Extraction Process Validation of Isatis Radix

Similar documents
Journal of Chemical and Pharmaceutical Research, 2015, 7(4): Research Article

Research of Quality Standards for Stachydrine Hydrochloride in Chinese Medicine TJF Granule

Rapid quantification of Chinese medicine Zuo Jin Pill using rapid resolution liquid chromatography

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Journal of Pharmaceutical and Biomedical Analysis Letters. Analysis Letters

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

Chapter 4: Verification of compendial methods

Comprehensive 2D-LC Analysis of Chinese Herbal Medicine

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

NEVIRAPINE ORAL SUSPENSION Final text for addition to The International Pharmacopoeia (February 2009)

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD TO DETERMINE CINITAPRIDE HYDROGEN TARTARATE IN BULK AND PHARMACEUTICAL FORMULATION

Modernizing the USP Monograph for Acetaminophen

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Pharmacophore 2011, Vol. 2 (4), ISSN Pharmacophore. (An International Research Journal)

CIPAC. CIPAC Free relevant impurities methods:

CYCLOSERINE Final text for addition to The International Pharmacopoeia. (November 2008) CYCLOSERINUM CYCLOSERINE

J Pharm Sci Bioscientific Res (4): ISSN NO

Impact factor: 3.958/ICV: 4.10 ISSN:

INTERNATIONAL JOURNAL OF UNIVERSAL PHARMACY AND BIO SCIENCES

EFAVIRENZ Final text for addition to The International Pharmacopoeia

Reverse Phase High Performance Liquid Chromatography method for determination of Lercanidipine hydrochloride in bulk and tablet dosage form

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

7. Stability indicating analytical method development and validation of Ramipril and Amlodipine in capsule dosage form by HPLC.

HPLC Method Development and Validation for the estimation of Esomeprazole in Bulk and Pharmaceutical Dosage Form

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

Development and Validation of Stability-Indicating RP-HPLC Method for Estimation of Atovaquone

Development And Validation Of Rp-Hplc Method For Determination Of Velpatasvir In Bulk

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Stability Indicating RP-HPLC Method for Determination of Valsartan in Pure and Pharmaceutical Formulation

International Journal of Pharmacy and Pharmaceutical Sciences Vol 2, Issue 1, 2010

Analysis of Saponins in Spine Date Seed using Agilent ZORBAX Solvent Saver HT (1.8 µm) Columns

Method Development and Validation Of Prasugrel Tablets By RP- HPLC

Fast methods for the determination of ibuprofen in drug products

High-Throughput LC-MS/MS Quantification of Estrone (E1) and Estradiol (E2) in Human Blood Plasma/Serum for Clinical Research Purposes

*Author for Correspondence

Analytical method development and validation of gabapentin in bulk and tablet dosage form by using UV spectroscopic method

ARTEMETHER AND LUMEFANTRINE TABLETS: Final text for addition to The International Pharmacopoeia (July 2008)

Development and validation a RP-HPLC method: Application for the quantitative determination of quetiapine fumarate from marketed bulk tablets

A RP-HPLC METHOD DEVELOPMENT AND VALIDATION OF PARA- PHENYLENEDIAMINE IN PURE FORM AND IN MARKETED PRODUCTS

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

LUMEFANTRINUM LUMEFANTRINE

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

Volume 6, Issue 2, January February 2011; Article-015

Research Journal of Pharmaceutical, Biological and Chemical Sciences

Appendix II- Bioanalytical Method Development and Validation

with diode array detection

Pelagia Research Library

Simultaneous HPLC Determination of Methocarbamol, Paracetamol and Diclofenac Sodium

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

Analytical Method Development and Validation of Lafutidine in Tablet dosage form by RP-HPLC

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

International Journal of Research in Pharmaceutical and Nano Sciences Journal homepage:

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Peptide Isolation Using the Prep 150 LC System

Unexpected Peaks in Chromatograms - Are They Related Compounds, System Peaks or Contaminations? From the Diary of an HPLC Detective

KEYWORDS: Acetaminophen, Doxylamine succinate, Dextromethorphan hydrobromide.

637. Thiamethoxam. HPLC method

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

H 3 CO H 3 CO S CH 3

Sulfotepp impurities in Chlorpyrifos EC formulations

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

Development and validation of RP- HPLC method for determination of ticagrelor in pharmaceutical dosage formulation

The Application of Lab Environment as the External Disturbance in the 3-Stage IR Method for the Facile Discrimination of Danggui Formula Granules

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

STABILITY INDICATING METHOD OF RELATED IMPURITIES IN VENLAFAXINE HYDROCHLORIDE SUSTAINED RELEASE TABLETS

Chromatography & instrumentation in Organic Chemistry

Qualitative and Quantitative Characterization of Monosaccharide Components of

Low-level Determination of 4-Hydrazino Benzoic Acid in Drug Substance by High Performance Liquid Chromatography/Mass Spectrometry

Int. J. Pharm. Sci. Rev. Res., 30(2), January February 2015; Article No. 09, Pages: 63-68

Supporting Information

INTERNATIONAL JOURNAL OF RESEARCH IN PHARMACY AND LIFE SCIENCES

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Journal of Chemical and Pharmaceutical Research, 2017, 9(1): Research Article

Development of Validated Analytical Method of Mefenamic Acid in an Emulgel (Topical Formulation)

Determination of Caffeine by HPLC

Determination of Verapamil Hydrochloride Purity Using the Acclaim PA Column

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

CHAPTER INTRODUCTION OF DOSAGE FORM AND LITERATURE REVIEW

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF THE

Certificate of Analysis

Egualen Sodium Granules

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Method Development and Validation for the Estimation of Darunavir in Rat Plasma by RP-HPLC

RP-HPLC Method Development and Validation of Dapagliflozin in Bulk and Tablet formulation

LC Determination of Deferasirox in Pharmaceutical Formulation

Supercritical CO 2 extraction of Codonopsis

Relative Response Factor for Lamivudine and Zidovudine Related substances by RP-HPLC with DAD detection

Pelagia Research Library

RESOLUTION OENO 33/2004 DETERMINATION OF SHIKIMIC ACID IN WINE BY HPLC AND UV-DETECTION

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

Transcription:

Pharmacology & Pharmacy,,, - Published Online April in SciRes. http://www.scirp.org/journal/pp http://dx.doi.org/./pp.. Extraction Process Validation of Isatis Radix Junshan Li, Bo Zhang Shineway Pharmaceutical Group Ltd., Shijiazhuang, China Email: swljs@sina.com Received January ; revised March ; accepted March Copyright by authors and Scientific Research Publishing Inc. This work is licensed under the Creative Commons Attribution International License (CC BY). http://creativecommons.org/licenses/by/./ Abstract This study is aimed to validate the extraction process of Isatis Radix. Using near infrared spectroscopy and high performance liquid chromatography to determine the uridine, adenosine, guanosine contents in Isatis Radix Solution, as well as NIR to monitor the extraction process. The results indicate that the existing extraction is optimized to extract thoroughly. Keywords Isatis Radix; Extraction Process; NIR Spectroscopy; HPLC; Validation. Introduction Isatis Radix is the dried root of cruciferous plant Isatis indigotica Fort. It is traditionally used to clear away heat & detoxify, cool the blood and benefit the throat []. And it is a medicine for epidemic prevention and slight cold. The traditional extraction process is decocting the Isatis Radix ingredients with - times of water two times, and each time is about half an hour. The modern extraction process is the first extraction that added times of water, and kept temperature at C - C for hour; and the second extraction added times of water, and kept temperature at C - C for. hour. As the Isatis Radix alkaloids (uridine, adenosine, Guanosine, etc.) having significant antiviral activity [], this study uses near infrared spectroscopy and high performance liquid chromatography technology to detect uridine, adenosine and guanosine in Isatis Radix extraction solution, and to verify the modern industrial production of Isatis Radix.. Methods.. Equipments and Materials Model multifunction extracting tank (Wuhan Pharmaceutical Machinery Factory); near infrared spectrometer (Focused Photonics Inc.); Diane U-HPLC (with diode array detector and chameleon chromatography workstation); Column: Phenomenexluna RP C,. mm, μm. How to cite this paper: Li, J.S. and Zhang, B. () Extraction Process Validation of Isatis Radix. Pharmacology & Pharmacy,, -. http://dx.doi.org/./pp..

Isatis Radix is accredited by Chinese Medicine Expert Sun Baohui to be the dried roots of cruciferous plant Isatis indigotica (Batch number:,,,,,,,,,,,,,,,,,,, ). Uridine (Batch number: - ) and Adenosine (Batch number: - ). Reference Substances are purchased from National Institutes for Food and Drug Control. Guanosine (CAS NO: --). Reference Substances are purchased from Simga Co. Acetonitrile is chromatographic pure, while water is purified water and the other reagents are analytical pure... Production of Isatis Radix Extraction Wash the Isatis Radix, cut kg into pieces, and put them into multi-functional tank. Add water with times of Isatis Radix for the first extraction, and keep temperature at C for hour. Add water with times of Isatis Radix for the second extraction, and keep temperature at C for. hour. Mix the two times extraction to be the extraction solution... Sample Take samples in the circulation pipeline at the side of extraction tank during producing. Samples flow through NIR channel and then loop back to the extraction tank. NIR channel is always flowing with extraction solution from the starting to the ending. NIR carry out a full scan analysis every two minutes. Take the first nine batches samples out to be the extraction reference solution and analyze them... Spectrum Condition NIR scanning mode: optic fiber transmission scan at spectral range - nm, and resolution is nm. Use the air as the blank, and scan times with double benefit (Figure )... Chromatographic Conditions... Chromatographic System Suitability Test Use the.% formic acid solution as mobile phase A, and acetonitrile as mobile phase B. Gradient elute according to Table gradient (gradient elution); flow rate is. ml/min, and column temperature is C; detection wavelength is nm. Inject μl test solution accurately to HPLC, determine, and record minutes chromatography then quantified by using external standard method.... Preparation of the Reference Solution Accurately weigh uridine, adenosine, Guridine Reference Substances to the same flask and prepare the solution at. mg/ml each of the three components (Figures and ).... Methodology Validation Take the extraction solution made from batch Radix extract to test the precision, linear, repeatability and recovery of above chromatographic conditions. All are in good results as indicated in Table.... Sample Detection Use the above chromatographic conditions to detect the batches of extract solution. The content of Uridine, Adenosine and Guridine are calculated by external standard method, and the content scope is in Table. Use Table. Gradient elution spectrum conditions of Isatis Radix. Time (min) B (%) A (%) - - - -

Table. Chromatographic conditions methodology validation study. Components Precision/% Linear Equation Correlation Coefficients Repeatability/% Recovery Result/% Recovery RSD/% Uridine. y =.x +..... Adenosine. y =.x +..... Guridine. y =.x +..... Table. Isatis radix contrast model parameters. Ingr. Extr. Time Content µg/ml Spectra Treatment Spectrum Scope Main Factors Correlation Coefficient Calibrated Std Dev RMSEP Rridine Adenosine Guanosine st extr. - Original - nm... nd extr. - Original - nm... st extr. - Original - nm... nd extr. - Original - nm... st extr. - Original - nm... nd extr. - Original - nm... Figure. NIR spectrum of isatis radix. the extraction time as abscissa and the content of each component as a vertical coordinate. Each of contents showed the map as Figures -. Comparison the content changing trends of batches of sample extraction. The variation trends are similar... NIR Prediction Model Select spectrums of each batch from first extractions in total batch (take for first batch) while spectrums from second extractions of each batch (take for first and second batches). Establish Content Prediction Model of each extraction in line with the corresponding NIR and predict the contents of above mentioned components. Parameters of sub-models to each component are shown in Table. Predict the contents of re-

mau WVL: nm - min............. Figure. Spectrum of mixed RS of Isatis Radix. mau WVL: nm - min............. Figure. Spectrum of Isatis Radix sample. Figure. Figure of uridine trend by HPLC.

Figure. Figure of adenosine trend by HPLC. Figure. Figure of guanosine trend by HPLC. maining samples except the ones used for model establishment in nine batches; compare the contents with the results obtained by HPLC. And relative deviations of the results vary from.% to.% which mean good correlation (Figure )... Results and Analysis See Figure to find the NIR prediction trend of each component of contents on Batch Isatis Radix. In first extraction, all component s gradually increase and reach equilibrium at around minutes. In second extraction, the trend of each active component show solwly increase and reach equilibrium at around minutes, and then trends of the content exponential of all components are gradually lower & slow. Contents of each component in batches of Isatis Radix extraction solution have tiny deviation at the same time interval, as well as a similar exponential trend line which are gradually lowered and slowed in Figures -.. Discussion ) Different batches of Isatis Radix extraction solution under the current production procedures share a similar content as well as the variation trend which means that the extraction method is stable. In the industrial production, the first extraction takes longer time than the second extraction on reaching equilibrium due to the huge input quantities, slow heating and other factors reaching equilibrium. In the first extraction, it takes minutes for uri-

and NIR Data J. S. Li, B. Zhang NIR Uridine HPLC Uridine NIR Adenosine HPLC Adenosine NIR Guanosine HPLC Guanosine Figure. Figure of comparation between HPLC data and NIR data. Figure. Content trend of each component in Isatis Radix extraction solution. Figure. Figure of uridine trend by NIR.

Figure. Figure of adenosine trend by NIR. Figure. Figure of guanosine trend by NIR. dine, adenosine, guanosine content to reach equilibrium while minutes for second extraction. When exploring the extraction methods in lab scale, the third extraction obtains less than one-tenth of content compared to the first extraction, so we discard the third extraction according to economic guideline. We can conclude that the

current Isatis Radix extraction method is the best one. ) As the long time of analysis and complex operation and complicated calculation of HPLC, the analysis of chromatographic data will take about hours from sampling to take calculated results. And the near infrared method just needs less than minutes. To save time and cost, using the near infrared method is the best choice. Use the first groups to establish near infrared model and near infrared data by chromatographic data validation. When matched, between near infrared detection results and chromatographic detection results of the same data, the deviations are within five percent and most of them within two percent. The monitoring data in industrial production can use near infrared detection instead of HPLC. ) This study just investigates the content of uridine, adenosine and guanosine of existing Isatis Radix production process. And for other active components such as alkaloids, amino acids, polysaccharides etc. in Isatis Radix, further studies are needed. ) The Isatis Radix studied is a common water extraction herb; while the extraction process is originated from traditional Chinese medicine decoct processes. Traditional testing methods to verify the use of modern technology are reasonable, efficient, reliable and suitable for guiding modern industrial production processes. References [] China Pharmacopoeia Committee () Chinese Pharmacopoeia, Volume I, PRC. Chinese Medical Science and Technology Press, Beijing,. [] Zhang, H.Y. () Clinical Application of Decoction of TCM Formula Granule. Journal of North China Coal Medical University,, -.