DWT-10 Instruction Manual

Similar documents
Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

Owner's Manual. for AUTOMATIC LEVEL. NBL Series. FOR CUSTOMER SERVICE, PARTS & REPAIR, CALL Toll Free:

Fig. 1. instrument is in the case

22X Builder s Transit Level Model No Instruction Manual

22X Builder s Level Model No Instruction Manual

Automatic Level NP-732

LT8-300LTU Owner s Guide

CASSINI CQR-120 OPERATING INSTRUCTIONS

取扱説明書 /INSTRUCTION MANUAL 自動レベル /AUTOMATIC LEVEL AT-B2/B3/B4 FC10386-A012-02

FIELD GUIDE FOR HORUS SCOPES

LEAPERS, INC. RED/GREEN DOTS

5-25x56 PMII PSR Illuminated with Double Turn

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

x Builders Level Service Manual

National Optical & Scientific Instrument Inc Tri-County Parkway Schertz, Texas Phone (210) Fax (210)

~.LIETZ ~. LI ETZ INSTRUCTION MANUAL DOUBLE CENTER THEODOLITE TM-20C THE LIETZ COMPANY E. Del Arno Blvd. Carson, Ca (213)

NcSTAR SHOOTER II SERIES SCOPE

GT-510/510L series Instruction Manual

CASSINI CQR-800 OPERATING INSTRUCTIONS INTRODUCTION

Automatic Level Maintenance Manual SAL-XX W/ AIR DAMPENED COMPENSATOR

One-Year Limited Warranty

C A S S I N I TRACKER

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

5-25x56 PMII PSR With Double Turn

INTRODUCTION TO ENGINEERING SURVEYING (CE 1305)

RP-100 TELESCOPE Instruction Manual

Operating Manual 1.1-4x24 Zenith x24 Zenith

WHEN BRIGHTNESS COUNTS

EE 1/3.5х14 U EE 1/3.5х14 U

ZOOM STEREO MICROSCOPE

SURVEYING INSTRUMENTS DT7C DT20C. Electronic Digital Theodolite OPERATOR'S MANUAL

saxon Instruction Manual saxon Grandeur Brass Telescope High quality optics

Melton Series. Owners Manual. Lab Centrifuge. Model # s A C, A C, B C, B C, C C, C C, D C, D C

FOCUS 30/FOCUS 35 Field Calibration with Survey Pro Field Software

RP-200 TELESCOPE Instruction Manual

CAUTION: BEFORE INSTALLATION, CONFIRM THAT THE CROSSBOW IS UNLOADED AND IS IN SAFE OPERATING CONDITION.

model SKT05 SKT05L Toll Free: (855) IMPORTANT: Read Before Using IMPORTANT Lire avant usage IMPORTANTE: Leer antes de usar

Welcome to purchase and use our products and thank you for your confidence in our company s products!

Kalinka Optics Warehouse User Manual Kobra AK Side Mount Red Dot Sight Manual

Dual Red or Green Electronic Dot Sight Instruction Manual

Directions for use

ZFK 4 X 25. Description and Utilization Instructions

Richter Optica. Instructions for Model: S850 Stereo Zoom Microscope

H050 E 97.1.DF.2. Automatic Levels AS-2 / AS-2C

IF YOU NEED ANY FURTHER HELP WITH YOUR GALILEO TELESCOPE PLEASE CALL MON-FRI 9AM - 5PM E.S.COM

product manual H-3220A Benkelman Beam

Flexbar 6.3:1 MANUAL ZOOM STEREO MICROSCOPE. 250 Gibbs Road, Islandia, NY (P) (F)

Telescope. 1. Read these instructions carefully and familiarise yourself with the procedure before assembling the unit.

Cleveland State University

The 36mm Solo R/T Tactical monocular delivers bright images, is compact, easy to handle, and designed for hard use.

WATTS MICROPTIC ALIDADE OPERATING INSTRUCTIONS 20-7

SOLO R/T TACTICAL MONOCULAR

ROMEO ROMEO6 1x30mm FULL SIZE RED DOT SIGHT

1 YEAR LIMITED WARRANTY TELESCOPES

Surveying Instruments. B Series B20 B30 B40. Automatic Levels

SkyScan EWS-PRO - Manual -

Field Pro Operation and Installation Manual

EPOCSELFIR LACITCATiX5T TECHNICAL MANUAL

Carlson CR Robotic/Reflectorless Total Station

STONEX ELECTRONIC THEODOLITE STT SERIES. Instruction Manual

C A S S I N I. MODEL : C EQ3 900mm X 135mm COSMO BRANDS INC.

BINOCULAR. 50 mm Tactical Binocular Manual HD R/T

The Vortex Razor HD Gen II-E 1 6x24 Riflescope

Z650HR SERIES MANUAL ZOOM STEREO MICROSCOPE. 73 Mall Drive, Commack, NY (P) (F)

COMMODORE BRASS TELESCOPE ZHUMELL COMMODORE BRASS TELESCOPE

DT220 DT520 DT520S DT520A DT520AS DT620 DT620S

Instruction Manual Meade 70AZ-T 70mm Compact Refractor Telescope Meade Instruments Corporation

Platinum Series. 6-30x56 Front Focal Plane Scope. with Patent Pending DEKA MIL Reticle. DEKA MIL reticle for unsurpassed accuracy at long range

The 50mm Viper R/T binocular is equipped with the Vortex R/T Ranging reticle, designed to assist the user in calculating distances.

USER MANUAL REFLEX SIGHT. Ultra Shot Plus

product manual H-4204 Proving Ring Penetrometer

Basic Operation Adjust the eyecup

4-14X44 FRONT FOCAL PLANE SCOPE WITH ARC-2 MOA RETICLE

Ambient Weather WS-152B 6" Contemporary Barometer User Manual

ROMEO ROMEO4 1x20mm COMPACT RED DOT SIGHT

10 - Celestron Telescope II: Operation

MC ILLUMINATED USER MANUAL

Second Focal Plane MRAD

ULTRA SHOT PLUS - DARK EARTH REFLEX SIGHT SM26008DE

Altazimuth Mount. Altazimuth Mount

SUGAR/BRIX REFRACTOMETER INSTRUCTION MANUAL

NEVER USE A TELESCOPE TO LOOK AT THE SUN DIRECTLY!

State Unitary Enterprise Production Amalgamation Novosibirsk Instrument-Making Plant PN-6K. Servise Manual

1-6 x 24 Second Focal Plane MOA

C4 PLUS RIFLESCOPES User Guide

Series. Quantum 100 Refractor (Equatorial Mount not included) INSTRUCTION MANUAL models s11160

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

RECON. How to Setup the Telescope to Observe. This guide will show you how to setup your telescope for observing. Written By: Brittany McCrigler

Dual Use: Shooting Tactical / Hunting US Patent 8,166,696 US Patent 7,937,879. Radius Bar. Reticle Focus. Elevation Adjustment Knob

Operating Instructions Validation Tool Kit, KT2 For use with USP Apparatus #1 & #2

The Vortex Razor HD Gen II 1 6x24 Riflescope

HD Gen II 1 6x24 Riflescope. The Vortex Razor

Digital Land Surveying And Mapping(DLS&M) Dr. Jayanta Kumar Ghosh Department of Civil Engineering Indian Institute of Technology, Roorkee

SCHIEBER TELESCOPES. Unique, High-Quality Telescopes

ASTRO-PHYSICS, INC. POLAR ALIGNMENT TELESCOPE

P4Xi TACTICAL Riflescope TECHNICAL MANUAL

Second Focal Plane MOA

Red and Green Dot Sight FF26002 USER MANUAL

Transcription:

DWT-10 Instruction Manual For Customer Service Call (781) 848-7702 or Fax (781) 848-8022

Congratulations on your choice of this David White Electronic Digital Transit. We suggest that you read this instruction manual carefully before using the instrument. By thoroughly familiarizing yourself with the instrument and its operation, you will be able to obtain the full benefit of this superior precision instrument. Save this instruction manual for future use. CONTENTS BEFORE YOU USE... 1 WARRANTY INFORMATION... 2 1. NOMENCLATURE and FUNCTIONS.... 3 1.1 Nomenclature... 3 1.2 Part functions...4 1) Display... 4 2) Operating keys...5 3) Setting up your measuring Preferences... 6 2. PREPARATIONS for MEASUREMENT... 8 2.1 Mounting and leveling... 8 2.2 Telescope eyepiece focus... 9 2.3 Aiming at the target... 10 3. MEASUREMENT... 10 3.1 Power... 10 3.2 Measuring horizontal angles... 11 3.3 Presetting horizontal angles... 11 3.4 Measuring vertical angles... 11 3.5 Measuring percent of grade... 11 3.6 Stadia measurement... 12 3.7 Displayed Error Codes... 12 4. HANDLING of POWER SUPPLY... 13 4.1 Removing battery compartment... 13 4.2 Replacing batteries... 13 4.3 Mounting battery compartment... 13 5. CHECKS and ADJUSTMENTS... 14 5.1 Adjustment precautions... 14 5.2 Checking and adjusting... 14 1) The plate vial... 14 2) The circular vial...14 3) The optical plummet... 15 5.3 Setting the Vertical Zero Position... 15 6. TRIBRACH... 16 7. ACCESSORIES... 16 8. HANDLING PRECAUTIONS... 16 9. SPECIFICATIONS... 17 David White 2002. All Rights Reserved August 2002 Information contained in this publication is subject to change without notice.

IMPORTANT! READ THIS BEFORE USING YOUR INSTRUMENT This quality David White instrument has been inspected twice for accuracy before leaving the factory. The instrument has also been given the best protection possible against damage during transportation. Even with these precautions, the instrument is subject to rough handling during shipment. To protect yourself against the possibility of using an instrument which is out of adjustment, we suggest that you have the instrument checked by a competent person before using it. Note: Please read the manual thoroughly before starting the following test. The following test can be performed to check the instrument s accuracy: Set up the instrument in an area that is about 220 feet long and as level as possible. Place two matching level rods (or drive two pieces of strapping into the ground) about 200 feet apart with the faces toward each other. Position and level the instrument so that the distance from the instrument to each rod is the same (measure; Fig. 1). Take a reading on each rod with the instrument (or mark each piece of strapping where the crosshair is sighted). Note the difference and record them. Next, move the instrument to another point in line with the two level rods as shown in Fig. 2. Level the instrument and take readings on the two level rods (or re-mark the two pieces of strapping with the new crosshair sightings). The differences should be the same ( A - A' should equal B - B'). The difference between A - A' and B - B' is the instrument error at 200 feet. Correction of instrument error should be performed by a competent repair technician. The instrument should be rechecked periodically to assure continued accuracy. 1

WARRANTY David White (Seller) warrants the equipment of its manufacture to be free of defects in workmanship and material for a period of one year from date of purchase. If within such one year period the original purchaser (Buyer) notifies Seller, in writing, that the equipment purchased in not as warranted, and provides a bill of sale, receipt, or other proof as to date of purchase, Seller will, at Seller's option, adjust, repair or replace the whole or any part of the equipment which seller finds to be defective, provided: A. The equipment is returned transportation prepaid to Seller or its designated warranty service center. B. The equipment is in original condition excepting only ordinary wear resulting from normal usage. C. The Seller has received prompt written notification and substantiation that the equipment has been stored, installed, operated and maintained in accordance with the recommendation of the manufacturer and has not been subjected to service by other than Seller or an authorized service center. Warranty service does not include cleaning, oiling, or adjustment of the equipment unless required as a result of a workmanship or material defect in the equipment. If, upon examination of the equipment, the Seller determines that such cleaning, oiling, or adjusting is required other than by reason of the warranty claim, Seller shall notify Buyer of the charges for same and after authorization is received from Buyer, Seller shall perform such additional service(s) on behalf of the Buyer at its standard charges then in effect and the Buyer shall be responsible for the payment of such charges in addition to the other charges and expenses referred to above. In all cases, Buyer is responsible for transportation charges for return of goods from Seller to Buyer. Seller's liability to Buyer (whether in contract or in tort) arising hereunder or as a result of any claimed defect or for any other cause, is hereby expressly limited to correcting the equipment upon the terms and conditions stated above. All liability hereunder shall terminate upon expiration of the applicable warranty period. In no event shall Seller be liable for any loss, expense, or damages direct, indirect, consequential, or special arising from the sale or use of the equipment delivered hereunder. The foregoing warranty states seller's full liability in connection with the purchase of this equipment, accessories, and parts and is in lieu of and supersedes any and all other warranties and representations, if any, express or implied, including merchantability or fitness for purpose, and shall be void if repairs have been made or attempted by persons other than seller's factory personnel or designated authorized service center. This warranty is not transferrable. 2

1. NOMENCLATURE AND FUNCTIONS 1.1 Nomenclature 3

1.2 Part Functions V -8.8.8.8.8.8.8. G HRL8.8.8.8.8.8.8. R L V % HOLD OSET 1.2.1 Display DISPLAY FUNCTION Vertical angle symbol will be shown in place of the vertical reading until the telescope has been turned past the zero point of the horizontal axis. This sets the zero point. V V HR 0.0.0.0.0.0.0. R L V % HOLD OSET (See section 1.2.3, preference set up) HR H L Horizontal angle counterclockwise symbol Horizontal angle clockwise symbol Battery strength symbol (See section 4, power) G % Angular measurements are in gons (See section 1.2.3, preference set up) Vertical reading shown as percent of grade (see section 1.2.3, preference set up) 4

1.2.2 Operating Keys KEY SYMBOL FUNCTION OPERATION R/L Setting horizontal angle rotational direction Used to switch horizontal angle between clockwise rotation (HR) and counterclockwise rotation (H L). The direction changes each time the button is pressed. HOLD Locking horizontal angle reading Used to lock current horizontal angle into display. The horizontal angle reading will flash when this button is pressed. The instrument can be turned without changing the horizontal reading. Pressing the button again will unlock the horizontal angle display. Illuminating the display and the crosshairs Used to light the display and crosshairs. Press to light display and crosshairs, press again to shut off the light. V% Vertical angle to percent of grade Used to switch the vertical angle display between degrees/gons and percent of grade. The % sign will be shown on the display when percent of grade is active. 0SET Zero the horizontal angle reading Used to zero the reading of the horizontal angle display. Press to zero the reading at any point. Power ON/OFF Used to turn the display on and off 5

1.2.3 Setting Up Your Measurement Preferences A) Turn the power on. B) Press R/L and V% at the same time. A tone will be heard and the display should look similar to what s shown at right. 20 360 0 UC C) To specify your measurement preferences: PRESS TO DISPLAY R/L Change the readout of the horizontal and vertical angle display to show 10 second or 20 second readings. (The accuracy of this instrument is 20 seconds, not 10 seconds. Changing the readout does not make the instrument more accurate.) 10 360 b 0 UC V% Change between 360 degree readout or 400 gon readout for horizontal and vertical angle measurement. 10 360 b 0 UC HOLD Change the time of automatic power shut off for the display. The three modes are 0, no auto power off 20,20 minute auto power off 30,30 minute auto power off 10 360 b 0 UC 0SET Change the zero points and angle pattern of the vertical circle. The three modes are Ua, Ub and UC. The following diagrams show the different vertical measurement modes. 10 360 b 0 UC Change between hearing a tone or not when the horizontal angle reads 0º, 90º, 180º, 270º 10 360 b 0 UC 6

1.2.3 Preferences continued Once all preferences have been input, press the H/R and V% at the same time. A long tone will be heard and the display will return to normal. 7

2. PREPARATION FOR MEASUREMENT 2.1 Mounting And Leveling Mount and level the instrument carefully to get the best performance. 1. Place the tripod over the ground datum point and tighten the legs. 2. Attach the instrument to the tripod and tighten snugly 3. Roughly level the instrument with the circular vial A) Use level screws A and B to move the air bubble in the circular vial so it is centered left to right. B) Use level screw C to move the air bubble to the center of the vial. 4. Fine tune level the instrument with the plate level: A) Turn the instrument until the plate level is in either one of the positions shown. Then use the A and B level screws to center the bubble in the level. B) Turn the instrument 90 (100 g) and center the air bubble in the vial using level screw C. C) Repeat steps A and B until the level stays centered in any direction. If the plate level will not stay centered, see section 5.2 to adjust the vial. 8

5. Centering the instrument using the optical plummet A) Adjust the eyepiece so the bull's-eye reticle comes into sharp focus. B) Adjust focus knob so ground target comes into sharp focus. C) Slightly loosen the tripod fastening screw and move the instrument until the ground target is centered in the optical plummet. D) Tighten the tripod fastening screw and recheck the level vials by following steps 3 and 4 again. 2.2 Telescope Eyepiece Focus Point the telescope toward a bright area and turn the telescope eyepiece until the crosshairs come into sharp focus. Avoid parallax, the shifting seen between the target and the crosshairs when your eye moves while sighting through the telescope. Parallax will cause inaccurate measurements. To avoid parallax, perform the following: 1. Focus the telescope on a target. 2. You should be able to move your eye up and down or left and right without seeing the target shift with respect to the crosshairs. 3. If there is parallax, readjust the eyepiece. Always remove any parallax before operation to assure accurate measurements. 9

2.3 Aiming At The Target Loosen the clamps and point at the target using the targeting sights located above and below the telescope. Allow some space between your eye and the targeting sight. 3. MEASUREMENT 3.1 Power 1. Turn the power on. All segments of the display will light for 2 seconds. V -8.8.8.8.8.8.8. G HRL8.8.8.8.8.8.8. R L V % HOLD OSET 2. The vertical reading will then be shown as, which stands for SET V HR 0.0.0.0.0.0.0. R L V % HOLD OSET 3. Rotate the telescope to set the vertical 0 point. This is done to cause the zero pointer to pass a sensor and start vertical angle measurement. V 900000 G HR 00000 R L V % HOLD OSET 4. Check battery power: Full, partial and low power, measurement is possible. No power, no measurement possible; replace the batteries. Full Power Partial Power Low Power No Power Note: Battery operating time will vary depending on type and brand and operating temperature. Be sure to keep an extra set of alkaline type AA batteries in the carrying case. For any other questions about the batteries, see section 4. 10

3.2 Measuring Horizontal Angles 1. Aim at target A 2. Press 0SET key to zero out horizontal angle reading, HR 0 00'00". 3. Aim at second target, B, and the angle between A and B will be displayed, HR 30 15 00". HR shown on the display means that the horizontal angle reading increases as you turn the instrument clockwise. H L shown on the display means that the horizontal angle reading increases as you turn the instrument counterclockwise. 3.3 Presetting Horizontal Angles 1. Turn the instrument until the desired horizontal angle is shown on the display. HR 60 00 00" 2. Press the HOLD button. HR 60 00'00" will blink on and off. 3. Aim the instrument at the target and press the HOLD button again. The horizontal angle will be released from that point. HR 60 00'00" will be the start point for horizontal angle measurement. 3.4 Measuring Vertical Angles There are three different vertical scales to choose from when measuring vertical angles. See the three scales in section 1.2.3., performance setup. Choose the vertical angle mode you wish to use from among the performance setup choices. 3.5 Measuring Percent Of Grade By pressing the V% key, you can switch from vertical angular measurement shown in degrees to percent of grade shown as 0 to 100% slope. The % symbol will be seen on the display next to the vertical reading when in this mode. V%, percent of grade: Any vertical angle exceeding 100% will be shown as "----" on the display. 11

3.6 Stadia Measurements 1. Distance measurement can be done using the stadia hairs of the reticle. 2. Read the length " l " of a level rod shown between the stadia hairs. 3. The distance to the target is 100 multiplied by " l ". The distance between point A and point B is L. L=100 x " l " 3.7 Displayed Error Codes PRESS TO CLEAR DISPLAY CAUSE ERROR E01 Instrument spun horizonitally at too great a speed for the horizontal detector. OSET E02 Telescope spun vertically at too great a speed for the vertical detector. V% E03 Error in the vertical angle measurement system. Re-start the instrument. 2X If error is still shown, return instrument for repair. E04 Error in the horizontal angle measurement system. Re-start the instrument If error is still shown, return instrument for repair. E06 Error in the setting of the vertical zero point. N/A Return instrument for repair. 2X 12

4. HANDLING OF POWER SUPPLY 4.1 Removing The Battery Compartment Push down on the battery compartment latch and pull the top of the battery compartment away from the instrument. 4.2 Replacing Batteries 1. Push down on the hook to remove the metal battery door. 2. Install batteries as shown. 3. Slip the projection shown on the metal battery door into the slot shown and push down on the door until the hook locks the door in place. 4.3 Mounting Battery Compartment 1. Slip the projection on the bottom of the battery compartment into the slot. 2. Push the top of the battery compartment toward the housing until the battery compartment latch clicks into place. 13

5. CHECKS AND ADJUSTMENTS 5.1 Adjustment Precautions When attempting to check and adjust an instrument, corrections must be done in a certain order or the adjustments will not be correct. Order of adjustment: 1. Check and adjust the plate vial. 2. Check and adjust the circular vial. 3. Check and adjust the optical plummet. Always recheck your adjustments. We recommend that any adjustments, other than those shown, be done by a qualified Instrument repair technician. 5.2 Checking And Adjusting 1. The plate vial A) Place the plate vial parallel with the level screws, A and B. Center the bubble using these two level screws. B) Turn the instrument 90 and center the bubble using level screw C. C) Return to the original position in step A. Recheck the bubble and center as necessary. Rotate the instrument 180 (200g). The bubble should still be centered in the vial. If not, go to step D. D) Using the adjusting pin provided in the case, turn the screw until the bubble moves halfway back to its original position. E) Return the instrument to its original position follows steps A through C. Repeat these steps until the bubble stays centered in all positions. 2. The Circular Vial Part 1, adjusting the plate vial, should have been done prior to this step. If the circular vial is centered after leveling the plate vial, then no further adjustment is necessary. If not, proceed with the following adjustment. Using the adjusting pin provided in the case, turn the adjusting screws until the bubble is centered in the vial. DO NOT OVERTIGHTEN THE ADJUSTING SCREWS. Loosen one screw 1/4 turn, then tighten one screw 1/4 turn. 14

3. Optical Plummet This adjustment is required to make the line of sight of the optical plummet coincide with the vertical axis. A) Point the optical plummet at a ground target. This can be done by adjusting the level screws or by loosening the instrument fastening screw and moving the instrument over the target. B) Turn the instrument 180 (200g) around and re-sight the target through the optical plummet. If the target is still centered, no adjustment is necessary. If not, go to step C. C) Remove the adjusting screw cover from the optical plummet. Unscrew in a counterclockwise direction. This will expose four reticle adjusting screws. D) Using the adjusting pin provided in the case, turn the reticle adjusting screws until half the displacement has been removed. Loosen one screw 1/4 turn, then tighten the opposing screw 1/4 turn. E) Repeat steps A through D until there is no displacement of the target when the instrument is turned about its vertical axis 5.3 Setting The Vertical Zero Postion PROCEDURE KEY DISPLAY Accurately level the instrument N/A Press and hold the V% key while pressing the power key. The instrument display will enter the vertical zero adjustment mode. V% V O S E L Turn the telescope past the zero point. The display will show "STEP 1". V L 95 1020 HR S E - - 1 Sight the telescope at a target that is level with the instrument within 10 seconds. Press "V%". This will store the data for the first point. The display will show "SHOW --2". V% V L 95 1020 HR S E - - 2 Reverse the telescope and re-sight the original target. Press the "V%" key. This will store the data for the second point and establish a vertical zero point at level. Once a key is pressed, the instrument will beep and return to regular measurement mode. V% V 2 6 1 1 2 4 3 HR 1 8 0 0 0 0 0 15

6. TRIBRACH Removal: Turn the locking lever 180 counterclockwise. The instrument can now be removed from the tribrach. Attachment: Line up the tongue on the instrument with the notch in the tribrach. Turn the locking lever 180 clockwise. 7. ACCESSORIES Standard Equipment: Carrying case, Sunshade, Tool kit, Rain cover, Drying cloth, Plumb bob Optional equipment: Rechargeable battery, Charger, Tripod, Diagonal eyepiece, Level rod, Solar filter, Triangle tribrach, Solar reticle 8. HANDLING PRECAUTIONS Use care to avoid shock to the instrument. Always provide some cushioning to minimize risk of shock during transportation. The instrument cannot be expected to function properly if exposed to heavy shock. Check the battery indicator. Be sure to check the voltage level before using the instrument. Carrying the instrument. Always remove the instrument from the tripod when carrying at the job site. If the instrument must be carried on the tripod, hold the instrument as vertically as possible and keep it in front of you. Never carry the instrument horizontally over your shoulder. Any long distance transport should be done with the instrument in the carrying case. Do not expose the instrument to direct sunlight for long periods. Never leave the instrument exposed to extreme heat longer than necessary. It could affect the instrument's performance. Store the instrument properly. The instrument should be stored in an area of low humidity and where the temperature will not exceed 110 F (45 C). Always remove the batteries before storing the instrument. Cleaning the instrument. Any dust on the lenses should be removed first with a small brush, then use a lens tissue or soft clean cloth (use a light touch to avoid scratching the lenses). 16 Dry the instrument after use in the rain. Do not use harsh chemicals to clean the instrument or carrying case. A mild detergent or water dampened rag is all that is necessary.

9. SPECIFICATIONS TELESCOPE ELECTRONIC ANGLE MEASUREMENT ILLUMINATION OPTICAL PLUMMET LEVEL VIAL SENSITIVITY DISPLAY OPERATING RANGE Overall Length Objective aperture Magnification Image Field of view Resolving power Minimum focus Stadia Ratio Stadia constant Method Minimum reading Accuracy** Diameter of circle Magnification Field of view Focusing range Plate vial Circular vial Operating voltage required Operating time (Alkaline batteries) Operating Temperature range SIZE 155mm (6.1") 45mm (1.77") 30X Erect 1 30' 2.5" 1.3M (53") 100 to 1 0 Incremental 5"/10" (3/5 mog) 10" (6mog) 82mm (3.22") Display & Reticle 3X 5 0.5 M to infinity (20" to infinity) 30" per 2mm 8' per 2mm 4-6 VDC (4) AA Batteries 15 hrs continuous use @ 20 C (68 F) -20 to +50 C (-4 to +122 F) 145x200x300mm WEIGHT 4.4 Kg inst only 6.8 Kg w/case ** Standard deviation based on DIN18723. 17

P.O Box 359, Watseka, IL 60970 USA (800) 435-1859 (815) 432-5237 FAX (815) 432-5390 www.davidwhite.com P/N DWT10MANL 08/02