Recommended tools and devices: spectrophotometer Spekol, cuvettes, set of chromatic solutions varying in concentration, distilled water

Similar documents
Recommended tools and devices: spectrophotometer Spekol, cuvettes, set of chromatic solutions varying in concentration, distilled water

Measurement of selected microclimatic factors

Measurement of selected microclimatic factors

EXPERIMENT #3 A Beer's Law Study

Determination of the Equilibrium Constant. HIn - + H 2 O = H 3 O + + In 2-, [H 3 O + ][In 2- ] K ai = [HIn - ]

Lab 5: Calculating an equilibrium constant

Beer's Law and Data Analysis *

CHEM Lab 7: Determination of an Equilibrium Constant using Spectroscopy

Preparation of Standard Curves. Principle

Determining the Concentration of a Solution: Beer s Law

Spectrophotometry. Introduction

Basic Instrumentation. Learning Objectives:

Concepts, Techniques. Concepts, Techniques 9/11/2012. & Beer s Law. For a simple, transparent, COLORED material, e.g. ROYGBV

Spectrophotometry Materials

MORE LIGHTS, COLOR, ABSORPTION!

Chemistry 1210 Quantitative Determination of a Two-Component System

Lab #12: Determination of a Chemical Equilibrium Constant

CHEM 254 EXPERIMENT 9. Chemical Equilibrium-Colorimetric determination of equilibrium constant of a weak acid

VISIBLE SPECTROSCOPY

Determining the Concentration of a Solution: Beer s Law

Skill Building Activity 2 Determining the Concentration of a Species using a Vernier Spectrometer

INTRODUCTION The fundamental law of spectrophotometry is known as the Beer-Lambert Law or Beer s Law. It may be stated as: log(po/p) = A

Experiment 6: Determination of the Equilibrium Constant for Iron Thiocyanate Complex

9 Equilibrium. Aubrey High School PreAP -Chemistry. Name Period Date / /

Investigating Transition Metal Complexes

Introduction. The amount of radiation absorbed may be measured in a number of ways: Transmittance, T = P / P 0 % Transmittance, %T = 100 T

Experimental Procedure Overview

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Spectrophotometric Determination of Iron

Experiment 13. Dilutions and Data Handling in a Spreadsheet rev 1/2013

Chemistry 141 Laboratory Spectrometric Determination of Iron Concentration Lab Lecture Notes 8/29/2011 Dr. Abrash

S2. INTRODUCTION TO ULTRA-VIOLET / VISIBLE SPECTROSCOPY

SPECIALIZED LABORATORY of pharmaceuticals manufacturing

aa + bb cc + dd Equation 1

Experiment 2: The Beer-Lambert Law for Thiocyanatoiron (III)

Rate law Determination of the Crystal Violet Reaction Using the Isolation Method

ATOMIC PHYSICS PHOTOELECTRIC EFFECT Practical 2 DETERMINATION OF PLANCK S CONSTANT BY MEANS OF THE STOPPING POTENTIAL

The Determination of an Equilibrium Constant

EXPERIMENT 12 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of a Commercial Aspirin Tablet

Concentrations that absorb. Measuring percentage transmittance of solutions at different concentrations

MOLEBIO LAB #4: Using a Spectrophotometer

Introduction to Spectroscopy: Analysis of Copper Ore

Beer-Lambert law Decomposition of the manganese oxalate ion

Spectrophotometry. Dr. Shareef SHAIK ASST. PROFESSOR Pharmacology

Beer's- Lambert Law and Standard Curves. BCH 312 [Practical]

Experiment 7A ANALYSIS OF BRASS

Chem 310 rd. 3 Homework Set Answers

Determination of the Solubility-Product Constant for a Sparingly Soluble Salt

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Determining the Concentration of a Solution: Beer s Law. Evaluation copy. Figure 1

Activity 4: The Electric-Circuit Interaction

Determination of an Equilibrium Constant

Lab Investigation 4 - How could you make more of this dye?

C.S.Rye: Mascot Murder Mystery

D E T E R M I N A T I O N O F K e q L A B

Biology 3B LABORATORY Quantitative determination of chlorophyll using spectroscopy

For simplicity, we ll represent BTB s ionization in a solution by the equilibrium: HBTB = H + + BTB -

Chemistry 213. A KINETIC STUDY: REACTION OF CRYSTAL VIOLET WITH NaOH LEARNING OBJECTIVES

CH 2212 Lab Exploration Standard Addition in Spectrophotometry

This activity has been password protected to prevent modification. In order to request an unprotected version of this activity, contact

Introduction to Spectroscopy: Analysis of Copper Ore

2014 NJIT RET Program. MODULE TOPIC: Two Methods of Determining the Concentration of Soluble Compounds or Analytes..

EXPERIMENT 14. ACID DISSOCIATION CONSTANT OF METHYL RED 1

EXPT 11. pk a of ph Indicators

Lab #16: Determination of the Equilibrium Name: Constant of FeSCN 2+ Lab Exercise. 10 points USE BLUE/BLACK INK!!!! Date: Hour:

GENERAL PHARMACOPOEIA MONOGRAPH

1 st European Union Science Olympiad in Dublin, Ireland. task B

Experiment 12H, Parts A and B

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

PRELIMINARY ACTIVITY FOR

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Spectroscopy. Page 1 of 8 L.Pillay (2012)

C101-E107B UV Shimadzu UV-VIS-NIR Spectrophotometer

Experiment 1 Chemical Kinetics 1

Chemistry 1215 Experiment #11 Spectrophotometric Analysis of an Unknown Brass Sample

Bio 120 Lab 5: Quantitative Analysis

Photochemistry of Nitro-Polycyclic Aromatic Hydrocarbons. August 9, 2011

SPECTROPHOTOMETRY/BEER S LAW LECTURE HONORS CHEMISTRY NAME

Introduction to Spectroscopy: Analysis of Copper Ore

Experiment 18 - Absorption Spectroscopy and Beer s Law: Analysis of Cu 2+

Exp 03 - Reaction Rate

Experiment 11 Beer s Law

Kinetics of Crystal Violet Bleaching

Experiment 11 Beer s Law

MEASUREMENT: PART II

The Determination of an Equilibrium Constant

Experiment 13H THE REACTION OF RED FOOD COLOR WITH BLEACH 1

UV/VIS SPECTROMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT

Ocean Optics Red Tide UV-VIS Spectrometer (Order Code: SPRT-UV-VIS)

Experiment 13I THE REACTION OF RED FOOD COLOR WITH BLEACH 1

Three hour lab. Chem : Feb Experiment 2 Session 2. Experiment 2 Session 2 Electrons and Solution Color

Introduction to biochemical practicals. Vladimíra Kvasnicová

Equilibrium and Ionic Strength Effects

EXPERIMENT 5: PHOTOMETRIC DETERMINATION OF AN EQUILIBRIUM CONSTANT

SCHOOLS ANALYST COMPETITION 2012 MIDLANDS REGIONAL HEAT INSTRUCTION BOOKLET ROYAL SOCIETY OF CHEMISTRY ANALYTICAL DIVISION

COLORIMETER AND LAMBERT S-BEER S LAW. Shingala vaishali Sandha prafulla Tiwari Kuldeep

Physics 1CL OPTICAL SPECTROSCOPY Spring 2010

The ROXI Colorimeter & Fluorimeter. Laboratory Application I. Colorimetric measurements via Beer s Law.

Using the ALTA Handheld Reflectance Spectrometer

Three hour lab. Chem : Sept Experiment 2 Session 2. Preparation Pre-lab prep and reading for E2, Parts 3-5

Transcription:

16_Spectrophotometry.xlsx/Work procedure Study group: Year of study: Objective: Establish the unknown concentration of a solutionusing absorption of light. Tasks: 1. Measure the absorbance and transmittance of solutions with different known concentrations using the spectrophotometer Spekol.. Draw calibration curves expressing the dependence of absorbance and transmittance to the concentration of solutions. 3. Measure the absorbance and transmittance for a solution of unknown concentration. 4. State the unknown concentration of the solution from both calibration curves due to measured absorbance and measured transmittance. Compare the results. 5. Explain the obtained results and possible differences. Recommended tools and devices: spectrophotometer Spekol, cuvettes, set of chromatic solutions varying in concentration, distilled water Procedure: 1. Work alone.. Turn the light source of spectrophotometer on. 3. Adjust the screw of monochromator in order to set the appropriate wavelength λ (if yellow colour solutions are used, select λ = 49 nm). 4. Check the cleanness of the cuvettes. Do not touch them on glossy surface, only on the rough ones. If needed, clean the glossy surface. 5. Calibrate the spectrophotometer: a) Switch the light shutter (on the bottom left) to the position "". This closes the slit of the monochromatic light. b) Line the needle of the potentiometer (use the adjuster at the right top labeled "") to the % position at the lower scale (transmittance T (resp. ϑ) = %), which equals to absorbance (extinction) A (or E ) =. c) Switch the light shutter to the position "I". This opens the slit of the monochromatic light. d) Fill the cuvette with distilled water and put it into the moveable holder. Shift the holder with cuvette in front of the light slit. e) Line the needle of the potentiometer (use the adjuster at the right top labeled "1") to position 1% at the lower scale (transmittance T, respectively. ϑ = 1%) which equals to the absorbance (extinction) A = (or E = ). f) Repeat the calibration (items a e) once more. 6. Fill next cuvette with the solution of the lowest available concentration. 7. Put the cuvette into the moveable holder and shift the holder (with the cuvette) in front of the light slit. 8. Read the absorbance and transmittance values from the scales. 9. Write the measured values into Table 1. 1. Repeat the measurement (items 7 9) for the solution with the next lowest concentration. Before each measurement, repeat the calibration (item 5). 11. Repeat the measurement (items 7 9) for the solution of the unknown concentration. Before the measurement repeat the calibration (item 5). 1. After the measurement, rinse the cuvettes with distilled water and let them drip. 9.9.16 1/5

16_Spectrophotometry.xlsx/Work procedure Study group: Year of study: 13. Draw graphs calibration curves of both dependencies (solution concentration dependence of transmittance and of absorbance). Use only the known concentrations of solutions. 14. Read the unknown concentration from both calibration curves according the measured values of transmittance and absorbance. Compare the obtained values. 15. Fill all entries in the "Results" (to verify the equivalence of the established values of transmittance and absorbance, you can use Figure 1). 16. Explain the results and discuss possible differences. Figure 1: Comparison of transmittance and absorbance. Applied equations: Lambert Beer's law: 1 where ε is the molar absorption coefficient for a given wavelength, c is a molar concentration and x is a total where I is the entering light intensity, I is the light intensity after passing through the layer % 1 % Note Orange painted cells have to be filled in BEFORE your arrival on practical training. Green painted cells have to be filled during the measurement, or later during protocol processing. Parts of the procedure denoted in italics designate your homework processing measurement results at home. 9.9.16 /5

16_Spectrophotometry.xlsx/Measurement sheet Study group: Year of study: Date of the measurement: I have studied the theory for practical training from: Time of the measurement: (specify a complete bibliographical reference including appropriate chapter and page designation) Used devices and tools: Microclimatic conditions of measurement: atmospheric pressure p = mmhg = kpa air temperature t = C relative humidity H rel = % Object of measurement: Characteristics of examined solutions: Measurement results: Table 1: Measured values of absorbance and transmittance for differenct solution concentrations. Measurement no. 1.. 3. 4. 5. 6. Concentration [mmol l 1 ] unknown Absorbance Transmittance [%] 1 Date and teacher's signature: 9.9.16 3/5

16_Spectrophotometry.xlsx/Results processing Study group: Year of study: Date of the measurement: Used devices and tools: Time of the measurement: 1 1 Microclimatic conditions of measurement: 1 atmospheric pressure p = kpa room air temperature t = C relative air humidity: H rel = % Object of measurement: Characteristics of examined solutions: 1 Measurement results: Table 1: Measured values of absorbance and transmittance for differenct solution concentrations. 3 Measurement no. 1.. 3. 4. 5. 6. Concentration [mmol l 1 ] unknown Absorbance Transmittance [%] 1 The unknown concentration of the solution determined according to Chart 1 and Chart (in protocol attachment) from the absorbance curve (c A ) and transmittance curve (c T ): c A = mmol l 1 c T = mmol l 1 Discussion: Physical principle of spectrophotometry. 3 Evaluation of measurement conditions, microclimatic factors and possible sourcesof measurement errors. Comparisson of particular collected values of examined solution concentration. 9.9.16 4/5

16_Spectrophotometry.xlsx/Results processing Conclusion: Results summary and biophysical interpretation. Possible application of spectrophotometry inmedicine. 3 References: Cite references in the correct form. NOTE: Obligatory protocol attachments are two hand drawn graphs of dependence of transmittance (absorbance) to solution concentration. *Optional protocol attachment is a computer processed graph of the dependencies stated above with labeled unknown concentration. 1 4 Score: Date and teacher's signature: Overall max. 33 Bonus max. 6 9.9.16 5/5