Light dark matter search with a spherical proportional counter

Similar documents
Background optimization for a new spherical gas detector for very light WIMP detection

IPRD 2016 IPRD Light Dark Matter searches at LSM, Modane and SNOLab. Ioannis KATSIOULAS CEA, Saclay / IRFU / SEDI.

Search for low-mass WIMPs with Spherical Detectors : NEWS-LSM and NEWS-SNO

Detecting low energy recoils with Micromegas

arxiv: v1 [astro-ph.im] 30 Jan 2014

A novel large-volume Spherical Detector with Proportional Amplification read-out

NEUTRINO OSCILLOMETRY- Neutrinos in a box

ANR NEWS (LDM) - R&D R2D2 (2b) (and the SPC)

Latest results of EDELWEISS II

arxiv: v1 [physics.ins-det] 4 Nov 2013

arxiv: v3 [physics.ins-det] 19 Sep 2017

University of Ioannina, Ioannina, Greece. AUTh, Thessaloniki, Greece

LUX-ZEPLIN (LZ) Status. Attila Dobi Lawrence Berkeley National Laboratory June 10, 2015 WIN Heidelberg

Search for Low Energy Events with CUORE-0 and CUORE

DarkSide new results and prospects

Direction-Sensitive Dark Matter Search --NEWAGE--

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

arxiv: v1 [astro-ph.im] 7 Nov 2011

Modane underground laboratory (Fréjus)

Extension of the LSM: report of the Scientific Advisory Committee Executive summary

Recent results from PandaX- II and status of PandaX-4T

arxiv: v1 [astro-ph.im] 6 Dec 2010

The EDELWEISS DM search Phase II to Phase III

Collaborazione DAMA & INR-Kiev. XCVIII Congresso SIF Napoli, 18 Settembre F. Cappella

Direkte Suche nach Dark Matter

Dark matter search by exclusive studies of X-rays following WIMPs nuclear interactions

Search for double electron capture on 124 Xe with the XMASS-I detector

DARWIN. Marc Schumann. U Freiburg PATRAS 2017 Thessaloniki, May 19,

A survey of recent dark matter direct detection results

SuperNEMO Double Beta Decay Experiment. A.S. Barabash, ITEP, Moscow (on behalf of the SuperNEMO Collaboration)

Direct dark matter search with XMASS. K. Abe for the XMASS collaboration

Direct Search for Dark Matter

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

Direct Detection of Dark Matter with LUX

Study of the HARPO TPC for a high angular resolution g-ray polarimeter in the MeV-GeV energy range. David Attié (CEA/Irfu)

The XENON1T experiment

Cryodetectors, CRESST and Background

XMASS: a large single-phase liquid-xenon detector

An ultra-low-background detector for axion searches

June 10 morning session 9:00-

Scintillator phase of the SNO+ experiment

The COHERENT Experiment: Overview and Update of Results

D. Medvedev GEMMA and vgen Nalchik, June 6, Investigation of neutrino properties with Ge detectors on KNPP

First Results from the CAST Experiment

Signatures in Directional Dark Matter Searches Asymmetries and the Diurnal Variation. J.D. Vergados University of Ioannina, Ioannina, Greece.

Vincenzo Caracciolo for the ADAMO collaboration National Laboratory of Gran Sasso - INFN.

Direction-Sensitive Dark Matter Search --NEWAGE--

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

Down-to-earth searches for cosmological dark matter

arxiv: v1 [physics.ins-det] 23 Oct 2007

arxiv:astro-ph/ v1 24 Jun 2004

Background and sensitivity predictions for XENON1T

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

Recent Progress on D 3 - The Directional Dark Matter Detector

Dark matter search with the SABRE experiment

Chung-Yao Chao Fellowship Interview

arxiv: v1 [physics.ins-det] 20 Dec 2017

Edelweiss-II : status and first results A new generation of background-free bolometers for WIMP search

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

LUX: A Large Underground Xenon detector. WIMP Search. Mani Tripathi, INPAC Meeting. Berkeley, May 5, 2007

COUPP: Bubble Chambers for Dark Matter Detection

SIGN: A Pressurized Noble Gas Approach to WIMP Detection

DARWIN. Marc Schumann. U Freiburg LAUNCH 17 Heidelberg, September 15,

Search for Sterile Neutrinos with the Borexino Detector

Neutron background in underground particle astrophysics experiments

Esperimenti bolometrici al Gran Sasso: CUORE e CRESST

THE NEXT EXPERIMENT FOR NEUTRINOLESS DOUBLE BETA DECAY SEARCHES ANDER SIMÓN ESTÉVEZ ON BEHALF OF THE NEXT COLLABORATION

Ultra-Low Background Counting and Assay Studies At SNOLAB

The CONNIE experiment

Oak Ridge National Laboratory, TN. K. Scholberg, Duke University On behalf of the COHERENT collaboration August 2, 2017 DPF 2017, Fermilab

COLUMNAR RECOMBINATION JIN LI INSTITUTE FOR BASIC SCIENCE CYGNUS2015 CONFERENCE JUN.3, 2015

DARWIN: dark matter WIMP search with noble liquids

Recent Results from the PandaX Experiment

PoS(idm2008)010. The PICASSO Dark Matter Search Project. A. Davour for the PICASSO collaboration Queen s University

Solar and atmospheric neutrinos as background for direct dark matter searches

A new detector for neutron beam monitoring

Detectors for the COHERENT neutrino experiment R. Tayloe Indiana U. for the COHERENT collaboration

Neutrino Masses and Mixing

R&D on Astroparticles Detectors. (Activity on CSN )

Gas Electron Multiplier detectors with high reliability and stability. Abstract. Introduction

Enectalí Figueroa-Feliciano

The XMASS Experiment. Jing LIU Kavli IPMU, Univ. of Tokyo PPC2013, Jul Deadwood, SD, USA

LARGE UNDERGROUND XENON

The GERmanium Detector Array

Coherent Neutrino-Nucleus Scattering Using the DAEdALUS Cyclotron(s) and a CLEAR-like Detector

DarkSide-50: performance and results from the first atmospheric argon run

Direct Search for Dark Matter

Low Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016

The Search for Dark Matter with the XENON Experiment

Direct dark matter search using liquid noble gases

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

Bubble Chambers for Direct Dark Matter Searches in COUPP

Status of the ANAIS experiment at Canfranc

The 46g BGO bolometer

Calibration of Single Phase Liquid Argon Detectors

Paolo Agnes Laboratoire APC, Université Paris 7 on behalf of the DarkSide Collaboration. Dark Matter 2016 UCLA 17th - 19th February 2016

Neutrino Experiments: Lecture 2 M. Shaevitz Columbia University

Neutron- and muoninduced. underground physics experiments. L. Pandola, V. Tomasello and V. Kudryavtsev. for the JRA1 and N3 simulation groups

Chapter 12. Dark Matter

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Transcription:

Light dark matter search with a spherical proportional counter I. Giomataris, CEA-Irfu-France NEWS (New Experiment for Wimps with Sphere) Main goal: search for ultra-light WIMP 100 MeV 10 GeV Using the novel spherical gaseous detector

NEWS is a more general network which could search for: Light dark, neutrino coherent scattering, low energy neutrino oscillations, Neutrinoless double beta decay, KK axions,... Thessaloniki 2012 Possible collaboration Cea/IRFU Saclay France Laboratoire Souterrain de Modane France University of Tessaloniki Greece University of Tsignhua China Institute of High Energy Physics China University of Jiao tong China NCSR Demokritos Greece University of Ioannina Greece Helenic Open university Greece University of Zaragoza Spain Livermore National Lab US University of Princeton US JINR Dubna Russia Cea/DRT France University of Georgia US CNRS/IN2P3/CPPM France

Low background detector d=60 cm p=10 bar University of Saragoza detector Spherical detector propagation Basic R@D detector in Saclay Future projects 2m detector will be developed At SNOLAB (G. Gerbier et al.) University of Thessaloniki detector University of Tsinghua - HEP detector

Radial TPC with spherical proportional counter read-out Saclay-Thessaloniki-Saragoza A Novel large-volume Spherical Detector with Proportional Amplification read-out, I. Giomataris et al., JINST 3:P09007,2008 5.9 kev 55 Fe signal E=A/R 2 20 µs 15 mm C R in = 7.5 mm < 1pF 03/07/14 I. Giomataris Simple and cheap Large volume single read-out Robustness Good energy resolution Low energy threshold Efficient fiducial cut

Micromegas Parallel Plate Detector GEM E= constant C S > 1nF Cylindrical Proportional Counter E=V/ln(b/a)r L = length and a=radius of the wire, b = tube radius C =2πL/ln(b/a)>> 10 pf Spherical Proportional Counter E=1/r 2 V/R i close to the ball C R in < 1pF 03/07/14 I. Giomataris

Electrostatics deal - how to maintain a radial field Ideal case: ball non wire 03/07/14 Ball with wire The Ball with umbrella corrector

Rejection power 03/07/14 I. Giomataris

New low-energy calibration source Argon-37 Home made Ar-37 source: irradiating Ca-40 powder with fast neutrons 7x10 6 neutrons/s Irradiation time 14 days. Ar-37 emits K(2.6 kev) and L(260 ev) X-rays (35 d decay time) Installation near the spherical detector First measurement with Ar-37 source Total rate 40 hz in 250 mbar gas, 8 mm ball 260 ev peak clearly seen A key result for light dark matter search Argon 37

Cuurent light DM: DAMA, COGENT, claim rejected? Light Dark Matter candidates < 10 GeV Light U boson(fayet, Boehm&Fayet) Secluded WIMP dark matter (Arkani-Hamed, Pospelov, Ritz, Voloshin) Kaluza-Klein Axion like Particle Assymetric Dark Matter Electron-Interacting dark matter SEARCH FOR LIGHTER MASSES

Search for light dark matter Detector installed at LSM end 2012 SEDINE detector made out of radiopure Cu Diameter = 60 cm, Pressure = up to 10 bar Gas targets: Ar, Ne, He, CH4 In situ Ar-37 calibration

Signing radon and Po-210 contamination with spherical detector apt on 3 He > p + T Rise time (µs) n capt on 3 He 764 kev α 210 Po 5.3 MeV α 210 Po 5.3 MeV from 210 Pb @ Cu surface R = 15 cm Po-210 from Cu surface Amplitude 222 Rn 218 Po 214 Po RMS =.5% 222 Rn Excellent energy resolution with radon gas 218 Po Thermal neutron peak after rise time cut Results at LSM Thermal neutron flux 2.2x10-6 /cm 2 /s 214 Po

Po-210, Pb-210 contamination deal 1st prototype 1st prototype: after cleaning the internal spherical vessel by spraying nitric acid we observed a decrease of alpha rate (at 5.3 MeV) with a decay time of Po-210 Low background detector: 1st cleaning: after filling the internal spherical vessel (last year) with nitric acid we observed a decrease of alpha rate of about 3 but then a stable rate (.06Hz) (Pb-210 not removed?) 2nd cleaning: Cu vessel was sprayed with nitric acid Similar to the 1st prototype procedure the rate drops to (.004Hz) 3rd cleaning: the rate drops to (.002Hz) Significant drop LSM detector

Light WIMP search results Ne at 500 mbar Ne at 500 mbar Rise time (µs) Excess? Hardware threshold 50 ev Effective threshold 100 ev 3.5 evts/kev/d Amplitude Energy (ev) 100 ev Projected sensitivity 1 ev 10 ev H 2 target vs threshold

Projected sensitivity with a 2 m detector Simulations by Kaxuan Ni et al.,

Quenching factor measurements Goal: measure QF down to 500 ev ion energy using the Grenoble MIMAC facility for H, He, Ne, CF4, Ar, Xe at various pressures Earlier measurements D. Santos et al., arxiv:0810.1137 He-4 700 mbar Recent investigations with a 15 cm sphere show the capability to measure 500 ev He-4 ions with an estimated QF of about 30% Saclay, Grenoble, Thessaloniki, Queen s-kingston

Additional Physics Motivated by: Sub-keV energy threshold of the detector Large volume detector (1 m 3 to much larger) Large mass and sub-kev energy threshold Good energy resolution Low background Versatility of the target (gas and pressure) Neutrino-nucleus coherent elastic scattering near a nuclear reactor A dedicated Supernova detector (4 m in diameter) Y. Giomataris, J. D. Vergados, Phys.Lett.B634:23-29,2006 Idea : A world wide network, at University level, of several (tenths or hundreds) of such dedicated Supernova detectors managed by students Gravitationally trapped massive Axion (like) particles decays L. Di Lella, K. Zioutas, Astropart. Phys. 19 (2003) 145 Room size Neutrino oscillations using very low energy neutrino sources I. Giomataris, J.D. Vergados, Nucl.Instrum.Meth.A530:330-358,2004, J.D. Vergados,Y. Giomataris, Y. Novikov, Nucl.Phys. B854 (2012) 54-66, Phys.Rev. D85 (2012) 033003 Background free double beta decay experiment, I. Giomataris, arxiv:1012.4289

KK-axions as a candidate to low energy decay Zero background estimation SEDINE sensitivity Ratio 2-prong to 1-prong events coming from a decay signal Furthermore flexibility on gas mixture and pressure allows to proof the decay hypothesis by modulating the 2-prong and 1-prong efficiency J.Galan, Patras 2013 http://arxiv.org/abs/1310.4092 Slides

Low energy decay detection capability SPC advantages Low energy threshold Large volume Low volumetric background levels Measured event in Argon Simulated time signals at different pressures Event close to sensor Event near surface Detection of 2-prong events depends on pressure Higher pressure Efficiency to 2-prong events depends on diffusion and attenuation lenght Argon Neon

CONCLUSIONS A new promising counter on spherical geometry Ultra low energy threshold capability down to single electron Light dark matter search down to 100 MeV Excess below 400 ev in Neon is under study 03/07/14 I. Giomataris