Coating Thickness Gauge TW-8. art. nr Thoma Tel./Fax: Operation Manual

Similar documents
VIBRATION METER. Instruction Manual.

MN-ISO-2000FN-E. ISO-2000FN COATING THICKNESS GAGE OPERATION MANUAL

Mini Environmental Quality Meter

Today s Weather 24 Hour Forecaster

DIAGNOSTICS NO TOUCH FOREHEAD THERMOMETER

INFRARED THERMOMETER Model : TM-959

Hadrons Desktop U.S. Atomic Clock & Weather Station

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

MANUAL TT-220 TT-220

InfraRed Thermometer with Laser Pointer

VIBRATION METER Acceleration & Velocity Model : VB-8201HA

INSTRUCTION MANUAL Milwaukee Refractometer MA881 Refractometer for Invert Sugar Measurements

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

INSTRUCTION MANUAL DTH Fax: (503)

2 ACCESSING VARIOUS MODES

U.S. Atomic Clock & Weather Station. Instruction Manual

MODE button MAX/MIN button CHANNEL button / C/ F / RCC button SNOOZE / LIGHT button Battery compartment A/C in-jack 3. 4.

6.Ebz!boe!8.Ebz!!! Gpsfdbtufst!!! G U I D E n catio Lo

IR/Thermistor Pen. Instruction Manual

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

рн PRO Controller The device is used to control and regulate ph level in hydroponic systems and water preparing units automatically USER MANUAL

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

SkyScan EWS-PRO - Manual -

Wireless Weather Station Instruction Manual

Dewpoint Meter Data Sheet / Instructions


Instruction Manual HI Refractometer for Sodium Chloride Measurements

Dual laser + type K thermometer INFRARED THERMOMETER

OPERATION MANUAL. Acceleration, Velocity RMS measurement, Metric & Imperial unit PEN VIBRATION METER Model : PVB-820

Infrared / K Thermometer Remote Temperature Measurement ( Non-Contact ) 1327K INSTRUCTION MANUAL

Data Sheet / Instructions. Dewpoint MeterO

WT-3131A Radio-controlled Analog Clock With Weather Forecast. Instruction Manual

TECHNICAL MANUAL 820 LX / 910 LX / 1300 LX

WS-7047TWC Wireless 433 MHz Weather Station With Rainfall and Temperature. Instruction Manual

Non - Contact Forehead Infrared Thermometer. Care Q7 USER MANUAL - 1 -

WeatherHub2 Quick Start Guide

TG646 WEATHER STATION

Instruction Manual HI Refractometer for Invert Sugar Measurements

ShowCUBE. ShowCUBE DMX RGBWA+UV Eternal Lighting Updated 01/2015

473-SHX Dew Point Mirror

ea980r Digital Anemometer User Manual

WS-7038U Wireless 433 MHz Miniature Rain Monitor. Instruction Manual

Acceleration, Velocity, Separate probe VIBRATION METER Model : VB-8202

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

XR Analog Clock - Manual Setting Model Troubleshooting Guide

Operating instructions Magnetic-inductive flow sensor SM6004 SM7004 SM / / 2014

CONTENTS. Batteries. La Crosse Technology, Ltd Page 1

Operating Instructions 5 Day Weather Station with Color Screen Model: DG-TH8805 INDOOR UNIT

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

INSTRUCTION MANUAL Milwaukee Refractometer MA888 Refractometer for Ethylene Glycol Measurements

Acceleration/Velocity/Displacement VIBRATION METER

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Model: WT-3181PL Instruction Manual DC: Indoor/Outdoor Atomic Wall Clock. Get Started

DM70. Hand-held Dewpoint Meter. Truly Fast Response - Superior Long-term Stability

Medium Pressure Sensor Analog Output

New! 2010 Model. Model No

PAR Meter Instruction Manual. Product # Product # Year Warranty

Bright Advance Corporation

INSTRUCTION MANUAL Fax: (503)

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

WS-9018U Wireless Weather Station. Instruction Manual

HI Propylene Glycol Refractometer INSTRUCTION MANUAL

One-Year Limited Warranty

INSTRUCTION MANUAL Milwaukee Refractometer MA886 Refractometer for Sodium Chloride Measurements

product manual H-3220A Benkelman Beam

B Left-hand case side (x1) F

Ultrasonic Thickness Gauge TIME2110 (V )

Instruction Manual. Solar Weather Centre With Wireless Weather Vane. Product Code: WS5056C. Solar Powered Outdoor Weather Data Collector

Bante210 Benchtop ph Meter Instruction Manual

Portable ph/orp/ion Meter D-73 Instruction Manual CODE:GZ A

Instruction Manual HI Refractometer for Sucrose in Wine and Grape Products Measurements

Operating Instructions for Digital Manometer. Model: MAN-SD

INSTRUCTION MANUAL Milwaukee Refractometer MA872 Refractometer for Fructose Measurements

Instruction Manual SEFRAM Thermal Camera

HI Refractometer for Sodium Chloride Measurements INSTRUCTION MANUAL

QUANTUM CONCEPT. Swimming User s Manual

HS515G-M. PARALOW Circle Dot Sight. User's Manual. Holosun Technologies Inc. Phone: (909) Fax: (909)

ROMEO ROMEO6 1x30mm FULL SIZE RED DOT SIGHT

Ultrasonic Thickness Gauge TT130 TIME Group Inc. Beijing TIME High Technology Ltd.

Vet Photometer DP 700 Operating Manual. Version V5.9

566/568. Infrared Thermometers. Getting Started

Anemometer Thermometer Hygrometer

u s e r m a n u a l w w w. v e l a. E U

WS-7211U Wireless 433 MHz Weather Station. Instruction Manual

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

Telescopic auto dimension measuring system

Wireless Color Forecast Station Model: K86319

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

473 Dew Point Hygrometer

ph 5 Meter Manual The LaMotte 5 Series

Operator's Manual. optris BR 400. Calibration source

INSTRUCTION MANUAL ANALOG COLORIMETER

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL. Milwaukee Refractometer

HI Propylene Glycol Refractometer

Transcription:

Coating Thickness Gauge art. nr. 59252

Table of contents 1. Technical specifications...3 2. Getting started...3 3. Gauge manual...6 The price of this product includes the recycling fee of 0,10 PLN Guarantee...11 Before You start to use the device, please read this operation manual. 2

1. Technical specifications Basic specifications of the device: measurement on steel, galvanized steel and aluminum; measurement resolution: 1 or 10µm (selected in menu); measurement range: from 0µm to 2000µm; measurement pause (hold function); assistant function; helpful in quality assessment; sound notification; memory up to 200 measurements; zeroing function; LCD back light (turned on in menu); flexible measuring sensor; intuitive operation with 11-positions menu; automatic shut-off after longer idleness; powered by two 1,5V AAA, R2 alkaline batteries or two compatible rechargeable batteries AAA, R3; low battery indicator; 3 language operation (Polish, English, German); 24 months guarantee. Set includes: Meter ; resetting plate; case; battery; manual. zeroing plate; 2. Getting started Coating thickness gauge is designed to measure the thickness of a steel, galvanized steel or aluminum sheet paint coating. It also helps to verify the authenticity of e.g. car documents or 3

banknotes thank to built-in UV tester. The measurement resolution equals 1 or 10µm (selected in menu). The device features an EEPROM memory for 200 measurements. The measurement s results are stored also when the gauge is off which enables to look through them after the measurements are done. They can be deleted from the main menu level. The Hold function enables to keep the measurement result on screen even after the sensor is taken away from the specimen. The device has a LCD back light which makes measuring in places with insufficient light (e.g. garage) much easier. hank to improved technical solutions, the gauge s power consumption is very slight. It takes only 1 AAA, R3 alkaline battery for dozen or more continuous working hours. The device is equipped with a modern and fast microprocessor. The thickness measurements are made using third level approximation algorithms combined with multiple calibration points. It provides high accuracy of measurement results especially in comparison with simple, linear approximation solutions.. Zeroing (calibration) Before You start to take measurements, please check whether the gauge is calibrated. To do it properly, please select the Zero function from the main menu and put the sensor against the calibration sheet for around 2 seconds. If the display shows a 0 +/-10µm value, it means that the gauge is calibrated (in this case press the [] button to return to main menu). Should the aberration be larger than 0 +/-10µm, the device needs to be calibrated. In order to do this press the button. On the display appears a ==>0<== caption. Push the sensor against the calibration sheet and hold it. The calibration progress will be shown on the display (33%, 66%, 100%). After the procedure... caption appears and You will hear a sound signal. The device returns to Zero function where You can check if the calibration has been done properly. After pressing [] the device returns to the main menu. ==>0<== 4

CAUTION! Whi l e z e r o i n g, t h e c a l i b r at i o n s h e e t s h o u l d b e p l a c e d o n a f l at, s ta b l e n o n-me ta l i c s u r fa c e (e.g. d o n o t p l a c e t h e s h e e t o n t h e b o d y w o r k). Al s o, p l e a s e a v o i d h o l d i n g t h e s h e e t in Your hands as this may affect the operation. Please note that zeroing is recommended when the measurement conditions are changing (e.g. the temperature or humidity rises or falls). Changing the battery If the battery is low it needs to be replaced immediately. Take away the battery cover placed in the back of the device and replace the battery. Please use only type AA (R6) alkaline batteries or fully charged compatible rechargeable battery. CAUTION! 1. Us e o n ly a l k a l i n e b at t e r i e s a s n o r m a l b at t e r i e s p r o v i d e i n s u f f i c i e n t p o w e r. 2. In s t e a d o f a a l k a l i n e b at t e ry You ca n us e a co m p at i b l e, f u l ly ch a r g e d ac c u. To take a measurement please put the device s sensor against the examined surface. The sensor should adhere as flat as possible. The examined surface should be clean and smooth, otherwise the measurement result may be incorrect. It is recommended to hold the gauge with both hands and press gently towards the examined surface to eliminate vibration. Usually it takes 1-2 seconds to stabilize the measurement result. 5

3. Gauge manual The device is operated with 2 buttons: button []: turns the device on, accepts the selected functions and returns from them to the main menu, when pressed during the measurement it memorizes the displayed value; button FUNCTION: switches between the functions in the main menu, switches between the stored measurement values. To turn the gauge on please press the [] button for about 1 second. After displaying the company s logo and the device s type, the device switches automatically to the main menu. The > symbol indicates the currently selected function. Please press the button to switch between the following functions. Please press the button to switch between the following functions: Measur measure function: takes measurements; Subst - ubstance function: allows to choose the measured material Memory memory function: recalls the stored measurement values; Off off function: switches the device off; Delete delete function: deletes the stores measurement values; Zero zeroing function: calibrates the device; Hold hold function: freezes the measurement result on the display; Resol. resolution function: switches between the measurement resolution; Assist. - assistant function: enables to value the quality of measured object LCD LED back light function: turns the display back light on or off; Lang. language function: switches between languages. To select a function please press the [] button. Measure function - Measur fter You select this function the display will show the currently selected material, e.g. Zn/Al and the battery indicator in the first line and ----um in the second. The gauge is ready to take measurement. Zn/Al *140um After You put the sensor against the bodywork the result of the measurement will be shown on the display in the second line. If the Hold 6

function is enabled the result will be refreshed every 1 2 seconds. After disabling the Hold function it will be shown in real-time. To store the measurement result press the [] button. The * caption will appear next to the result confirming that it has been stored. CAUTION! The d e v i c e s s t o r a g e c a pa c i t y e q u a l s 200 r e s u lt s. Aft e r e x c e e d i n g t h e c a pa c i t y t h e o l d e s t r e s u lt s will be overwritten automatically! After You finish taking the measurements please return to the main menu with pressing the [] button. Memory function - Memory This function allows You to recall the latest measurement values. Please press the button to switch between the stored results. The first displayed result is the oldest one. After You get to the last result the device returns automatically to the first one. To return to the main menu please press the [] button. Off function - Off After You accept this function with the [] button the device turns off. 1: 140um >Off Delete Substance function - Subst The substance function allows You to choose the material which will be measured. You have the following possible choices: galvanized steel / aluminium ( Zn/Al); steel ( Fe); reference point ( Ref) >Zn/Al Fe You can switch between the sheet materials with the button, to accept the selection press the [] button. 7

Delete function - Delete Choose this function to delete all measurement values stored in the device s EEPROM internal memory. After deleting the stored results the device returns to the main menu automatically. >Delete Zero Zeroing function - Zero Before You start to take measurements, please check whether the gauge is calibrated. To do it properly, please select the Zero function from the main menu and put the sensor against the calibration sheet for around 2 seconds. If the display shows a 0 +/- 10µm value, it means that the gauge is calibrated (in this case press the [] button to return to main menu). Should the aberration be larger than 0 +/-10µm, the device needs to be calibrated. In order to do this press the button. On the display appears a ==>0<== caption. Push the sensor against the calibration sheet and hold it. The calibration progress will be shown on the display (33%, 66%, 100%). After the procedure... caption appears and You will hear a sound signal. The device returns to Zero function where You can check if the calibration has been done properly. After pressing [] the device returns to the main menu. CAUTION! Whi l e z e r o i n g, t h e c a l i b r at i o n s h e e t s h o u l d b e p l a c e d o n a f l at, s ta b l e n o n-me ta l i c s u r fa c e (e.g. d o n o t p l a c e t h e s h e e t o n t h e b o d y w o r k). Al s o, p l e a s e a v o i d h o l d i n g t h e s h e e t in Your hands as this may affect the operation. ==>0<== ==>0<== 33% ==>0<== 66%... 100% Please note that zeroing is recommended when the measurement conditions are changing (e.g. the temperature or humidity rises or falls). Hold function - Hold This is a feature of high-end devices. It enables to take the measurement and freeze the result on the display even after taking the sensor away from the specimen. If You turn this function off, the results will be displayed in real-time. Hold on 8

To activate select the Hold function from the main menu and choose Hold on by pressing the button. Confirm the selection with the [] button. To turn it off, choose Hold off. Resolution function - Resol. The gauge enables to choose between 2 measurement resolutions chosen with the button: D=10 the measurement is rounded up to 10µm (faster) D=1 the measurement is accurate up to 1µm (precise) Resol. D=10 For car paint coating thickness D=10 setting is good enough. Assistant function The function enables to interpret correctly if the measured body-work has ever been repaired. While the measurement is taken and the Assist. function is on, following phrases may appear: LITTLE the layer of paint is too thin LAC. the layer is correct 2xLAC! two layers of paint PUTTY! - putty Assist. on For technical reasons the mentioned phrases are abbreviations. The producer reserves the right to reduce or increase the number of compartments in the process of modernization of the device. The assistant function is to be helpful in the measurements interpretation. It cannot be the only hint to decide if the body-work has or has not been repaired. However many people who use the device claim that it is helpful in interpreting the results. Back light function - LCD LED Improves the display visibility in insufficient light conditions. To activate select the LCD LED function from the main menu and choose LCD LED on by pressing the button. Confirm the selection with the [] button. To turn it off, choose LCD LED off. LCD on LED 9

Language function You can choose out of 3 built-in menu languages: Polski - Polish, Eng. - English Deutsch - German. Select the language with the button and confirm the choice with the [] button. *Eng. Deutsch 10

Guarantee Guarantee 1. 2. 3. 4. 5. 6. 7. 8. 9. The guarantee period of this device is 24 months from date of purchase. Within this period the Producer guarantees a reliable function of the device, if operated correctly. The Producer takes responsibility for all workmanship or material defects. All defects will be repaired within 30 days since the device has been accepted by the Service. The guarantee period will be prolonged by the time the device has been handled by the Service. The device shall be delivered to the Service with all the standard equipment, clean and with readable button s description. The guarantee will be treated as valid only with the date of purchase and with the stamp, or signature of the Producer filled out. In case the device has to be shipped to the Producer, it happens on the shipper s responsibility and cost. The device will be not accepted by the Service if pt. 6 is not kept, if the defect is of no workmanship or material nature, if the warranty card is not filled out, or the device is delivered with broken seal. 10. This guarantee shall not apply to damage caused through fire, accident, misuse, incorrect adjustment or repair, installation, modifications, or use in an improper way or inconsistent with the technical and safety standards required for it s operation. 11. All defects mentioned in pt. 10 can be repaired, if previously agreed with the Service. The cost depends on the nature of the defect. 12. After the guarantee period expires, defects can be repaired, if previously agreed with the Service. The cost depends on the nature of the defect. 13. The guarantee is only valid with filled out date of purchase, stamp or signature of the Producer and with an appropriate receipt. Date of purchase Stamp / Signature