Geothermal Model of the Lahendong Geothermal Field, Indonesia

Similar documents
SUBSURFACE HYDROTHERMAL ALTERATION AT THE ULUBELU GEOTHERMAL FIELD, LAMPUNG, SOUTHERN SUMATRA, INDONESIA. Suharno 1, 2 and PRL Browne 2

SUB-SURFACE GEOLOGY AND HYDROTHERMAL ALTERATION OF WELLS LA-9D AND LA-10D OF ALUTO LANGANO GEOTHERMAL FIELD, ETHIOPIA

Heat Source Movements in Lahendong Geothermal Field and Its Affect to The Reservoir Characteristics

GEOTHERMAL ENERGY POTENTIAL FOR LONGONOT PROSPECT, KENYA. By Mariita N. O. Kenya Electricity Generating Company

Exploration of Geothermal High Enthalpy Resources using Magnetotellurics an Example from Chile

Geophysical Surveys of The Geothermal System of The Lakes District Rift, Ethiopia

WAMUNYU EDWARD MUREITHI I13/2358/2007

Resistivity Structures of Lahendong and Kamojang Geothermal Systems Revealed from 3-D Magnetotelluric Inversions, A Comparative Study

RECENT RESULTS FROM THE SAN JACINTO - TIZATE GEOTHERMAL FIELD, NICARAGUA

HIGH TEMPERATURE HYDROTHERMAL ALTERATION IN ACTIVE GEOTHERMAL SYSTEMS A CASE STUDY OF OLKARIA DOMES

Interpretation of Subsurface Geological Structure of Massepe Geothermal Area Using Resistivity Data

NUMERICAL MODELING STUDY OF SIBAYAK GEOTHERMAL RESERVOIR, NORTH SUMATRA, INDONESIA

Characterization of Subsurface Permeability of the Olkaria East Geothermal Field

The Initial-State Geochemistry as a Baseline for Geochemical Monitoring at Ulubelu Geothermal Field, Indonesia

Hydrothermal Alteration of SMN-X,Sumani Geothermal Area, West Sumatra, Indonesia

Update of the Geologic Model at the Las Pailas Geothermal Field to the East of Unit 1

Geothermometer, Geoindicator and Isotope Monitoring in Lahendong Wells during

An Overview of the Geology of Aluto Langano and Tendaho Geothermal Fields, Ethiopia. Solomon Kebede. Geological Survey of Ethiopia

INTEGRATED GEOPHYSICAL STUDIES OF THE ULUBELU GEOTHERMAL FIELD, SOUTH SUMATERA, INDONESIA

Geology and Hydrothermal Alteration of the Hverahlid HT-System, SW-Iceland

The Role of Magnetotellurics in Geothermal Exploration

Three Dimensional Inversions of MT Resistivity Data to Image Geothermal Systems: Case Study, Korosi Geothermal Prospect

Keywords: geophysics field camp, low to moderate, temperature, geothermal system, Mt Pancar, Indonesia

TORFAJÖKULL, ICELAND A RHYOLITE VOLCANO AND ITS GEOTHERMAL RESOURCE

Integrated Geophysical Model for Suswa Geothermal Prospect using Resistivity, Seismics and Gravity Survey Data in Kenya

Geophysics for Geothermal Exploration

Cubic Spline Regularization Applied to 1D Magnetotelluric Inverse Modeling in Geothermal Areas

Borehole Geology and Alteration Mineralogy of Well He-52, Hellisheidi Geothermal Field, SW-Iceland

GEOTHERMAL STRUCTURE AND FEATURE OF SULFIDE MINERALS OF THE MATALOKO GEOTHERMAL FIELD, FLORES ISLAND, INDONESIA

Geology and Hydrothermal Alteration in the Reservoir of the Hellisheiði High Temperature System, SW-Iceland

GEOTHERMAL POTENTIAL OF ST. KITTS AND NEVIS ISLANDS

Structural Geology tectonics, volcanology and geothermal activity. Kristján Saemundsson ÍSOR Iceland GeoSurvey

Heat (& Mass) Transfer. conceptual models of heat transfer. large scale controls on fluid movement. distribution of vapor-saturated conditions

Japan Engineering Consultants, Inc., Energy and Industrial Technology Development Organization,Tokyo, Japan

GEOTHERMAL WELL TARGET APPROACHES IN THE EXPLORATION STAGE

Geological Evaluation of the Waringin Formation as the host of a Vapor-Dominated Geothermal Reservoir at the Wayang Windu Geothermal Field

Geothermal Exploration in Eritrea

THE RESERVOIR OF THE RENDINGAN-ULUBELU- WAYPANAS GEOTHERMAL SYSTEM

Calc-alkaline Volcanic Rocks. Calc-alkali Volcanics. Fabric. Petrography. Compositional Classification. Petrography. Processes.

THREE DIMENSIONAL INVERSIONS OF MT RESISTIVITY DATA TO IMAGE GEOTHERMAL SYSTEMS: CASE STUDY, KOROSI GEOTHERMAL PROSPECT.

Aliabad-Morvarid iron-apatite deposit, a Kiruna type example in Iran

INFRARED AND SATELLITE IMAGES, AERIAL PHOTOGRAPHY

Geo-scientific Data Integration to Evaluate Geothermal Potential Using GIS (A Case for Korosi-Chepchuk Geothermal Prospects, Kenya)

MAGNETOTELLURIC INTERPRETATION OF THE KARAHA BODAS GEOTHERMAL FIELD INDONESIA

Geothermal Exploration in Eritrea

Figure 1: Location of principal shallow conductors at Alpala (anomalies C0-C10; 5 Ohm/m surfaces, red) and shallow zones of electrical chargeability

Imaging Reservoir Structure of Mt. Pancar Geothermal Prospect Using Audio-Frequency Magnetotelluric (AMT) and Gravity Technology

. Slide 1. Geological Survey of Ethiopia, P.O.Box 2302, Addis Ababa, Ethiopia

Evaluation of Subsurface Structures Using Hydrothermal Alteration Mineralogy A Case Study of Olkaria South East Field

TECHNICAL REVIEW OF GEOTHERMAL POTENTIAL OF NGOZI AND SONGWE GEOTHERMAL PROSPECTS, TANZANIA.

A Preliminary Geophysical Reconnaissance Mapping of Emirau Ground Water Resource, Emirau Island, New Ireland Province, PNG

THE ZUNIL-II GEOTHERMAL FIELD, GUATEMALA, CENTRAL AMERICA

GeothermEx, Inc. GEOTHERMAL RESERVOIR ASSESSMENT METHODOLOGY FOR THE SCIENTIFIC OBSERVATION HOLE PROGRAM, KILAUEA EAST RIFT ZONE, HAWAII TASK 1 REPORT

Geochemical Study of Ampallas Geothermal Area, Mamuju District, West Sulawesi Province

INTERGRATED GEOPHYSICAL METHODS USED TO SITE HIGH PRODUCER GEOTHERMAL WELLS

EXISTING GEOLOGICAL INFORMATION

Use of a Mise-a-la-Masse Survey to Determine New Production Targets in Sibayak Field, Indonesia

Structural Controls on the Chemistry and Output of the Wells in the Olkaria Geothermal Field, Kenya

Petrological Studies by Terry Leach at the North Carlin Trend, Nevada. Keith Bettles October 17, 2008

Resistivity Model Based on 2D Inversion of Magnetotelluric Sounding Data in Bacon- Manito, Southern Luzon, Philippines

DRILLING CONFIRMATION OF THE CASITA INDICATED GEOTHERMAL RESOURCE, NICARAGUA

Key Words: geothermal, exploration, extraordinary low water level, pressure imbalance, hidden vapor dominated reservoir ABSTRACT

Distribution of Sr and Ca Isotopes in Fluids of Lahendong Geothermal Field

Geothermal Resources of the Yonezawa District in Yamagata Prefecture, Northeast Japan.

NOTICE CONCERNING COPYRIGHT RESTRICTIONS

Integration of Surface and Well Data to Determine Structural Controls on Permeability at Salak (Awibengkok), Indonesia

Geophysical Exploration of High Temperature Geothermal Areas using Resistivity Methods. Case Study: TheistareykirArea, NE Iceland

BULLS-EYE! - SIMPLE RESISTIVITY IMAGING TO RELIABLY LOCATE THE GEOTHERMAL RESERVOIR

CO-EXISTING VOLCANISM AND HYDROTHERMAL ACTIVITY AT KELIMUTU, FLORES ISLAND, EASTERN INDONESIA

Determination of Calcite Scaling Potential in OW-903 and OW-914 of the Olkaria Domes field, Kenya

Using 3D/4D modeling tools in exploration of gold-polymetallic potential areas in Greece

STUDY OF CHACHIMBIRO AND CHACANA GEOTHERMAL PROJECTS, ECUADOR, AND VOLUMETRIC ASSESSMENT

Resistivity structure of Sumikawa geothermal field, northeastern Japan, obtained from magnetotelluric data. Toshihiro Uchida

Lab 3: Igneous Rocks

GEOTHERMAL BOREHOLE INVESTIGATIONS DURING AND AFTER DRILLING

The Reykjanes Seawater Geothermal System Its exploitation under regulatory constraints

DIRECTIONAL WELLS AT THE PAILAS GEOTHERMAL FIELD, SUPPORTING GEOLOGICAL AND STRUCTURAL DATA FOR THE GEOTHERMAL MODEL

THE SHALLOW HYDROTHERMAL SYSTEM OF LONG VALLEY CALDERA, CALIFORNIA

JOSH LEIGH Project Exploration Geologist June ASX Code AIV

Chapter 4 Rocks & Igneous Rocks

Taller de Geotermica en Mexico Geothermal Energy Current Technologies

DISCOVERY OF MINERALISED PORPHYRY & MAGNETITE-COPPER-GOLD AT KAMARANGAN

Geothermal Systems: Geologic Origins of a Vast Energy Resource

Magneto-telluric (MT) surveys in a challenging environment at Lihir Island, PNG

Drill locations for the 2015 program are highlighted in the geology map below.

STRATIGRAPHY AND HYDROTHERMAL ALTERATION ENCOUNTERED BY MONITOR WELLS COMPLETED AT NGATAMARIKI AND ORAKEI KORAKO IN 2011

Engineering Geology ECIV 2204

Applicability of GEOFRAC to model a geothermal reservoir: a case study

From Punchbowl to Panum: Long Valley Volcanism and the Mono-Inyo Crater Chain

Wind Mountain Project Summary Memo Feeder Program

Overview of Indonesian Geothermal System

EARTH SCIENCE. Geology, the Environment and the Universe. Chapter 5: Igneous Rocks

Chapter 4 8/27/2013. Igneous Rocks. and Intrusive Igneous Activity. Introduction. The Properties and Behavior of Magma and Lava

RECHARGE ELEVATION OF HOT SPRING STUDY IN THE MT

Occurrence of Sarawet hotspring: what affects the outflow?

3D MAGNETOTELLURIC SURVEY AT THE YANAIZU-NISHIYAMA GEOTHERMAL FIELD, NORTHERN JAPAN

Summary of geothermal setting in Geo-Caraïbes target islands

APPLICATION OF GEOPHYSICS TO GEOTHERMAL ENERGY EXPLORATION AND MONITORING OF ITS EXPLOITATION

Synthesis of Well Test Data and Modelling of Olkaria South East Production Field

A Poisson s Ratio Distribution From Wadati Diagram as Indicator of Fracturing of Lahendong Geothermal Field, North Sulawesi, Indonesia

Transcription:

Proceedings World Geothermal Congress 2010 Bali, Indonesia, 25-29 April 2010 Geothermal Model of the ahendong Geothermal Field, Indonesia ary Koestono 1, Eben Ezer Siahaan 1, Marihot Silaban 1, jalti Franzson 2 1 Pertamina Geothermal Energy, Jakarta, Indonesia 2 Iceland GeoSurvey, Reykjavik, Iceland hary_ka@pertamina.com, eesiahaan@pgeindonesia.com, marihots@plasa.com, hf@isor.is Keywords: ahendong geothermal field, reservoir permeability, hydrothermal alteration, temperature. ABSTRACT ahendong Geothermal Field is tectonically located in the northern neck arm of Sulawesi Island. The field is part of the depression of the Pangolombian caldera with clear structures in the eastern part but relatively open to the west. The depression of the Pangolombian caldera is being one of the most important with respect to the geothermal system in ahendong. Thermal structures on surface are mostly fault controlled with a dominant NW-SE and NE-SW directions, and are believed to control the permeability of the ahendong system. The ahendong geothermal field is hot water dominated system divided into two reservoirs, the Southern and Northern one. A total of twenty three wells have been drilled into these reservoirs. The Southern one has temperatures of 300 to 350 o C with dryness about 80%, and the northern one has lower temperatures between 250 to 280 o C with dryness around 30%. Three main alteration zones are encountered in this field namely smectite zone, smectite-chlorite and illite-prehnite-epidote zones. The smectite zone is mainly characterized by the appearance of low temperature clay and a layer with resistivity <10 ohmm. The smectite-illite-chlorite zone is characterized by the appearance of an acid layer and illite-prehnite-epidote zone is characterized by the appearance of chlorite, epidote, prehnite, and secondary quartz. The temperature distribution shows that the interesting site for geothermal resource utilization in the field is located in the NW, W, and SW direction of well pad -4 and W and SW direction of well pad -5. 1. INTROUCTION ahendong geothermal field is located at about 30 km south of Manado, in the northern arm of Sulawesi Island (Figure 1). The Sulawesi Island is formed due to an active subduction in the south eastern part (Mollusca sea) and northern part (Celebes sea). Regionally, this field is located in the west margin of the Tondano epression which extends about 20 km in northsouth direction and opens to the west. Within this depression is the Pangolombian rim circular in shape and is an important structure in ahendong geothermal system. This geothermal field was discovered in 1982 and geological, geochemical and geophysical works has been conducted since that time. Three shallow wells were drilled around inau ake in the same year. From 1982 to 1987, Pertamina drilled 7 exploration wells -1 and -5 in the northern reservoir system, -4 in the southern reservoir system and -3, -6 and -7 in the boundary margin of the prospect area (Robert, 1987; Siahaan, 2005). The development wells -8 to -16 at ahendong Geothermal Field were drilled from 1991 to 1998 and the first 20MW power plant was commenced in 2001. The development stage continued from 2005 to 2007 in which 7 production wells were drilled which generated electricity 2 X 20 MW for power plant Unit II and III and was commenced in 20087 and 2008. The paper will explain about the tectonic structure, hydrothermal alteration, reservoir, temperature, and the geothermal model of the system based on data from 23 wells. The geological data is mostly based on the cutting analysis of samples taken at 3 m interval. There are 7 production wells in well pad -4 and 13 are located in the southern block and 5 wells in pad -5 in the northern block, whereas well pad -7 in eastern part is reinjection wells. Figure 1. ocation map of ahendong Geothermal Field 2. GEOOGICA OUTINE 2.1. Regional Geology The geology of ahendong consists of hyaloclastites and lava flows intercalated with the sediment formation formed during the Miocene time. Tondano depression is the important structure in the area and is formed due to the big eruption which occured on the ate Miocene or Early Pliocene time. The stratigraphy of ahendong geothermal field can be divided into 3 lithological units i.e. Pre-Tondano, Tondano and Post Tondano Units. 1

Post Tondano Unit is commonly found covering the upper part of the stratigraphy and comprises pumice, tuff and volcanic breccia in the upper part and basaltic andesite in the lower part. The Post-Tondano unit consists of 2 sub-units, the Pra- Pangalombian and Post-Pangalombian Sub-units. The Pra- Pangalombian sub-unit mainly consists of basaltic andesite lava deposited in the northern and southern part of Pangalombian depression. The second sub-unit, the Post- Pangalombian, is composed of eruptions located in the central and peripheral of the depression. The chronological sequence from early to late deposition is described as basaltic andesite lava of Kasuratan, inau breccia consisting of volcanic breccia and pyroclastic rock, Tampusu basaltic andesite lava and pyroclastic rock, product of Mt. engkoan andesitic lava, obsidian and tuff breccia, an altered ground located in the northern side of Kasuratan village extending to Pangalombian rim, in eilem creek and in the eastern side of ahendong village (Figure 2). ake inau and its crater rim was formed due to the hydrothermal eruption activities and is believed to be the centre of surface thermal manifestations in the field. (Siahaan, 1999). 2.2. Geochemistry The surface manifestations that indicate a geothermal system in this field are such as hot springs, mud pools, fumaroles, and altered rock (Figure 3). The ahendong geothermal area can be divided into two groups of hot water based on their chemical characteristics of the Cl-B ratio as okon-mahawu group and ahendong- Tompaso group. okon-mahawu group is located in the Northern part and is characterized by low silica content and low temperature 2- while the concentration of Ca, Mg and SO 4 is relatively high. The ratio of Cl/B in this group is higher than the second group. The second group is ahendong-tompaso group. This group is located in the Middle and Southern part of the field. The temperature estimation based on the gas geothermometry is around 322 o C. Figure 3. Map showing the distribution of surface manifestation in the field (Siahaan, 1999). 2.3. Geophysics The geophysical methods used to assess the geothermal system are resistivity, MT and gravity and were conducted in this field since its discovery 1982. Figure 2. Geological and structural map of ahendong geothermal field (Siahaan, 1999). Tondano unit is a rhyo-dacitic pumice rich ignimbrites in the upper part, whereas the influence of micro dioritic intrusion in the lower part makes it difficult to determined its true lithological character. The last unit, the Pre-Tondano, consists of series of basaltic andesite, andesites, volcanic breccia, hyaloclastites and pyroclastic products. The sedimentary formation includes limestone and silty marl with foraminifera identified on wells -1, -2 and -3 (Robert, 1987). The results of Schlumberger resistivity (AB/2=1000 m) and magnetotelluric (MT-5 EX) showed that the width of the geothermal prospect area identified by low resistivity anomaly (<10 ohmm) is around 15 to 25 km 2. This prospect area has centred in around of inau ake (Figure 5). etailed MT survey was done in 2008 by modelling of 3 MT inversion and showed an updome resistivity structure at around inau ake. The updome resistivity structure is characterized by the resistivity value of 20-60 ohmm which is interpreted as the propilitic zone. This zone is covered by the conductor resistivity structure with value <10 ohmm as the clay cap and part of the argillic zone (Raharjo, et.al, 2008). 3. TECTONIC STRUCTURE The study on the distribution of the geological structure of the ahendong Geothermal Field has been carried out by 2

Pertamina since 1982. Ganda and Sunaryo (1982) mapped the geology of the area. ater in 1987, Geoservice studied the geology and structure of the field based on aerial photographs. Robert (1987) compiled the data of Geoservice together with the well data. ead on resistivity Survey was carried out by Pertamina in 1988. Aerial photograph, landsat interpretation and surface manifestation evaluation was done by Siahaan (1999). These are show low to no permeability due to silicification in the well fractures. Well -10 intersects the F-6 fault and Well -13 intersect F-1 fault (Azimudin and artanto, 1997). Well -14 intersects F-1 fault at 1470 m. Well -17 intersect F-8 fault at close to the surface. Well -18 intersect F-1 fault at 1468 m. No circulation loss is found in well -19. Well -20 and 21 intersects F-2 fault at 1048 and 1355 m, respectively. Well -22 intersects Pangolombian Rim at 2107. Well - 23 intersects the Pangolombian Rim at 1703-2000 m as indicated by total loss circulation and is an interesting target structure for northern part of the reservoir system in this field (Figure-6). 1000 m 500 m A 100 o C -1 RIM Acid condensate layer -5 F-2-7 A Smectite zone 0 m -500 m 200 o C 250 o C Smectitechlorite zone -1000 m -1500 m 300 o C Illliteprehniteepidote zone Figure 5. Geophysical map of the ahendong prospect area (Siahaan, 1999) Tectonically, five main structures were encountered in the ahendong geothermal field. The structures are rim Pangolombian, faults striking NE-SW, E-W, NW-SE and N- S. The Pangolombian structure is a caldera rim that is interpreted to provide the good permeability in the field. The NE-SW fault structure is normal and lateral fault, acting as the major volcanic axis. The E-W fault structure is lateral and a transcurrent fault. The NW-SE fault and N-S faults are normal faults which are interpreted to be provide a good permeability to the geothermal system (Robert, 1987). The important faults structure controlling the geothermal systems in the field are F-1 in the well pad -4 and 13 and F-2 and Pangolombian rim for the well pad -5. These three well pads are production site, whereas well pad -7 in the western part has the reinjection wells. The geological structure and the cross section are shown in the Figure 2 and 6. Well -1 and 2 intersects NW-SE fault and dipping SW at depths of 350 m and 650 m, respectively, but does not intersect the main structure at depth. No productive structure was intersected by well -3. Well -4 intersects the main F-1 structure at depth 2200-2250 m and Well -5 intersects the F-2 structure at 1170-1220 m (Figure 6). -6 intersects a NW-SE F-9 fault at depth of 780 m but failed to intersect a permeable structure in the production part. Well -7 intersects the Pangolombian Rim at depth 1950 m. No open fault structure is intersected by wells -8, 11 and 12. 3 Figure 6. Cross section A-A showing the wells, geological structures, temperature and alteration zones. 4. ATERATIONS MINERAOGY ydrothermal minerals in ahendong occur as replacements of primary minerals, replacement and deposition in vein and cavities. The replacement hydrothermal records the interactions between the wall rocks and the hydrothermal fluids, while space-filled minerals reflect the processes that affected the circulating fluid (Browne, 1988). The subsurface lithology of the ahendong Geothermal field is dominated by andesitic rocks except on the Tondano Unit that mostly comprises of rhyolitic type (Utami, et al, 2005). The alteration minerals at shallow depth are dominated by calcite, quartz, hematite and iron oxide. Anhydrite is formed by the partial replacement of plagioclase and pyroxene. Clay minerals commonly found are smectite and interlayered smectite-chlorite at shallow level. Chlorite relatively more common found than illite (Utami, et. al, 2005). In the depth of reservoir, epidote appears at depth around 133 mabsl in well -1, 115 to 200 mbsl in the pad - 4, 120 to 240 mbsl at pad -5 and deeper towards the pad of -13 where epidote is found at depth of about 400 to 500 mbsl (Figure 7), indicating an underlying hot propylitic zone. Epidote is found at temperature more than 240 o C-250 o C (Browne, 1978). eeper down in the wells -4, 10, 12 and 13, silicification occurs that probably results in sealing the permeability marked by the low permeability in these wells. 5. RESERVOIR The important factor in the reservoir of the geothermal system is that the permeability and this is controlled by the faults system. The reservoir rock is found in the ahendong geothermal system are mostly andesite as a part of the unit of Pra-Tondano.

1000 SSW -4-13 -1-5 -7 NNE 500 100 o C 200 o C Post -Tondano Formation Tondano Formation 0 250 o C Epidote Pre-Tondano Formation -500 300 o C -1000-1500 -11-18 -9-16 -23-20 -21-19 -5-1 -7-4/12-13 -2000 Figure 7. Cross section along B-B showing the different formation, temperature distribution and depth of the the first appearance of epidote. The reservoir system of the ahendong geothermal field is divided into two systems, the Southern and Northern one. The Southern one has temperatures of 300 to 350 o C with dryness about 80%, and the northern one has lower temperatures between 250 to 280 o C with dryness around 30%. These two blocks are separated by a structure trending N-S and interpreted to be acting as the pressure barrier. Some of the well data shows the existence of a shallow reservoir. The shallow reservoir in this field is encountered at a depth about 400 to 700 m. Shallow reservoir is found at a depth of about 650 m in well -1, -2, pad -4 and 5 indicating lateral outflow from a shallow aquifer (Robert, 1987, Siahaan, 2003; Siahaan, 2005). 6. TEMPERATURE ISTRIBUTION The formation temperature in the ahendong geothermal field was measured during the heating-up period. Most of the wells in the ahendong geothermal field have temperature ranging from 250 o C to 350 o C except wells -3, 6 and well pad -7 having temperatures below 150 o C (Figure 9). These wells are located at the boundary of the geothermal system. Generally, temperature distribution correlation between well pad -5 in the northern part and -4 and 13 in the southern part shows a temperature increase (Figure 9). The deep reservoirs are located at depths below 1000 meter characterized by the appearance of epidote and usually correspond to circulation losses during drilling. Total circulation loss occurs at different depth in several wells especially in -5, -7 and -23. The depth of circulation loss in the different wells is shown in Figure 8. Figure 8. Section E-W showing the depth of circulation loss during drilling in the each well 4 Figure 9. 3 view of temperature distribution in ahendong geothermal field In well pad -4 higher temperature distribution is observed in the W, NW and SW part of the well pad towards Mt. engkoan as compared to the eastern part. Well pad -5 also shows the same trend in W and SW direction of the well pad. This increase in temperature distribution is evidenced by an increase in maximum temperature from 250 o C in well -5 to 280 o C in well -23. This site which shows an increase in temperature distribution occurs below inau ake which is believed be the center of the upflow zone having temperature >300 o C. These higher

temperature distributions in both well pads make it an interesting site for geothermal resource utilization in the future. igh temperature minerals such as epidote, albite, wairakite and prehnite are especially found in wells -4 and 5 and corresponds to the measured temperature from the near neutral p alkali chloride water at temperature around 250 to 350 o C. Fluid inclusions study at well -5 shows that the homogenization temperature is around 227 to 269 o C (Utami et al, 2005). 7. GEOTERMA MOE OF AENONG The ahendong geothermal model was first prepared in 1987. Barnet (1987) did the reservoir assessment, and then the geological model based on 7 exploration wells giving emphasis to structure and the lateral and vertical formation temperature distribution by Robert (1987). The combination of the geological data, geophysics and wells data was modeled by Pertamina Geothermal. The model of Azimudin and artanto (1997) emphasized the well data after completion of 14 wells, conceptual model by Siahaan (1999), and the 3 inversion Magnetotelluric model by Raharjo, et al, (2008). Based on the geological analysis the subsurface condition of the ahendong Geothermal Field can be divided into three main layers namely: smectite zone, smectite-chlorite zone and illite-prehnite-epidote zone (Figure 10). The smectite zone is mainly characterized by the appearance of the low temperature clay mineral formed at temperatures between 100 to 150 o C. This zone is dominated by basaltic andesite and tuff ignimbrite from the Post Tondano and Tondano Units respectively. In the ahendong field, this zone behaves as the caprock and especially found throughout the wells -3, -6 and -7 (Siahaan, 2005). This layer is characterized by a conductive layer having resistivity <10 ohmm (Raharjo, et. al., 2008). The smectite-illite-chlorite zone is characterized by the appearance of chlorite in general and an acid layer with the presence of kaolinite in particular in wells -1 and 5. This acid layer observed in wells -1 and 5 occurs from the surface to 1000 m depth in the former and at shallow depth in the latter. This zone is located in the Tondano and Pra-Tondano Units. The illite-prehnite-epidote zone is characterized by the appearance of prehnite, epidote, and secondary quartz at depths of about 700 m in well -1 and 2 and at around 1000 to 1300 m in the well pad -4, 5, and 13. This zone is dominated by the Pra-Tondano Unit and marked by resistivity value of 20 to 60 ohm m (Siahaan, 2005; Raharjo, et. al., 2008). The reservoir fluid of the wells in the ahendong geothermal fluid is mainly dominated by the Neutral Chloride water except the wells -1, 3 and 7. In the western part, the shallow reservoir is associated with an acid fluid and several wells indicate a vapor dominated zone. The reservoir system is believed to center at around ahendong-kasuratan-inau and is characterized by the distribution of the surface thermal manifestation. The temperature profile shows different characteristics. Wells -1, 2 and 5 in the northern part have sharp change in temperature gradient at about 350 m depth that stable at 250 to 280 o C, whereas, most of the temperature profile of well pad -4 and 13 in the southern part show a change in the temperature gradient at depth 650 m where the gradient is stable at about 320-340 o C. The heat source for the geothermal system in this field is believed to be a magma cooling beneath the Mt. engkoan and Mt. Kasuratan (Siahaan, 2005). One of the important aspects to sustain the geothermal system is the recharge from the surrounding system. The recharge area of the system is from the Mt. Tampusu in the east and Mt. engkoan in the SW at an elevation of about 800-900 masl (Batan, 1991). SSW 1000-5 F-1-4 -13 F-6 F-8-1 F-2 F-3-7 RIM NNE 100 o C Inflow 500 200 o C 0 250 o C -500 Epidote -1000-1500 300 o C -11-18 -9-16 -23-21 -20-19 -5-1 -7-2000 -4/12-13 Smectite zone Smectite-chlorite zone Illite-prehnite-epidote zone Micro diorite Figure 10. Geothermal model of ahendong geothermal field (Modified from Siahaan, 2000). 5

8. CONCUSION The stratigraphy of ahendong geothermal field can be divided into 3 lithological units i.e. Pre-Tondano, Tondano and Post Tondano Units. Five main structures were encountered in the ahendong geothermal field. The structures are Pangolombian rim, and faults striking NE-SW, E-W, NW-SE and N-S. The reservoir system in the ahendong geothermal field is divided into two reservoirs, the southern part has temperatures of 300 to 350 o C with dryness about 80%, and the northern one has lower temperatures between 250 to 280 o C with dryness around 30%. Based on the temperature distribution, the interesting site for geothermal resource utilization is located in the NW, W, and SW direction of well pad -4 and W and SW direction of well pad -5. Three main alteration zone encountered in this field are smectite, smectite-chlorite and illite-prehnite-epidote zone. TE RECARGE AREA OF TE SYSTEM IS FROM TE RAINAGE SYSTEM OF MT. TAMPUSU AN MT. ENGKOAN. REFERENCES Azimudin, T., artanto,.b., 1997: Reevaluation of ahendong conceptual reservoir models. Pertamina Internal report (in Indonesian). Barnet, B., 1987.: Reservoir assessment of ahendong Geothermal Field, GENZ, SMS, Report for Pertamina, Jakarta. Batan, 1991, Isotope study of ahendong geothermal field, North Sulawesi, Report for Pertamina, Jakarta (In Indonesian) Browne, P.R.., 1978: ydrothermal alteration in active geothermal systems. Annu. Rev. Earth Planet. Sci., 6, 229-250 Ganda, S., and Sunaryo,., 1982: Preliminary study of the Geology of Minahasa Area, North Sulawesi. Pertamina Internal Report (in Indonesian). Geoservice, 1987: Aerial photograph study of the ahendong, North Sulawesi, Report for Pertamina, Jakarta (in Indonesian). Raharjo, I.B., Wannamaker, P.E., Timisela,.P., Arumsari, A.F., 2008: 3 inversion of Magnetotellurik, Study of the ehendong Gedothermal Field, Progress research, 33th AGI Annual meeting, Indonesia. Robert,., 1987: Geology Model of ahendong Geothermal Field: A guide for the development of this field, Report for Pertamina, Jakarta. Siahaan, E.E., 1999: Fault structure evaluation in ahendong Field based on aerial photo and landsat imagery, Pertamina Internal Report (in Indonesian).. Siahaan, E.E., 2000: Mineral alteration study in ahendong Geothermal Field, Pertamina Internal Report (in Indonesian). Siahaan, E.E., 2003: evelopment Plan of ahendong and Tompaso Geothermal Field, Pertamina Internal Report (in Indonesian).. Siahaan, E.E., 2005: Feasibility study of the ahendong Geothermal Field for Power Plant Unit IV and V, Pertamina Internal Report (In Indonesian). Utami, P., Browne, P.R.., Simmons, S.F., Suroto, 2005: ydrothermal alteration mineralogy of the ahendong Geothermal System, North Sulawesi: A progress report, Proceedings 27 th NZ Geothermal Workshop 2005. 6