Emission spectrum of H

Similar documents
high temp ( K) Chapter 20: Atomic Spectroscopy

CH. 21 Atomic Spectroscopy

Ch. 9 Atomic Absorption & Atomic Fluorescence Spectrometry

Chemistry Instrumental Analysis Lecture 18. Chem 4631

3 - Atomic Absorption Spectroscopy

very high temperature for excitation not necessary generally no plasma/arc/spark AAS

Optical Atomic Spectroscopy

2101 Atomic Spectroscopy

9/13/10. Each spectral line is characteristic of an individual energy transition

10/2/2008. hc λ. νλ =c. proportional to frequency. Energy is inversely proportional to wavelength And is directly proportional to wavenumber

Atomization. In Flame Emission

Partial Energy Level Diagrams

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Atomic Absorption & Atomic Fluorescence Spectrometry

Atomic Absorption Spectroscopy (AAS)

Lecture 7: Atomic Spectroscopy

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

AN INTRODUCTION TO ATOMIC SPECTROSCOPY

a. An emission line as close as possible to the analyte resonance line

Chapter 8: An Introduction to Optical Atomic Spectrometry

PRINCIPLES OF AAS atomization flame furnace atomization absorption

ATOMIC SPECROSCOPY (AS)

ATOMIC ABSORPTION SPECTROSCOPY (AAS) is an analytical technique that measures the concentrations of elements. It makes use of the absorption of light

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

II. Spectrophotometry (Chapters 17, 19, 20)

INTRODUCTION TO OPTICAL ATOMIC SPECTROSCOPY (Chapter 8)

Atomic Emission Spectroscopy

Ch. 8 Introduction to Optical Atomic Spectroscopy

1. Cyclic voltammetry involves the measurement of a diffusion controlled at an electrode in which the is controlled. (4 points)

Atomic absorption spectroscopy

INTRODUCTION Atomic fluorescence spectroscopy ( AFS ) depends on the measurement of the emission ( fluorescence ) emitted from gasphase analyte atoms

CHAPTER 8 Introduction to Optical Atomic Spectrometry

A Spectrophotometric Analysis of Calcium in Cereal

atomic absorption spectroscopy general can be portable and used in-situ preserves sample simpler and less expensive

ENVG FALL ICP-MS (Inductively Coupled Plasma Mass Spectrometry) Analytical Techniques

Questions on Instrumental Methods of Analysis

UNIVERSITI SAINS MALAYSIA. Second Semester Examination Academic Session 2004/2005. March KAA 502 Atomic Spectroscopy.

Ionization Techniques Part IV

PRINCIPLE OF ICP- AES

Spectroscopy Problem Set February 22, 2018

FLAME PHOTOMETRY AIM INTRODUCTION

Atomic Spectroscopy AA/ICP/ICPMS:

Chapter 9. Atomic emission and Atomic Fluorescence Spectrometry Emission spectrophotometric Techniques

COMPARISON OF ATOMIZERS

Because light behaves like a wave, we can describe it in one of two ways by its wavelength or by its frequency.

Chem 155 Quiz 3 Review Topics: Quiz 3 outline

Course Details. Analytical Techniques Based on Optical Spectroscopy. Course Details. Textbook. SCCH 211: Analytical Chemistry I

Atomic Absorption Spectroscopy and Atomic Emission Spectroscopy

Chem 434 Instrumental Analysis Test 1

Atomic Absorption Spectrometer ZEEnit P series

Sample Copyright. Academic Group ATOMIC STRUCTURE 1. Topics covered in this chapter:

Chemistry Instrumental Analysis Lecture 17. Chem 4631

Chemistry Instrumental Analysis Lecture 34. Chem 4631

Atomic Absorption Spectroscopy

Application of IR Raman Spectroscopy

SELİN CANSU ÖZTÜRK ŞEYMA ATAKUL SEZİN GÜNER

Analytical Topics to Consider in preparation for the MFAT/GRE

VALLIAMMAI ENGINEERING COLLEGE SRM Nagar, Kattankulathur

Prof. Dr. Biljana Škrbić, Jelena Živančev

1. The range of frequencies that a measurement is sensitive to is called the frequency

Introduction to Spectroscopic methods

Spectrum of Radiation. Importance of Radiation Transfer. Radiation Intensity and Wavelength. Lecture 3: Atmospheric Radiative Transfer and Climate

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Lecture 3: Atmospheric Radiative Transfer and Climate

Spectroscopy. Page 1 of 8 L.Pillay (2012)

A very brief history of the study of light

HEAVY METALS IN LAKE NAKURU ATOMIC SPECTROSCOPY

Infrared Spectroscopy: Identification of Unknown Substances

Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy. Chemistry 311: Instrumentation Analysis Topic 2: Atomic Spectroscopy

Ch 313 FINAL EXAM OUTLINE Spring 2010

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

Chapter 8: Introduction to Atomic Spectrometry

MASTERING THE VCE 2014 UNIT 3 CHEMISTRY STUDENT SOLUTIONS

Classification of spectroscopic methods

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

A New Cross-Shaped Graphite Furnace with Ballast Body for Reduction of Interferences in Atomic Absorption Spectrometry

Sub-category: Physics and Principles of Measurement Topic: Monitoring anesthetic gases and vapours Date: January 15-17, 2016 Language: English

Two-electron systems

Ferdowsi University of Mashhad

Analytical Technologies in Biotechnology Prof. Dr. Ashwani K. Sharma Department of Biotechnology Indian Institute of Technology, Roorkee

Nuclear Magnetic Resonance Spectroscopy (NMR)

Chem 434 -Instrumental Analysis Hour Exam 1

Chemistry Instrumental Analysis Lecture 37. Chem 4631

ANALYSIS OF ZINC IN HAIR USING FLAME ATOMIC ABSORPTION SPECTROSCOPY

Lecture- 08 Emission and absorption spectra

The Fundamentals of Spectroscopy: Theory BUILDING BETTER SCIENCE AGILENT AND YOU

Analytical Spectroscopy Review

Instrumental Analysis: Spectrophotometric Methods

CHEM 221 Instrumental Analysis FINAL EXAM May 10, 2016

Spectroscopy. Practical Handbook of. J. W. Robinson, Ph.D., D.Sc, F.R.C.S. Department of Chemistry Louisiana State University Baton Rouge, Louisiana

Lecture No. 4. i 0 TETA I RY:

EMISSION SPECTROSCOPY

Rb, which had been compressed to a density of 1013

Chapter 13 An Introduction to Ultraviolet/Visible Molecular Absorption Spectrometry

CHAPTER 1. MEASURES OF ATMOSPHERIC COMPOSITION

PAPER No.12 :Organic Spectroscopy MODULE No.29: Combined problem on UV, IR, 1 H NMR, 13 C NMR and Mass - Part I

Chapter 4. Spectroscopy. Dr. Tariq Al-Abdullah

High Pressure/Performance Liquid Chromatography (HPLC)

Chem 321 Name Answer Key D. Miller

Transcription:

Atomic Spectroscopy Atomic spectroscopy measures the spectra of elements in their atomic/ionized states. Atomic spectrometry, exploits quantized electronic transitions characteristic of each individual element in their atomic or ionic state. Transitions occur in the UV, VIS and NIR regions of the electromagnetic spectrum. It is valence electronic transitions of atoms/ions that is being exploited. This requires each atom to be isolated from all others, so the transitions are not perturbed by neighboring atoms or by bonding effects. Otherwise the resulting spectra are representative more of molecules or molecular fragments than of atoms themselves. Atomic spectral profiles are very narrow. Emission spectrum of H No vibrational or rotational quantization in atoms or their ions. Therefore lines from individual atomic species rarely overlap with one another. Thus broadening due to overlap of adjacent transitions do not exist. In AA absorption and emission spectral profiles are very narrow. 1

AES AAS AFS Analyte cell Origins of AS traced to flame test. Conventional sample cell - flame. 2300-2600 o C O 2 -C 2 H 2 flame Sample: salts- element existing as ions or compounds where the element of interest is bonded. Sample must be decomposed to the greatest extent possible into its constituent atoms/ions. Ideally, this atomization step should be quantitative; there should be no residual bonding in the gas-phase atomic cloud. Atomization of analytes start with the sample nebulization (spraying) process. 2

Sample atomization in the heat source aerosol for thorough mixing Larger drops aspiration The suction caused by high flow rates of oxidant gas - Venturi effect. Solution impinging on the bead aerosolizes the sample. Once formed, droplets in the nebulized spray are sent into a high-temperature environment such as a (chemical) flame or flowing rare-gas plasma - ICP. Nebulization serves to increase the surface area of the solution sample, so solvent evaporation (desolvation) can proceed more rapidly and so the resulting dried solute particles can be volatilized better. (flame atomic absorption, flame emission, and plasma emission spectrometry). In the flame; de-solvation and solute-particle vaporization takes place, the resulting vapor converted more or less efficiently into free atoms. M (g) e(g) M(g) 2 M (g) e(g) M (g).. The environment in the flames often hot enough that many of the atoms that are formed exist as positive ions. Also, the environment in these atomization sources is energetic to yield sufficient population in the exited state, strong emission from either the free atoms or their ionic counterparts. For each atomic/ionic species the population distribution can be calculated using the Boltzmann s Law, n u, n l excited and ground state populations, respectively: n n E u u RT l g e g l Statistical weighings n n E u u RT l g e g Large flame T makes power of the exponential term 0, despite high E; makes n u (excited state) significant making AES possible, from the radiative decay of the excited states. l 3

Flame AA implementation Flame AA block diagram AES I=kc analyte AAS AES Source In reality P 0 is the intensity of light reaching with the blank. AAS Lambert- Beer Law A=log(P 0 /P) =k c Atomic Spectral lines are sharp (narrow). AAS mode: The source is unique. The narrow band width of the spectral absorption/(emission) lines precludes the employment of broad band source-monochromator combination to irradiate the sample. The irradiating beam must be comparable or narrower bandwidth to that of the absorption profile. The strategy is to use the emission lines of high intensity from the element of interest. This is accomplished in HCLs. Hollow Cathode Lamp (HCL) V i At low pressure and applied high voltage a discharge is created. Discharge ionizes the inert atoms, ionized particles accelerated toward electrodes. High energy particles sputter atoms and ions into gas phase. made of the element of of analyte. discharge Ne or Ar at 1-5 torr Ions and atoms are exited by high energy particle impact. As they relax, they produce radiation of the same frequency of analyte of interest. 4

Spectral Line widths (absorption or emission) The AA line profile is broadened due to three factors: 1. Natural Decay leads to natural broadening 2. Doppler effect leads to Doppler broadening Where T is temperature and M is atomic mass. (Hz) (7.0 10 ) M 7 T 3. Pressure broadening due to collisions. Collisions lowers the excited state life time thus broadens the spectral line. The sample is at a higher temperature than the HCL. Therefore they will have two different profiles due to different broadening. Background in Atomic Spectroscopy is significant. Background signal should be accounted for in analysis. The significant background makes the usefulness of the pure absorbance value for calculations erroneous. The background arises due to; 1. scattering of the HCL light beam, mainly from the sample matrix; tends to reduce the power of the beam reaching the detector (false absorbance, P). 2. emissions from sample molecular species and from the fuel component emissions, generally broad spectral emissions; tends to increase the power reaching the detector (false P 0 ). Correction for the background emission is an essential feature in atomic spectroscopy. 5

Background correction methods: Beam chopping: Simple method to produce alternate current. Deuterium lamp: Use D 2 lamp to simulate the background intensity. Smith-Hieftje: Run HCL at high and low currents to produce different emission profiles of the lamp. First run lamp at low current measure absorbance of analyte and background. Then lamp is pulsed with a high current. During the pulse, the analyte absorbance is reduced but not to zero. Most of absorbance is due to background. Zeeman Background Correction: A magnetic field is used to split the degenerate energy levels. Under the field the species absorb polarized light only. This difference is exploited. Beam chopping Power reaching the detector No background Background P 0 P 0 A log kc P P Background + analyte D 2 Lamp correction D 2 Lamp Deuterium lamps generate a broad profile. Thus the absorbance from the D 2 lamp by analyte line is negligible. D 2 beam power loss is mainly due to background. aspirate solvent first; set zero aspirate sample; measure A D2 aspirate sample; measure A HCL A D2 =A background A HCL =A background + A analyte A HCL -A D2 =A analyte Measure the A for HCL and D 2 lamps, alternatively. Smith-Hieftje Background correction: Conceptually similar to D 2 correction (which uses a broad spectral band). Broad band is generated from the HCL itself..01nm 10nm A D2 for all practical purposes is due to background. A D2 =A background A HCL =A background + A analyte A HCL -A D2 =A analyte HCL at high currents produce a wide emission spectral line. Thus alternating the current density through the HCl (modulation), to account for the background (absorbance at high current density) and measure line absorbance and background ( absorbance at low current density) makes the correction possible A high =A background A lowl =A background +A analyte A low -A high =A analyte 6

Zeeman Background Correction - + Triplet B - + One peak three peaks Polarization w.r.t. B Interaction with polarized light: absorbs light if polarized parallel to the B. absorbs light if polarized normal to the B. When atoms are subjected to a B, the light component polarized parallel to B is absorbed by the atoms, but the light component polarized normal to B is hardly absorbed. The background contribution to absorption of light remains unchanged, however, from the any polarized light. Measuring the power of light parallel to B and normal to B measured at the same wave length the background absorption can be excluded; subtraction of signals of these two components the background component can be excluded. No absorption by component Zeeman Background Correction B Bkg abs B Bkg abs Un-polarized HCL line Un-polarized HCL line B Note: polarized radiation used. Absorption by component + bkg Variation A background + A analyte Variation A background + A analyte A background Polarization to B. A background Better in principle not in practice. Better in principle not in practice. 7

Graphite Furnace AA L vov platform Introducing a sample also introduces a matrix that will form a partially burnt ashy material. Such material blocks the light path and interfere with absorption measurements. To minimise such detrimental effects the temperature of The graphite tube increased starting at room temperature a in a stream of inert gas. 8

Oxidant-Fuel Combinations Oxidant Fuel Air Acetylene Nitrous oxide Acetylene Air Coal gas Air Propane Air Hydrogen Entrained air/ar Hydrogen Maximum Temp C 2250 2955 1825 1725 2045 1577 Interferences: Spectral interference: overlap of analyte signals from other elements. Select a different line to monitor. Oxygen Oxygen Oxygen Natural gas Hydrogen Cyanogen 2740 2677 4500 Fuel Background: Interference from partially oxidized fuel molecules Emission from N 2 O-C 2 H 2 flame Interference from the formation of molecular (refractory) species Chemical interference: Reduction of atomization because of the formation of non-volatile salts; in the presence of sulfates, phosphates. Use a complexing agent (protecting agent, EDTA, 8HQ) to protect the ion. Add La +3 (releasing agent) because LaPO 4 more stable, frees other atoms such as Ca 2+ nonvolatile salts. Use of fuel rich flame minimizes ionization, increase atom population. High temperatures make ion population significant however, increase ion population. 9

Ionization Interference: Often encountered with easily ionizable elements (alkali metals). Ionization very high, making atom population low. Effect of Ionization buffer on Atom population Reverse equilibrium by adding an ionization suppressor (buffer), e.g. CsCl (1000ppm). M(g) M (g) e(g) [M ][e] K [M] An ionization buffer is a salt of an alkali metal (easily ionizable). Ionization of alkali metals yields a higher electron density which would shift the ionization equilibrium of analyte M + to form atoms. Improving excited state species M + (g) M +* (g) M +* (g)+ h M 0 (g) Ionization interference is possible - ionization buffer for Potassium (1g/l high pure CsCl added to blank, standard and samples) association MY (g) + Releasing Agent M* (g) M + h Buffer against chemical interference with P, Al, Si for Calcium (10g/l high pure La 3+ added to blank, standard and samples ) or use of a N 2 O/C 2 H 2 flame (hotter). e.g. MY = CaSO4 or CaPO4. Internal Standards (IS) in Quantitative Analysis: An internal standard is a known amount of a compound, different from analyte, that is added to the unknown sample. Signal from analyte is compared with signal from the internal standard to find out how much analyte is present. This method is especially useful for analyses where the quantity of sample and/or the instrument response varies slightly from run to run for reasons beyond control. Because the concentration of internal standard known, the correct concentration of analyte can be determined. Internal standards are widely used in chromatography, spectroscopy because the small quantity of sample solution injected into the chromatograph is not very reproducible in experiments. In AA the flame instability creates situations of non-reproducibility. In cases where detector response vary with time form a good situation to use IS. Internal standards are also desirable when sample loss can occur during sample preparation steps prior to analysis. 10

For a known (concentration) mixture(s) of an internal standard and analyte the measured the relative response of the detector to the two species, F; If a known quantity of standard is added to the unknown prior to any manipulations, the signal ratio of standard to analyte remains constant because the same fraction of each is lost in any operation Analyte signal [X] F IS signal [S] A [X] F A [S] A [X] F b A [S] X S X S [X] and [S] are the concentrations of analyte and IS after they have been mixed together. Once F is established, use the same relationship above for where an the unknown and the IS are present to calculate the concentration of the unknown. 11