The AccuTOF -DART 4G: The Ambient Ionization Toolbox

Similar documents
1) In what pressure range are mass spectrometers normally operated?

Chemistry Instrumental Analysis Lecture 37. Chem 4631

M M e M M H M M H. Ion Sources

Lecture 15: Introduction to mass spectrometry-i

Mass Spectrometry. Electron Ionization and Chemical Ionization

Chemistry Instrumental Analysis Lecture 34. Chem 4631

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Mass Spectrometry. General Principles

Direct Analysis in Real Time (DART) A New Ionization Technique

JWH-018 and JWH-022 as Combustion Products of AM2201

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

LC-MS Based Metabolomics

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

TANDEM MASS SPECTROSCOPY

Welcome to Organic Chemistry II

Other Methods for Generating Ions 1. MALDI matrix assisted laser desorption ionization MS 2. Spray ionization techniques 3. Fast atom bombardment 4.

Ionization Techniques Part IV

Mass Spectrometry (MS)

Chapter 25: The Chemistry of Life: Organic and Biological Chemistry

Propose a structure for an alcohol, C4H10O, that has the following

Application Note FTMS-56 Reproducibility of Crude Oil Characterization by Flow Injection APPI-FT-ICR Mass Spectrometry

AN INTEGRATED SYSTEM USING TEMPERATURE BASED SAMPLING FOR POLYMER CHARACTERIZATION

Identification of Marker Compounds in Herbal Drugs on TLC with DART-MS

CHEM 241 UNIT 5: PART A DETERMINATION OF ORGANIC STRUCTURES BY SPECTROSCOPIC METHODS [MASS SPECTROMETRY]

In recent weeks, there have been a number of reports

Electrospray Ion Trap Mass Spectrometry. Introduction

Molecular Mass Spectrometry

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

3 Use of Mass Spectra to Obtain Structural Information

Planar chromatography meets direct ambient mass spectrometry: current trends

Chem 1075 Chapter 14 Solutions Lecture Outline

CEE 772: Instrumental Methods in Environmental Analysis

CHAPTER A2 LASER DESORPTION IONIZATION AND MALDI

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

IDENTIFICATION OF ORGANOMETALLIC COMPOUNDS USING FIELD DESORPTION IONIZATION ON THE GCT

Mass Spectrometry. Introduction EI-MS and CI-MS Molecular mass & formulas Principles of fragmentation Fragmentation patterns Isotopic effects

Mass spectrometry and elemental analysis

HPLC solvents and mobile phase additives

Chemistry 311: Topic 3 - Mass Spectrometry

INTRODUCTION TO MASS SPECTROMETRY Instrumentation, Applications and Strategies for Data Interpretation

DART Presentation. Brian Musselman BioCop & Confidence Workshop April th ICT Prague

National Institute of Standards and Technology, Materials Measurement Science Division, Gaithersburg, MD,USA. *

Characterization of petroleum samples via thermal analysis coupled to APCI FTMS

An EZ-DART spectrum was taken for both fifty (SI figure 2a) and twenty (figure 3 and

ABI 3200 Q TRAP LC/MS/MS System

Prima PRO Process Mass Spectrometer

CHAPTER 8 ISOLATION AND CHARACTERIZATION OF PHYTOCONSTITUENTS BY COLUMN CHROMATOGRAPHY

Structural Determination Of Compounds

CEE 772: Instrumental Methods in Environmental Analysis

CEE 772: Instrumental Methods in Environmental Analysis

Ionization Methods in Mass Spectrometry at the SCS Mass Spectrometry Laboratory

Chapter content. Reference

Introduction. Chapter 1. Learning Objectives

Applying the Technology of the TurboMatrix 650 ATD to the Analysis of Liquid Accelerants in Arson Investigation

Analysis of Pressure Sensitive Adhesives by GC/MS and GC/AED with Temperature Programmable Pyrolyzer

High-Speed Gas and Headspace Analysis for the Process-Line and Laboratory: SIFT- MS IFPAC 2017

Chapter 13 Alkenes and Alkynes Based on Material Prepared by Andrea D. Leonard University of Louisiana at Lafayette

Translational Biomarker Core

HYDROCARBONS: STRUCTURE & PROPERTIES

PSI Chemistry. 3) How many electron pairs does carbon share in order to complete its valence shell? A) 1 B) 2 C) 3 D) 4 E) 8

Mass Spectrometry - Background

air protection technology

Chem 1075 Chapter 19 Organic Chemistry Lecture Outline

Mass Spectrometry. A truly interdisciplinary and versatile analytical method

EXPT. 7 CHARACTERISATION OF FUNCTIONAL GROUPS USING IR SPECTROSCOPY

Chapter Four: Laboratory Characterisation of the Aerodyne Aerosol Mass Spectrometer

Mass Spectrometry: Introduction

Part of the n.m.r. spectrum of butanone is shown on the axes below chemical shift/

Qualitative Organic Analysis CH 351 Mass Spectrometry

Analytical Methods Accepted Manuscript

L.7. Mass Spectrum Interpretation

MASS and INFRA RED SPECTROSCOPY

Adsorption Processes. Ali Ahmadpour Chemical Eng. Dept. Ferdowsi University of Mashhad

Role of Water and Phase in the Heterogeneous Oxidation of Solid and Aqueous Succinic Acid Aerosol by Hydroxyl Radicals

Infrared Spectroscopy: Identification of Unknown Substances

An ion source performs the following two functions:

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

15.04.jpg. Mass spectrometry. Electron impact Mass spectrometry

More information can be found in Chapter 12 in your textbook for CHEM 3750/ 3770 and on pages in your laboratory manual.

Advanced Pharmaceutical Analysis

Chapter 21: Hydrocarbons Section 21.3 Alkenes and Alkynes

Experiment 1: Thin Layer Chromatography

Supporting Information. Corporation, 1-1 Kurosakishiroishi, Yahatanishi-ku, Kitakyushu , Japan

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Stabilization of a Reactive Polynuclear Silver Carbide Cluster through the Encapsulation within Supramolecular Cage

BIOCHEMISTRY GUIDED NOTES - AP BIOLOGY-

Lecture 8: Mass Spectrometry

BIOB111 - Tutorial activities for session 8

F324: Rings, Polymers & Analysis Spectroscopy

Lecture 8: Mass Spectrometry

Mass Spectrometry in MCAL

Experiment 5 Reactions of Hydrocarbons

is given for the isotopic fingerprinting methodology.

Olumide Adebolu. Chromatographic Fidelity and Matrix /Analyte Solubility in Complex Polymer Systems using HPLC-MALD/I TOF MS

Development of VUV-SPI-TOFMS Instrument for the Detection of Polycyclic Aromatic Hydrocarbons

Introduction to GC/MS

Introduction to Organic Chemistry: Hydrocarbons

Organic Compounds. Introduction to Organic Chemistry: Hydrocarbons. also contain other nonmetals such as oxygen, nitrogen,

Determining the Structure of an Organic Compound

Transcription:

The AccuTOF -DART 4G: The Ambient Ionization Toolbox Introduction JEOL introduced the AccuTOF-DART in 2005 as the first commercially available ambient ionization mass spectrometer system. The atmospheric pressure ionization interface (API) for the AccuTOF system, originally designed as a simple, rugged and reliable LC/MS interface, became the ideal platform for developing the Direct Analysis in Real Time (DART) ion source. Because the DART ion source can be positioned directly in front of the AccuTOF sampling orifice without additional interface hardware, a variety of ambient ionization techniques are available to the AccuTOF-DART operator without removing the DART ion source. The third-generation AccuTOF-DART 4G system is an ambient ionization toolbox that allows the analyst to choose ionization methods that are best matched to the samples to be analyzed. DART The DART ion source can be operated on the AccuTOF-DART 4G in several different modes to provide complementary information about substances to be analyzed. Helium DART: moderately polar small molecules In positive-ion mode, helium DART [1] generally produces protonated molecules [M + H] + for compounds with a basic site, a heteroatom, or a site of unsaturation. In negative-ion mode, helium DART produces deprotonated molecules [M H] - for compounds such as carboxylic acids or phenols that have a labile proton. Samples are introduced directly into the DART gas stream. By heating the helium gas, DART can detect volatile and semi-volatile compounds. Compounds with a molecular weight below 1000 can generally be detected by helium DART. Some compounds with molecular weights in excess of 2000 can be detected if they are sufficiently volatile. Figure 1. Positive-ion helium DART mass spectrum showing additives in a synthetic motor oil. JEOL USA, Inc. 2016 www.jeolusa.com Page 1

O 2 - attachment: nonpolar molecules (alkanes, alcohols) Some compounds, including saturated alkanes and alcohols do not readily undergo proton transfer reactions. These compounds can be analyzed with the DART ion source by forming adducts with oxygen anions [2]. For this experiment, samples in solution are aspirated directly into the sampling orifice of the AccuTOF atmospheric pressure interface while the DART is operated in negative-ion mode as a source of O 2. Rapid expansion into vacuum cools the weakly bound [M + O 2 ] species for detection by the AccuTOF. Rel. Intensity % 100 50 Compounds detected as [M + O 2 ] Dialkyldiphenylamines Alkylnaphthalene C28 C30 C32 C34 C36 C40 C42C44 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 m/z Figure 2. Negative-ion O 2 attachment DART mass spectrum of the motor oil from Figure 1, showing the base oil components including C24-C44 alkanes and an alkylnapthalene. Dopant-assisted argon DART: molecular ions and proton transfer Argon DART is more selective than helium. Because the internal energy of Ar * is 11.55 ev, water is not ionized. Only compounds with a low ionization energy are detected. Charge transfer or proton transfer reactions can be induced by adding a dopant such as acetone, methanol, toluene, fluorobenzene or chlorobenzene [3, 4]. Dopant-assisted argon DART can complement helium DART by producing molecular ions for compounds such as polynuclear aromatic hydrocarbons (PAHs), and may reduce fragmentation and enhance protonation for labile compounds. Figure 3. Argon DART mass spectrum showing molecular ions for lycopene and other compounds in a hexane extract of ketchup. JEOL USA, Inc. 2016 www.jeolusa.com Page 2

Pyrolysis DART: industrial materials, polymers Although high-molecular-weight materials such as industrial polymers cannot be detected intact by DART, increasing the DART heater to 350 C or higher can result in degradation to produce characteristic fingerprint fragments. Figure 4. Pyrolysis DART mass spectra of three polymers obtained with helium gas and the DART gas heater set to 350 C. Note: Thermal desorption/pyrolysis DART: even better for materials and polymers A thermal desorption/pyrolysis stage (The Biochromato, Inc. IonRocket ) is designed for use with DART. Highly reproducible thermal desorption profiles show outgassing, additives, and high-quality pyrolysis DART mass spectra for materials. Thermal desorption/pyrolysis analysis of duct tapes and fibers is discussed in separate application notes. JEOL USA, Inc. 2016 www.jeolusa.com Page 3

Inlet ionization: Polar molecules including peptides and medium-sized proteins Inlet ionization [5] complements DART by allowing the operator to analyze polar and charged compounds. The sample can be aspirated directly from solution into orifice 1, or a matrix (3-nitrobenzonitriile) can be added to induce ionization. Figure 5: Solvent-assisted inlet ionization of naphthol blue black dye. FilterSpray TM : Polar molecules and elemental analysis FilterSpray [6] allows you to spot a sample on a disposable paper triangle and to obtain electrospray ionization mass spectra without the complication of pumps or plumbing. FilterSpray can even be used for ambient inorganic analysis [7]. A FilterSpray attachment can be mounted onto the linear rail of the AccuTOF-DART to permit FilterSpray analysis on the sample platform as DART without any hardware modifications. Figure 6. FilterSpray analysis shows Pb and Cr from lead chromate pigment on a 1948 Gold Star Mothers postage stamp. JEOL USA, Inc. 2016 www.jeolusa.com Page 4

Conclusion The AccuTOF-DART provides a versatile platform for ambient ionization mass spectrometry. A wide range of ambient ionization methods can be carried out without removing the DART ion source. This provides the chemist with complementary techniques to analyze a wide variety of chemical compounds and materials. References [1] R. B. Cody, J. A. Laramee, H. D. Durst. Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions. Anal. Chem., 2005, 77, 2297. [2] R. B. Cody, A. J. Dane. Soft Ionization of Saturated Hydrocarbons, Alcohols and Nonpolar Compounds by Negative-Ion Direct Analysis in Real-Time Mass Spectrometry. Journal of The American Society for Mass Spectrometry, 2013, 24, 329. [3] R. B. Cody, A. J. Dane. Dopant-assisted direct analysis in real time mass spectrometrywith argon gas. Rapid Communications in Mass Spectrometry, 2016, 30. [4] A. J. Dane, R. B. Cody. Selective ionization of melamine in powdered milk by using argon direct analysis in real time (DART) mass spectrometry. Analyst, 2010, Advance Article. [5] S. Trimpin. "Magic" Ionization Mass Spectrometry. Journal of the American Society for Mass Spectrometry, 2015, 27, 4. [6] J. Liu, H. Wang, N. E. Manicke, J.-M. Lin, R. G. Cooks, Z. Ouyang. Development, Characterization, and Application of Paper Spray Ionization. Analytical Chemistry, 2010, 82, 2463. [7] R. B. Cody, A. J. Dane. Paper spray ionization for ambient inorganic analysis. Rapid Communications in Mass Spectrometry, 2014, 28, 893. JEOL USA 11 Dearborn Road Peabody MA 01960 978-535-5900 www.jeolusa.com JEOL USA, Inc. 2016 www.jeolusa.com Page 5