Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

Similar documents
PHENOGEL GPC/SEC COLUMNS

Guaranteed * Enhance Resolution FOR POLYMER ANALYSIS, Remarkable Reproducibility Exceptional Efficiency Long Lifetimes Economically Priced

PhenogelTM Non-Aqueous GPC/SEC Columns

Phenogel GPC Materials

Enhance Resolution FOR POLYMER ANALYSIS, Guaranteed *

TSKgel Size Exclusion Chromatography Columns

Solvent-Compatible High Performance GPC Columns: TSKgel HHR Series

A User s Guide to Gel Permeation. Chromatography

Optimizing GPC Separations

Gel Permeation Chromatography Basics and Beyond eseminar March 13, Jean Lane Technical and Applications Support LSCA, Columns and Supplies

GPC-/SEC-Columns. MZ-Gel SD. MZ-Gel Super FG SEC with fluorinated Eluents

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

Practical Steps in GPC Method Development

Quick guide to selecting columns and standards for Gel Permeation Chromatography and Size Exclusion Chromatography SELECTION GUIDE

GPC/SEC standards. Product guide

GPC/SEC standards. Product guide

Organic GPC/SEC columns. Product guide

Size Exclusion Chromatography: Method Development

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Determination of Polymer Modifier in Asphalt

USP <467> Headspace Residual Solvent Assay with a HT3 Headspace Instrument

Polymer analysis by GPC-SEC. Technical Note. Introduction

Headspace Technology for GC and GC/MS: Features, benefits & applications

TECHNICAL NOTEBOOK No.1. GPC LF series columns. Linear calibration curves over a wide molecular weight range. TECHNICAL NOTEBOOK. No.

LC and LC/MS Column Selection Flow Chart

Products for GPC. Products for GPC. Size exclusion chromatography. Basic principles

Product Brief. - Hydrocarbons alkanes, alkenes, alkynes, dienes including natural gas, refinery gas, liquified petroleum gas

LC Technical Information

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Gel Permeation Chromatography - GPC

zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Guide to Choosing and Using Polymer Reversed Phase Columns!

Gel Permeation Chromatography (GPC) or Size Exclusion Chromatography (SEC)

Cation Exchange HPLC Columns

Maximizing Performance Through GPC Column Selection

AGILENT AQUEOUS AND POLAR GPC/SEC COLUMNS

Lecture 4 : Gel Permeation or Size Exclusion Chromatography

Clearing the Confusion: GPC, SEC, GFC What, When, Why, and How?

Introducing New Functionalities in Liquid Stationary Phases in GC Columns for Confirming Organic Volatile Impurity Testing in Pharmaceutical Products.

GPC/SEC Column Selection & Method Development

for Acclaim Mixed-Mode HILIC-1 Column

The Determination of Residual Solvents in Pharmaceuticals Using the Agilent G1888 Network Headspace Sampler Application

ProPac WCX-10 Columns

Prelab Reading Assignment: Laboratory Techniques in Organic Chemistry, 4 th Ed. Chapter 19

Aqueous and polar GPC/SEC columns. Product guide

GPC/SEC An essential tool for polymer analysis

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

Shodex TM ODP2 HP series columns

The Theory of HPLC. Normal Phase (Absorption) Chromatography

Tube O Reactor. (Micro: Cat. # K, K, K) (Medi: Cat. # K, K, K)

No.106. Aqueous SEC Columns for Analysis of Cationic Polymers: TSKgel PWXL-CP Series. Contents. Page

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

EPA TO-17 Volatile Organic Compounds

GPC / SEC Theory and Understanding

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

Chemical Compatibility Guide and Life Expectancy for the SolVac Filter Holder

Glove Selection Chart

SPE Introduction. general chromatography. solid phase extraction. How to Choose an SPE Product. Solid-Phase Processing Methods

Study of Residual Solvents in Various Matrices by Static Headspace

Chiral separations efficient, fast and productive

GPC - Gel Permeation Chromatography. aka Size Exclusion Chromatography- SEC

Lab 3: Solubility of Organic Compounds

High Performance Liquid Chromatography

Analytical Trap Comparison for USEPA Method 8260C

Ferdowsi University of Mashhad

Hypercrosslinked Gel-type Polystyrene Resin. Applications Guide

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Chem 230, Fall, 2014 Homework Set # 3 Short Answer SOLUTIONS

Liquid storage: Holds the solvent which is going to act as the mobile phase. Pump: Pushes the solvent through to the column at high pressure.

Chemistry 3200 High Performance Liquid Chromatography: Quantitative Determination of Headache Tablets

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

Method Development Kits

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Polymer Analysis by Gel Permeation Chromatography

Thermal Desorption Technical Support

Analysis of Residual Solvents in Pharmaceuticals (USP<467>) with Shimadzu GC-2010 Plus and HS-10 Headspace Sampler

Molecular Weight Distribution of Living Chains in Polystyrene Pre-pared by Atom Transfer Radical Polymerization

Optimizing. Abstract: is standardd. procedures. altered to

Target Compound Results Summary

Physical Polymer Science Lecture notes by Prof. E. M. Woo adapting from: Textbook of Physical Polymer Science (Ed: L. H.

Low molecular weight resins Analysis of low molecular weight. resins and prepolymers by GPC/SEC. Application compendium. Authors

Water Injections in GC - Does Water Cause Bleed?

Simultaneous dual capillary column headspace GC with flame ionization confirmation and quantification according to USP <467> Application Note

GPC/SEC Start-up Kit

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

US EPA Method with the Tekmar Lumin P&T Concentrator, AQUATek LVA and Agilent 7890B GC/5977A MS

Column Selection for Size Exclusion Chromatography (SEC)

Solid Phase Micro Extraction of Flavor Compounds in Beer

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Sepax SRT -C, Zenix -C SEC Phases

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

10/27/10. Chapter 27. Injector typically 50 C hotter than oven

COMPLIANCE EMISSIONS TEST California Dept. of Public Health Standard Method Version 1.1 and FloorScore Flooring Evaluation

Multi-Prep and Detectabuse Columns and 96 Well Deep-Well Plates for Sample Preparation

CALIBRATING GPC COLUMNS


Open Column Chromatography, GC, TLC, and HPLC

Transcription:

phenogel Gpc/sec columns HPLC 5 and 10 μm particle sizes Narrow bore (4.6 mm ID) solvent-saver to preparative columns available Very good alternative to Polymer Labs PLgel and Waters Styragel, Ultrastyragel, Styragel HT, and Styragel HR columns Highly cross-linked for mechanical and chemical stability Temperature stable to 140 C Phenogel is available in seven different pore sizes ranging from 50 Å to 10 6 Å, and a linear bed configuration. Pore size distribution and pore volume are closely controlled parameters in the manufacturing process; accounting for the high resolution, tight linear calibration curves and excellent column-to-column reproducibility. Sample Elution Each standard dimension Phenogel column (300 x 7.8 mm) has an internal volume of 15 ml that is distributed as follows: 3 ml is occupied by the solid portions of the gel particles (20 % of total column volume) 6 ml is the pore volume of the packing material (40 % of total column volume) 6 ml is the interstitial volume or volume between the gel particles (40 % of total column volume) Thus, about 6 ml of solvent must elute through each column before even the largest molecules can emerge, while the smallest molecules emerge with the total column volume of 12 ml. This constant distribution of volume makes it possible to predict the amount of solvent and time necessary to complete any analysis. SEM Photos of Phenogel Polymer Beads Technical Specifications Material: SDVB Particle Size: 5, 10 μm Porosities: 50 Å to 10 6 Å, and mixed beds Typical Pressure: 5 μm: 350 psi 10 μm: 200 psi Maximum Pressure: 650 psi Maximum Temperature: 140 C Minimum Efficiency*: 5 μm: 45,000 p/m** 10 μm: 35,000 p/m** Typical Flow Rates: 4.6 mm ID: 0.35 ml/min 7.8 mm ID: 1.0 ml/min 21.2 mm ID: 8.0 ml/min End Fittings: Valco Compatible * Tested in THF ** For 300 x 7.8 mm ID columns See note on p. 381 regarding pore sizes and exclusion limits Column Molecular Weight Calibration Curves Polystyrene Molecular Weight Elution Volume/Column (ml) 10 3 Å 10 6 Å Column Selection by Molecular Weight Sample Type Molecular Weight Phenogel Column Small Organics 100-3 K 500-6 K 1 K - 15 K 50 Å 100 Å 500 Å Resins 1 K - 75 K 5 K - 500 K 10 K - 1,000 K 10 3 Å 10 4 Å 10 5 Å High MW Polymers 60 K - 10,000 K 100-10,000 K 10 6 Å Linear(2) 224 Phenomenex

Solvent and Temperature Compatibility Phenogel columns are packed in tetrahydrofuran (THF) Columns can also be shipped in solvents such as DMF, Methylene Chloride, NMP, and o-cp, to help minimize equilibration time Solvent Compatibility Table Mobile Phase Solvent N = Not Compatible Y = Compatible Phenogel Pore Size: (Å) 50 100 500 10 3 10 4 10 5 10 6 Mixed Linear & Suggested Operating Temp. Acetone Y Y Y Y Y Y Y Y Benzene Y Y Y Y Y Y Y Y Carbon Tetrachloride Y Y Y Y Y Y Y Y Chloroform Y Y Y Y Y Y Y Y 30 % HFIP/Chloroform Y Y Y Y Y Y Y Y Diethyl Ether Y Y Y Y Y Y Y Y Dimethylacetamide (DMAC) Y* Y Y Y Y Y Y Y 60 C Dimethylformamide (DMF) Y* Y Y Y Y Y Y Y 60 C Dioxane Y Y Y Y Y Y Y Y DMSO Y* Y Y Y Y Y Y Y 60 C Ethyl Acetate Y Y Y Y Y Y Y Y Hexafluoroisopropanol (HFIP) Y Y Y Y Y Y Y Y Hexane Y Y Y Y Y Y Y Y M-Cresol Y* Y Y Y Y Y Y Y 100 C Methyl Ethyl Ketone Y Y Y Y Y Y Y Y Methylene Chloride Y Y Y Y Y Y Y Y 0-Chlorophenol Y* Y Y Y Y Y Y Y 100 C 0-Dichlorobenzene Y* Y Y Y Y Y Y Y 135 C Quinolin Y* Y Y Y Y Y Y Y 60 C Tetrahydrofuran Y Y Y Y Y Y Y Y Toluene Y Y Y Y Y Y Y Y Trichlorobenzene Y* Y Y Y Y Y Y Y 135 C Water N N N N N N N N Xylene Y Y Y Y Y Y Y Y *Not recommended on 5 μm 50 Å columns. Solvent Switching Considerations Although Phenogel columns are rugged and can withstand strong solvent changes, care should be exercised when switching from high-swell solvents (A) to low-swell solvents (B, C, and D). Improper solvent switches can result in a void. Best results are attained when an intermediate-swell solvent is used, and column lifetime is improved. Contact Phenomenex regarding solvents not listed below. Column life can be maximized by dedicating certain columns to certain solvents. This will also minimize solvent switches. If care is not taken, a void may occur. Reduce flow rate to 0.2 ml/min Backpressure must NEVER exceed 650 psi Always check solvent miscibility in a beaker or follow the solvent miscibility table on page 379 before proceeding with ANY solvent switch. Compare the swell characteristics of solvent 1 (old solvent) to solvent 2 (new solvent) and use the following guidelines: -- If solvent 1 and solvent 2 belong to the same swell category (see table below), check the solvent miscibility and proceed with the switch. -- If solvent 1 and solvent 2 belong to successive swell categories as indicated by the arrows in the table below, check the miscibility and proceed with the switch. -- If solvent 1 and solvent 2 DO NOT belong to the same OR successive swell categories, switch to an intermediate solvent FIRST, as indicated by the arrows in the table. HPLC phenogel Gpc/sec columns Phenomenex 225

50 Å - 10 6 Å Columns High resolution at low cost Customize your analysis by coupling different pore-size columns Wide range of solvent compatibility Polymethyl Methacrylates (Wide MW Range) Column: Phenogel 5 μm 10 5 Å, 10 4 Å, 10 3 Å, 500 Å Sample: 1. 700,000 MW 2. 107,000 MW 3. 27,000 MW Closely Related Hydrocarbons Column: Phenogel 5 μm 50 Å, 100 Å, 500 Å Sample: 1. C40 562 MW 2. C32 450 MW 3. C24 338 MW 4. C20 282 MW 5. C16 226 MW 6. C13 184 MW phenogel Gpc/sec columns HPLC Rel Inten X10-1 14.00 12.00 10.00 8.00 6.00 4.00 2.00 App ID 5429 0.00 App ID 5430 App ID 5431 App ID 5432 Polyethylene Glycol 330 Column: Phenogel 5 μm 50 Å, 100 Å, 500 Å Sample: 1. dp7 546 MW 2. dp6 458 MW 3. dp5 370 MW 4. dp4 282 MW 1 Refrac Chromatogram 2 3 4 5. dp3 194 MW 6. dp2 106 MW 7. dp1 62 MW 5 6 7 App ID 5433 Phenolic Resins Column: Phenogel 5 μm 500 Å x 2, 10 3 Å, 10 4 Å Detection: RI Injection Volume: 5 µl Temperature: 25 C Sample: Phenolic Aldehyde Resin, MW 500 to 470 K 20.00 21.00 22.00 23.00 24.00 25.00 26.00 27.00 Ret Vol (ml) Organic Compounds Column: Phenogel 10 μm 100 Å Dimensions: 250 x 21.2 mm Part No: 00G-0642-P0 Mobile Phase: Dichloromethane Flow Rate: 4.0 ml/min Detection: UV @ 254 nm Sample: 1. Diethylhexyl Phthalate 2. Biphenyl 3. Naphthalene 4. Coronene 5. Sulfur Polyvinyl Butyral Column: Phenogel 5 μm 500, 10 3, 10 4, 10 5 Å Temperature: 25 C Sample: 300,000 MW App ID 5438 226 Phenomenex

50 Å - 10 6 Å Columns (cont'd) Polyethylene Oxide (PEO) Column: Phenogel 10 μm 10 5, 10 4, 10 3 Å Mobile Phase: DMF (0.1 M LiBr) Injection Volume: 100 µl 0.125 % w/v Temperature: 50 C Sample: 1. 400,000 MW Polystyrenes (Wide MW Range) Column: Phenogel 10 μm 10 5, 10 4, 10 3 Å Mobile Phase: THF Injection Volume: 100 µl 0.125 % w/v Sample: 1. 1,560,000 MW 5. 6,100 MW 2. 260,000 MW 6. 845 MW 3. 94,000 MW 7. 146 MW 4. 30,000 MW App ID 5434 Isoprenes from In Vitro Translation on Products Column: Phenogel 5 μm 50 Å, 100 Å in series Mobile Phase: THF Flow Rate: 0.25 ml/min Sample: 1. Squalene C30 (2, 6, 10, 15, 19, 23-Hexamethyltetracosane) 2. Phytane C20 (2, 6, 10, 14-Tetramethylhexadane) 3. Farnesne C15 (2, 6, 10-Trimethyldodecane) 1 2 Polybutadines (Wide MW Range) Column: Phenogel 5 μm 10 5, 10 4, 10 3, 500 Å Sample: 1. 420,000 MW 2. 24,000 MW 3. 2,500 MW 4. 500 MW App ID 5437 App ID 5435 HPLC phenogel Gpc/sec columns 45 50 55 min The columns were used in tandem to characterize isoprene chain lengths removed from labeled in vitro translation products or cell proteins. The isoprenoids were removed by treatment with Raney nickel and extracted into pentane. The pentane extractable material was hydrogenated over platinum catalyst and injected onto the column. Fractions were collected at 0.5 minute intervals and radioactivity was monitored by liquid scintillation. These saturated hydrocarbon chains were characterized by comparing radioactive peaks to standard retention times. Chromatogram courtesy of W. Maltese and R. Erdman, Weis Center for Research, Geisinger Clinic. 3 App ID 5436 Poly-(α-Methyl Styrene) (Wide MW Range) Column: Phenogel 5 µm 10 5, 10 4, 10 3, 500 Å Sample: 1. 680,000 MW 2. 90,000 MW 3. 30,000 MW 4. 6,000 MW 1 2 3 4 App ID 5439 0 10 20 30 40 min Phenomenex 227

Linear Columns Linear calibration to 10 million daltons Long column life Excellent mechanical stability Excellent for analyzing a wide range of molecular weights Cyclic Polymer Characterization Column: Phenogel 10 μm Linear(2) Dimensions: 600 x 7.8 mm Part No.: 00K-3260-K0 Mobile Phase: THF with 1 % TEA Flow Rate: 1.3 ml/min Detection: UV @ 268 nm Injection Volume: 40 µl 0.2 % w/v Sample: Poly-(2-Vinylpyridine) [0.05 % - 0.25 % (w/v)] Calibration Curve: Linear (2) - Phenogel 5 μm 300 x 7.8 mm 10 8 10 7 10 6 10 5 phenogel Gpc/sec columns HPLC MW 10 11 12 Crude Fractionated 13 14 15 16 17 18 Elution Vol (ml) Narrow Bore Columns An Improved Dimension in GPC Analysis Decrease solvent consumption App ID 5441 10 4 10 3 10 2 10 1 y = 4.47e + 11 R = 0.99 4 5 6 7 8 9 10 11 min Retain same elution profile Reduce solvent disposal costs Phenogel-NB (NarrowBore) columns are optimized to reduce solvent consumption. The Phenogel-NB columns have a 4.6 mm column ID and run at 0.35 ml/min, reducing solvent consumption and disposal costs up to 65 %! Loading With narrow bore GPC/SEC columns, the volume in which the sample elutes is significantly decreased, thus increasing the effective concentration of the sample. This increase in sensitivity is exploited in HPLC, but in GPC it leads to overloading effects and proportionally lower sample loadings must be used. 10 3 10 4 10 5 10 6 10 7 228 Phenomenex

Ordering Information 5 μm Columns (mm) Guards 300 x 7.8 600 x 7.8 300 x 21.2 50 x 7.8 Pore Size MW Range 50 Å 100-3 K 00H-0441-K0 03B-2088-K0 100 Å 500-6 K 00H-0442-K0 00K-0442-K0 03B-2088-K0 500 Å 1K-15 K 00H-0443-K0 03B-2088-K0 10 3 Å 1K-75 K 00H-0444-K0 03B-2088-K0 10 4 Å 5K-500 K 00H-0445-K0 00K-0445-K0 00H-0445-P0 03B-2088-K0 10 5 Å 10K-1,000 K 00H-0446-K0 00K-0446-K0 00H-0446-P0 03B-2088-K0 10 6 Å 60K-10,000 K 00H-0447-K0 00H-0447-P0 03B-2088-K0 300 x 7.8 600 x 7.8 50 x 7.8 Mixed Beds Linear(2) 100-10,000 K 00H-3259-K0 00K-3259-K0 03B-2088-K0 If Phenogel analytical columns do not provide at least equivalent separation as compared to a competing column of the similar particle size, phase, and dimensions, send in your comparative data within 45 days and keep the column for FREE. Other Shipping Solvents: Methanol, Methylene Chloride, Cyclohexane, Ethyl Acetate, NMP, DMAC, DMF Size (mm) Price 30 x 4.6 $ 75 50 x 4.6 75 300 x 4.6 125 300 x 7.8 150 600 x 7.8 200 300 x 21.2 250 600 x 21.2 470 NOTE: Phenogel columns are routinely shipped in THF. Columns can be shipped in Toluene and Chloroform upon request at no additional charge. 5 μm Narrow Bore (NB) Columns (mm) Guards 300 x 4.6 30 x 4.6 Pore Size MW Range 50 Å 100-3 K 00H-0441-E0 03A-2088-E0 100 Å 500-6 K 00H-0442-E0 03A-2088-E0 500 Å 1K-15 K 00H-0443-E0 03A-2088-E0 10 3 Å 1K-75 K 00H-0444-E0 03A-2088-E0 10 4 Å 5K-500 K 00H-0445-E0 03A-2088-E0 10 μm Columns (mm) Guards 300 x 7.8 600 x 7.8 300 x 21.2 600 x 21.2 50 x 7.8 Pore Size MW Range 50 Å 100-3 K 00H-0641-K0 00K-0641-K0 00H-0641-P0 00K-0641-P0 03B-2090-K0 100 Å 500-6 K 00H-0642-K0 00K-0642-K0 00H-0642-P0 00K-0642-P0 03B-2090-K0 500 Å 1K-15 K 00H-0643-K0 00K-0643-K0 00K-0643-P0 03B-2090-K0 10 3 Å 1K-75 K 00H-0644-K0 00K-0644-K0 00H-0644-P0 00K-0644-P0 03B-2090-K0 10 4 Å 5K-500 K 00H-0645-K0 00K-0645-K0 00H-0645-P0 00K-0645-P0 03B-2090-K0 10 5 Å 10K-1,000 K 00H-0646-K0 00K-0646-K0 00H-0646-P0 00K-0646-P0 03B-2090-K0 10 6 Å 60K-10,000 K 00H-0647-K0 00K-0647-K0 00H-0647-P0 00K-0647-P0 03B-2090-K0 300 x 7.8 600 x 7.8 300 x 21.2 50 x 7.8 Mixed Beds Linear(2) 100-10,000 K 00H-3260-K0 00K-3260-K0 00H-3260-P0 03B-2090-K0 Phenogel Columns are a Recommended Alternative to: Manufacturer Columns Jordi Associates Jordi GPC-DVB Polymer Labs PLgel Waters Styragel µstyragel Ultrastyragel Styragel HT Styragel HR HPLC phenogel Gpc/sec columns For full line of Polymer Calibration Standards, see p. 358 For Column Heaters, see p. 343 All other column dimensions available. Phenogel columns are routinely shipped in THF. However, columns are also available in commonly used solvents such as Toluene and Chloroform as well as DMF, NMP, and other solvents. Refer to the chart above for the additional charge for these shipping solvents. Please specify shipping solvent when ordering. Phenomenex 229