HPLC solvents and mobile phase additives

Similar documents
M M e M M H M M H. Ion Sources

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Electrospray Ion Trap Mass Spectrometry. Introduction

Webinar: How to be More Successful with your ACQUITY QDa Detector Eric van Beelen

The Theory of HPLC. Ion Pair Chromatography

Selecting Detectors for Compounds with No Optical Absorbance

Potential sources of contamination on Mass Spectrometers and suggested cleaning procedures

LC and LC/MS Column Selection Flow Chart

Mass Spectrometry (MS)

Presentation Basic Introduction to Instrumentation Matrix Effects Challenges

Hints for Strong Ion Exchange Resins

Selecting an LC/MS Interface Becky Wittrig, Ph.D.

1) In what pressure range are mass spectrometers normally operated?

Mass Spectrometry. Electron Ionization and Chemical Ionization

LC MS analysis of metabolites. Basis of Chromatography

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Supported Liquid Extraction (SLE) Guide and FAQ s. User Guide

Analysis - HPLC A.136. Primesep 5 µm columns B.136

Hypericin Analysis by LC/MS

Shodex TM ODP2 HP series columns

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

FAQ's. 1 - Which column would be the most appropriate for my application?

LC-MS Based Metabolomics

Quantitative analysis of small molecules in biological samples. Jeevan Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB.

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Supporting Information. Labeled Ligand Displacement: Extending NMR-based Screening of Protein Targets

API Optimization, Source Design, and Other Considerations of LC/MS

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

Mass Spectrometry in MCAL

Molecular Mass Spectrometry

Impurities Sources, Detection and Measurement HPLC-MS Analyses. Dr Courtney Milner Chemical Analysis

POST-COLUMN ADDITION AS A TOOL TO ENHANCE PERFORMANCE IN MICROFLOW LC-MS

C18 Column. Care & Use Sheet

Liquid Chromatography - Mass Spectrometry

penta-hilic UHPLC COLUMNS

QTOF Training Manual

"Theory and Practice of High Speed Chromatography for Bioanalysis" Stuart Coleman March 20, 2007

HICHROM. Chromatography Columns and Supplies. LC COLUMNS SIELC Primesep. Catalogue 9. Hichrom Limited

Mass Spectrometry. Fundamental LC-MS. Electrospray Ionisation Instrumentation

DETERMINATION OF NINE VOLATILE NITROSAMINES AND HYDROXY-NITROSAMINES IN CIGARETTE FILLER AND MAINSTREAM TOBACCO SMOKE

Analysis of Polar Metabolites using Mass Spectrometry

for Acclaim Mixed-Mode HILIC-1 Column

Method Development with ZirChrom's Ion Exchange Phases

SUPPLEMENTARY INFORMATION

High Performance Liquid Chromatography

High Performance Liquid Chromatography

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Acetic Anhydride SpS Code H027 Standard Pack 500ml 1LT 2½LT

isobaric Barbiturates in Serum using LDTD- MS/MS combined with differential mobility

Figure 1. The supported liquid extraction process using the ISOLUTE SLE plate (single well shown)

Supporting Material. 2-Oxo-tetrahydro-1,8-naphthyridine-Based Protein Farnesyltransferase Inhibitors as Antimalarials

Let's compare the ph of the weak nitrous acid with the ph of a strong acid like nitric acid:

Degradation of Rapamycin and its Ring-Opened Isomer: Role of Base Catalysis Yuri V. Il ichev*, Lori Alquier, and Cynthia A.

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Open Column Chromatography, GC, TLC, and HPLC

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

[ CARE AND USE MANUAL ]

Fall 2012 Due In Class Friday, Oct. 19. Complete the following on separate paper. Show your work and clearly identify your answers.

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

CHAPTER-2 Formation of Adenine from CH 3 COONH 4 /NH 4 HCO 3 the Probable Prebiotic Route for Adenine

Sequential dynamic structuralisation by in situ production of

UPLC Intact MASS Analysis Application Kit

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns

HILIC Method Development in a Few Simple Steps

Mass spectrometry.

Spectroscopy in Inorganic Chemistry. Electronic Absorption Spectroscopy

The AccuTOF -DART 4G: The Ambient Ionization Toolbox

1) Which of the following represents the breaking of a noncovalent interaction? Topic: The Nature of Noncovalent Interactions

16 Malachite green 17 Leucomalachite green

Introduction. Chapter 1. Learning Objectives

Reversed Phase Chromatography: Mobile phase Considerations

Barry E. Boyes, Ph.D. Consumables and Accessories Business Unit May 10, 2000

Solid Phase Extraction Method Development Tips and Tricks

FIVE MEMBERED AROMATIC HETEROCYCLES

Find the ph and the degree of ionization for an 0.10 M solution of formic acid:

An Introduction to Mass Spectrometry in the Health Sciences. Tony Mallet

Pelagia Research Library

[ Care and Use Manual ]

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

LC-MS. Mobile Phase Additives Tips & Tricks

SUPPLEMENTARY INFORMATION

ACQUITY UPLC HSS Columns

Evaporative Light Scattering Detector (ELSD)

Amicon Ultra-15 10K Centrifugal Filter Devices

penta-hilic UHPLC COLUMNS

Subject : Chemistry Class : XII Chapter-2.Solutions Work Sheet ( WS 2. 1) Topic- 2.1 Henry s & Raoult s Laws

Mass Spectrometry. Fundamental LC-MS. Solvents, Buffers and Additives

Mass Spectrometry. General Principles

10.1 Acids and Bases in Aqueous Solution

Mixed-Mode, Weak Anion-Exchange, Solid-Phase Extraction Method for the Extraction of Niflumic Acid from Human Plasma

Dilution(*) Chromatography

Reversed Phase Solvents

BIOINF 4399B Computational Proteomics and Metabolomics

Tips and tricks to increase HPLC column lifetime. Dr. Frank Michel

User school lecture. Atmospheric pressure ionization techniques. for high resolution mass spectrometry of complex samples

Why Use the LCQ Advantage MS

Chemistry of Life: Water and Solutions

Chapter 5. Irbesartan. Page no. 64 to 80

Transcription:

HPLC solvents and mobile phase additives The following is intended to be a guide for the choice of solvent and mobile phase additives. Of course the choice of solvents for LC will be dictated primarily by the required separation but there are some guidelines that need to be followed. These are selected examples which have been divided up into three categories; commonly used, unsuitable and other less common ones. In all cases degassed solvents are necessary for LC-MS operation. This is achieved by sonication, helium sparging or vacuum membrane degassing. Solvents Water Acetonitrie Methanol Commonly used solvents These common reverse phase LC solvents are ideal for LC-MS. When using high percentages of water, the source and probe temperature usually need to be raised to aid desolvation in the source. kersti.karu@ucl.ac.uk

Commonly used solvents Additives Acetic acid Formic acid If the ph of the mobile phase needs to be reduced to enhance LC separations then acetic and formic acid are the most suitable. Formic acid is stronger than acetic acid and therefore less needs to be added to reach a required ph. Addition of acids can suppress ionisation in negative mode ion analysis, weakly acidic compounds may not form [M-H] - in acidic conditions. Ammonium hydroxide (ammonia solution) If the ph of the mobile phase needs to be increased to enhance LC separations then ammonium hydroxide (ammonia solution) is suitable. If analyzing weakly acidic compounds in negative ion mode there will be no suppression of ionization. In fact ionization can be enhanced as the mobile phase is not acidic. Ammonium acetate Ammonium acetate is a volatile salt which is often used to buffer mobile phases. It is better to use as little ammonium acetate as possible up to a maximum of 0.1 M. It is often used to replace phosphate buffers, which should be never used with LC-MS interfaces. 1

Unsuitable solvents / additives Non-volatile salts These must not be used as these can crystalise in the source and prevent the mass spectrometer from functioning (blocking skimmers, etc.). The most common non-volatile salts used are phosphates, these should be substituted with a volatile salt such as ammonium acetate/formate. Surface active agents/detergents These can be suppress the ionisation of other compounds. Detergents, by their very nature are concentrated at the surface of a liquid. This causes problems with electrospray as the ionisation relies on the evaporation of ions from the surface of a droplets. The detergent therefore suppresses the evaporation of other ions. Surfactants are only used when they are being analysed themselves, not as additives to LC mobile phases. Inorganic acids Inorganic acids (e.g. sulphuric acid or phosphoric acid) should be not used.

Others Solvents Normal phase solvent Normal phase solvents such as dichloromethane, hexane and toluene have been used but not regularly than reverse phase solvents. These can only be used with APCI and not electrospray which needs a polar mobile phase for ionisation. Propan-2-ol (IPA), 2-methoxyethanol, ethanol etc. These have all been used with LC-MS but their use is limited to specific applications.

Others Additives Trifluoroacetic acid (TFA) This is frequently used for peptide and protein analysis. Levels below even 0.1% can cause suppression of sensitivity in positive ion mode. TFA may completely suppress ionisation in negative ion mode. Triethylamine (TEA) This may suppress the ionisation of less basic compounds in positive ion mode (as TFA is readily ionised to give a [M+H] + ion at m/z 102). In negative mode analysis, TEA enhances ionisation of other compounds as TEA is basic. This is a particularly useful additives for the analyses of nucleic acids. Tetrahydrofuran (THF) This can causes reduced performance which can be counteracted by post-column addition of ammonium acetate. It has no effect in APCI. Caution Do not use a concentration of THF greater than 5% with PEEK tubing. THF causes swelling in the PEEK tubing and consequently presents a risk.

Summary of Additives Do not use: Non volatile salts (phospahtes, etc.) Surfactants, inorganic acids (sulphuric, phosphoric etc.), ammonium acetate (>0.1 M), normal phase solvents in electrospray. Avoid (+ve ion): trifluoroacetic acid (TFA) (0.1%). Avoid (-ve ion): organic acids, e.g. acetic acid, formic acid, trifluoroacetic acid (TFA). Use (+ve ion): acetic and formic acid, ammonium acetate (<0.1 M). Use (-ve ion): trimethylamine (TEA), ammonium hydroxide (ammonia solution), ammonium acetate (<0.1 M)