.

Titrations. Method for Titration. N Goalby chemrevise.org 1. Using the pipette

1) A ph/mv meter or an ion meter, either line operated or portable.

Figure 1. A portion of a metric ruler (the centimeter scale has been enlarged for ease in reading).

Density of an Unknown

Chemistry Potentiometric Titration of a Chloride-Iodide Mixture

Experiment: Titration

The Determination of an Equilibrium Constant

NaOH (aq) + HCl (aq) NaCl (aq) + H 2 O (l)

1 Measurements and Calculations

Volumetric analysis involving acids and alkalis

1iI1E. The Determination of 0 an Equilibrium Constant [LU. Computer

ANALYTICAL CHEMISTRY. Basic Skills in Chemical Laboratory

Unit 3 Chemistry - Volumetric Analysis

Experiment 20: Analysis of Vinegar. Materials:

Introduction to Chemistry Techniques Prelab (Week 1) 2. Determine the number of significant figures in each of the following numbers.

PRETREATMENT TECHNICAL DATA SHEET CHROMIUM-FREE ORGANIC PASSIVATING RINSE PRODUCT DESCRIPTION

GENERAL INSTRUCTIONS GENERAL PREPARATION

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

DR/4000 PROCEDURE. IRON, Total

Titration with an Acid and a Base

Experiment 32C APPLICATIONS OF ACID-BASE EQUILIBRIA

Chem(Bio) Week 6 Expt F: Amino Acid pka from potentiometry. Identification of an Amino Acid through Potentiometric Titration

Titration of Acetic Acid in Vinegar Minneapolis Community and Technical College v.9.17

Checklist for Titration

Determining the Concentration of a Solution: Beer s Law

Name: Date: AP Chemistry. Titrations - Volumetric Analysis. Steps for Solving Titration Problems

POGIL LAB EXERCISE 15 HOW DO YOU STANDARDIZE AN ACID AND BASE?

Determination of the Equivalent Weight and the K a or K b for a Weak Acid or Base

K a Acid Dissociation Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.9.13

Partner: Alisa 1 March Preparation and Properties of Buffer Solutions

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Determination of Orthophosphate Ion

O H 3 O 1 1 A. O 1 1 OH (K w

EXPERIMENT 1 Chemistry 110 LABORATORY SAFETY

2 (aq) [FeSCN [Fe 3JSCN] Figure 1

Ka Acid Dissociation Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.1.16

PRETREATMENT TECHNICAL DATA SHEET A CHROME-FREE FINAL RINSE PRODUCT DESCRIPTION

Determining the Concentration of a Solution: Beer s Law

Chemical Reactions: Titrations

EXPERIMENT 22 SOLUBILITY OF A SLIGHTLY SOLUBLE ELECTROLYTE

In this laboratory exercise we will determine the percentage Acetic Acid (CH 3 CO 2 H) in Vinegar.

MEASUREMENTS AND ERRORS

Chapter 9. Volumetric Analysis

Chemical Equilibrium: Finding a Constant, Kc

Experimental Procedure. Lab 406

Buffer Preparation. Learning Objectives:

Analyzing Hydrogen Peroxide Solution Chemistry 30

SOLVOLYSIS OF tert-butyl CHLORIDE: TESTING A MECHANISM

Determination of the K a Value and Molar Mass of an Unknown Weak Acid

Determining the Concentration of a Solution: Beer s Law

Safety Note: Safety glasses and laboratory coats are required when performing this experiment

OPS LABORATORY PROCEDURE 2015 (Subject to Revision) Revision 1 3/31/15

Chemical Equilibrium: Finding a Constant, Kc

Experiment 7: ACID-BASE TITRATION: STANDARDIZATION OF A SOLUTION

CHEMISTRY 135 General Chemistry II. Determination of an Equilibrium Constant

(b) Write the chemical equation for the dissolution of NaOH in water.

Laboratory Measurements and Procedures

INTRODUCTION TO ACIDS, BASES AND TITRATION

Practice Lab. Balances and calibration of volumetric tools

Transcription:

Identification Of The Common Laboratory Glassware, Pipettes And Equipment BCH 312 [Practical]

(1) Identification of the common laboratory glassware : Conical flasks and beakers: Graduated cylinders Volumetric flasks Burettes They are used for mixing, transporting and reacting, but not for accurate volume measurements. Used to measure the volume of a liquid. Graduated cylinders are generally more accurate and precise than laboratory flasks and beakers. It is used to make up a solution of fixed volume very accurately. (preparing standard solutions and reagents) A burette delivers measured volumes of liquid. Burettes are used primarily for Titration. Conical flask Beaker measuring cylinder Volumetric flasks Burettes

(2) Identification of laboratory Pipettes: Are Tools commonly used to transport a measured volume of liquid. Pipettes come in several designs for various purposes with differing levels of accuracy. There are three main type of pipettes are used in biochemical laboratory: (a) Volumetric or transfer pipettes. (b) Graduated or measuring pipettes. (c) Micropipettes

Types of pipettes (a)volumetric pipettes. [transfer ] (b)graduated pipettes. [measuring] Micropipettes Serological pipette Mohr pipette

Comparison between type of pipettes Volumetric pipettes Graduated pipettes Transfer (designed to deliver accurately fixed volume of liquid) Measuring Not graduated More accurate Non-blown out Consists of a cylindrical bulb joined at both ends to narrowed glass tubing. Graduated Less accurate Some are blown out Don t contain a cylindrical bulb

Reading the meniscus

Steps of the Use of pipettes: 1-Press the pipette into the pump with a slight twisting motion. 2-The pipette is first washed with water,then rinsed several times with a little of the solution. 3-The pipette then filled to just above the mark, the liquid is allowed to fall to the mark. 4-The solution is allowed to drain into the appropriate vessel with the jet of the pipette touching the wall of the vessel. 5-After the flow of the liquid has stopped, the jet is held against the wall for some times and then removed. Note: -For serological pipette, some are of the blown out type; the last drop being blown out against the vessel wall. -For volumetric pipette a certain amount of liquid will remain at the tip and this must not be "blown out".

Accuracy 1- Volumetric flasks and volumetric pipettes (most accurate). 2-Burets and graduated pipets. 3-Graduated cylinders. 4-Beakers and conical flasks. (least accuracy) -used only when a rough estimation of volume is required-

(2) Identification of the common laboratory Equipment: (A) ph meter. (B) Spectrophotometer. (C) Balance.

ph meter: The term ph introduced as a way of expressing hydrogen ion concentration. PH define as the negative logarithm of the hydrogen ion concentration. PH = - log10 [H+] PH determines many important aspects of the structure and activity of biological macromolecules and thus of the behavior of the cell and organisms. PH range value (0-14), the higher PH number, the lower the hydrogen ion concentration (Alkaine) and vice versa (inverse relationship).

There are many ways in biochemical laboratory to measure PH value such as litmus s paper, a field kit PH meter. The most accurate and reliable method

(A) ph meter A ph meter is an electronic device used for measuring the ph (acidity or alkalinity)of a liquid. Note: before use it needs to be calibrated Calibration : To ensure accurate measurements from your ph meter the meter will need to be calibrated before use. This is usually done by dipping the probe into a buffer solution of a known ph (ph4,7and10)and following the calibration steps based on our specific ph meter. ph meter contain glass electrode which is very sensitive and readily responds to changes in hydrogen ion concentration. How to use the ph meter: https://www.youtube.com/watch?v=vwy-xwmam7o Principle: https://www.youtube.com/watch?v=p1wrxtl2l3i

Using a ph Meter: The meter must be calibrated by using standards of known ph before an unknown is measured., the ph 4.00, ph 7.00 and ph10 standards should be used. To calibrate the ph meter, expose the hole in the electrode, rinse the electrode with deionized water, and place the electrode in the first standard solution then press Cal bottom. Don t forget to rinse the electrode with water after reading ph of each standard solution. Place the electrode into the unknown solution and press Read bottom. Do not drop the electrode or bump it on the bottom of the beaker when immersing it in a solution. The glass membrane must be thoroughly hydrated to work properly. Do not allow the electrode to remain out of water any longer than necessary. When the electrode is not in use, keep it immersed in the buffer.

(B) Spectrophotometer Spectrophotometer is instrument used to measure the amount of light absorbed or transmitted by a sample at a given wavelength. Wavelength in this instrument divided into: Invisible range(ultraviolet) from 100 to 360 nm [Quartz cuvette are used] Visible range (above 360 nm -700 nm) [Glass or plastic cuvette are used] Blank : contain everything except the compound to be measure.

Con t By using the spectrophotometer, we can quantitatively measure absorbance, and this information can be used to determine the concentration of the absorbing molecule. There is a direct relationship between concentration and absorbance. More concentrated solution will absorb more light and transmits less. (vice versa)

How does a spectrophotometer work? (principle) http://www.youtube.com/watch?v=pxc6f7bk8cu

(c) Electronic balance Electronic Balance is a device used to find accurate measurements of weight. It provide the results digitally, making them an easy tool for use. The weight can be displayed by different unites. Before waiting any substance, you should (Zero) the balance. What does mean zeroing of the electronic balance? (mass of beaker + substance) -(mass of beaker) = (mass of substance) How to use electronic balance https://www.youtube.com/watch?v=0uymytjatlc

Practical Part

Objective To be familiar with the common laboratory tools and equipment.

Method and Results (1) Identification of the common laboratory glassware Glassware number Type of glassware Final volume (capacity) 1 2 3 4 5

(2) Comparison between glassware accuracy 1-Place a beaker in the electronic balance, and read the weight. 2-Remove the beaker from the balance, and add 5ml of water using a graduated pipette (Mohr). 3-Record the weight. 4-Repeat the procedure again by using measuring cylinder this time. 5-Record the weight. Type of glassware Weight of beaker(g) Weight of beaker + water(g) Weight of water (g) Graduated pipette (Mohr) Measuring cylinder Which one is more accurate?.

(3) Identification of laboratory pipettes: 1-Examine the three pipettes placed on your laboratory bench. 2-Record their types and the volume of their smallest division. A B C Type of pipette Smallest division

(4) Identification of the commo laboratory equipment: A. ph meter: 1-Standardize the PH meter by placing the electrode in a solution of known ph (PH 4, 7, 9) Calibration. 2-Wash the electrode with distilled water and dry by tissue then put it into sample solution A then wash it again and place it in solution B Read ph. Note: After use the electrode, you should storage it in distilled water and never be allowed to dry out. If the electrode get dry it will required reactivation. Standard ph4 Standard ph7 Standard ph9 Sample A Sample B Solution ph value Neutral, acidic or basic

(4) Identification of the commo laboratory equipment: B. Spectrophotometer: 1-Adjust the spectrophotometer to zero using water as blank solution in the cuvette. 2-Read the absorbance of standard solution and the solution of unknown concentration at 280 nm. 3-Read your result. Solution Absorbance at 280 BSA standard solution (0.5 g/100 ml) Solution of Unknown concentration

Calculations: Where: C standard =concentration of standard solution, C unknown=concentration of unknown solution, A standard=absorbance of standard solution, A unknown=absorbance of unknown solution.

H.W Why quartz cuvette used in the case of invisible wavelength?