Introduction to Spectroscopy: Analysis of Copper Ore

Similar documents
Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Experiment 7A ANALYSIS OF BRASS

EXPERIMENT #3 A Beer's Law Study

CH 112 Special Assignment #4 Chemistry to Dye for: Part C

Experiment 11 Beer s Law

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex

Experiment#1 Beer s Law: Absorption Spectroscopy of Cobalt(II)

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Experiment 11 Beer s Law

Determining the Concentration of a Solution: Beer s Law

MEASUREMENT: PART II

EXPERIMENT 6 INTRODUCTION TO SPECTROSCOPY

Chemistry 1215 Experiment #11 Spectrophotometric Analysis of an Unknown Brass Sample

Experiment 13I THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

PREPARATION FOR CHEMISTRY LAB: FLUORIDE IN WATER

MORE LIGHTS, COLOR, ABSORPTION!

Chemical Kinetics: Integrated Rate Laws. ** updated Procedure for Spec 200 use **

Spectrophotometry Materials

Density of Aqueous Sodium Chloride Solutions

Density of Aqueous Sodium Chloride Solutions

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Determining the Concentration of a Solution: Beer s Law

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

REVIEW OF LAB TECHNIQUES

Chesapeake Campus Chemistry 111 Laboratory

Accuracy and Precision of Laboratory Glassware: Determining the Density of Water

EXPERIMENT 23. Determination of the Formula of a Complex Ion INTRODUCTION

Kinetics of Crystal Violet Bleaching

Determining the Concentration of a Solution: Beer s Law

The Determination of an Equilibrium Constant

DETERMINATION OF AN EQUILIBRIUM CONSTANT

Lab Investigation 4 - How could you make more of this dye?

Determination of an Equilibrium Constant Minneapolis Community and Technical College Principles of Chemistry II, C1152 v.1.16

REVIEW OF LAB TECHNIQUES

Ascorbic Acid Titration of Vitamin C Tablets

DETERMINATION OF K c FOR AN EQUILIBRIUM SYSTEM

Atomic Theory: Spectroscopy and Flame Tests

Spectrophotometric Determination of an Equilibrium Constant

Determination of an Equilibrium Constant

RATE LAW DETERMINATION OF CRYSTAL VIOLET HYDROXYLATION

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

2014 NJIT RET Program. MODULE TOPIC: Two Methods of Determining the Concentration of Soluble Compounds or Analytes..

Introduction to Chemistry Techniques Prelab (Week 1) 2. Determine the number of significant figures in each of the following numbers.

Chemical Kinetics: Determining Rate Laws for Chemical Reactions

Chemistry 213. A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH LEARNING OBJECTIVES

For simplicity, we ll represent BTB s ionization in a solution by the equilibrium: HBTB = H + + BTB -

Beer s Law 29 January 2019

Ascorbic Acid Titration of Vitamin C Tablets

PRELIMINARY ACTIVITY FOR

Experiment #7. Determination of an Equilibrium Constant

Acid-Base Titration Curves Using a ph Meter

Ascorbic Acid Titration of Vitamin C Tablets

Solubility Product Constants

Experimental Procedure. Lab 406

Determination of an Equilibrium Constant

Determination of Orthophosphate Ion

Experiment 8 Introduction to Volumetric Techniques I. Objectives

#09 Investigating the Relationship between the Mass of a Liquid and its Volume Ken Lyle, St. John s School, Houston, TX

INTRODUCTION TO ACIDS, BASES AND TITRATION

Atomic Theory: Spectroscopy and Flame Tests

Investigating Food Dyes in Sports Beverages. Sample

Determination of Orthophosphate Ion

Experiment 2: THE DENSITY OF A SOLID UNKNOWN AND CALIBRATION WITH DATASTUDIO SOFTWARE

Determination of Density 1

Rate Law Determination of the Crystal Violet Reaction. Evaluation copy

Colorimetric analysis of aspirin content in a commercial tablet

Atomic Theory: Spectroscopy and Flame Tests

Atomic Theory: Spectroscopy and Flame Tests

CHEM 334 Quantitative Analysis Laboratory

Determination of the Rate of a Reaction, Its Order, and Its Activation Energy

Part II. Cu(OH)2(s) CuO(s)

Spectrophotometric Determination of an Equilibrium Constant 1

Aspirin Lab By Maya Parks Partner: Ben Seufert 6/5/15, 6/8/15

Chemistry Calibration of a Pipet and Acid Titration

EXPERIMENT 9 SALTWATER CONDUCTANCE: The Effect of Concentration

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

Lab 5: Calculating an equilibrium constant

Experimental Procedure Lab 402

Exp 03 - Reaction Rate

CHEMICAL KINETICS E + 2B 2C + D (1)

Ascorbic Acid Titration of Vitamin C Tablets

Experiment 8: DETERMINATION OF AN EQUILIBRIUM CONSTANT

Acid-Base Titration Curves Using a ph Meter

Experiment 10 Dye Concentration Using a UV-Vis Spectrophotometer

A Study of Beer s Law Prelab

Determination of the Equilibrium Constant for the Iron (III) thiocynate Reaction

Experiment 12: SPECTROSCOPY: EMISSION & ABSORPTION

Spectrophotometric Determination of the Copper (II) Sulfate Pentahydrate Content in a Mixture

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Beer s Law: Determining the Concentration of a Solution

Pre-lab: Read section 9.9 (pages ) on acid-base titrations in the textbook. Complete the attached pre-lab by Tuesday, June 2.

Supernatant: The liquid layer lying above the solid layer after a precipitation reaction occurs.

Shown below is a sample titration curve for a diprotic acid. Note the two equivalence points.

Transcription:

Introduction to Spectroscopy: Analysis of Copper Ore Thousands of years ago, copper was abundant enough in quantity that it could be found on the Earth s surface. Prospecting for copper then was relatively simple. Recently, increased demand for copper resulted in numerous mines, and the search for copper ore is now very competitive. When a copper deposit is discovered, drilling is undertaken to determine the size and grade (concentration) of copper at the potential mining site. Recently, two potential copper mines (labeled Sites A and B) were discovered in southeastern Arizona, just three miles east of Superior. The Resolution Copper Company conducted an exploration project in 2001 that indicates large deposits 7,000 feet below the surface. While the company is still in the early stages of developing the project, they want to determine which site (A or B) will be more profitable to mine. In order to determine this, the company has asked you to analyze samples from both sites for copper concentration. Based on your findings, the Resolution Copper Company will determine at which site they want to mine. Sites that are profitable to mine typically contain 0.4-1.0 % copper. In this experiment, your group will analyze solutions made from copper ore extracted from both sites found by the mining company. In order to leach the copper from the ore and obtain a solution that can be analyzed, the solid ore sample was first dissolved in sulfuric acid and then filtered to remove sediments. Your group will analyze the resulting solutions from sites A and B to determine the concentration of copper at each site and determine if they are economically feasible to mine. You will make solutions of known copper concentration as a baseline against which to compare your unknown samples from sites A and B. Your group will make diluted solutions of copper(ii) sulfate pentahydrate (CuSO 4 5H 2 O) as standard solutions of known concentration. The relationship between concentration and absorption of the diluted solutions will be analyzed and the unknown samples concentrations from sites A and B can be compared to the known solutions concentrations. Spectrophotometric analysis is one method used to determine the concentration of a colored substance in solution. Concentration is determined by calculating the amount of light that passes through a sample and hits a detector. The more light that gets through, the less concentrated the solution is (fewer molecules of the colored substance that absorb light). You have probably noticed this effect in everyday life if you have ever gotten a soda from a dispenser at a fast food restaurant and noticed that it was light in color. As soon as you noticed the light shade of the soda, you realized that it was low in syrup (or even missing syrup altogether). The light color of the drink immediately alerted you to the low concentration of syrup in the soda. A solution containing a colored substance absorbs a specific color (or colors) of visible light and transmits the remaining colors. The amount of light a colored solution absorbs depends on the concentration of the colored substance (mg/ml of solution). Another factor affecting the amount of light absorbed is the color of light (wavelength in nm) selected. If a red solution is analyzed, you need to determine which color of light is best absorbed by the solution. If you select a wavelength in

the red portion of the visible spectrum, what will happen to the light waves when they hit the red sample? (Hint: Is a red shirt absorbing red light or transmitting it?) As discovered in the last lab, a spectrophotometer is an instrument that measures the intensity of a light beam of a given wavelength (color) that passes through a sample. Our machines use wavelengths between 325 and 1100 nm. Light of a given wavelength passes through the sample, hits the detector, and the instrument can calculate the absorbance (A) of the solution. Below is a schematic diagram of a typical spectrophotometer. If the appropriate wavelength is not selected, the sample will not absorb enough light to make an accurate measurement. To select the best wavelength for measurements, we must find the wavelength of maximum absorption. To do this, we plot wavelength (x-axis) versus absorbance (yaxis) and simply find the wavelength that gives the maximum absorbance. The example below shows a peak absorbance occurring at about 610 nm. Concentration may be expressed in several ways. In this exercise, it is expressed as the milligrams of copper per milliliter of solution (mg/ml). To determine the concentration of an unknown, a series of standards must first be prepared. Standards are made by diluting (adding water to) a stock solution to prepare solutions of known concentrations. The absorbance values and concentrations of these solutions are then graphed, and then the unknown concentration of a solution can be determined from the graph.

The relationship between concentration and absorbance can be summarized by using Beer s Law. Mathematically, Beer s Law states that these two quantities are directly (linearly) proportional. A plot of concentration (on the x-axis) versus absorbance (on the y-axis) will produce a linear relationship with a positive slope. A regression line representing the best straight-line fit of your data will produce an equation of the form y = mx + b. To determine the concentration of an unknown solution (for example, the amount of copper in an ore), the absorbance of the unknown solution can be measured and its concentration determined using the linear relationship from the graph. The plot below shows an example of this relationship and the method for approximating the concentration of an unknown. First, a regression line is plotted to give an equation of the line that best fits the data points. In this case, the equation is y = 0.0459 x 0.0021. In this equation, y represents the absorbance value, 0.0459 is the slope, x is the concentration, and 0.0021 is the y-intercept. If an unknown is measured to have an absorbance value of 1.45, we can solve for concentration (x). Solving this equation for x with an absorbance (y value) of 1.45 gives a concentration value of 31.6 mg/ml. You can check your calculation by estimating the concentration graphically. The concentration of the unknown can be estimated by finding the absorbance of the unknown solution, and a horizontal line (the red dotted line) can be drawn from the axis to the regression line of the data. At the intersection of the horizontal line and the regression line, a vertical line (red dotted line) is dropped down to the concentration axis. You can see from this estimation that the unknown has a concentration of approximately 32 mg/ml. This verifies that our calculation above is correct.

Using a Buret and Volumetric Flask: 2.06 ml of solution 2.47 ml of solution 50.00 ml delivered delivered Volumetric Flask Reading a buret: Burets are designed to measure the amount of liquid that has been delivered. Therefore the reading (also called volume ) begins at 0.00 ml and increases as you open the stopcock (parallel to the buret; the stopcock is closed when it is parallel to the ground). The graphics above show how a buret is read. Notice that this is the reverse of other glassware. You read the buret from top to bottom. For example, the buret graphic on the left shows that the reading is 2.06 ml. The buret graphic on the right shows that the reading is now 2.47 ml. To determine the volume of liquid delivered, the initial volume is subtracted from the final volume (2.47 2.06; 0.41 ml were delivered). Burets are always read to two decimal places, the second decimal place is estimated. The long white lines indicate whole milliliters and the short white lines indicate tenths of a milliliter (0.1 ml). You can determine the whole and tenth milliliters and then estimate how far the meniscus is between tenths to estimate volume to the hundredths place. Using a Volumetric Flask: Volumetric Flasks are calibrated to hold an exact volume of liquid when the bottom of the meniscus is exactly on the line. In this lab, you will use 50 ml volumetric flasks that measure volume to 50.00 ml. If you add water above the line marked on the neck of the flask, you will have to remake your solution. You cannot simply remove solution to get the volume down to the line. Fill water drop-wise using a disposable pipet to ensure that you do not pass the 50.00 ml mark.

Procedure: Part I: Preparing the Standard Solutions **Lab Notebook** Note: Anytime you make a table, it should have a title describing the data within the table Your table for Part I should have the following column headings: Solution Starting buret reading (ml) Ending buret reading (ml) Total delivered (ml) Concentration (mg/ml) (Note: Calculations should be completed in lab notebook) Your table should have a row for each solution to be made. For example: 0mL solution, 1mL solution, 2mL solution, etc. should be used in the Solution column. Note that for the 0mL solution, there will be no buret measurements since it contains no CuSO 4. Place an X in the boxes for the buret measurements for 0mL. Turn on the Genesys Spec-20 before you begin this part so it will have plenty of time (about 15 minutes) to warm up. You will work in groups to prepare solutions for this experiment. Your group will be provided with a stock copper solution of copper (II) sulfate, CuSO 4, in a buret. Record its concentration (in mg/ml) on your report sheet. It is important that all students learn how to use the buret and spec-20. Each student should prepare at least one solution (Part I) and take at least 1 absorbance reading (Parts II and III). Your group will make 5 standard solutions (using approximately 1 ml, 2 ml, 4 ml, 6 ml, and 8 ml of stock solution). 1) Use the buret of stock copper solution to deliver volumes as close to whole numbers as you can measure. Add each volume of solution to a clean 50.00 ml volumetric flask. Record the exact volume of stock solution added. Add deionized (DI) water from your wash bottle to the solution. When the meniscus gets close to the line, you may use the plastic pipet to add water drop-wise. Be sure the bottom of the meniscus does not go above the line. If it does, you will have to remake that solution! Stopper the flask and invert it several times to thoroughly mix the solution. 2) Repeat this process to make the next 4 solutions. Label your flasks with pencil or tape. Deliver approximately 1 ml, 2 ml, 4 ml, 6 ml, and 8 ml of stock solution, and fill each volumetric flask to the line with deionized water. Remember to record the exact volume of the buret before and after delivering the stock solution. 3) Stopper all your labeled flasks, invert them several times to thoroughly mix the solutions, and set them aside for part III.

Using the Spec-20: Part II: Finding the Maximum Absorbance for Copper Solutions **Lab Notebook** Your table for Part II should have following column headings: Wavelength (nm) Absorbance Your table should have a row for each wavelength to be tested Ø Hint: You will be taking measurements initially from 400-900nm in increments of 100nm. After finding the wavelength which has highest absorbance, you will then take readings 10, 20, and 30nm above and below the wavelength with the highest absorbance. From this information, how many rows should you have? Ø Below your table, record the wavelength which gave you the maximum absorbance, this is called λ max (lambda max). Your instructor must sign off on this wavelength before you move to the next part. Ø You will then graph all your data in your notebook (example plot shown in procedure). Your group will generate a table and graph of wavelength versus absorbance to determine the wavelength at which the maximum absorbance occurs for your 8.00 ml solution. As you take your readings, you will have to recalibrate the Spec-20 ( set the blank ) using DI water for each new wavelength. 1) Press the A / T / C button until an A appears in the upper right corner of the display. 2) Use a disposable pipet to fill one cuvette 2/3 full with DI water and a second cuvette 2/3 full with your last (8.00 ml stock) solution. Check each cuvette for air bubbles. If you see air bubbles clinging to the walls of a cuvette, tap the cuvette gently to get the bubbles to rise to the top of the solution and escape. Use a Kim-wipe to wipe off the outside of the cuvettes. 3) Follow steps a e below to determine the absorbance for each wavelength. a) Place the water cuvette in the holder with the clear sides aligned with the arrow. (This arrow shows the direction in which light is aimed.) b) Select the first wavelength to test (400 nm) using the up/down nm buttons. (They scroll quickly if you hold the button down.) c) Press the 0 Abs/100 % T button to calibrate the instrument for that wavelength. d) Remove the cuvette with water and replace it with the cuvette of solution. DO NOT press any buttons!!! e) Read the absorbance on the display for your solution. If it reads a small negative number, record a value of 0 for that reading.

5) Repeat steps a e for water and the first solution cuvettes at a wavelength of 500 nm. Record the absorbance values in the table under Part II on the Report sheet. Also repeat steps a-e to obtain absorbance readings at wavelengths of 600, 700, 800, and 900 nm. 6) Examine your absorbance readings to find the maximum value for the 100-nm intervals. Take readings 10, 20, and 30nm above and below the wavelength with the maximum absorbance. For example, if you found 600 nm to be the highest value, repeat steps a e for wavelengths of 610, 620, 630, 590, 580, and 570 nm. 6) Plot and connect the 12 data points on the graph provided in the handout. The wavelength that gives the maximum absorbance, λ max (lambda max), is the wavelength you want to use for Part III of this experiment (see example graph below). 7) Have your instructor sign off on your chosen wavelength before you continue to Part III. Ø Using the data you collect from Part II, plot ALL of your data in your notebook. Connect the points with a smooth curve. Example: Plot Part II - Finding the Maximum Absorbance for Copper Solutions 2.25 2.0 1.75 Absorbance 1.5 1.25 1.0 0.75 0.50 0.25 0 400 450 500 550 600 650 700 750 800 850 900 Wavelength (nm)

Part III: Measuring Absorbance Values for the Known and Unknown Solutions **Lab Notebook** Your table should have the following column headings: Solution Concentration (mg/ml) (same values from your first table for your known solutions) Absorbance (for standards and unknowns) You should have a row for each solution to be tested. For example: 1mL solution, 2ml solution, Site A, etc. should be used in the Solution column. For the 0mL sample, you should record a value of 0 for the absorbance. Your group will use the wavelength found in Part II to determine the absorbance for each solution made in Part I. You will then analyze the copper content in unknown samples taken from the two drill sites (A and B). 1) Use a cuvette filled 2/3 full with deionized water to calibrate the Spec-20. Select the appropriate wavelength found in part II. Wipe the cuvette off with a clean Kim-Wipe, and place the water cuvette in the sample holder. Close the lid, and press the 0 Abs/100% T button to set the absorbance of the water sample to zero. Do NOT press this button again during Part III. 2) Empty the cuvette, and rinse it twice with small amounts of the first solution to be used. Fill the cuvette 2/3 full with that solution. Wipe the cuvette off with a Kim-Wipe before placing it in the sample holder. After closing the lid, read and record the absorbance of that solution. Do not change the wavelength or press any other buttons on the top of the Spec-20 while you obtain absorbance readings for the standard solutions! 3) Repeat step 2 for all of the standard solutions you made in Part I. 4) Save the solutions until all data collection and graphing is complete. 5) The unknowns contain the same colored metal (copper) solutions as the standards you prepared, but at different concentrations. You will analyze your two undiluted unknowns in the same manner as the standards. 6) Each group should obtain solution from Site A and solution from Site B. The unknowns are in dropper bottles. Add enough solution from the Site A bottle to fill the cuvette 2/3 full. Obtain one unknown at a time to avoid mixing up the samples. Do NOT dilute the unknowns! 7) Without pressing any buttons on the spectrophotometer, place your cuvette with the unknown from Site A in the spectrophotometer and record its absorbance reading. Repeat with your unknown from Site B. Waste Disposal: After you have recorded and graphed all of your concentration and absorbance data from your solutions, discard them in the waste container in the fume hood. GCC CHM 151LL: Introduction to Spectroscopy: Analysis of Copper Ore GCC, 2016 page 8 of 13

Calculations: Concentration of standard solutions: Determine the concentration of dye in each of your standard solutions by using the dilution formula: M 1 V 1 = M 2 V 2 where: M 1 is the initial concentration of the stock solution (mg/ml) V 1 is the total volume that you delivered from the buret for each solution (ml). Use the exact volume delivered, not just 8.00 ml. M 2 is the final concentration of each standard solution you prepared (mg/ml) This is what you are trying to calculate for each solution. V 2 is the total volume of each solution (ml). This will be the same for all of your solutions. What total volume of solution was used for each standard? Graphs: You will use Excel to enter and graph the data you obtain in this lab. The following instructions are for Excel 2010. Enter your data in the worksheet. Enter exact concentrations in the first column and absorbance values in the second. Be sure to include the origin (0, 0) as a data point (from the calibration of water) for a total of 6 data points. Highlight the two columns of data Select: Insert Chart. Select the scatter plot with data points only. Select the graph. From the menu, select: Chart Layout. From here, you can add a title to your graph and label your axes (Concentration on the x-axis (units of mg/ml) and absorbance on the y-axis (unitless)). Add a regression line to your data points to find the best fit of a linear equation to your data. Right-click one of the data points in your graph. Select Add Trendline. For the type of trendline, choose Linear and check the boxes for Display equation on chart and Display R-squared value on chart. The equation option will provide the equation for the line (y = mx + b) that best fits your data points. This line will be used to calculate the concentration for your unknown solutions. The R-squared value will indicate how close your data points are to a straight line. A value close to 1.00 indicates your data is very close to linear. You may want to clean up the formatting of the graph before printing. You can right-click the background to clear it. You can also select and delete the label to the right of the graph. Print your graph, have your instructor initial it, and turn in a copy with your lab report. GCC CHM 151LL: Introduction to Spectroscopy: Analysis of Copper Ore GCC, 2016 page 9 of 13

Ø Use the linear equation (y = mx + b) to determine the concentration of copper in the two unknown solutions. Calculations using linear regression equation: The general equation for a line is represented as y = mx + b, where y is the variable on the y-axis (the dependent variable), m is the slope of the line, x is the variable on the x-axis (the independent variable), and b is the y-intercept. In your lab notebook, include the equation of the linear regression line Also include the R 2 values for the line (R 2 value of 1 means it is a perfect line). Use the equation from the regression line to find the concentration of both unknown solutions (Site A and Site B). Make sure to show your calculation in your lab notebook. (Hints: Which variable(s) in the linear equation do you know? Which variable are you solving for?) Your Lab Report Should include the following: ü Header completed in your lab notebook. ü A purpose statement (in notebook) ü Each section of the experiment clearly labeled (eg: Part I. Preparing Standard Solutions, etc.) Observations clearly written under each section (in notebook) Data tables with a title, proper heading and units (in notebook) Calculations clearly labeled showing all work. Results/Summary tables with a title, proper heading and units (in notebook) Graphs included in the notebook and attached ü Conclusion (in notebook) ü Discussion Questions (answers written on pages 12-13) GCC CHM 151LL: Introduction to Spectroscopy: Analysis of Copper Ore GCC, 2016 page 10 of 13

Pre-Lab Questions Write your answers on this page and turn it in to your instructor before starting this experiment. 1. What formula is used for calculating a dilution? Name: Section: 2. What piece of glassware is the stock solution delivered from for dilution of the sample? 3. What is the chemical formula for the substance dissolved in the stock solution? 4. How many data tables will you be creating in your notebook for this lab? Please list the tables and the variables you be collecting data for for each table: 5. What is the reading shown for the glassware to the right? GCC CHM 151LL: Introduction to Spectroscopy: Analysis of Copper Ore GCC, 2016 page 11 of 13

Name: Section: Discussion Questions Write your answers on these pages and attach them to your report. 1) (2 pts) What is the name of the symbol λ max? What is the definition of this term? Which graph allowed you to determine λ max? 2) Just like the Cu 2+ ion used in today s lab, some other metal ions have a distinctive color when in an aqueous solution. Some examples of ions that give colors in aqueous solution are: Cr 3+, Ni 2+, and Co 2+. However, other metallic ions such as Mg 2+, Al 3+, and Ti 4+ are relatively colorless. a. (6 pts) Write the short-hand electron configurations for the following ions: Ni 2+ Co 2+ Cr 3+ Mg 2+ Al 3+ Ti 4+ b. (3 pts) Based on the electron configurations, what is the main difference between these the metal ions that are colored and the metal ions that are colorless? GCC CHM 151LL: Introduction to Spectroscopy: Analysis of Copper Ore GCC, 2016 page 12 of 13

3) (4 pts) Assuming that the same amount of ore was used to make both unknown solutions, how much more profitable would the copper-rich mine be? Would it be worth paying 30% more for the better ore? Explain and support your conclusion with calculations. 4) (5 pts) You measure a sample of the filtered waste in the Spec-20 at a wavelength of 810 nm and get an absorbance reading of 0.991. Based on the graph of your standard solutions, calculate the copper concentration of the waste jar. 5) Dilution calculation practice: a) (5 pts) How many milliliters of a stock solution of 60.0 mg/ml NaCl would you have to use to prepare 0.500 L of a 12.0 mg/ml solution? b) (5 pts) If you dilute 20.0 ml of a 60.0mg/mL stock solution in to a final volume of 1.00 L, what will be the concentration of the diluted solution? GCC CHM 151LL: Introduction to Spectroscopy: Analysis of Copper Ore GCC, 2016 page 13 of 13