Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant

Similar documents
CHEMICALS & REAGENTS

Thermo Scientific Orion Solutions, Standards and Buffers. The high-quality solutions you need for electrochemistry measurement

User Manual. Thermo Scientific Orion Fluoride Ion Selective Electrode

Ion Selective Electrodes for the Laboratory. Presented by Chris Cushman OTCO Water Laboratory Analyst Workshop Thursday, May 14, 2015

Thermo Scientific Orion Star T900 Series Laboratory Titrators. Potentiometric titrators for performing automated ph, redox, or ion titrations

User Guide. Iodide Ion Selective Electrode

Method Abstract. Flow Solution Fluoride, USGS by ISE and FIA

User Guide. Bromide Ion Selective Electrode

User Guide. Calcium Ion Selective Electrode

User Guide. High Performance Ammonia Ion Selective Electrode

Direct Measurement ISE Method Method to 4.00 mg/l NO 3 N TISAB Solution

COLE-PARMER INDUSTRIAL AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

User Guide. Cyanide Ion Selective Electrode

Applications of Ion-Selective Electrodes

Fluoride Sealed Electrode Sensor Bundle Product Number: ENFLU049

METHOD 9210 POTENTIOMETRIC DETERMINATION OF NITRATE IN AQUEOUS SAMPLES WITH ION-SELECTIVE ELECTRODE

F- Cl- Br- I- CN- S2- NO3-

Ion Selective Electrode Probe

Ion Selective Electrodes

ph Probe Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth 1 99 C

User Guide. Cupric Ion Selective Electrode

ph Probe Spear Tip Silver / silver chloride Reads Range / Resolution 95% in 1s Response time 100 PSI Max pressure 60m (197 ft) Max depth

ION SELECTIVE MEASUREMENT

User Guide. ROSS Sodium Ion Selective Electrode

Measuring Ammonia in Water and Wastewater using the Thermo Scientific Orion Dual Star ph/ise Meter

User Guide. Perchlorate Ion Selective Electrode

Ammonia Gas Sensing Combination Electrode

perfection Guidebook perfection Combination Fluoride Electrode Successful Ion Measurement

User Guide. Cadmium Ion Selective Electrode

Sodium Sealed Electrode Sensor Bundle Product Number: ENSOD051

Ammonia Gas Sensing Combination Electrode

COLE-PARMER LABORATORY NITRATE ION ELECTRODE INSTRUCTION MANUAL

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

Measurements with Ion Selective Electrodes: Determination of Fluoride in Toothpaste

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

COLE-PARMER INDUSTRIAL POTASSIUM ION ELECTRODE INSTRUCTION MANUAL

Chloride, HR, Direct Measurement ISE Method Method g/l to 35 g/l Cl Powder Pillow ISA

User Guide. High Performance Ammonia Ion Selective Electrode

User Guide. Lead Ion Selective Electrode

COLE-PARMER LABORATORY CALCIUM ION ELECTRODE INSTRUCTION MANUAL

Operating Instructions for Ammonium ISE Specifications

COLE-PARMER INDUSTRIAL NITRATE ION ELECTRODE INSTRUCTION MANUAL

NO 500 DIN, NO 500 BNC NO 800 DIN, NO 800 BNC

COLE-PARMER LABORATORY AMMONIUM ION ELECTRODE INSTRUCTION MANUAL

All about ph! Is it as simple as it seems? The ph Workshop. Rick Noone Thermo Scientific Water Analysis Instruments, Orion products May 22, 2014

The Cole-Parmer Nitrate Ion Electrodes are used to quickly, simply, accurately, and economically measure nitrate in aqueous solutions.

Ammonium Sealed Electrode Sensor Bundle Product Number: ENAMN020A

COLE-PARMER LABORATORY CUPRIC ION ELECTRODE INSTRUCTION MANUAL

User Guide. Green ph Electrodes

How Electrode Design Correlates with Optimum Performance in ph Measurement

Authorized Distributor Clarkson Laboratory & Supply Inc. Phone Fax

What is a WQSensor? Software Installation. Uninstalling WQSensors Software. NexSens Technology, Inc. TABLE OF CONTENTS

The Cole-Parmer Ammonium Ion Electrode is used to quickly, simply, accurately, and economically measure ammonium ions in aqueous solutions.

Guide to ph Analysis.

GENERAL INSTRUCTIONS GENERAL PREPARATION

COLE-PARMER REPLACEABLE MEMBRANE CALCIUM ION ELECTRODES INSTRUCTION MANUAL

Chem 321 Lecture 17 - Potentiometry 10/24/13

perfection Guidebook perfection Combination Iodide Electrode Successful Ion Measurement

NO 2. Orion Nitrite Electrode INSTRUCTION MANUAL. Orion 93-46, Orion 97-46, ionplus. Analyze Detect Measure Control

perfection Guidebook perfection Combination Cupric Electrode Successful Ion Measurement

GENERAL INSTRUCTIONS GENERAL PREPARATION

User Guide. Fluoroborate Ion Selective Electrode

Advanced Sensor Technologies, Inc. TEL: TOLL FREE: WOW-ASTI ( ) FAX:

phoenix Electrode Company CARBON DIOXIDE GAS-SENSING ELECTRODE INSTRUCTION MANUAL 1. A ph/mv meter or an ion meter, either line operated or portable.

Ion Selective Electrodes

C = concentration as ppm sulfide V t = volume of titrant at endpoint V s = volume of standard used (10 ml)

Determination of fluorides in aqueous samples using membrane, ion selective electrode (ISE)

COLE-PARMER INDUSTRIAL CALCIUM ION ELECTRODE INSTRUCTION MANUAL

ISO-TECH SYSTEM, VARANASI Analysis by ph and ion selective electrodes

NH 3 -selective electrodes

perfection Guidebook perfection Combination Cyanide Electrode Successful Ion Measurement

Turn your Ion Analyzer into a Titrator

ph Calibration Buffers

Cl - Orion Chloride Electrode INSTRUCTION MANUAL. Orion Orion ionplus. Analyze Detect Measure Control

WEEK 2 EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

Concise laboratory catalogue

POTASSIUM ION SELECTIVE ELECTRODE

ORP Probe. Mini ORP. Reads. +/-2000mV. Range SMA. Connector. 95% in 1s. Response time 100 PSI. Max pressure. 60m (197 ft) Max depth 1 80 C

PRACTICAL 3 ph AND BUFFERS

Nanotechnology Sensors

Cadmium Reduction Method (Using Powder Pillows or AccuVac Ampuls)

NITRITE, Low Range (0 to mg/l NO 2- -N)

1) A ph/mv meter or an ion meter, either line operated or portable.

Benchtop Water Quality Meters 1000 Series

DR/4000 PROCEDURE. HARDNESS, Total

The Oakton Cadmium Ion Electrodes are used to quickly, simply, accurately, and economically measure cadmium ions in aqueous solutions.

EXP. 9 EVALUATION OF METHODS FOR DETECTING AMMONIUM: ION SELECTIVE ELECTRODES AND SPECTROSCOPY

phoenix Electrode Company Ammonia Gas-Sensing Electrode Instruction Manual

Use a pipet bulb when pipeting cyanide solutions, as these solutions are highly toxic.

DR/4000 PROCEDURE NITRATE. Using Powder Pillows

Determination of fluoride with an ion-selective electrode

Potentiometry: Ion-Selective Electrodes

NH4 Model 9318 AMMONIUM ELECTRODE INSTRUCTION MANUAL. A Thermo Electron business

GENERAL INSTRUCTIONS GENERAL PREPARATION

1225 Lab # 11 Fluoride Speciation and Analysis by Flow Injection using Ion-Selective Electrode: Measurement of Total Fluoride in Water

Write the ionic equation for this neutralisation reaction. Include state symbols.

COLE-PARMER LABORATORY CYANIDE ION ELECTRODE INSTRUCTION MANUAL

User Guide. Carbon Dioxide Ion Selective Electrode

S ENTEK Unit 6 & 7 Crittall Court, Crittall Drive, Springwood Industrial Estate, Braintree, Essex, CM7 2SE Tel: +44 (0) Fax: +44 (0)

phoenix Electrode Company Silver/Sulfide Ion Electrodes Instruction Manual 1. A ph/mv meter or an ion meter, either line operated or portable.

Transcription:

Thermo Scientific Orion Fluoride Ion Selective Electrodes The standard in fluoride ion analysis EPA compliant Approved ASTM Method for Fluoride in Drinking Water and Wastewater Analyze free fluoride ions in aqueous solutions reliably at low limits of detection. Thermo Scientific Orion fluoride electrodes feature high quality lanthanum fluoride pellet sensors. Choose from electrodes or half cell designs. The fluoride half cell electrode requires a separate half cell electrode. Fluoride Electrodes Phosphate: Gran plot titration can determine phosphate in applications from animal feed to cleaning solutions to food and beverage Ammonium Bifluoride: Multiple known addition (MKA) titration method determines levels without need of removing interfering heavy metal ions Aluminum: Gran plot titration can determine micro and semi micro levels of aluminum offered to meet your measurement needs. A variety of calibration standards are available. Low level standards have the added convenience of being pre-made with total ionic strength adjustor (TISAB) and requiring that TISAB be added only to your samples. TISAB II requires a 50:50 dilution with the sample and is available in gallon bottles. TISAB III is a concentrate and requires a 1:10 dilution. with Combination fluoride ISE Fluoride surface can be easily cleaned using toothpaste and a lint-free wipe Built-in Sure-Flow provides fast and Cat. No. 9609BNWP 9409BN 9409SC 900100 Temp. Range 0 to 80 C 0 to 80 C 0 to 100 C Connector Type Half cell design Half cells Fluoride ISE and Sure-Flow BNC Screw Cap Pin Tip Fluoride surface can be easily cleaned using toothpaste and a lint-free wipe Use with the 900100 single junction or 900200 double junction electrodes 940906 0.1 M NaF standard, 475 ml 940907 100 ppm fluoride standard, 475 ml 040906 1 ppm fluoride standard with TISAB II, 475 ml 040907 2 ppm fluoride standard with TISAB II, 475 ml 040908 10 ppm fluoride standard with TISAB II, 475 ml 940909 TISAB II, 1 gallon 940999 TISAB II, 4 x 1 gallon 940911 TISAB III concentrate, 475 ml 900061 Optimum results A electrode fill solution for 9609BNWP, 5 x 60 ml 900001 Fill solution for 900100 used with 9409BN/9409SC, 5 x 60 ml BNC Screw Cap Pin Tip 92 Sourcebook Thermo Scientific Orion Laboratory Products Catalog

Thermo Scientific Orion Ammonia Ion Selective Electrodes EPA Approved ASTM D1426 Method for Ammonia in Wastewater Thermo Scientific Orion ammonia electrodes feature time-tested membrane technology. Choose from high and standard designs. The high ammonia electrode offers linear response down to the lower limits of detection. The electrode can detect down to 0.01 ppm. The high ammonia electrode can achieve response times of 1 minute in samples of 1 ppm or higher. It is rugged and meets the rigorous requirements of waste water and drinking water operators. Supplied with pack of 20 loose membranes, 1 pre-assembled outer body and 2 bottles of fill solution. Ammonia Electrodes Ammonium or Nitrogen: Measure ammonium after conversion to ammonia or nitrogen after Kjeldahl digestion of sample offered to meet your measurement needs. High ammonia electrode Pre-assembled body and membrane simplifies use and achieves optimum Standard ammonia electrode Provides reliable results at mid to high ammonia levels BETTER Ion Selective Electrodes Cat. No. 9512HPBNWP 5 x 10-7 to 1.0 M 0.01 to 17,000 ppm 9512BNWP 5 x 10-7 to 1.0 M 0.01 to 17,000 ppm Temp. Range 0 to 50 C 0 to 50 C Connector Type HP Electrode 951214 Loose membranes for HP electrodes, box of 20 Pre-assembled outer body and 951215 membrane cap assembly for HP electrodes, 3 pack 951210 with no metallic ions, 475 ml 951211 containing metallic ions, 475 ml 951213 Ammonia electrode storage solution, 475 ml 951209 HP ammonia electrode filling solution, 60 ml 951006 0.1 M NH4Cl standard, 475 ml 951007 1000 ppm ammonia as nitrogen standard, 475 ml Standard Electrode 951204 Loose membranes for standard electrodes, box of 20 951205 Bonded membranes for standard electrodes, pack of 3 951210 with no metallic ions, 475 ml 951211 containing metallic ions, 475 ml 951213 Ammonia electrode storage solution, 475 ml 951202 Standard ammonia electrode filling solution, 60 ml 951006 0.1 M NH4Cl standard, 475 ml 951007 1000 ppm ammonia as nitrogen standard, 475 ml Thermo Scientific Orion Laboratory Products Catalog Sourcebook 93

Thermo Scientific Orion Nitrate Ion Selective Electrodes The Easy Way to Measure Nitrate Levels in Drinking Water, Wastewater and Soils Analyze free nitrate ions in aqueous solutions reliably at low limits of detection. Choose from electrodes or half cell designs. The nitrate half cell electrode requires a separate half cell electrode. Nitrate Electrodes Nitric Acid: Multiple known addition (MKA) titration method determines levels without need of removing interfering heavy metal ions. offered to meet your measurement needs. A variety of calibration standards are available. Replacement modules are available individually or in convenient three packs. electrode with replaceable module Combination nitrate ISE with Sure- Flow Sure-Flow provides and is easy to clean with small sample sizes Half cell design Half cells Nitrate ISE and Sure-Flow Reference junction is reliable and easy to maintain Replaceable module provides convenience Cat. No. 9707BNWP 9307BNWP 900200 7 x 10-6 to 1.0 M 0.1 to 14,000 ppm as N 7 x 10-6 to 1.0 M 0.1 to 14,000 ppm as N Temp. Range 0 to 40 C 0 to 40 C 0 to 100 C Connector Type Pin Tip 900046 Optimum results F electrode fill solution, 5 x 60 ml. For 9707BNWP and outer fill solution for 900200 900002 Inner chamber fill solution for 900200, 5 x 60 ml 920706 0.1 M NaNO3 standard solution, 475 ml 920707 1000 ppm nitrate as nitrogen standard, 475 ml 930707 100 ppm nitrate as nitrogen standard, 475 ml 930711 Nitrate ionic strength adjustor (ISA), 475 ml 930710 Nitrate interference suppressor solution (NISS), 475 ml 970701 Replacement module for 9707BNWP (1 each) 930701 Replacement module for 9307BNWP (pack of 3) 930702 Replacement module for 9307BNWP (1 each) Pin Tip 94 Sourcebook Thermo Scientific Orion Laboratory Products Catalog

Thermo Scientific Orion Chloride Ion Selective Electrodes Approved ASTM Method for Chloride in Wastewater Easily and reliably analyze free chloride ions in aqueous solutions. Provides quick, accurate and economical measurements. Rugged epoxy body design ensures durability of electrode. Chloride Electrodes Salt: Multiple known addition can be used to determine salt levels in food samples Hydrochloric Acid: First derivative titration can determine HCl concentrations Thermo Scientific offers a full line of accessories to enhance your measurements. These include calibration standards, two ionic strength adjustors one to adjust background ionic strength (ISA) and another to minimize complexation interferences and adjust background ionic strength (CISA), and choice of fill solutions depending on sample composition. Combination chloride ISE Durable pellet which can be polished to restore electrode Sure-Flow provides easy maintenance and optimum Cat. No. 9617BNWP 5 x 10-5 to 1.0 M 1.8 to 35,000 ppm Half cell design Half cells - Chloride ISE and double junction Sure-Flow Double junction isolates inner from sample Designed for precision measurements 9417BN 9417SC 900200 5 x 10-5 to 1.0 M 1.8 to 35,000 ppm Temp. Range 0 to 80 C 0 to 80 C 0 to 100 C Connector Type BNC Screw cap Pin Tip Ion Selective Electrodes 940011 Chloride ionic strength adjustor (ISA), 475 ml 941709 Chloride CISA reagent pack, 2 x 2 L 941706 0.1 M NaCl standard, 475 ml 941708 1000 ppm chloride standard, 475 ml 941707 100 ppm chloride standard, 475 ml 900062 Optimum results B fill solution for 9617BNWP, 5 x 60 ml 900017 Chloride electrode fill solution, 5 x 60 ml, for samples more concentrated than 10-2 M 900003 Outer chamber fill solution for 900200, 5 x 60 ml 900002 Inner chamber fill solution for 900200, 5 x 60 ml 948201 Polishing strips, pack of 24 BNC Screw Cap Pin Tip Thermo Scientific Orion Laboratory Products Catalog Sourcebook 95

Thermo Scientific Orion ROSS Sodium Ion Selective Electrodes ROSS Fast Response and Stability Comes with Complete Solution Kit Containing Standards, Reagents, ISA and More! Quick, accurate and economical measurements of free sodium ions in aqueous solutions. Chemical resistant glass body. Applications for Sodium Electrodes The sodium electrode is commonly used to measure samples such as food, beverages and animal feed. Thermo Scientific provides you all the accessories you need for sodium measurement when you purchase a ROSS sodium electrode. Each electrode comes with electrode fill solution, sodium ionic strength adjustor, 3 different sodium standards, sodium electrode reconditioning solution and sodium electrode storage solution. Combination Ross Sodium ISE with Sure-Flow Half cell design with choice of ROSS s Half cells - Chloride ISE and double junction Sure-Flow and optimum Unique redox ROSS system provides fast response, better stability and accuracy than conventional sodium electrodes Sure-Flow prevents clogging while giving fast, Cat. No. 8611BNWP Choice of ROSS systems: ROSS Sure-Flow (800300) with easy to clean and reliable junction ROSS Ultra (800500U) with ROSS and extended life with 2 year warranty 8411BN 800300 800500U Temp. Range 0 to 100 C 0 to 100 C 0 to 100 C Connector Type BNC Pin Tip 941706 0.1 M NaCl standard, 475 ml 841108 1000 ppm sodium standard, 475 ml 941107 100 ppm sodium standard, 475 ml 941105 10 ppm sodium standard, 475 ml 650700 Known addition kit 3 x 475 ml of 1 M NaCl standard with ISA and 1 x 475 ml ISA 841109 Know addition standard, 1000 ppm as Na + with ISA, 475 ml 841111 Sodium ionic strength adjustor (ISA), 475 ml 841113 Sodium electrode reconditioning solution, 475 ml 841101 Sodium electrode storage solution, 475 ml 900010 Sodium electrode fill solution, 5 x 60 ml 900012 Sodium electrode fill solution for low sodium levels (below 10-5 M or 0.2 ppm) BNC Pin Tip 96 Sourcebook Thermo Scientific Orion Laboratory Products Catalog