TAKING SUBSOIL SUSCEPTIBILITY INTO ACCOUNT IN DESIGNING COLUMNS IN REINFORCED SINGLE-STOREY STRUCTURES

Similar documents
CZASOPISMO TECHNICZNE TECHNICAL TRANSACTIONS CIVIL ENGINEERING BUDOWNICTWO 4-B/2015

FREE VIBRATION FREQUENCIES OF THE CRACKED REINFORCED CONCRETE BEAMS - METHODS OF CALCULATIONS

Clayey sand (SC)

Analysis of the horizontal bearing capacity of a single pile

APPLICATION OF ARTIFICIAL NEURAL NETWORKS TO PREDICT THE DEFLECTIONS OF REINFORCED CONCRETE BEAMS

DISPLACEMENTS OF CHIMNEY IN THE LIGHT OF COMPUTER CALCULATIONS AND SURVEYING

Design of reinforced concrete sections according to EN and EN

Sabah Shawkat Cabinet of Structural Engineering Walls carrying vertical loads should be designed as columns. Basically walls are designed in

TRUSS ANALYSIS IN VIEW OF THE REPLACEMENT OF DEGRADED STRUCTURAL COMPONENTS

ε t increases from the compressioncontrolled Figure 9.15: Adjusted interaction diagram

Metal Structures Lecture XIII Steel trusses

Verification of a Micropile Foundation

CALCULATION OF A SHEET PILE WALL RELIABILITY INDEX IN ULTIMATE AND SERVICEABILITY LIMIT STATES

ANALYSIS OF EMBEDDED RETAINING WALL USING THE SUBGRADE REACTION METHOD

THE PILE STIFFNESS IN A PILED-RAFT FOUNDATION SZTYWNOŚĆ PALA W FUNDAMENCIE PŁYTOWO-PALOWYM

Soil-Structure Interaction in Nonlinear Pushover Analysis of Frame RC Structures: Nonhomogeneous Soil Condition

Module 3. Analysis of Statically Indeterminate Structures by the Displacement Method

Design of AAC wall panel according to EN 12602

NUMERICAL SIMULATIONS OF CORNERS IN RC FRAMES USING STRUT-AND-TIE METHOD AND CDP MODEL

Influence of residual stresses in the structural behavior of. tubular columns and arches. Nuno Rocha Cima Gomes

Feasibility of dynamic test methods in classification of damaged bridges

STIFFNESS NONLINEAR ANALYSIS OF SECTIONS FOR REINFORCED CONCRETE MEMBERS SZTYWNOŚCIOWA NIELINIOWA ANALIZA PRZEKROJÓW ŻELBETOWYCH

THE NUMERICAL MODELLING AND ANALYSIS OF RC CRACKED STRUCTURES

UNIT II SLOPE DEFLECION AND MOMENT DISTRIBUTION METHOD

3 Hours/100 Marks Seat No.

Introduction to Structural Member Properties

Buckling Resistance Assessment of a Slender Cylindrical Shell Axially Compressed

Seismic design of bridges

D : SOLID MECHANICS. Q. 1 Q. 9 carry one mark each.

Entrance exam Master Course

EAS 664/4 Principle Structural Design

DYNAMIC ANALYSIS OF PILES IN SAND BASED ON SOIL-PILE INTERACTION

QUESTION BANK. SEMESTER: V SUBJECT CODE / Name: CE 6501 / STRUCTURAL ANALYSIS-I

KINGS COLLEGE OF ENGINEERING DEPARTMENT OF MECHANICAL ENGINEERING QUESTION BANK. Subject code/name: ME2254/STRENGTH OF MATERIALS Year/Sem:II / IV

Validation of the Advanced Calculation Model SAFIR Through DIN EN Procedure

RELIABILITY ASPECTS OF DESIGN OF COMBINED PILED-RAFT FOUNDATIONS (CPRF)

EUROCODE EN SEISMIC DESIGN OF BRIDGES

Structural Steelwork Eurocodes Development of A Trans-national Approach

DISSIPATIVE FORCES IN JOINT SURFACE OF COMPOSITE REINFORCED CONCRETE FLOORS SIŁY ROZPRASZAJĄCE ENERGIĘ W ZESPOLENIU ŻELBETOWYCH STROPÓW WARSTWOWYCH

SRI CHANDRASEKHARENDRA SARASWATHI VISWA MAHAVIDHYALAYA

S TRUCTUR A L PR E- A N A LYSIS TA B LES

CHAPTER 4: BENDING OF BEAMS

Seismic Assessment of a RC Building according to FEMA 356 and Eurocode 8

twenty one concrete construction: shear & deflection ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

QUESTION BANK DEPARTMENT: CIVIL SEMESTER: III SUBJECT CODE: CE2201 SUBJECT NAME: MECHANICS OF SOLIDS UNIT 1- STRESS AND STRAIN PART A

Chapter Objectives. Design a beam to resist both bendingand shear loads

AN ATTEMPT TO IMPROVE THE AXISYMMETRIC MODEL OF A PNEUMATIC TIRE

Slenderness Effects for Concrete Columns in Sway Frame - Moment Magnification Method (CSA A )

M.S Comprehensive Examination Analysis

Ph.D. Preliminary Examination Analysis

ON THE DESIGN OF A STEEL END-PLATE BEAM-TO-COLUMN BOLTED JOINT ACCORDING TO PN-EN

A METHOD OF LOAD INCREMENTS FOR THE DETERMINATION OF SECOND-ORDER LIMIT LOAD AND COLLAPSE SAFETY OF REINFORCED CONCRETE FRAMED STRUCTURES

CE5510 Advanced Structural Concrete Design - Design & Detailing of Openings in RC Flexural Members-

REINFORCED CONCRETE DESIGN 1. Design of Column (Examples and Tutorials)

METHODS OF DIAGNOSING AN ACWW 1000 SUGAR CENTRIFUGE WITH THE USE OF VIBRATION PROCESSES *

Reinforced concrete structures II. 4.5 Column Design

6. Bending CHAPTER OBJECTIVES

DEFORMATION CAPACITY OF OLDER RC SHEAR WALLS: EXPERIMENTAL ASSESSMENT AND COMPARISON WITH EUROCODE 8 - PART 3 PROVISIONS

needed to buckle an ideal column. Analyze the buckling with bending of a column. Discuss methods used to design concentric and eccentric columns.

4.3 Moment Magnification

3. Stability of built-up members in compression

Gapping effects on the lateral stiffness of piles in cohesive soil

Experimental setup and Instrumentation

Module 6. Approximate Methods for Indeterminate Structural Analysis. Version 2 CE IIT, Kharagpur

Dr. Hazim Dwairi. Example: Continuous beam deflection

Available online at ScienceDirect. Procedia Engineering 172 (2017 )

Structural Calculations for Juliet balconies using BALCONY 2 System (Aerofoil) handrail. Our ref: JULB2NB Date of issue: March 2017

CHAPTER 4. ANALYSIS AND DESIGN OF COLUMNS

Comparison of Structural Models for Seismic Analysis of Multi-Storey Frame Buildings

STRUCTURAL ANALYSIS BFC Statically Indeterminate Beam & Frame

Structural Steelwork Eurocodes Development of A Trans-national Approach

ASSESSMENT OF LOAD CAPACITY OF THE AIRPORT PAVEMENT STRUCTURE WITH THE USE OF THE ACN-PCN METHOD

FLOW CHART FOR DESIGN OF BEAMS

Rigid and Braced Frames

Design of Reinforced Concrete Beam for Shear

Annex - R C Design Formulae and Data

Software Verification

Software Verification

Codal Provisions IS 1893 (Part 1) 2002

Accordingly, the nominal section strength [resistance] for initiation of yielding is calculated by using Equation C-C3.1.

BEAM DEFLECTION THE ELASTIC CURVE

INTI COLLEGE MALAYSIA

Vertical acceleration and torsional effects on the dynamic stability and design of C-bent columns

to introduce the principles of stability and elastic buckling in relation to overall buckling, local buckling

MECHANICS OF MATERIALS

Software Verification

DEPARTMENT OF CIVIL ENGINEERING

INELASTIC SEISMIC DISPLACEMENT RESPONSE PREDICTION OF MDOF SYSTEMS BY EQUIVALENT LINEARIZATION

14. *14.8 CASTIGLIANO S THEOREM

Finite Element Modelling with Plastic Hinges

Method of Virtual Work Frame Deflection Example Steven Vukazich San Jose State University

Design of Reinforced Concrete Beam for Shear

PILE SOIL INTERACTION MOMENT AREA METHOD

Example 4.1 [Uni-axial Column Design] Solution. Step 1- Material Step 2-Determine the normalized axial and bending moment value

Design of Beams (Unit - 8)

Beam Design and Deflections

Engineeringmanuals. Part2

QUESTION BANK SEMESTER: III SUBJECT NAME: MECHANICS OF SOLIDS


SERVICEABILITY LIMIT STATE DESIGN

Transcription:

TECHNICAL SCIENCES Abbrev.: Techn. Sc., No 13, Y 2010 DOI 10.2478/v10022-010-0008-5 TAKING SUBSOIL SUSCEPTIBILITY INTO ACCOUNT IN DESIGNING COLUMNS IN REINFORCED SINGLE-STOREY STRUCTURES Krzysztof Klempka 1, Michał Knauff 2 1 Chair of Civil Engineering and Building Constructions University of Warmia and Mazury in Olsztyn 2 The Institute of Building Structures Warsaw University of Technology K e y w o r d s: subsoil susceptibility, effective length of columns, method based on nominal stiffness, second order effects, reinforced concrete buildings, reinforced concrete structures. Abstract When the Polish norm for designing concrete constructions will be replaced in 2010 by the Eurocode, its limits referring to columns slenderness will no longer bide. While designing reinforced slender columns in single-storey buildings, it is vital to consider all the factors which may influence the bearing capacity, one of which is the increment of the bending moment caused by the rotation of foundations supported by susceptible soils. The following article presents examples of the second order calculations taking into account the influence of subsoil susceptibility and columns nominal stiffness, as defined in the Eurocode. UWZGLĘDNIANIE PODATNOŚCI PODŁOŻA W PROJEKTOWANIU SŁUPÓW HAL ŻELBETOWYCH Krzysztof Klempka 1, Michał Knauff 2 1 Katedra Budownictwa i Konstrukcji Budowlanych Uniwersytet Warmińsko-Mazurski w Olsztynie 2 Instytut Konstrukcji Budowlanych Politechnika Warszawska S ł o w a k l u c z o w e: podatność podłoża, długość obliczeniowa słupa, metoda nominalnej sztywności, efekty drugiego rzędu, hale żelbetowe, konstrukcje żelbetowe. Abstrakt Po wycofaniu (w 2010 r.) polskiej normy projektowania konstrukcji z betonu i zastąpieniu jej przez Eurokod przestaną obowiązywać zawarte w tej normie ograniczenia smukłości słupów.

Taking Subsoil Susceptibility into Account... 81 Projektując smukłe żelbetowe słupy w halach, trzeba rozpatrzyć wszystkie czynniki, które mogą mieć wpływ na nośność jednym z nich jest przyrost momentu zginającego wywołany obrotem fundamentu na podatnym podłożu. W artykule przedstawiono przykłady obliczeń według teorii II rzędu z uwzględnieniem wpływu podatności podłoża i nominalnych sztywności słupów, zdefiniowanych w Eurokodzie. Introduction While designing columns in reinforced concrete single-storey buildings, it is not usual to take into account the influence of subsoil susceptibility on bending moments, illustrated in Fig. 1b. a e N H b e N H Fig. 1. Eccentricity increase: a) only resulting from the deflection of the column, b) resulting from the deflection and foundation rotation through angle ϕ The PN-B-03264 norm, which still bides, recommends that the column s slenderness should not be larger than l 0 /i = 104 (l 0 /h=30). This norm is to be withdrawn in 2010 and replaced by the Eurocode, which does not contain any arbitrary limits in case of the slenderness of columns; any slenderness may be used as long as it can be proved by calculations that the bearing capacity is sufficient. Canceling the limits of slenderness and using better materials will make it possible to design columns that are even more slender than before. According to the new general rules for designing (point 5.8.7 in Eurocode 2 (abbr. EN)), Where relevant, soil-structure interaction should be taken into account. As a result of the deflection of a column due to the first and second order effects (Fig. 1a), we obtain the increment of eccentricity of the applied

82 Krzysztof Klempka, Michał Knauff longitudinal force, as well as the increment of the bending moment of the column. The foundation rotation causes an additional increment of the moment as shown in Fig. 1b. The moment increments associated with the second order effects may be calculated using two methods. The first one is a simplified method based on the concept of isolated members. To use it, it is necessary to calculate the effective length of the column being designed. EN does not give any defined effective lengths of isolated columns supported by elastic soil but only recommendations (Fig. 5.7 f, g in EN 1992-1-1) which are too general for immediate usage. The effective length of columns directly supported by foundations depends on soil susceptibility and the size of foundations. Formulae for effective lengths of isolated columns were presented in publications by KOBIAK and STACHURSKI (1989) which had been based on the works of the German scientists FISCHER (1965) and KANY (1974). The second method is the exact method based on the second order analysis of the whole frame structure. To use the exact method does not require calculating effective lengths the shape of deformed elements and the associated increment of moments are determined in direct calculation. The examples of how this method may be used were presented in publications by KNAUFF and KLEMPKA in 2009. The next part of the article will present the method of calculating the coefficient of subsoil susceptibility and shaping the foundation rotation supported by elastic soil. This will be followed by calculation results for some examples of frame structures. Subsoil susceptibility coefficient in Winkler model Winkler s rotation angle of foundation on soil (Fig. 2a) may be calculated using the following formula ϕ = M (1) C z I F where I F the moment of inertia of the area of the foundation s base, C z subsoil elasticity coefficient. Coefficient C z is not a material constant because it does not depend only on the physical characteristics of the soil but also on the dimensions of foundations. To determine its value we have to take into account uniform elastic

Taking Subsoil Susceptibility into Account... 83 half-space with characteristics defined by modulus E 0 and Poisson s ratio ν. The value of the rotation angle of the foundation may be determined from formula (2) which comes from the article by GORBUNOV-POSADOV (1956). ϕ = 4M(1 ν 0 2 ) π E 0 b l 2 (2) (1) and (2) show that the soil elasticity coefficient used in Winkler s model has to be expressed by the following dependence: Taking into account that C z = π E 0b l 2 4I F (1 ν 0 2 ) We obtain I F = b (2l)3 = 2 b l 3 12 3 C z = 3π E 0 8l (1 ν 02 ) (3) a M b M h L surface of foundation Cz EI l l b I F Fig. 2. Foundation supported by elastic soil (a); the way of shaping the influence of the ground in static calculations of foundations (b)

84 Krzysztof Klempka, Michał Knauff If we want to take the foundation rotation into account in static calculation of frames, we can assume that our model of a column s support will be a hypothetical bar like the one in Fig. 2b (with its length expressed by L and its stiffness by EI). The rotation angle on the bar s support, caused by moment M can be derived from formula (4): ϕ = ML (4) 3EI It may be seen from (1) and (4) that length L and stiffness EI of the hypothetical bar should be selected in such a way that its flexural stiffness 3EI/L satisfies the following dependence 3EI = IF C z (5) L Analysis of calculation results for examples of single-storey frames Below we present examples of calculations of bending moments in columns of single-storey reinforced concrete buildings. For the calculations we used the exact method based on the second order analysis taking into account the nominal stiffness as described in the article by KNAUFF and KLEMPKA (2009). We analysed the case of columns fully fixed to the foundation base as well as the case of a column fixed to the foundation supported on elastic subsoil. We assumed the same foundation base 3.0 2.0 m for all the cases. The base is fixed on genesis-c cohesive, hard saturated plastic soil where I L = 0.20, E 0 = 20 MPa, ν = 0.32. The moment of inertia of the area of the foundation s base is I F = 2 b l 3 = 2 2 1.5 3 = 4.5 m 4 3 3 And the subsoil elasticity coefficient is C z = 3π E 0 = 3π 20 = 17.50 MN/m 3 8l (1 ν 2 0 ) 8 1.5 (1 0.32 2 )

Taking Subsoil Susceptibility into Account... 85 Using formula (5) we calculated the flexural stiffness of the hypothetical bars shaping the support 3EI = IF C z = 4.5 17.50 = 78.75 MNm L Example 1 Computational longitudinal forces in three-nave single-storey building (Fig. 3) are P 1 = 450 kn in the edge columns and P 2 = 900 kn in internal columns. The eccentricity resulting from cover load in edge columns is 0.15 m. a P 1 P 2 P 2 P 1 H 7.0 0.15 3 16.0 0.15 b 67.5 67.5 c 96.9 67.5 225.0 225.0 169.5 67.5 127.4 259.2 259.2 194.7 Fig. 3. Example 1. a) the diagram of the single-storey building, b) bending moments for fully fixed columns [knm], c) moments calculated with subsoil susceptibility [knm]

86 Krzysztof Klempka, Michał Knauff The horizontal force caused by wind pressure and suction equals H = 36 kn. We assumed that the stiff roof construction imposes identical horizontal shift of the top ends of all the columns. Columns (concrete C40/50, steel A-III) have identical cross sections b = 40 cm, h = 45 cm. We also assumed that the reinforcement in the edge columns is 3φ20 (A s = 9.42 cm2), and in the internal columns is 5φ20 (A s = 15.71 cm 2 ) on each side of the cross section. Imperfections according to point 5.2 EN equal α h = 2 = 2 = 0.756, α m = 0.5 (1 + 1/m = 0.5 (1 + 1/4 = 0.790 l 7.0 The angle of inclination is Θ i = Θ 0 α h α m = 1 0.756 0.790 = 0.00298 200 Horizontal forces caused by imperfections: In edge columns H 1 = Θ i P 1 = 0.00298 450 = 1.341 kn, In internal columns H 2 = Θ i P 2 = 0.00298 900 = 2.682 kn. More details referring to the model with fully fixed columns can be found in the article by KNAUFF and KLEMPKA (2009). Bending moments are presented in Figure 3. Example 2 We assumed that the horizontal force caused by wind pressure and suction equals H = 30 kn. We also assumed that the stiff roof construction imposes identical horizontal shifts of the top ends of all the columns. Columns like the ones in example 1 have on each side of their cross section reinforcement 4φ16 (A s = 8.04 cm 2 ) in edge columns and 7φ16 (A s = 14.07 cm 2 ) in internal columns. The calculations were conducted for two cases of loading with longitudinal forces: Case 1 P 1 = 200 kn in edge columns, P 2 = 900 kn in an internal column

Taking Subsoil Susceptibility into Account... 87 Case 2 P 1 = 450 kn in edge columns, P 2 = 790 kn in an internal column. Bending moments for case 1 and 2 are presented in Figure 4 and 5 respectively. The cases show calculations for the soil of small stiffness. Generally, the influence of subsoil susceptibility on bending moments is not very significant. The results for example 2 presented in Figure 5 are an exception. As a result of taking into account the foundation on elastic soil, the bending moments in the edge columns increased by 17% compared to the calculation results for the columns fully fixed to the foundation. a P 1 =200 kn P 2 =900 kn P 1 =200 kn H=30 kn 7.0 2 16.0 b 114.4 210.1 114.4 c 127.0 221.7 127.0 Fig. 4. Example 2- loading for case 1; a) the diagram of the single-storey building, b) bending moments for fully fixed columns [knm], c) moments calculated with subsoil susceptibility [knm]

88 Krzysztof Klempka, Michał Knauff a P 1 =450 kn P 2 =790 kn P 1 =450 kn H=30 kn 7.0 2 16.0 b 157.92 276.58 157.92 c 185.3 309.6 185.3 Fig. 5. Example 2 loading for case 2. a) the diagram of the single-storey building, b) bending moments for fully fixed columns [knm], c) moments calculated with subsoil susceptibility [knm] Conclusions The article presents a method for shaping the support of a column fixed to the foundation on elastic soil. This method may be used in standard computer programmes for static calculations. We presented examples of calculations using the exact method based on the second order analysis and taking into account the nominal stiffness for frames with columns supported in the ways described in the article. Foundation rotation leads to the increase in the final values of moments in the columns, which may be of vital importance in case of fixing columns on soils of small stiffness. Accepted for print 21.06.2010

Taking Subsoil Susceptibility into Account... 89 References Eurocode 2, 2008. Design of Concrete Structures. Part 1-1. General Rules and Rules for Buildings. EN 1992-1-1. FISCHER K. 1965. Beispiele zur Bodenmechanik. Ernst u. Sohn. Berlin. GORBUNOW-POSADOW M.T. 1956. Obliczanie konstrukcji na podłożu sprężystym. Budownictwo i Architektura, Warszawa. KANY M. 1974. Berechnung von Flächengründingen. Ernst u. Sohn. Berlin. KNAUFF M., KLEMPKA K. 2009. Effective lengths of reinforced concrete columns in single-storey frame structures in the light of the Eurocode. Technical Sciences, 12, 71 82. KNAUFF M., KLEMPKA K. 2009. Projektowanie smukłych słupów żelbetowych według Eurokodu 2. Inżynieria i Budownictwo, 12: 663 665. KOBIAK J., STACHURSKI W. 1989. Konstrukcje żelbetowe. T. 3. Arkady, Warszawa. LEWIŃSKI P. 2007. Analiza współpracy żelbetowych zbiorników cylindycznych z podłożem. Wyd. ITB, Warszawa. PN-B-03264: 2002. Konstrukcje betonowe, żelbetowe i sprężone. Obliczenia statyczne i projektowanie.