Optimalization of the overhead lines insulation system

Similar documents
Experimental and numerical studies of the effect of high temperature to the steel structure

Transactions of the VŠB Technical University of Ostrava, Mechanical Series No. 1, 2014, vol. LX article No. 1979

Transactions of the VŠB Technical University of Ostrava, Mechanical Series No. 1, 2010, vol. LVI article No. 1772

Transactions of the VŠB Technical University of Ostrava, Mechanical Series No. 3, 2009, vol. LV article No. 1725

Monitoring of Precipitable Water Vapor Over the Czech Republic by GPS

USE OF ROBUST CHARACTERISTICS FOR METALLURGICAL PROCESS MODELLING. Tošenovský,F., Tošenovský,J., Smajdorová,T., Growková,V.

Pareto - ABC Analysis of Temperature Field in High Voltage Three-Phase Cable Systems

Numerical Calculation and Analysis on the Surface Electric Field Characteristics of Hot-Line Robot

Analysis of the transients on the multi-circuit overhead transmission line

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK

INFLUENCE OF UNDERCOOLED SURFACE OF CCSP ON CORE PROPAGATION OF PLASTIC DEFORMATION. Richard Fabík a Jiří Kliber a

188 Equating the moments of above two forces about point O, we get, T y = w x x or y = w x T The maximum dip (sag) is represented by the value of y at

Practical Application of the New Digital Snow Load Map

The Influence of Phase Transposing on Double Circuit Overhead Power Line Magnetic Field

Overhead lines. 110 kv wood tower with guy wires

Transactions of the VŠB Technical University of Ostrava, Mechanical Series. article No VARIABLE PITCH PROPULSION DRIVE MODEL

Transactions of the VŠB Technical University of Ostrava Civil Engineering Series, No. 2, Vol. 15, 2015 paper #16. Jozef MELCER 1

Modelling of Surface and Bulk Resistance for Wearable Textile Antenna Design

MOFLEX. Insulated copper flexibars

Transactions of the VŠB Technical University of Ostrava, Mechanical Series. article No. 1918

The elimination of vertical refraction in trigonometric measurements of height differences

Prof. Dr. Magdi El-Saadawi

Simulation Studies of Composite Insulators used in High Voltage Transmission

1. Explain the various methods of methods of grounding. In power system, grounding or earthing means connecting frame of electrical equipment (non-cur

An Application of Graph Theory in Markov Chains Reliability Analysis

Study of coupling between bending and torsional vibration of cracked rotor system supported by radial active magnetic bearings

Building Energy Efficiency: Optimization of Building Envelope Using Grey-Based Taguchi

Some Aspects of Stress Distribution and Effect of Voids Having Different Gases in MV Power Cables

MODELLING OF TRANSPORT ACCESSIBILITY FOR MUNUCIPALITIES OF THE CZECH REPUBLIC

PERFORMANCE-BASED DESIGN APPLIED FOR A BEAM SUBJECTED TO COMBINED STRESS

Available online at ScienceDirect. Andrej Godina*, Bojan Acko

Gábor Göcsei. Improved protection of working personnel during high voltage live-line maintenance

USE OF CFD TOOL ANSYS FLUENT FOR FIRE SAFETY IMPROVEMENT OF AN INDOOR SPORTS ARENA

NUMERICAL ANALYSES OF ELECTROMAGNETIC FIELDS IN HIGH VOLTAGE BUSHING AND IN ELECTROMAGNETIC FLOW METER

Temperature and Field Dependence of Field Grading Tubes for Medium Voltage XLPE Cable Joints

Sborník vědeckých prací Vysoké školy báňské - Technické univerzity Ostrava číslo 1, rok 2008, ročník LIV, řada strojní článek č.

PHYSICAL MODELLING OF FLOW PATTERN IN 5-STRAND ASYMMETRICAL TUNDISH WITH BAFFLES. Karel GRYC, Karel MICHALEK, Zbyněk HUDZIECZEK, Markéta TKADLEČKOVÁ

Lectures on Linear Algebra for IT

NYY-J/-o 34 NYCWY 36 NYCY 37 NAYY 38

Transactions of the VŠB Technical University of Ostrava, Mechanical Series. article No. 1887

Embedded Control System of Apparatus for Measurement of Thermal Conductivity

Collation Studies of Sequence Impedances for Underground Cables with Different Layouts

Electric Filed Simulation and Structure Optimization for 40.5kV GIS Based on Finite Element Method

THE DIMENSIONING OF ELECTRICAL CONDUCTORS FOR USE IN "PANEL BOARDS" ADDRESSED TO HAZARDOUS AREAS - PART THREE

We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors

UNAVAILABILITY CALCULATIONS WITHIN THE LIMITS OF COMPUTER ACCURACY ABSTRACT

Worked Example for the Calculation of Earthing Current and Electric Shock Hazard Potential Difference in a Rod and Grid Earthing System

Analysis of surge arresters failures in the installation of broadcasting transmitter

COMPARISON OF TIME-STEPPING METHODS FOR TRANSIENT MAGNETIC FIELD COMPUTATIONS IN COMSOL MULTIPHYSICS

An Optimised High Current Impulse Source

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Computation of Electric Field for FGM Spacer Using Di-Post Insulator in GIS

SCIENCE & TECHNOLOGY

Lectures on Linear Algebra for IT

Simulation of Partial Discharge in Solid Dielectric Material

PARTICLE TRAJECTORIES IN A THREE PHASE COMMON ENCLOSURE GAS INSULATED BUSDUCT WITH MONTE CARLO TECHNIQUE

Measurement and simulation of the electric field of high voltage suspension insulators

Modeling Electric Field and Potential Distribution of an Model of Insulator in Two Dimensions by the Finite Element Method

[1] (b) State one difference and one similarity between the electric field of a point charge and the gravitational field of a point mass....

F F FAULT CURRENT Prospective. 1. Introduction. 2. Types of fault conditions

The Lightning Study of Overhead Transmission Lines

Modeling of Power System Components During Electromagnetic Transients

Examination of the Fatigue Life under Combined Loading of Specimens

A Novel Optimized Design for Busbar Structures using Finite Element Methods

Transactions of the VŠB Technical University of Ostrava, Mechanical Series No. 1, 2009, vol. LV article No. 1677

Direct Optimized Probabilistic Calculation - DOProC Method

Comparison of Magnetic Field and Iron Loss Models for 2-Dimensional Magnetic Anisotropic Properties

1. Introduction. 2. Use of COMSOL Multiphysics

Krantz Components. Twist outlet DD-N... for ceiling installation. Air distribution systems

Transactions of the VŠB Technical University of Ostrava, Mechanical Series. article No Doubravka STŘEDOVÁ *, Petr TOMEK **

Application of Lightning Location System Data for Designing the External Lightning Protection System

The Enlarged d-q Model of Induction Motor with the Iron Loss and Saturation Effect of Magnetizing and Leakage Inductance

BASIC RESEARCH OF THERMAL TRANSFER SIMULATIONS

Intensity Distribution of Strong Magnetic Fields Created by Opposing Linear Halbach Assemblies of Permanent Magnets

Sborník vědeckých prací Vysoké školy báňské - Technické univerzity Ostrava číslo 1, rok 2014, ročník XIV, řada stavební článek č. 18.

SIGNIFICANCE OF TRANSPOSITION FOR 220KV TOWER

Detection and classification of faults in induction motor by means of motor current signature analysis and stray flux monitoring

PHYSICAL CONTROL OF EXPERIMENT BY USING THE INTERNET SCHOOL EXPERIMENTAL SYSTEM - ISES. Karol KVETAN, Robert RIEDLMAJER, Marek MIZERA

Transactions of the VŠB Technical University of Ostrava, Mechanical Series. article No Adam BUREČEK *, Lumír HRUŽÍK **

Comparison of Temperature Loadings of Bridge Girders J. Římal, D. Šindler

Arrangement of conductors in 220 kv double circuit line to reduce E-fields in view of public exposure

Analysis of Electric DC Drive Using Matlab Simulink and SimPower Systems

PUBLICATION. Thermal Design of an Nb3Sn High Field Accelerator Magnet

Tailoring of new Field Grading Materials for HVDC Systems. Dipl.-Ing. Maximilian Secklehner Rashid Hussain, M.Sc.

256 D. Mayer B. Ulrych: ELECTROMECHANICAL ACTUATORS DYNAMICS

Copyright 2014 IEEE. Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, October, 2014.

NONLINEAR IDENTIFICATION ON BASED RBF NEURAL NETWORK

HIGH VOLTAGE ENGINEERING. Electric discharges in electric power engineering

The influence of structural damping on flutter characteristics of a small sport aircraft

M [scale units/s] of the system

LINEAR SOURCES WITH NON-LINEAR DISTRIBUTION OF SOUND ENERGY. Miroslav Kučera, Richard Nový, Jiří Bašta

MEASUREMENTS AND CALCULATIONS OF NON-IONIZING RADIATION LEVELS IN VICINITY OF 35 KV OVERHEAD POWER LINES

Recent Improvements in K-Factor Models

AP Physics Study Guide Chapter 17 Electric Potential and Energy Name. Circle the vector quantities below and underline the scalar quantities below

TD-102. HAEFELY HIPOTRONICS Technical Document

Comparison protocol EURAMET project

TRANSMISSION LINES. All aluminum alloy conductor (AAAC) Aluminum conductor alloy reinforced (ACAR)

COMPARISON OF MODELS FOR OPTIMAL CONTROL OF SELECTED METALLURGICAL AGGREGATES

Engineering Recommendation EREC S34 Issue 2, November A guide for assessing the rise of earth potential at electrical installations

Lab 1: Numerical Solution of Laplace s Equation

Transcription:

Stanislav MIŠAK, Štefan HAMACEK VŠB Technical University Ostrava Optimalization of the overhead lines insulation system Abstract. The optimalization of medium voltage overhead lines with covered conductors will be solved within this paper. The distribution of electric intensity around the tower of overhead lines will be specified by Finite Elements Method in the concrete. The mathematical modelling will be used as a support for design of new geometrical settlement of covered conductor in the towers. The mathematical program ANSYS will be used as an optimalization program in the concrete. The increasing of safety and reliability of medium voltage system is possible with using results from these mathematical simulations. Streszczenie Artykuł przedstawia rozwiązanie zadania optymalizacji linii napowietrznych średniego napięcia z przewodami izolowanymi. Do określenia rozkładu natężenia pola wokół słupów linii napowietrznych została użyta metoda elementów skończonych. Modelowanie matematyczne wykorzystano jako wsparcie dla zaprojektowania nowych geometrii rozmieszczenia przewodów. Do optymalizacji użyto matematycznego programu ANSYS. Wyniki przeprowadzonych symulacji pozwalają zwiększyć bezpieczeństwo i niezawodność linii SN. (Optymalizacja linii napowietrznych z przewodami izolowanymi). Keywords: ANSYS, electric field, overhead lines, medium voltage Słowa kluczowe: ANSYS, pole elektryczne, linie napowietrzne, srednie napięcie Introduction The PAS-type system originated through a line construction in Finland in 1976. Such lines started to be built also in Sweden and Norway and gradually they arrived to other countries as well including the Czech Republic. The design of such lines do not differ anyhow from the overhead lines with bare conductors. A significant change is the XPE insulation of the PAS system which allows for shortening the distance among phases down to 1/3 the distance of the system with bare conductors. Nowadays the programs such as ANSYS are increasingly used for physical fields simulation. Modelling physical fields brings a lot of precious information to the area of using insulated suspended conductors for overhead lines. The paper discusses the electrostatic field for various geometric configuration of overhead line conductors. The calculation using the finite element method and subsequent graphical display of results provides the possibility to find the most suitable geometric configuration of overhead line conductors or propose some better configuration. The ANSYS program solved both electric intensity and electric potential in the conductors surroundings. The values of electric intensity were calculated for time interval t = (0,001 0,02) s after 1 ms in operating state (U f = 13kV). The paper also presents the calculations of the dependence on insulation thickness and the distance among individual conductors on the pole design. This data can be also used for further optimization of both geometric layout of conductors at the poles and the production of overhead line conductors themselves. [8] Fig. 1. SAX-W 22 kv Used geometric conductor layout at the consoles for the calculation in ANSYS program For the calculation in the ANSYS program the values of the distance among phases were selected as per the following types of design: 1. Anchorage console 3x IZV with overhang to JB and DB pole (distance among phases 600 mm) 2. Corner running console 3x IZV to JB and DB pole (distance among phases 950 mm) see Fig. 2. 3. Vertical anchorage console 3x IZV to JB pole (distance among phases 500 mm) 4. Vertical anchorage console 6x IZV to DB pole (distance among phases 600 mm) 5. Horizontal console 6x IZV to DB pole (distance among phases 600 mm) Explanation of abbreviations: IZV insulated line, JB - concrete pole, DB - double concrete pole, Description of the elements and their parameters necessary for calculation Conductor SAX W (PAS - W) 22 kv An insulated conductor for overhead lines with the XPE insulation of the PAS system. Table. 1. Mechanical properties of insulated conductors [1] Nominal voltage (kv) 22 Nominal cross-section (mm 2 ) 70 Nominal insulation thickness (mm) 2,3 Minimum insulation thickness (mm) 1,98 Informative conductor diameter (mm) 14,7 Fig. 2. Example of conductor layout at console No. 2 Solution in ANSYS program Parameters needed for calculation To do calculations in the ANSYS program, it is necessary to define the electric properties of individual used materials. Such properties are defined by means of permitivity whose values are shown is Table 2. PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 87 NR 2/2011 65

Table. 2. Material permitivity Material Permitivity (-) Aluminium 10 6 XPE 2,4 Air 1 Ground 20 All calculated values of electric intensity (within time interval t= 0,001 0,02 s) for each conductor layout are shown at diagram see Chart 2. This diagram shows that the lowest values were for the console No. 2 where the maximum intensity value was E max = 0,56 kv.mm -1. The highest values of electric intensity were recorded for the console No. 3 where the maximum intensity values were around the value E max = 0,64 kv.mm -1. As it was a 2D calculation, the element PLANE 121 was used which is applied to the formulation of scalar electric potential and is generally used for 2D electrostatic and timely harmonic analyses of electric field and thus it is very appropriate for calculating the locations with a very high local value. [8] The voltage value for the calculation will be U f = 13 kv and the length of recording t=(0,001 0,02) s. Calculations of the real conductor arrangement at the pole console Here the electric fields are calculated at various pole types as they are used in practice. Fig. 3 shows an example of the intensity distribution around conductors fixed at the console No. 2 for voltage value U f = 13 kv. U s (1) U f (V;V) 3 22000 U f 12702 V 13 kv 3 Chart. 2. Comparison of the intensity of conductor layout in the air [8] As it can be seen from the diagram, the material used for insulation has very good insulation properties and that is why the intensity values are around neglectable values. For better orientation the results of maximum intensity values are shown in the diagram seechart 3. Fig. 3. Intensity distribution around the conductors of No.2 [8] In the results Chart. 1 the courses of calculated values can be seen as the changes in electric intensity and electric potential depending on the distance from the conductor centre. The values are assessed within the distance of 59 cm. Chart. 3. Comparison of maximum intensity [8] Calculation of electric intensity depending on conductor distances This part of the paper shows the values of calculated electric intensity depending on the distance of conductors from each other. The first calculation is done for the distance of l= 0,01 mm among conductor insulations where the maximum intensity of electric field is E max = 19,2 kv mm -1 see. Fig. 4. E sum = 19,2 kv mm -1 Chart. 1. Dependence of electric intensity and electric field depending on the distance from the conductor centre. Fig. 4. E max for distance 0,01 mm among conductors 66 PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 87 NR 2/2011

Another calculations were made for distances 50, 100, 150, 200 mm among the centres of individual conductors. For distance l= 50 mm the value of maximum intensity was E max = 1,52 kv mm -1, for distance l= 100 mm it was E max = 1,07 kv mm -1, for distance l= 150 mm it was E max = 0,9 kv mm -1 and for distance l= 200 mm it was E max = 0,82 kv mm -1. 2 m Figures 5 and 6 show an example of electric field distribution in time t= 0,003 s for conductor distances 50 and 200 mm. According to the distribution of electric field colours at the figure the value of electric field intensity was read at the point that is in the centre among conductors marked with the yellow arrow. Especially the comparison of electric intensity depending on conductor distances needed to be made here. At Fig. 5 the intensity was E sum50 = 0,4 kv mm -1 and at the figure Fig. 6 the intensity was E sum200 = 0,08 kv mm -1. The courses of intensity for all calculations are shown at the diagrams see Chart 5 and Chart 6.. For XPE insulation material the value of specific dielectric strength is presented approx. at 30 to 40 kv mm -1. As it is apparent from the graphical display, the values of material dielectric strength are not exceeded even for the conductor distance of zero. E sum = 0,4 kv mm -1 Fig. 5. Distribution E max at time t=0,003s, l= 50 mm E sum = 0,06 kv mm -1 2 m Chart. 5. Dependence of intensity on conductor distance Fig. 6. Distribution E max at time t=0,003s, l= 200 mm In the diagram see. Chart 4 shows the values of calculated courses of electric field intensity for conductor distances 50 mm and 200 mm. The diagram values for both distances were read in the direction indicated by the yellow arrow at Fig. 5 andfig. 6. Chart. 6. Dependence of intensity on conductor distance The review of maximum values of electric intensity are shown at Chart 7.. Chart. 7. Values E max in dependence on conductor distances [8] Chart. 4. Evaluation of the intensity among conductors in the distance 50 and 200 mm Calculation of electric intensity depending on the thickness of conductor insulation Another task was to compare how the electric field changes in dependence on the thickness of conductor PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 87 NR 2/2011 67

insulation In the calculation the insulated suspended conductor 22-PAS 70 mm 2 was used with the insulation thickness of 2 mm. Then the insulation thickness was increased by 0,5 mm to 2,5 mm. The calculation was made for mutually twisted conductors. So the calculation using ANSYS program was made for the triangle conductor layout. The maximum value of electric intensity for insulation thickness 0,73 mm was E max = 46 kv mm -1, for 1,03 mm it was E max = 36,2 kv mm -1, for 1,23 mm it was E max = 28,8 kv mm -1, for 1,98 mm it was E max = 24,6 kv mm -1, for 2,23 mm it was E max = 24,6 kv mm -1 (see. Fig. 8) and for insulation thickness 2,48 mm the value of intensity was E max = 15,5 kv mm -1. Fig. 8 shows the field area of electric intensity A, which is also shown in the diagram, see Chart 8. As it can be seen from the diagram, also in this part of the field the decrease of electric intensity regarding the distance was smaller which also stems from the diagram itself. to insulation can have cause a defect of HV insulated overhead lines. A Chart. 8. Evaluation of electric field intensity Fig.7. Intensity for insulation thickness 2 mm A E max = 24,6 kv mm -1 Chart. 9. Course of electric intensity depending on the thickness of conductor insulation The results show that even a small change in insulation thickness can contribute to higher reliability of insulated overhead conductors. It can be presumed that such a geometric conductor layout could be implemented in practice. Acknowledgment This paper was prepared in the framework of research project MŠM No 6198910007 and SP/201073. Fig. 8. Detailed view of the place with the highest intensity value The dependence of electric intensity on insulation thickness in time interval t=(0,001 0,02)s is shown in the diagram, see Chart 9. The diagram clearly shows that for insulation thickness 1,23 mm the insulation still conforms to the maximum breakdown strength for the XPE insulation. When calculating for insulation thickness 1,03 mm, it can be seen that at this minimum difference the XPE insulation does not conform to required parameters anymore. From that it can be derived that even a small mechanical damage Conclusion Nowadays insulated suspended lines are increasingly used for overhead lines. This paper discussed the electric intensity for various geometric conductor layout at pole consoles. The reason for doing such a calculation was to get a general overview of electric intensity and its influence on the insulation system of insulated suspended lines. The diagram Chart 1 shows the changes in electric intensity and electric potential depending on the distance from the conductor centre. The appearance of electric field and the calculation direction shows the diagram, see Chart 1. Further calculations analyzed, using the finite element method, electric field around conductors at various 68 PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 87 NR 2/2011

distances from each other. The goal was to find out how far the conductors can be arranged from each other so that electric intensity action does not exceed the value of insulation breakdown strength E p = (30 40) kv mm -1. For the lowest distance l = 0,01 mm the maximum intensity of electric field was E max = 19,2 kv mm -1 see. Fig. 4. This value conforms to the required values of breakdown strength for insulation XPE. More details about the solution and conclusion are in the text itself. Then the dependence of electric intensity on the thickness of conductor insulation was resolved. For the calculation the example is presented when the conductors are mutually twisted and the intention was to determine whether such geometric conductor layout conforms to the limits of electric strength of XPE material. The calculated maximum value of electric intensity for insulation thickness 2,23 mm was E max = 24,6 kv mm -1 see. Fig. 7 and for insulation thickness 2,48 mm the value of intensity was E max = 15,5 kv mm -1. For insulation thickness 1 mm the value was E max = 36,2 kv mm -1 which means that for this insulation thickness the value of breakdown strength for insulation XPE was crossed. The results presented in this part show that even a small change in insulation thickness of mere 0,5 mm has a large impact on the electric field intensity around conductors which decreased down to 10 kv mm -1. At point A in Fig. 8 the electric intensity decrease is smaller which is apparent also from the diagram, see Chart 8. The reason is that they were at a larger area with similar electric intensity due to the distance and direction of values calculation. The results obtained though solving electrostatic field for various geometric conductor layout at pole consoles can be further used for lead optimalization and the design of new lead-supporting structures or changing the parameters of insulated suspended conductors in such a way that the conductor electric properties are improved. Then these changes can have a share in saving the material for production the consoles for fixing suspended insulated conductors and in protecting the environment. REFERENCES [1] Katalog NKT cables [cit. 2009-10-20], Dostupný na WWW: http://www.cez.cz/edee/content/file/o-spolecnosti/10-6-1-vodicizolovany-22kv-50-70-120-mm2.doc [2] Mišák, S., Mathematical model of electric arc at high voltage systems, 18th DAAAM International Symposium 25th October 2007 at the University of Zadar, Zadar, Croatia. Ed. Branko Katalinic, Publisher DAAAM International Vienna, Vienna 2007, Zadar:University of Zadar, 2007, Editor: Branko Katalinic, Publisher DAAAM International Vienna, Vienna 2007, s. 150-154, University of Zadar, ISBN 3-901509-60-7 [3] Mechanical Engineering [cit. 2010-1-20], Dostupný na WWW: http://www.me.cmu.edu/academics/courses/nsf_edu_proj/thfl Engr_ANSYS/about_ansys.htm [4] Hamacek, Š., Experimental analysis of breakdown strength of type CYKY cables in dependence on the temperature, Sborník konference ISEM 2009, ČVUT Praha, ISBN 978-80-01-04417-9 [5] Hamacek, Š., Experimentální zjišťování průrazné pevnosti typových kabelů CYKY v závislosti na teplotě se simulací elektrostatického pole, Sborník konference ANSYS 2009, Plzeň, ISBN-978-80-254-5437-4 [6] Hamacek, Š., Experimentální zjišťování průrazné pevnosti - Pevné izolanty, Diplomová práce, VŠB-TU Ostrava, FEI, Kat- 453, 2009 [7] stránky: ACADEMIC COMPUTING and COMMUNICATIONS CENTER [cit. 2010-1-20], Dostupný na WWW: http://uic.edu/depts/accc/software/ansys/html/guide_55/gele/gele13.htm [8] Mišák S., Hamacek Š., Využití programového prostředí ANSYS, pro optimalizaci vodičů venkovního vedení, Sborník konference EPE 2010, Brno Authors: Association Prof. Dipl. Ing. Stanislav Mišák, Ph.D., VŠB Technical University of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Electrical Power Engeneering, 17th listopadu 15, 708 33 Ostrava - Poruba, Czech Republic, E-mail: stanislav.misak@seznam.cz; Dipl. Ing. Štefan Hamacek, VŠB Technical University of Ostrava, Faculty of Electrical Engineering and Computer Science, Department of Electrical Power Engeneering, 17th listopadu 15, 708 33 Ostrava - Poruba, Czech Republic, E-mail: stefan.hamacek@seznam.cz PRZEGLĄD ELEKTROTECHNICZNY (Electrical Review), ISSN 0033-2097, R. 87 NR 2/2011 69