zorbax Packed by Phenomenex Material Characteristics High efficiency Guaranteed quality Phenomenex columns packed with Zorbax

Similar documents
New Product Update. HPLC Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Zorbax. Catalogue 9. Hichrom Limited

LC and LC/MS Column Selection Flow Chart

Orosil HPLC Columns. OroSil HPLC columns are designed for the separation of polar, semi-polar, and nonpolar compounds at low to medium ph.

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

QUALITY HPLC COLUMNS PARTICLE PORE PAGE SIZE SIZE. C18 Bidentate C18 Extremely long column life and rugged 4um 100Å 3

Packings for HPLC. Packings for HPLC

Sepax SRT -C, Zenix -C SEC Phases

LC Column Troubleshooting. Do you have an equivalent column for my LC column?

Hamilton. Reversed-Phase Anion Exchange Cation Exchange Ion Exclusion

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Choosing Columns and Conditions for the Best Peak Shape

ACE Ultra Inert Base Deactivated HPLC Columns

ProntoSIL C18-EPS Reversed-Phase HPLC Columns

ACE Excel SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

Method Development Kits

Optimisil HPLC & UPLC Column catalogue

ChromegaChiral TM CSP Media and Columns

HPLC Column Material - Bulk Ware

penta-hilic UHPLC COLUMNS

mau 200 ph min

HICHROM. Chromatography Columns and Supplies. LC COLUMNS Vydac. Catalogue 9. Hichrom Limited

A Look at Column Choices. Ed Kim Application Engineer Agilent Technologies, Inc February 12, 2009

LC Technical Information

Efficiently analyze your most challenging compounds. Deliver high-quality results faster. Agilent ZORBAX Column Selection Guide for HPLC

Bringing uhplc Performance to the Separation of Peptides

Thermo Scientific Accucore XL HPLC Columns. Technical Manual

Shodex TM ODP2 HP series columns

William E. Barber, Ph.D. Applications Chemist October

New 5-micron HALO-5 columns based on Fused- Core particle technology boost the performance of HPLC. Compared to other HPLC columns, HALO-5 columns

ACE SuperC18. ACE UHPLC and HPLC Columns. Ultra-Inert UHPLC and HPLC Columns with Extended ph Stability

COMPARISON GUIDE. to C18 Reversed Phase HPLC Columns. Comparison Data on 60 Commonly Used C18 Phases. Stationary Phase Specifications

CHROMTECH - CHIRAL HPLC COLUMNS

State-of-the-art C18 HPLC Columns

How proteins separate on reverse-phase HPLC

Your Reversed Phase Method

Improve Peak Shape and Productivity in HPLC Analysis of Pharmaceutical Compounds with Eclipse Plus C8 Columns Application

Chiral separations efficient, fast and productive

A Look at Agilent HPLC Columns Choices

Alltech Alltima HP Introduction

Gemini-NX Performance paired with Axia Technology

ChromegaChiral TM CSP Media and Columns

Logical Method Development for Peptides and Proteins Using RP-HPLC and SEC

Packed Column for Ultra-Fast Reversed-Phase Liquid Chromatography, TSKgel Super-ODS. Table of Contents

HICHROM. Chromatography Columns and Supplies. LC COLUMNS HALO and HALO-5. Catalogue 9. Hichrom Limited

Guide to Choosing and Using Polymer Reversed Phase Columns!

An HPLC column offering moderate retentivity with superb peak shape Inertsil ODS Sprint

Comparison Guide to C18 Reversed Phase HPLC Columns

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

for Acclaim Mixed-Mode HILIC-1 Column

CLIPEUS - A Small Shield for a Big Job

ACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development

SRT -10/10C (10 µm ) Fast Protein Purification For FPLC, HPLC and Prep LC. Sepax Technologies, Inc. Preparative Size Exclusion Chromatography

penta-hilic UHPLC COLUMNS

Peptide and protein analysis by capillary HPLC Optimization of chromatographic and instrument parameters. Application. Angelika Gratzfeld-Huesgen

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Too Polar for Reversed Phase What Do You Do?

Phenyl-Hexyl. UHPLC Columns. Alternate, complementary selectivity to C18 and C8 bonded phases

Gemini. Second-Generation TWIN-NX Technology. TWIN (Two-In-One) Technology. U.S. Patent No. 7, 563, 367 Setting the Standard for ph Method Development

Part 2. Overview of HPLC Media

Optical Isomer Separation Columns and Packing Materials

High Performance Liquid Chromatography

High Performance Liquid Chromatography

A C18 Silica Column With Exceptional Temperature and ph Stability

Put the. C18 aside. and take a look... Reasons. to try the. NEW Gemini C6-Phenyl

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Passion. Power. Productivity.

Chemistry Instrumental Analysis Lecture 28. Chem 4631

InertSustainSwift C8

Ion Exchange Columns ---- Inertsil AX 078 Inertsil CX 080. HPLC Column Catalog

HPLC UHPLC Columns. Dikma Technologies Inc.

ACE C18-PFP. Hydrophobic and pentafluorophenyl mixed mode interaction. High efficiency 2µm, 3µm, 5µm and 10µm particles for UHPLC and HPLC

Epic Aromatic Selectivity

Setting the Standard for ph Method Development

Sample Preparation TLC Plates

N α - 1 k. R s = Figure 1: The effect of N, α and k on resolution (Rs)

Validated HPLC Methods

Phenogel. GPC/SEC Columns. Sample Elution. Technical Specifications 10 3 Å 10 6 Å

8. Methods in Developing Mobile Phase Condition for C18 Column

Hypersil BDS Columns TG 01-05

( )( ) Selectivity Choices in Reversed-Phase Fast LC. Introduction. R s = 1 a 1 k 4 a 1 + k

Kromasil. for your analytical HPLC. Kromasil. The way to peak performance in liquid chromatography

Advantages of polymerbased. an alternative for ODS

Capital HPLC Columns and HPLC Cartridges. Optimal HPLC Range

PHENOGEL GPC/SEC COLUMNS

Acclaim Mixed-Mode WCX-1

TCI Chiral HPLC Column

ProntoSIL HPLC Columns

LIQUID CHROMATOGRAPHY

Acclaim AmG C18 Column

6 Optical Isomer Separation Columns

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Do you need trouble-free speed? The NEW Chromolith HR

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

AGGREGATE ANALYSIS. Biologics Workflow. by Size Exclusion Chromatography

Kromasil Eternity Designed for long life

35 % OFF HPLC. The Ultimate Guide to

Kromasil Eternity Designed for long life. For use in HPLC and UHPLC

Do you need trouble-free speed? The NEW Chromolith HR

Transcription:

Packed by Phenomenex High efficiency Guaranteed quality Phenomenex columns packed with 7 μm materials offer the advantages of lower cost as well as lower operating backpressures, which result in long column lifetimes. f any Phenomenex-packed column does not provide equal or better results than other manufactured columns using material of 7 μm particle size with the same phase and comparable dimensions, return the column with comparative data within 4 days for a full refund. Material Characteristics Calculated Packing Particle Pore Surface Carbon Bonded Phase End Material Shape/Size Size Area Load Coverage Capping (μm) (Å) (m /g) % (μmole/m ) ODS Spher. 3,, 7 70 300 0, Monomeric 3.47 Yes C8 Spher. 3,, 7 70 300, Monomeric.99 Yes CN Spher. 3,, 7 70 300 7, Monomeric.4 Yes App D 69 Reversed Phase Test Mix Column: 7 μm ODS Dimension: 0 x 4.6 mm D Part No.: 00G-0088-E0 Solvent: Acetonitrile/Water (7:) Flow Rate:. ml/min Pressure: 800 psi Detection: UV @ 4 nm njection Size:.0 μl Sample:. Benzamide. Benzene 3. Benzophenone 4. Biphenyl 4 3 Ordering nformation SecurityGuard Cartridges require universal holder Part No.: KJO-48 7 µm Columns (mm) SecurityGuard Cartridges 0 x 4.6 0 x 4.6 4 x.0 mm 4 x 3.0 mm Phases Silica 00F-0086-E0 00G-0086-E0 /0pk AJ0-4347 /0pk AJ0-4348 C8 00F-0087-E0 00G-0087-E0 AJ0-489 AJ0-490 ODS 00F-0088-E0 00G-0088-E0 AJ0-486 AJ0-487 CN 00F-0089-E0 AJ0-4304 AJ0-430 for D:.0-3.0 mm 3.-8.0 mm Other column dimensions available upon request. 68 Phenomenex

Extend and Bonus RP also available. Please call and inquire. SB Rx XDB Traditional Ultron-Chiral Material Characteristics Packing Particle Pore Surface Carbon End Material Shape/Size Size Area Load Capping (μm) (Å) (m /g) (%) ODS Spher. 3,,7 70 300 0 yes C8 Spher. 3,,7 70 300 yes Phenyl Spher. 3,,7 70 300 yes CN Spher. 3,,7 70 300 7 yes TMS Spher. 70 300 4 yes NH Spher.,7 70 300 4 no Silica Spher. 3,,7 70 300 no* Rx C8 Spher. 3.,,7 80 80 no* Rx C8 Spher. 3.,,7 80 80. no* SB-C8 Spher. 3.,,7 80 80 no* SB-C8 Spher. 3.,,7 300 4.8 no* SB-C8 Spher. 3.,,7 80 80. no* SB-C8 Spher. 3.,,7 300 4. no* SB-Phenyl Spher. 3.,,7 80 80. no* SB-CN Spher. 3.,,7 80 80 4 no* SB-CN Spher. 3.,,7 300 4. no* SB-C3 Spher. 3.,,7 80 80 4 no* SB-C3 Spher. 3.,,7 300 4. no* XDB-C8 Spher. 3., 80 80 7.6 yes** XDB-C8 Spher. 3., 80 80 9. yes** * sterically protected (no end-capping) ** double end-capped Eclipse XDB 80 Å reversed phase columns Easy method development Symmetrical peaks Wide usable ph range Eclipse XDB columns are available as Eclipse XDB-C8 and Eclipse XDB-C8. The Eclipse XDB-C8 column will provide very high retention for many polar and non-polar compounds. Eclipse XDB-C8 columns are excellent for initial method development because they provide excellent retention and selectivity for mixtures of polar and moderately polar compounds. ORDERNG NFORMATON Eclipse XDB Columns Column μm Size (mm) XDB-C8 (L) XDB-C8 (L7) Price 0 x 4.6 990967-90 990967-906 0 x 4.6 993967-90 993967-906 Rapid Resolution 3. 0 x 4.6 963967-90 963967-906 Rapid Resolution 3. 7 x 4.6 966967-90 Solvent Saver Plus 3. 0 x 3.0 96394-30 Narrow-Bore 0 x. 993700-90 Narrow-Bore LC/MS 0 x. 960967-90 960967-906 Guard Cartridge (4pk). x 4.6 8090-9 8090-96 Guard cartridges require a reusable hardware kit, Part No. 80888-90. (see ordering information on p. 7) Phenomenex 69

StableBond Low ph stability High temperature stability Great for the analysis of basic compounds StableBond (SB) columns provide low ph stability because they are made from patented, sterically-protecting silanes. The diisobutyloctadecylsilane (SB-C8) and diisopropylsilanes (SB-C8, SB-Phenyl, SB-C3, and SB-CN) are less susceptible to loss of the bonded phase by acid hydrolysis than traditional dimethylsilanes providing high column lifetime under these harsh conditions. Monolayer bonding with these bulky silanes results in a high degree of reproducibility from column lot-to-lot. StableBond columns are available with five different bonded phases to provide many choices for achieving good resolution during method development. ORDERNG NFORMATON StableBond columns are designed for optimal use at low ph. At ph 6-8, column stability is obtained by operating at temperatures <40 C using low buffer concentrations in the range of 0.0-0.0 M. StableBond 80 Å Columns Column μm Size (mm) SB-C8 (L) SB-C8 (L7) SB-CN (L0) SB-C3 SB-Phenyl (L) Price 0 x 4.6 88097-90 88097-906 88097-90 88097-9 0 x 4.6 88397-90 88397-906 88397-90 88397-909 88397-9 Rapid Resolution 3. 0 x 4.6 86393-90 86393-906 86393-90 86393-9 Rapid Resolution 3. 7 x 4.6 86693-90 86693-906 86693-90 86693-9 Solvent Saver 0 x 3.0 88097-306 Solvent Saver Plus 3. 0 x 3.0 86394-306 86394-3 Narrow-Bore 0 x. 883700-9 883700-906 883700-90 883700-9 Narrow-Bore LC/MS 0 x. 86097-90 86097-90 Semi-Preparative 0 x 9.4 88097-0 88097-0 Preparative 7 0 x. 8770-06 Guard Cartridge (4pk). x 4.6 8090-90 8090-9 8090-96 8090-97 Preparative Guard 7 x 9.4 8067-8067- 8067- Cartridge (pk) Guard cartridges require a reusable hardware kit, Part No. 80888-90 (see ordering information on next page). Preparative guard cartridge columns require a reusable hardware kit, Part No. 84040-90 (see ordering information on next page). StableBond 300 Å Excellent lifetime with TFA containing mobile phases Wide-pore (300 Å) columns for high molecular weight analytes Multiple selectivities for proteins and peptides Wide-pore, StableBond 300SB-C8, 300SB-C8, 300SB-CN, and 300SB-C3 columns provide high efficiency and complementary selectivities for optimized separations of proteins and peptides. All StableBond columns are monolayer bonded to high purity silica for reproducibility and excellent peak shape, a necessity for basic peptides and proteins. Four different bonded-phases are available for excellent resolution without compromising column stability. ORDERNG NFORMATON StableBond 300 Å (Wide-Pore) Columns Column μm Size (mm) 300SB-C8 300SB-C8 300SB-CN 300SB-C3 Price 0 x 4.6 88099-90 88099-906 88099-90 88099-909 0 x 4.6 88399-90 88399-906 88399-90 88399-909 Rapid Resolution 3. 0 x 4.6 863973-90 863973-906 863973-90 863973-909 Rapid Resolution 3. 0 x 4.6 86973-90 86973-90 Narrow-Bore 0 x. 88370-90 88370-906 88370-90 88370-909 Semi-Preparative 0 x 9.4 88099-06 Guard Cartridge (4pk). x 4.6 8090-9 8090-98 8090-93 8090-94 Guard cartridges require a reusable hardware kit, Part No. 80888-90 (see ordering information on next page). 70 Phenomenex

Ordering nformation RX Series Rx 80 Å Reversed-Phase Columns Column μm Size (mm) Rx-C8 (L) Rx-C8 (L7) Price 0 x 4.6 880967-90 880967-90 0 x 4.6 883967-90 883967-90 Rapid Resolution 3. 0 x 4.6 863967-90 86393-906 Rapid Resolution 3. 7 x 4.6 866967-90 86693-906 Solvent Saver 0 x 3.0 88097-306 Narrow-Bore 0 x. 883700-906 Semi-Preparative 0 x 9.4 880967-0 880967-0 Preparative 7 0 x. 8770-06 Guard Cartridge (4pk). x 4.6 8090-94 8090-93 Preparative Guard 7 x 9.4 8067-8067- Cartridge (pk) Traditional Reversed Phase Traditional Reversed-Phase Columns Column μm Size (mm) ODS C8 (L) C8 (L7) Phenyl (L) CN (L0) TMS (L3) Price 0 x 4.6 8809-70 8809-706 8809-7 88490-07 8809-70 0 x 4.6 8839-70 8839-706 8839-7 88490-6 Special 3 0 x 4.6 88490-43 Semi-Preparative 0 x 9.4 8809-0 Guard Cartridge (4pk). x 4.6 8090-90 8090-906 8090-90 Preparative Guard 7 x 9.4 8067-8067- 8067- Cartridge (pk) Normal Phase Normal Phase Columns Column μm Size (mm) Rx-SL (L3) SL (L3) CN (L0) NH (L8) Price 0 x 4.6 88097-90 8809-70 8809-70 8809-708 0 x 4.6 88397-90 8839-70 8839-70 8839-708 Semi-Preparative 0 x 9.4 8809-0 Guard Cartridge (4pk). x 4.6 8090-90 8090-908 Guard cartridges require a reusable hardware kit, Part No. 80888-90 (see ordering information below). Preparative guard cartridge columns require a reusable hardware kit, Part No. 84040-90 (see ordering information below). 3 Non-endcapped Reusable Hardware Kits Kit Part No. Price Guard Hardware Kit* 80888-90 Preparative Guard Hardware Kit 84040-90 * Guard Hardware Kit includes guard column holder (), guard endfitting (), column connector (). Upgrade for old Part No. 80777-90. Compatible with all guard cartridges. Preparative Guard Hardware Kit includes inlet fitting (), Teflon coated endfitting (), and a column connector (). All hardware components are available separately as replacement parts. See p. 68 for Phenomenex packed columns. Phenomenex 7

Rapid Resolution Columns StableBond Eclipse XDB Rx StableBond 300 Å The need for new column configurations to increase productivity is growing rapidly. Rapid Resolution columns use 3. μm particles to provide high efficiency in a short column. The result is a time and solvent savings of up to 60 %. The 0 mm Rapid Resolution column has 8,000-0,000 theoretical plates the same as a 0 mm column packed with μm particles. The 7 mm Rapid Resolution columns are comparable to 0 mm, μm columns. Rapid Resolution columns are also available in 300 Å pore-size for the separation of high molecular weight molecules (>4000), such as peptides and proteins. ORDERNG NFORMATON Rapid Resolution Columns Column μm Size (mm) Pore Size Part No. Price Rx-C8 3. 0 x 4.6 80 Å 863967-90 Rx-C8 3. 7 x 4.6 80 Å 866967-90 SB-C8 3. 0 x 4.6 80 Å 86393-90 SB-C8 3. 7 x 4.6 80 Å 86693-90 SB-C8 3. 0 x 4.6 80 Å 8397-90 SB-C8 3. 0 x 4.6 80 Å 86393-906 SB-C8 3. 7 x 4.6 80 Å 86693-906 SB-C8 3. 0 x 4.6 80 Å 8397-906 SB-CN 3. 0 x 4.6 80 Å 86393-90 SB-CN 3. 7 x 4.6 80 Å 86693-90 SB-CN 3. 0 x 4.6 80 Å 8397-90 SB-Phenyl 3. 0 x 4.6 80 Å 86393-9 SB-Phenyl 3. 7 x 4.6 80 Å 86693-9 Eclipse XDB-C8 3. 0 x 4.6 80 Å 963967-90 Eclipse XDB-C8 3. 7 x 4.6 80 Å 966967-90 Eclipse XDB-C8 3. 0 x 4.6 80 Å 963967-906 300SB-C8 3. 0 x 4.6 300 Å 863973-90 300SB-C8 3. 0 x 4.6 300 Å 86973-90 300SB-C8 3. 0 x 4.6 300 Å 863973-906 300SB-CN 3. 0 x 4.6 300 Å 863973-90 300SB-CN 3. 0 x 4.6 300 Å 86973-90 300SB-C3 3. 0 x 4.6 300 Å 863973-909 Ultron ES Chiral Columns* Two complementary protein-based chiral stationary phases Easy to use with reversed-phase mobile phases Racemic separation without derivatization Specifically designed chiral stationary phases are an excellent choice for the separation of enantiomers without derivatization. These constitute a growing number of drug substances of interest. The Ultron ES-OVM columns contain an ovomucoid protein covalently bonded to μm silica particles with 0 Å pores. Both columns are easy to use since they separate enantiomers using reversed-phase, predominantly aqueous mobile phases. The Ultron ES-OVM column can be used over the ph range 3-7. and can separate both acidic and basic compounds. The Ultron ES-Pepsin column will better resolve many compounds the ES-OVM column may not, and is excellent for separation of basic compounds because of the lower isoelectric point of pepsin. ORDERNG NFORMATON Ultron ES Chiral Columns Column μm Size (mm) ES-OVM ES-Pepsin Price 0 x 4.6 706 86 & Guard 0 x 4.6 706A 863A *Ultron Chiral columns are manufactured by Shinwa Chemical ndustries, Ltd. **See p. 08 for additional Chiral Stationary phases. 7 Phenomenex