Concept of Elemental Impurities (EI) assessment in finished dosage forms by total extraction testing

Similar documents
á233ñ ELEMENTAL IMPURITIES PROCEDURES

Elemental Scientific. Spike Recovery. Elemental Scientific

Elemental Scientific. Spike Recovery. Elemental Scientific

RISK ASSESSMENT, IMPLEMENTATION AND VALIDATION OF ELEMENTAL IMPURITIES FOR ICH Q3D, USP <232><233> AND EP 5.20

Elemental Scientific. Stability. Elemental Scientific

Key Analytical Issues: Sample Preparation, Interferences and Variability. Tim Shelbourn, Eli Lilly and Company

ICH Q3D: Practical implementation and the role of excipient data in a risk based approach. Dr Andrew Teasdale

PROCEDURES. Pharmacopeial Forum 2 Vol. 36(1) [Jan. Feb. 2009]

Pharmacopeial Forum Vol. 36(1) [Jan. Feb. 2010] 1

PQRI Technical Analytical Challenges Round 2 Interlaboratory Study: Progress and Early Findings

Validating performance of an Agilent 7800 ICP MS for USP <232>/<233> & ICH Q3D/Q2(R1): Elemental Impurity Analysis in Pharmaceuticals

OPTIMIZING METALS SAMPLE PREP

Hach Method Spectrophotometric Measurement of Free Chlorine (Cl 2 ) in Finished Drinking Water

Using cold vapor generation atomic absorption to determine mercury impurities in pharmaceutical products

Revision: 11 (MBAS) ALLOWAY METHOD OUTLINE. Standard Laboratory Method:

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Data Sharing Initiatives Dr Andy Teasdale

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

Cyanide, Total or Weak Acid Dissociable, by Manual Distillation - PBM

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Update on ASTM and Standard Methods method development activities

Quality Control Procedures for Graphite Furnace AAS using Avanta Software

Test Method: CPSC-CH-E

Dissolution Test 2 was validated using an Inertsil ODS-3V brand of L1 column. The typical retention time for donepezil is about 5.5 min.

Perfluorinated Alkyl Acids (PFAA) in Water by LC/MS/MS - PBM

Introduction to E&Ls 1

Copyright ENCO Laboratories, Inc. II. Quality Control. A. Introduction

Gyrolab Protein A Kit Quantification of residual Protein A ligands in the presence of excess amounts of IgG

why open access publication of stability date is essential Mark Santillo Regional QA Officer SW England

Fundamentals of the ICP-MS Technique and How to Resolve Issues for Pharmaceutical Materials (In 20 Minutes) Tim Shelbourn, Eli Lilly and Company

ASEAN GUIDELINES FOR VALIDATION OF ANALYTICAL PROCEDURES

Nitric Oxide Assay Kit

Instructions for use. Chromogranin A ELISA TM E-9000

Determination of Total Bromine and Iodine Emission Spectrometric Method (ICP-OES) EuSalt/AS

The test can be performed on the following devices. In addition, the required cuvette and the absorption range of the photometer are indicated.

ICP-OES Application Note Number 35

FerroZine Method 1 Method to 100 µg/l Fe (10-cm cell) Reagent Solution. Instrument Adapter Sample cell DR 6000 LZV

DRAFT EAST AFRICAN STANDARD

Determination of Chromium in Gelatin Capsules using an Agilent 7700x ICP-MS

METHOD 3015A MICROWAVE ASSISTED ACID DIGESTION OF AQUEOUS SAMPLES AND EXTRACTS

Hach Company TNTplus 835/836 Nitrate Method Spectrophotometric Measurement of Nitrate in Water and Wastewater

Nitrogen total LR VARIO TT mg/l N b) Persulphate Digestion

Cadmium and lead content

High purity acids and bases

PQRI PODP Extractables & Leachables Workshop

Traceability, validation and measurement uncertainty 3 pillars for quality of measurement results. David MILDE

International Journal of Pharmaceutical Research & Analysis

Proposed Procedures for Determining the Method Detection Limit and Minimum Level

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Examples of Method Validation Studies Conducted in Different Economies

Stability of pharmaceutical preparations

CHEMISTRY DEPARTMENT

Preparation of Food and Feed Samples for Metals Analysis

ALLOWAY METHOD OUTLINE

RayBio Human Thyroid Peroxidase ELISA Kit

American Environmental Testing Laboratory Inc.

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Quality Assurance is what we do to get the right answer for our purpose FITNESS FOR PURPOSE

DISCLAIMER: This method:

PTG-NIR Powder Characterisation System (not yet released for selling to end users)

lems. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement task.

Tomorrow s quantitation with the TSQ Fortis mass spectrometer: quantitation of phenylephrine hydrochloride for QA/QC laboratories

A validated flame AAS method for determining magnesium in a multivitamin pharmaceutical preparation

PAR Method Method to 2.0 mg/l Pb TNTplus 850

RayBio Rat TNF-alpha ELISA Kit (For Lysates)

The kit is a sandwich enzyme immunoassay for in vitro quantitative measurement of prolactin in porcine serum, plasma and other biological fluids.

Appendix II- Bioanalytical Method Development and Validation

CCME Reference Method for the Canada-Wide Standard for Petroleum Hydrocarbons (PHC) in Soil - Tier 1 Method

Total Dissolved Residue (Total Dissolved Solids, TDS) in Aqueous Matrices

NATIONAL ASSOCIATION OF TESTING AUTHORITIES (NATA) REQUIREMENTS FOR ACCREDITATION OF ICP-MS TECHNIQUES

Not Just for Paint Chips Anymore. High Throughput, Open Vessel Microwave Digestion of Matrices Requiring Moderate Conditions

Determinations by Atomic Absorption Spectroscopy and Inductively Coupled Plasma-Atomic Emission

Savillex Technical Note Performance of the DST-1000 Acid Purification System

Determination of Elemental Impurities Ciprofloxacin hydrochloride and Fluconazole via ICP-OES

METHOD 7060A ARSENIC (ATOMIC ABSORPTION, FURNACE TECHNIQUE)

WHAT YOU NEED. Visible Spectrophotometer. Micropipettes. Cuvettes. Parafilm. Timer µL

Laboratory Analytical Data

Bovine FSH(Follicle Stimulating Hormone) ELISA Kit

CERTIFICATE OF ANALYSIS Nitric Oxide Assay Kit

Schedule. Draft Section of Lab Report Monday 6pm (Jan 27) Summary of Paper 2 Monday 2pm (Feb 3)

Multi-Element Analysis of Cannabis using the Agilent 7800 ICP-MS

Level 1 Science, 2011

World Journal of Pharmaceutical and Life Sciences WJPLS

Powder Pillows 0.01 to 0.80 mg/l Al 3+ (colorimeters)

Protein Quantification Kit (Bradford Assay)

Sheep myeloperoxidase(mpo) ELISA kit

Strategies for Determination of Elemental Impurities in Complex Samples

Ustekinumab Drug Level ELISA

Determination of major, minor and trace elements in rice fl our using the 4200 Microwave Plasma- Atomic Emission Spectrometer (MP-AES) Authors

Metanephrine Normetanephrine ELISA GWB-D75242, Legacy ID RESEARCH USE ONLY

Hydrogen Peroxide Colorimetric Detection Kit

Simultaneous Estimation of Residual Solvents (Isopropyl Alcohol and Dichloromethane) in Dosage Form by GC-HS-FID

Method for estimation of iodine in urine

Colorimetric Method Method to 0.70 mg/l Ag Powder Pillows

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

3.0 APPARATUS : Capsule Machine, Analytical balance, Spatula, Beaker, Pestle and mortar, Powder paper.

Basic Digestion Principles

Cleaning Memo for January 2017 A Critique of the APIC Guideline

Cadion Method Method to 0.30 mg/l Cd TNTplus 852

Additionally, minor editorial changes have been made to update the monograph to current USP style.

Transcription:

Concept of Elemental Impurities (EI) assessment in finished dosage forms by total extraction testing W. Keurentjes, F. Maris, T. Wang, M. van Tiel Merck & Co.

Content Introduction How did we start Straight forward procedure Feasibility study total extraction Results Validation aspects Conclusions

Introduction Wilfried Keurentjes ICP-MS laboratory Merck & Co. - The Netherlands Merck & Co. platform for implementing EI Two approaches: Option 1: API/Excipient gathering info Option 2: Finished dosage form testing

How did we start Option 1: collection EI information of all APIs/Excipients Incoming materials approach Over 50 sites with more than 100 drug products Over 5000 excipients and API s Many different suppliers/production locations for excipients It was impossible to get the information on EI from the excipients suppliers (since they are on the same compliance schedule as we are) and the quality of the information we did receive was questionable. Will this approach give full information on a finished dosage form?

Straight forward procedure Option 2: Approach finished dosage form (DP) testing Analyze 3 commercial batches of each DP worst case strength Option: use stability batches as worst case e.g. include migration of EI from the primary packaging (according guideline not mandatory) Different batches excipients, API e.g. use 1, 2 and 3 year old stability samples (for products with shelf life >= 36 months) Use one standardized, straight forward analytical procedure Execute as limit test on 30% requirement Execute sample related validity tests during analysis

Straight forward procedure To cover the wide range of Merck products and PDEs (based on routes of administration and daily dose) we selected ICP-MS as the technique of preference. Experience with ICP-MS analysis is available at several labs at Merck. Experience on sample prep of drug products is limited. Therefore a feasibility study was started

Feasibility study One sample prep (and ICP-MS) method for all our products addressing all class 1 to 3 elements! Method must be efficient and cost effective Sample prep options: Total analysis For many products microwave digestion is needed which is very laborious Gastrointestinal extraction No clear guidelines and only suitable for oral products Simplified nearly total extraction 80% of concentrated nitric acid at room temperature over 16+ hours.

Feasibility study Standardized method: Put product in a tube (duplicate + standard addition) Add 5 ml water disintegrate / dissolve Add 20 ml conc. Nitric acid for a final concentration of 80% nitric acid dissolve / extract / digest Shake the samples for over 16 hours (overnight) and settle. Dilute if necessary Analyze all products in one ICP-MS run

total -extraction Pro Strong acid will dissolve most salt or metals Digest or dissolve many organic compounds. Efficient Con Safety precautions (nitrous oxide fumes) Not always a total extraction but the method is fit for purpose

total -extraction Main question. Is total analysis required? E.g. elements locked into a lattice might not be relevant because they will not be absorbed. (Q3D tox studies mainly used readily available salts) Statement: The 80% of concentrated nitric acid medium will be used to distinguish relevant and not relevant parts, since it is a very vigorous medium. The method is fit for purpose

Results of the Feasibility Study The study has been performed on 16 chosen (parenteral/oral/special) products

Results of the Feasibility Study All selected products comply with 30% PDE rule using the 10 g/day option. simplify lab calculations not applicable for all products e.g. inhalator, implants? Efficient: During this first study of 4 days, 16 products were analyzed in duplicate and a spike addition. Analytical, some minor issues

Results of the Feasibility Study Not all products did dissolve. Polymeric Dissolving is not needed. Oil products Shaking during 16 hours of extraction to assure good contact between product and acid medium for all products will be added to the method

Results of the Feasibility Study Lithium sensitivity is lower than other elements. But 30% of limits can be achieved Re-analysis of QC-standard 10 ng/ml during run gave some deviations > 20% for Li and Os Some recoveries deviate from 80-120% (As, Ag, Os, Pd, and Li) addition of 0.5% hydrochloric acid to the acid medium would mitigate Blank level of Pb is raised 1 ng/ml. Controlling contamination is a day to day responsibility of the lab.

Validation aspects Validation aspect During analysis (on samples) Accuracy Spike recovery 70 150% Drift QC sample NMT 20% Validation report (on solutions) Precision - repeatability Two solutions in six fold - NMT 20% 1. High salt matrix 2. High carbon matrix Precision - ruggedness As repeatability, over three days - NMT 25% Specificity Limit of Quantitation Linearity / Range r > 0,99 (no need for ½J / 2J) (Elemental) interferences 1. High salt matrix 2. High carbon matrix 30% of 0,5 of lowest J must comply At least from 30% of 0,5 of lowest J to 2 times highest J r > 0,99

Conclusion Assessment of elemental impurities in finished dosage forms by total extraction testing - Method proved to work on 16 products - Efficient - Holistic results including factors as API, excipients, environment, prim. packaging and stability.

Questions, Remarks