C146-E209. Headspace Samplers. HS-20 Series

Similar documents
Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Study of Residual Solvents in Various Matrices by Static Headspace

Headspace Technology for GC and GC/MS: Features, benefits & applications

Maximizing Sample Throughput In Purge And Trap Analysis

Analysis. Introduction: necessary. presented. Discussion: As part of be carried. consistent and reliable data. (MoRT) to.

Performance of a Next Generation Vial Autosampler for the Analysis of VOCs in Water Matrices

Protein Sequencer PPSQ-31A / 33A C297-E055B

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

Analysis of Volatile Organic Compounds in Water and Soil by EPA Method 8260 with the Atomx Concentrator/Multimatrix Autosampler

Improved Volatiles Analysis Using Static Headspace, the Agilent 5977B GC/MSD, and a High-efficiency Source

Validation of USEPA Method Using a Stratum PTC, AQUATek 100 Autosampler, and Perkin-Elmer Clarus 600 GC/MS

Validation of USEPA Method Using a Stratum PTC and the New AQUATek 100 Autosampler

Analysis of USP Method <467> Residual Solvents on the Agilent 8890 GC System

INNOVATIVE PRODUCTS, SUPERIOR SUPPORT. Presenter: Anne Jurek, Senior Applications Chemist, EST Analytical

Detection of Volatile Organic Compounds in polluted air by an Agilent mini Thermal Desorber and an Agilent 5975T LTM GC/MS

Residual Solvents in Pharmaceuticals by USP Chapter <467> Methodology

Determination of VOCs by USEPA Method 8260 with Extended Dynamic Range using Fast, Sensitive Capillary GC/MS

A Comparison of Volatile Organic Compound Response When Using Nitrogen as a Purge Gas

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Residual solvents analysis using an Agilent Intuvo 9000 GC system

Analysis of Volatile Organic Compounds in Soil Samples by EPA Method 8260 with The Stratum PTC and SOLATek 72 Multi-Matrix Autosampler

Routine-grade performance of a new static headspace autosampler for the analysis of residual solvents according to USP <467> method

USP<467> residual solvents

System and JUREK ANNE. Introduction: in an in purge and. trap sampling. Discussion: As part of. consistent and reliable data. (MoRT) to.

Analyzing Residual Solvents in Pharmaceutical Products Using GC Headspace with Valve-and-Loop Sampling

A Single Calibration for Waters and Soil Samples Performing EPA Method Anne Jurek Applications Chemist

Spectrophotometer for Life Science. BioSpec-nano C101-E112D

U.S. EPA VOLATILE ORGANICS METHOD USING PURGE AND TRAP GC/MS

Determination of N-Nitrosamines by USEPA Method 521 using Triple Quadrupole Gas Chromatography Mass Spectrometry

Applying the Agilent 5977A MSD to the Analysis of USP<467> Residual Solvents with the 7697A Headspace Sampler and 7890B GC

Optimizing. Abstract: is standardd. procedures. altered to

Using Hydrogen as An Alternative Carrier Gas for US EPA 8260

Fast Analysis of USP 467 Residual Solvents using the Agilent 7890A GC and Low Thermal Mass (LTM) System

Optimal VOC Method Parameters for the StratUm PTC Purge & Trap Concentrator

Analysis of Volatile Organic Compounds Using USEPA Method 8260 and the 4760 Purge and Trap and the 4100 Autosampler

Application. Gas Chromatography February Introduction

A novel approach to the analysis of multivitamin by online supercritical fluid extraction/supercritical fluid chromatography

Analysis of Low Level Volatile Organic Compounds in Air Anne Jurek

Determination of 198 pesticide residues in eggplant using Gas Chromatography tandem Mass Spectrometry/Mass Spectrometry

AUTONOMOUS, REAL TIME DETECTION OF 58 VOCS IN THE PANAMA CANAL

Gas Chromatograph Mass Spectrometer GCMS-TQ8050 C146-E326

Determination of Volatile Organic Compounds in Air

Solid Phase Microextraction of Cyanogen Chloride and Other Volatile Organic Compounds in Drinking Water with Fast Analysis by GC-TOFMS

Validation of USEPA Method 8260C Using Teledyne Tekmar Atomx, and Perkin-Elmer Clarus 600 GC/MS

Roger Bardsley, Applications Chemist; Teledyne Tekmar P a g e 1

VOC Analysis of Water-Based Coatings by Headspace-Gas Chromatography

Methanol Extraction of high level soil samples by USEPA Method 8260C

Application News AD Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS

US EPA Method 8260 with the Tekmar Atomx XYZ P&T System and Agilent 7890B GC/5977A MS

Solid Phase Micro Extraction of Flavor Compounds in Beer

Application Note 116 Monitoring VOCs in Ambient Air Using Sorbent Tubes with Analysis by TD-GC/MS in Accordance with Chinese EPA Method HJ

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Analysis of Fast Moving Consumer Goods (FMCG) using GCMS with static and dynamic headspace (HS)

Optimizing of Volatile Organic Compound Determination by Static Headspace Sampling

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

A Single Calibration Method for Water AND Soil Samples Performing EPA Method 8260

Application Note. Abstract. Introduction. Experimental-Instrument Conditions. By: Anne Jurek

Optimal Conditions for USEPA Method 8260B Analysis using the EST Analytical Sampling system and the Shimadzu GCMS-QP2010s

EPA TO-17 Volatile Organic Compounds

Innovative Thermal Desorption From Agilent Technologies. Vivek Dhyani Application Chemist

Gas Chromatograph Mass Spectrometer GCMS-QP2020 C146-E295A

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

Fusion UV/Persulfate TOC Analyzer

Static Headspace Blood Alcohol Analysis with the G1888 Network Headspace Sampler Application

High Purity Chromasolv Solvents

GAS CHROMATOGRAPHY (GC)

Research of Polychlorinated Biphenyls (PCBs) in Vegetables by GC-MS/MS

GCMS-QP2020. Gas Chromatograph Mass Spectrometer. C146-E295. Printed in Japan XXX

The determination of residual solvents in pharmaceuticals using the Agilent G1888 headspace/6890n GC/5975 inert MSD system Application Note

Forensic Toxicology. Analysis of Ethanol in Blood using Master SHS Static Headspace Sampler and Master GC Gas Chromatograph APPLICATION NOTE

Gas Chromatograph Mass Spectrometer GCMS-TQ8040 C146-E251

Ed George and Anaïs Viven Varian, Inc.

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188

Exploring US EPA Method 524 Purge and Trap Variables: Water Vapor Reduction and Minimizing Cycle Time

Determination of Organochlorine Pesticides and Polychlorinated Biphenyls Using GC/MS/MS Operated in the MRM Mode

Air Monitoring Sorbent Pens. For Environmental and IH Applications

Validation of Environmental Water Methods on One System: Considerations for Sample Volume, Purge Parameters and Quality Control Parameters

Fusion UV/Persulfate TOC Analyzer

Validation of Volatile Organic Compound by USEPA. Method 8260C. Application Note. Abstract. Introduction. Experimental-Instrument Conditions

Application Note. Application Note 081 Innovative Cryogen-Free Ambient Air Monitoring in Compliance with US EPA Method TO-15. Abstract.

Determination of VOC in Artificial Runway by Multiple Headspace Extraction-GC/MS. Gas Chromatography/ Mass Spectrometry APPLICATION.

Single Nano Particle Size Analyzer

A Generic Method for the Analysis of Residual Solvents in Pharmaceuticals Using Static Headspace-GC-FID/MS

Determination of Total Volatile Organic Compounds in Indoor Air Using Agilent 7667A mini TD and 7820A GC

Thermal Desorption Technical Support

Analytical Trap Comparison for USEPA Method 8260C

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188A

Optimizing Standard Preparation

High-sensitivity, high-throughput quantitation of catecholamine metabolites in urine by LC/MS/MS for clinical research

Helium conservation in volatile organic compound analysis using U.S. EPA Method 8260C

Electronic Supplementary Material Experimentally Validated Mathematical Model of Analyte Uptake by Permeation Passive Samplers

AUTOMATED HEADSPACE. Headspace Principles. Graham Broadway. Headspace Gas Chromatography Background to the HS Technique

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Quantitative Determination of Dioxins in Drinking Water by Isotope Dilution using Triple Quadrupole GC-MS/MS

A Comparative Analysis of Fuel Oxygenates in Soil by Dynamic and Static Headspace Utilizing the HT3 TM Automatic Headspace Analyzer

The following report includes the data for the above referenced project for sample(s) received on 5/15/2017 at Air Toxics Ltd.

BECKMAN COULTER QbD1200 Total Organic Carbon Analyzer Critical Measurements Made Simple

AppNote 4/2008. Automated Dynamic Headspace Sampling of Aqueous Samples Using Replaceable Adsorbent Traps KEYWORDS ABSTRACT

Transcription:

C146-E209 Headspace Samplers HS-20 Series

HS-20 Series of Headspace Samplers A Revolutionary System Aimed at Performance and Ease of Use The HS-20 Series is the optimal solution for volatile component analysis. Its superior performance and user-friendly design support all types of analyses, from research to quality control. 1 Excellent Performance High reproducibility Low carryover High-temperature compatibility High reproducibility and low carryover ensure reliable quantitation. In addition, an oven with a maximum temperature of 300 C enables analysis of high-boiling compounds. 2 User-Friendly Design User-friendly sample tray Easy maintenance Easily place samples in the tray with the user-friendly design. Also, the needle, sample loop, trap, and other consumables can easily be replaced from the top of the instrument. 3 Excellent Expandability Electronic cooling trap (trap model) Barcode reader option With the trap model, concentrating the headspace gas enables the analysis of ultra-trace components, such as gases released from parts and materials. The optional barcode reader enables samples to be controlled via a chromatography data system. 2

Excellent Performance High Reproducibility The HS-20 Series achieves high reproducibility through both high-accuracy flow rate control via the pneumatic flow controller (Advanced Flow Control: AFC system) and a mechanism that allows sample vial to enter the oven from the bottom. Consequently, this system minimizes heat loss, and maintains high thermal stability during overlap analyses. Typical HS Sampler Internal heat easily escapes during vial transfer, temporarily reducing the oven temperature. HS-20 Conveyance from the bottom makes it difficult for heat to escape from inside, improving oven temperature stability. (Patent pending) Methanol 50 ppm reproducibility (n = 20) 1.5 % n-butanol 50 ppm reproducibility (n = 20) 1.5 % Low Carryover Keeping the sample line inert and as short as possible results in extremely low carryover. No residue is left, even with acetic acid and other polar compounds, enabling highly reliable analysis. (Patent pending) Vial pressurizing line Acetic acid DMI Loop filling vent line Coffee Blank DMI solvent Blank 7.0 8.0 9.0 10.0 11.0 12.0 min 28.0 28.25 28.5 28.7529.0029.2529.50min Residual acetic acid in coffee < 0.0001 % Residual DMI solvent < 0.0001 % High-Temperature Compatibility With an oven configurable up to 300 C and a simple, inert sample line, the HS-20 Series allows the analysis of high-boiling compounds. Cyclic siloxane is a raw silicone material, trace quantities of which remain in oils, liquid rubber, and other products. Because cyclic siloxane is volatile, it could potentially cause problems with contacts in electronic parts, so controlling its concentration is very important. The HS-20 Series makes it possible to measure everything from cyclic siloxane to phthalate esters under the same conditions. n=5 6 7 8 9 10 11 12 13 14 15 16 Sample warmed to a constant temperature of 300 C Sample warmed to a constant temperature of 220 C Cyclic siloxane C2nH6nOnSin (m/z 73) in resin outgas at 300 C HS-20 Series Headspace Samplers 3

User-Friendly Design User-Friendly Sample Tray The HS-20 sample tray is 20 cm higher than the desk, enabling it to be seen at all times. This makes sample placement easy. In addition, 10 ml and 20 ml vials can be placed and analyzed simultaneously without the need for special attachments. Furthermore, the optional barcode reader allows samples to be controlled using barcodes. Analysis of blood and other samples in the forensic field requires a system that not only offers excellent performance, but also eliminates operational errors. With its user-friendly design, the HS-20 Series prevents mistakes, while the barcode reader records logs to dramatically improve traceability. Quantitative Results Browser The instrument can be controlled by the CFR Part 11-compliant LabSolutions chromatography data system, ensuring traceability of analysis conditions and operations. In addition, an automatic shutdown function operates after analysis is completed, saving electricity and carrier gas. (LabSolutions LC/GC only. Not supported by GCMS software.) Easy Maintenance The HS-20 Series has been designed to enable sample loop and needle replacement and other maintenance work to be performed easily from the top of the instrument. Even if sample lines become contaminated by high-concentration samples, the piping alone can now be replaced. Also, the capillary column joints are shared with the GC sample injection unit, enabling easy column replacement. This superior design minimizes downtime during maintenance and improves laboratory productivity. 4

Excellent Expandability Sample Concentration The HS-20 trap model is equipped with an electronic cooling trap that concentrates the headspace gas, enabling high-sensitivity analysis. By using hydrophobic Tenax, the trap enables the analysis of low-boiling compounds by concentrating them to high-boiling compounds in samples containing moisture. Method files make it easy to switch between trap and conventional modes, in which a sample loop is used. The two modes can be combined even in continuous analysis via batch processing. Electronic Cooling Trap Unit Switching Between Loop Mode and Trap Mode Using Batch Editor 2,4,6-TCA 1ppt TCA in Wine (Loop mode) Area 4 S/N 10 2,4,6-TCA 1ppt TCA in Wine (Trap mode) Area(x100,000) 1.1 1~100ppt 1.0 R 0.998 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0.0 0 10 20 30 40 50 60 70 80 90 Concentration Calibration Curve from TCA Added to Wine (trap mode) High-Sensitivity Analysis of Fragrance Components in Coffee In combination with a GCMS, the high-sensitivity electronic cooling trap enables qualitative and quantitative analyses of fragrance components at trace levels undetectable with a conventional headspace sampler. (x1,000,000) Aceticacid 5.5 5.0 4.5 Pyridine Furfurylalchol 4.0 3.5 Acetol Methylpyrazine Furfurylacetate 3.0 2,5 -Dimethylpirazine 2.5 2.0 Methylfuran 1.5 1.0 Peak areas are improved 5 to 50 times. 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 HS-20Trap + GCMS-QP2010 Ultra HS-20 Series Headspace Samplers 5

Batch Analysis of VOCs in Wastewater With its high thermal stability and inert sample line, the HS-20 Series can measure VOCs in wastewater with high reproducibility. Carryover is minimal, so the sample tray, which is capable of holding 90 samples, can be effectively utilized. IS IS VOC 0.1 ppb reproducibility RSD% (n = 5) 1 3 4 8+9 6 7 5 10 11 14 17 19 20 22 1. 1,1-Dichloroethene 2 Dichloromethane 3 trans-1,2-dichloroethene 4 cis-1,2-dichloroethene 5 Chloroform 6 1,1,1-Trichloroethane 7 Carbon tetrachloride 8 1,2-Dichloroethane 9 Benzene 10 Trichloroethene 11 1,2-Dichloropropane 1.8 3.0 1.4 2.8 2.3 1.7 2.2 2.7 0.7 1.2 3.1 12 Bromochloroethane 2.0 13 cis-1,3-dichloropropane 1.8 14 Toluene 1.4 15 trans-1,3-dichloropropane 1.8 16 1,1,2-Trichloroethane 2.9 17 Tetrachloroethene 0.8 18 Dibromochloromethane 2.1 19 m+p-xylene 1.7 20 o-xylene 1.4 21 Bromoform 2.3 22 1,4-Dichlorobenzene 1.2 2 12 16 13 15 18 21 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 15.0 16.0 Aqueous Solution of USP467 Class 2A/2B Pharmaceutical Residual Solvents In combination with a robust GC detector, the system can be used for quality control requiring high quantitative accuracy. Traceability is guaranteed by the all-sample leak check function and the digitized log function. 12 13 3 4 5 6 7 8 10 11 14 1 2 9 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 min Reproducibility of USP467 Class 2A/2B Procedure A (Aqueous Solution) RSD% (n=20) 2 Acetnitrile 1.1 3 Dichloromethane 1.7 4 trans-1,2-dichloroethene 2.3 5 cis-1,2-dichloroethene 1.9 6 THF 0.6 10 Toluene 2.5 11 Chlorobenzene 2.5 15 22 18 1,2-Dimethoxyethane 3.1 20 Pyridine 2.6 19 21 16 17 18 20 2.5 5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 32.5 35.0 min HS-20 + GC-2010 Plus 6

Specifications and Installa tions Model HS-20 HS-20Trap HS-20LT Transfer line Short (350 C) Short (350 C) Long (200 C) Trap No Yes No HS-20 HS-20Trap Sample Injection Method Number of Vials Vials Vial Mixing Leak Check Optional Barcode Reader Vial Warming Temperature Sample Line Temperature Transfer Line Temperature Trap Trap Cooling Temperature Trap Heating Temperature Carrier Gas Control Vial Pressurized-Gas Control Carrier Gas and Vial Pressurizing Gas PC Interface Control Software Software Operating Environment Guaranteed Operating Environment Power Supply Dimensions Weight Sulfinert sample loop 1 ml (standard); 0.2 ml, 3 ml (optional) or trap (HS-20Trap) 90 Outer dia. 22.5 mm 79 mm (20 ml); outer dia. 22.5 mm 46 mm (10 ml); can be combined 5 stages max. All-vial automatic check Optional, can read 6 types of barcodes Room temperature + 10 to 300 C (Settings are 0 to 300 C, in 1 C units, with an accuracy of ±0.1 C) Room temperature + 10 to 220 C or 150 to 300 C (set in 1 C units, accuracy of ±0.5 C) Long transfer line model (HS-20LT): Room temperature + 10 to 220 C Room temperature + 10 to 350 C (set in 1 C units, accuracy of ±0.5 C) Long transfer line model (HS-20LT): Room temperature + 10 to 200 C Inner dia. 2 mm 100 mm, Sulfinert tube Filler TenaxTA (standard), Carbopack + Carboxene (optional) -30 to 80 C (set in 1 C units, accuracy of ±1 C) For a sample line at 250 to 300 C, room temperature - 30 C For 150 to 250 C, room temperature - 40 C For 150 C or less, room temperature - 50 C 0 to 350 C (set in 1 C units, accuracy of ±1 C) Electronic control via AFC built into GC Electronic control via APC built into GC High-purity helium or nitrogen USB Operates collectively with LabSolutions LC/GC (FDA CFR 21 Part 11 compliant) HSS Control Software is used for GCMS. Windows XP, Windows Vista, Windows 7 (32/64-bit) 15 to 30 C, humidity up to 70 % RH (performance guaranteed at 18 to 28 C with temperature fluctuations within ±1.3 C) 1200 VA max. (HS-20, HS-20LT), 1500 VA max. (HS-20Trap) W553 mm H430 mm D543 mm, excluding PC 33 kg (HS-20, HS-20LT), 40 kg (HS-20Trap) Dimensions (HS-20Trap + GCMS-QP2010 Ultra) units: mm 440 543 1418 HS-20 Series Headspace Samplers 7

HS-20 Series Siltek and Sulfinert are trademarks of Silcotek. Tenax is a trademark of Buchem B.V. Carbopack and Carboxene are trademarks of Supelco. Windows 7 is a trademark of Microsoft Corporation. The symbols (R) and (TM) are not used in this document. Company names, product/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation or its affiliates, whether or not they are used with trademark symbol TM or. Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services. Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own. www.shimadzu.com/an/ For Research Use Only. Not for use in diagnostic procedures. The contents of this publication are provided to you as is without warranty of any kind, and are subject to change without notice. Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication. Shimadzu Corporation, 2012