Research Gamma Counter

Similar documents
The Multi-Wiper HE. High Energy Nuclear Medicine Well Counter. The first multi-well counters designed specifically for Nuclear Medicine!

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

Wiper Gold Edition. Premium Wipe Test Counter. Setting the bar higher

1 of :32

1/5 Specifications Hidex 300 SLL automatic TDCR liquid scintillation counter

ɣ-radiochromatography

LS6500 Scintillation Counting Systems

Hidex 300 SL Automatic TDCR Liquid Scintillation Counter

2100TR Liquid Scintillation Counter

An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science Research.

Quantum Series Product Catalog

4- Locate the channel number of the peak centroid with the software cursor and note the corresponding energy. Record these values.

1220 QUANTULUS The Ultra Low Level Liquid Scintillation Spectrometer

Alpha spectrometry systems. A users perspective. George Ham. 26 th May Date Month Year

RADIATION-METER TM-91/TM-92

SCINTILLATION DETECTORS & GAMMA SPECTROSCOPY: AN INTRODUCTION

A Study of Radioactivity and Determination of Half-Life

AFT. Advanced Friction Tester. Static and dynamic coefficient of friction Fast, repeatable measurements Compliant to multiple standards

ß + RADIATION. Choose your application of. chromatography controlled. chemical purity TLC PET GABI. PET GABI 2x2 Nal (Tl) 0 1V output.

Detection and measurement of gamma-radiation by gammaspectroscopy

WM2018 Conference, March 18-22, 2018, Phoenix, Arizona, USA. PVT and LaBr3(Ce)-based Radon Express Analyzers 18164

New happenings in gamma spectroscopy data analysis Sylvie Ward Sales Support Specialist

QuantumMCA QuantumNaI QuantumGe QuantumGold

IdentiFINDER Digital Hand Held Spectrometer & Dose Rate Meter for Portable Applications

LABORATORY VIII NUCLEAR PHENOMENA

Alpha-Energies of different sources with Multi Channel Analyzer

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

The Plus for your lab!

Analyze... Cheese. Ice Cream. Sour Cream. Yogurt. Butter. Margarine. Deboned Poultry. Beef. Condiments. Cookies. Crackers. Snack Foods. and more...

January 2002 INSTRUMENT MANUAL 1470 WIZARD. Gamma Counter

FRAM V5.2. Plutonium and Uranium Isotopic Analysis Software

J R. TransTech Systems T S. The World s Number 1 Supplier Of Non Nuclear Density Meters for Asphalt Pavements and Engineered Soils

JAPAN QUALITY. Automated Clinical Analyzer

Characterization of Large Structures & Components

A new chapter. medicacorp.com

GAMMA RAY SPECTROSCOPY

Quality Assurance. Purity control. Polycrystalline Ingots

BOXA-II ON-STREAM X-RAY FLUORESCENCE ANALYZER. Technical Description Version 2 BGRIMM AUTOMATION

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

JAPAN QUALITY. Automated Clinical Analyzer

DIGITAL PULSE SHAPE ANALYSIS WITH PHOSWICH DETECTORS TO SIMPLIFY COINCIDENCE MEASUREMENTS OF RADIOACTIVE XENON

THE COMPTON EFFECT Last Revised: January 5, 2007

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

IRMS. perspective. Isotope Ratio Mass Spectrometry.

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

MASS ATTENUATION COEFFICIENT OF LEAD


LIQUID SCINTILLATION COUNTERS. {Beta Counters}

Alpha-energies of different sources with Multi Channel Analyzer (Item No.: P )

FoodScreen Radiological Food Screening System

ICP-MS. High Resolution ICP-MS.

Drug Testing Solutions INDIKO DRUG TESTING ANALYZER. 1 P F

K 40 activity and Detector Efficiency

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

NEW! Your bacteria s favorite! Eppendorf Eporator

The Clinical Chemistry System that offers more so you do less!

TL6 Ultra Micro-volume Spectrophotometer

ORTEC AN34 Experiment 10 Compton Scattering

Design and production of Scintillation Detectors

RADEAGLET. Lightweight Handheld Radioisotope Identification Device

Lab 14. RADIOACTIVITY

Radiation Detection. 15 th Annual OSC Readiness Training Program.

Automated Clinical Analyzer

CHEMISTRY 170. Radioisotopes

Effect of Co-60 Single Escape Peak on Detection of Cs-137 in Analysis of Radionuclide from Research Reactor. Abstract

610,- KERN ADB. Analytical balances. Quick-Finder Analytical balances. Large glass draught shield with 3 sliding doors

GM Pancake Probe Victoreen Model D

Ion-Chamber Survey Meter OD-02

MetConsole AWOS. (Automated Weather Observation System) Make the most of your energy SM

RESULTS YOU CAN COUNT ON

Ultra-Low Background Measurement Capabilities At SNOLAB

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

Gamma-Spectrum Generator

WM 07 Conference, February 25 March 01, 2007, Tucson, AZ

Fast, Effective XPS Point Analysis of Metal Components

Scintillation Detector

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Shielded NaI(Tl) γ-ray Spectrometer with High-Precision Spectrum Analysis

473-SHX Dew Point Mirror

Moisture Analyzers.

Validation of detection efficiency of alpha particles in commercial liquid scintillation counters

Radiation Detection and Measurement

The RX-6000 Sulfur in Oil Analyzer For the analysis of Sulfur in Oil and other elements from S to U

ONYX -MCE MULTI-CHANNEL OPTICAL FIBER PYROMETERS WITH ACTIVE EMISSIVITY COMPENSATION PRECISION TEMPERATURE MEASUREMENT FOR DEMANDING INDUSTRIAL

arxiv:nucl-ex/ v2 21 Jul 2005

SIMPLICITY AND TECHNOLOGY THE LIASYS CLINICAL CHEMISTRY SYSTEMS FOR PHYSICIAN OFFICE LABORATORIES

Efficiency. Calculations for Selected Scintillators. > Detector Counting. Efficiency. > Photopeak Efficiency of Various Scintillation Materials

PRODUCTS FOR EDUCATION AND TRAINING

CALYS 120 IS. ATEX documenting multifunction calibrator with high accuracy 0.006%

COMPARATIVE STUDY BETWEEN EXTERNAL STANDARD METHOD AND INTERNAL STANDARD METHOD FOR LOW-LEVEL TRITIUM MEASUREMENTS

Unit 2. Instrumentation. Experts Teaching from Practical Experience

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Your Partner in Environment Monitoring

MARINELLI BEAKERS CATALOG

Advanced lab course for Bachelor s students

PERSPECTIVE STABLE ISOTOPE RATIO MS

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies AUTOMATED QA/QC CHECK

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Transcription:

Research Gamma Counter

Multi-Detector Gamma Counters High performance gamma counters for RIA and research applications Complete data reduction for all RIA, IRMA, Radio and Research assays Selectable dual label counting Automatic calibration for long term stability Quality Control storage Decay corrected stored curves 8 sizes 1,2,3,4,5,6,8 and 10 well models Well-type NaI(tl) detectors 4096 channel analyser for unmatched accuracy and spectral plotting Multiple interface ports Count high energy isotopes with full crosstalk correction (Cr51,Fe59,etc.) Self diagnosing of system parameters Extremely compact Specification Detectors Well-type NaI(tl) crystals(s) coupled to high gain PMT. Available in 1,2,3,4,5,6,8 and 10 well models. Background Less than 45cpm for I125 window. Analyser 4096 channels with automatic dead time correction (for high count samples). Well Liner Removable plastic well liners prevent detector contamination. Display High resolution, backlite LCD for maximum reliability. Printout The Genesys Genii comes complete with an 80 column, compact graphics printer, or choose to connect another printer. Dimensions 1-5well: 46cm x 27cm x 34cm. (30-34kg) 6-10well: 51cm x 27cm x 34cm. (38-41kg).

Data Reduction Curvefits: Point to Point, Weighted Straight Line, Straight Line, Cubic Spline. Graph Paper: Linear-Linear, Semi-Log, Logit-Log. Response Variables: CPM, %B/Bo, %CPM/HiSTD, K x (CPM/REF1). The power to calculate any RIA, IRMA, Ratio, screening or research assay. Calibration Simply insert a single or matched set of Co57 sources into the counter, touch automatic calibration and the Genesys Genii does the rest. High voltage, zero, dead time and linearity are automatically calibrated. Assay Printout Get protocol details, graphics and easy to understand assay and Q.C. printouts via the graphics printer. Quality Control Analysis Quality Control software provides storage for the last 30 assay runs.

Higher Energy Gamma Counters High Efficiency Counting for Energetic Isotopes Large, 2 x 2 inch well-type NaI(tl) detectors Choice of 1,2 or 3 detector models User selectable counting windows up to 2 Mev Exclusive E-Lead eliminates crosstalk in multi-well units High energy gamma counter Heavy lead shielding reduces background levels to increase sensitivity and lower the limit of detection. Data Reduction Specification Detectors Well-type, 50mm x 50mm NaI(tl) 1,2 or 3 detector models. Background Less than 40 CPM for Cs137 Window. Analyser 4096 channels with automatic dead time correction (for high count samples). Well Liner Removable plastic well liners prevent detector contamination. Display High resolution, backlite LCD for maximum reliability. Printout The Genesys Genii comes complete with an 80 column, compact graphics printer, or choose to connect another printer. Dimensions 1-3well: 46cm x 27cm x 34cm. (30-34kg).

Single Detector RIA Gamma Counter Performance you would expect from an expensive multi-well counter Data Reduction for all RIA, IRMA, Screening and Ratio assays Simultaneous dual label counting saves time (count Folate/B12 once) Automatic high voltage gain adjustment avoids costly service calls Complete system self diagnostics View isotope spectra directly and avoid contamination and spilldown errors Well-type NaI(tl) detector for higher efficiency through-hole detectors; >80% (shorter count time) LCD display of curves, spectra, etc. saves paper and costly reports Recall counts automatically-stores last assay run in memory Compact size Affordable Specification Detector Well-type NaI(tl) crystal coupled to high gain PMT. Shielding 20mm virgin lead. Keypad Alpha numeric. Dimensions Base Unit - 27cm W x 22cm D x 25cm H. Detector - 15cm D x 25cm H. (14.5kg).

Other LabLogic products & services Service & Support Users of our instrumentation can benefit from our comprehensive, fully inclusive instrument service and support. We provide complete service and support for all of our customers to give reassurance that if things go wrong, help is only an e-mail or phone call away. Service. Support. Reassurance. Validation Services We believe that nobody knows and understands our systems and the needs of the nuclear medicine laboratory better than we do, which is why we have put together our Validation Service to enable you to implement and get maximum value from your investment as quickly as possible. We work as a partner with your System Manager and users to provide a tailored Validation Plan suited to your needs. Our Validation Specialists incorporate years of experience in GLP system validation, detailed knowledge of our systems, together with other industry standard systems to help you meet your Company's requirements. Industry Specialists. For other instruments in our range please visit our website: www.lablogic.com Europe LabLogic Systems Limited, Paradigm House, 3 Melbourne Avenue, Broomhill, Sheffield, England, S10 2QJ, U.K. E-mail: solutions@lablogic.com Tel: +44 (0) 114 266 7267 Fax: +44 (0) 114 266 3944 www.lablogic.com USA & Canada LabLogic Systems, Inc. East Pointe Park, 1040 East Brandon Blvd. Brandon, FL 33511-5509 E-mail: sales@lablogic.com Tel: +1-813-626-6848 Tel: +1-800-875-INUS (4687) Fax: 813-620-3708 Design by bluestrawberryelephant.co.uk 2011.