The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD)

Similar documents
Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 385-ELSD Evaporative Light Scattering Detector

Agilent 1260 Infinity Evaporative Light Scattering Detector (ELSD)

Varian 385-LC. ELSD for Low Molecular Weight Compounds

Varian 380-LC. ELSD for Routine HPLC and GPC Analysis. Key Benefits

Utilizing ELSD and MS as Secondary Detectors for Prep HPLC and Flash Chromatography. Tips and Techniques to Optimize ELSD and MS based Purification

Evaporative Light Scattering Detector (ELSD)

for Acclaim Mixed-Mode HILIC-1 Column

Analysis of pharmaceuticals using HPLC with evaporative light scattering detection

Determination of the Composition of Natural Products by HPLC with Charged Aerosol Detection. Introduction. Black Cohosh. Corona Detector Parameters

Selecting Detectors for Compounds with No Optical Absorbance

Chemistry Instrumental Analysis Lecture 37. Chem 4631

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

No Chromophore? No Problem! Universal HPLC Detection. The world leader in serving science

Quantitation of Surfactants in Samples by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

LC800. Smart HPLC. Until now UHPLC From now Smart HPLC

Product Bulletin. ACE LC/MS and Rapid Analysis HPLC Columns. HPLC Columns

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Expanded capabilities in ammonium and amine detection

Polymer analysis by GPC-SEC. Technical Note. Introduction

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

GPC/SEC Practical Tips and Tricks. Thomas Dent Applications Scientist Agilent Technologies. October, 2011 Gulf Coast Conference

penta-hilic UHPLC COLUMNS

Proudly serving laboratories worldwide since 1979 CALL for Refurbished & Certified Lab Equipment

GPC/MS. Analysis of PET

Chapter 31 Gas Chromatography. Carrier Gas System

Nexera UC Unified Chromatography

Charged Aerosol Detection and Evaporative Light Scattering Detection Fundamental Differences Affecting Analytical Performance

High Performance Liquid Chromatography

High Performance Liquid Chromatography

HPLC. High Performance Liquid Chromatography (HPLC) Harris Chapter 25

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Ch.28 HPLC. Basic types of Liquid Chromatography Partition (LLC) Adsorption (LSC) Ion Exchange (IC) Size Exclusion (SEC or Gel Chromatography)

Evaluation of Several Columns and Solvents for Post-Extraction Gel Permeation Chromatography (GPC) Clean-up of Fish Tissue Prior to PCB Analysis

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

C18 Column. Care & Use Sheet

Electrospray Ion Trap Mass Spectrometry. Introduction

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

Acclaim Mixed-Mode WCX-1

Atomic Absorption Spectrophotometry. Presentation by, Mrs. Sangita J. Chandratre Department of Microbiology M. J. college, Jalgaon

Quantitation and Characterization of Copper Plating Bath Additives by Liquid Chromatography with Charged Aerosol Detection

Sensitive HPLC Method for Triterpenoid Analysis Using Charged Aerosol Detection with Improved Resolution

British American Tobacco Group Research & Development. Method - Determination of ammonia in mainstream smoke

Determination of Polyacrylic Acid in Boiler Water Using Size-Exclusion Chromatography with Charged Aerosol Detection

for Acclaim Trinity TM P1

Thermo Scientific. Acclaim Trinity P2. Column Product Manual. P/N: October Part of Thermo Fisher Scientific

LC and LC/MS Column Selection Flow Chart

Charged Aerosol Detection 101

Course goals: Course goals: Lecture 1 A brief introduction to chromatography. AM Quality parameters and optimization in Chromatography

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns

Analysis of DNPH-derivatized Aldehydes and Ketones using the Agilent 1220 Infinity LC System with Diode Array Detector

HPLC analysis of VFAs, Furfural and HMF

PDG.pdf G-20 CHROMATOGRAPHY 3 4 INTRODUCTION

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Chromatography- Separation of mixtures CHEM 212. What is solvent extraction and what is it commonly used for?

Pure Chromatography Consumables Pure flexibility. Pure specialization. Pure convenience.

Agilent s New Weak Anion Exchange (WAX) Solid Phase Extraction Cartridges: SampliQ WAX

Glossary of Common Laboratory Terms

Separation of Explosives in EPA 8330: Column Choices Optimize Speed, Resolution, and Solvent Use. Application. Authors. Abstract.

MultiVap8: Automated concentration system

Biochemistry. Biochemical Techniques HPLC

Atomic Absorption Spectrometer ZEEnit P series

HPLC Analysis of Non-volatile Analytes Using

Dionex IonPac AS28-Fast-4µm column

Analysis of Silicone Oils by High Performance Liquid Chromatography and Corona Charged Aerosol Detection

P R O D U C T B U L L E T I N. Fused-Core particle technology for hyper-fast and super-rugged HPLC columns

MODERN HPLC FOR PRACTICING SCIENTISTS

FAQ's. 1 - Which column would be the most appropriate for my application?

ChromTech HPLC System

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Corona Veo the Next Generation Charged Aerosol Detector

The end of. mass-speculation. MS Certified Vials Pre-cleaned and certified vials for mass spectrometry

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Pharmaceutical Analysis of API and Counter Ions in Complex Formulations in a Single Injection

[ CARE AND USE MANUAL ]

Optimizing GPC Separations


Available online Journal of Chemical and Pharmaceutical Research, 2012, 4(6): Research Article

Direct Analysis of Surfactants using HPLC with Charged Aerosol Detection

Shodex TM ODP2 HP series columns

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Tips & Tricks GPC/SEC: Quantify and Get More Than Molar Mass Averages

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Determination of trace anions in concentrated hydrofluoric acid

Instrumental Chemical Analysis

Dilution(*) Chromatography

FLASH CHROMATOGRAPHY

The Secrets of Rapid HPLC Method Development. Choosing Columns for Rapid Method Development and Short Analysis Times

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

A C18 Silica Column With Exceptional Temperature and ph Stability

Gas Chromatography (Chapter 2 and 3 in The essence of chromatography)

Quantitative Analysis of Caffeine in Energy Drinks by High Performance Liquid Chromatography

The analysis of organic acid content of additives, premix, feed, and water.

ProPac WCX-10 Columns

High Pressure/Performance Liquid Chromatography (HPLC)

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

High Performance Liquid Chromatography

HPLC solvents and mobile phase additives

Transcription:

The Low-Temperature Evaporative Light-Scattering Detector (LT-ELSD) Basically all compounds which are less volatile than the mobile phase can be detected. Detection is based on a Universal property of all analytes and does not require the presence of any chromophoric group, electroactive group, etc. The detector response is directly related to the mass of the eluted compound. Therefore it provides similar response factors for molecules with close structures and this is quite convenient to simplify quantification procedures or to make them possible when standards are not commercially available. Gradient mobile phases can be used to analyze samples. Since the mobile phase is removed from the eluent before detection, a gradient can be performed to optimize the separation. With ELS detection, a broad range of mobile phase modifiers such as AcONH 4, AcOH, HCOONH 4, HCOOH, CO 3 NH 4, TFA, HFBA, or N(C 2 H 5 ) 3 can be readily used to separate complex samples. Step 1: Nebulization Nebulize Eluent and select Small Droplets Nebulization: The Eluent from the column is mixed with an inert gas and goes through the narrow orifice of a nebulizer to generate a homogeneous mist. This fine mist is composed of droplets of mobile phase containing the compound of interest. SEDEX LT technology allows the selection of droplets as a function of their size in order to prevent larger droplets from entering the evaporation (drift) tube. Large droplets would require higher temperatures to be dried and are responsible for increased background noise.

Step 2: Evaporation Evaporate at Low Temperature Evaporation of the Mobile Phase: The nebulized eluent goes through a heated drift tube to evaporate the mobile phase. Solute molecules are obtained from the mist using a heated evaporation (drift) tube, at a low temperature. All SEDEX detectors are designed to evaporate mobile phases with high boiling points at very low temperatures. This unique feature minimizes the potential for evaporation or thermal decomposition of the compounds of interest, and makes the SEDEX LT technology a more reliable way to detect everything in the sample. Step 3: Detection Detect Scattered Light Detection: The stream of solid particles enters a flow cell which includes a light source and a photomultiplier. The intensity of the light scattered by the particles is directly related to the mass of the eluted compound. The solute molecules from the mist, assisted by Gas Supported Focusing (GSF), go through an optical head designed to measure the scattered light. GSF involves the addition of gas to focus the solute particles within the optical head for enhanced detection and safety.

All SEDERE detectors feature Low Temperature operation to ensure that the superb sensitivity is provided even for semi-volatile or thermally labile compounds. These detectors can be used with conventional analytical and preparative Liquid Chromatography, as well as with U-HPLC, HTLC, µ-hplc, GPC, Flash Chromatography, CCC and SFC. Why Low-Temperature evaporation is important in ELS detection? In an ELS detector, the nebulized eluent is evaporated by going through a heated tube. The temperature of this tube is undoubtedly the most critical parameter when optimizing detection. If the temperature is too high, semi-volatile or thermally labile compounds in the sample may evaporate or decompose and will not be detected. SEDEX detectors can evaporate solvents with high boiling points at low temperatures. As an example, Model 85LT can completely evaporate a mobile phase composed of 100% H2O with a flow rate of 1mL/min at 32 C and even below using small-bore LC columns! Also, our innovative design provides performance that is superior to that obtained from systems which require a special low temperature accessory! Know more about our comparative study Frequently Asked Questions 1. What is LT-ELSD? LT-ELSD stands for Low-Temperature Evaporative Light-Scattering Detection. It is a nearly- Universal and powerful detection mode for Liquid Chromatography and Supercritical Fluid Chromatography. LT-ELSD is used as a valuable alternative to Refractive Index and UV/Vis detection (for the latter particularly when analytes do not possess any chromophore) and is also considered as relevant complementary equipment to LC/MS. 2. When is LT-ELSD used? LT-ELSD provides a response under isocratic or gradient chromatography conditions independent of a compound absorbance, fluorescence or electro-activity. LT-ELSD can be used to analyze all solutes less volatile than the mobile phase. With SEDEX detectors, semivolatile and thermo-labile solutes can be analyzed with high sensitivities due to the Low- Temperature evaporation technology (patented). 3. What are the different applications of SEDEX Detectors?

SEDEX detectors can be used in different areas: conventional HPLC, U-HPLC, HTLC, µ-hplc, GPC, Preparative HPLC, Flash Chromatography, Counter Current Chromatography and Supercritical Fluid Chromatography. Elsewhere, SEDEX detectors can be connected to any Chromatography system via A/D converters or directly using RS-232 with our latest models. To shift from an application to another (e.g. HPLC to U-HPLC) just replace the nebulizer of the detector by the correct one. Nebulizer replacement is very easy and can be done in less than 2 minutes. 4. How does LT-ELSD work? In LT-ELSD, the mobile phase enters the detector, is nebulized with a clean gas and then evaporated in a drift tube; the remaining solute particles are finally detected by the way they scatter an incident light beam. The intensity of the light scattered from suspended particles depends on their size which depends itself on the size of the droplets generated by the nebulizer and the concentration of solute in the droplets. The droplet size produced by the nebulizer depends on the physical properties of the liquid and the relative velocity of the gas and liquid stream. The importance of all these parameters emphasizes the need for careful design and rigorous optimization of the different parts of SEDEX detectors. 5. What is the 3-step principle of SEDEX Detectors? Three important steps located in three different parts can be defined during the LT-ELSD process: Nebulization, Evaporation and Detection. 1. Nebulization This first step transforms the whole liquid phase flowing from the HPLC column into fine droplets. The smaller the droplet size, the lower the temperature needed to evaporate the liquid phase. With SEDEX detectors, the nebulizer and the nebulization glass chamber are designed to eliminate the biggest droplets of the solvent. 2. Evaporation This second step begins when the droplets are carried by the gas flow into the evaporation tube. SEDEX detector drift tubes have been designed to optimize the efficiency of the required evaporation with the lowest temperatures. The solvent is completely removed to produce particles of solutes. Practically, a temperature in the range 30-60 C is sufficient to evaporate most of the solvents used in HPLC.

3. Detection Analyte particles pass through a detection chamber where they are hit with an incident light beam. The amount of light scattered by the particles is measured using a photomultiplier tube and an electronic device. In SEDEX detectors a secondary gas inlet is used to concentrate the particles in the centre of the detection chamber to further increase sensitivity and to prevent this part from any contamination. 6. What are the compounds suitable for LT-ELSD? Basically, all compounds less volatile than the mobile phase are suitable for LT-ELSD. The boiling point is often used as an indication of compound volatility but it is sometimes misleading. A better indication of the volatility of a compound and hence LT-ELSD suitability is vapour pressure or latent heat of vaporization. 7. What are the mobile phases suitable for LT-ELSD? Most HPLC grade solvents are suitable for LT-ELSD. To get the lowest background signal, the main parameter to check is the Residue After Evaporation (RAE) which should be preferably below 1ppm. LC/MS grade solvents have very low RAE and provide excellent mobile phases for LT-ELSD. Since the mobile phase is evaporated before detection, any gradient system can be performed with absolutely no effect on the baseline when the solvents have got similar RAE levels. A broad range of volatile additives can be used with LT-ELSD. Among these: acids (formic acid, acetic acid, trifluoroacetic acid ), bases (ammonia, triethylamine ), buffers (ammonium formate, ammonium acetate, ammonium carbonate ), ion-pair reagents (pentafluoropropionic acid, heptafluororobutyric acid ), these compounds can conveniently modify the mobile phase to separate complex samples. Non-volatile additives (such as sodium or potassium phosphates or sulphates) are not compatible with LT-ELSD and should not be used. Indeed, they may contaminate and even drastically damage some parts of the detectors. However, these additives can be easily replaced by corresponding volatile ones. 8. What is the gas suitable for LT-ELSD? LT-ELSD can work either with air or nitrogen. However, for safety reason SEDERE strongly recommends using nitrogen. Indeed, mixing air (oxygen) with combustible solvents creates highly inflammable and possible explosive mixtures.

Gas may come from laboratory lines or gas cylinders and typical consumption is less than 3L/min. The gas does not require a high purity but it should be free of oil and particles. The standard operating pressure is 3.5bar (51psi). For better performances, SEDERE recommends using at least a gas regulator with filter (0.01µm) and manometer. 9. What is the sensitivity of SEDEX Detectors? For the majority of the solutes, the detection limits obtained with the latest SEDEX detector models frequently reach the very low nanogram levels on the column. For increased sensitivities, it is recommended to use lower internal diameter columns with lower solvent flow rates. 10. What typical RSD% values can be reached with SEDEX Detectors? If physical conditions of the analysis are maintained constant (sample volume, composition and quality of the mobile phase, flow rate, gas pressure and temperature of the detector), the reproducibility of the SEDEX detectors is quite good and reach typical Relative Standard Deviation values of the signal below 2%. Moreover, to further improve between-day RSD%, an internal standard can also be included in the samples. 11. Can SEDEX Detectors be used in U-HPLC? SEDEX 85LT is fully compatible with Ultra-High Performance Liquid Chromatography using sub-two micron particle column. Indeed, SEDEX 85LT has been designed and optimized to provide the highest efficiencies with peak widths below 1 second and analog data rate of 100Hz. 12. Can LT-ELSD be used for quantitative analysis? Yes. LT-ELSD is a mass sensitive detection. Using the same measurement conditions will provide the same signal intensity for the same concentration. The consequence of the light-scattering mechanisms is that LT-ELSD has a non-linear response. However, the relationship between concentration and signal intensity is nearly linear within one decade (with coefficients of correlation over 0.99) and this is quite satisfactory for most of QC quantitative analyses.

When larger ranges of concentration (two decades or more) are required LT-ELSD provides a sigmoid, logarithmic or quadratic response depending on the application, but the recent HPLC software allow the LT-ELSD users to easily select the equation which will directly provide the best correlation with the detector response. 13. What are the most important points to better use SEDEX Detectors? The most important part of SEDEX detectors is the nebulizer. It should be kept in a good condition. Just a simple preventive maintenance is necessary to preserve its performance and extend its lifetime. Make sure that the siphon of the nebulizer glass chamber is always filled and the liquid level is stable and equal at both sides. Make sure that the drain and exhaust tubes are correctly installed and the extraction of the exhaust device is not too strong. Elsewhere, other particular considerations should be brought to the mobile phase (low RAE), the gas (clean and with a stable pressure), the column quality (no phase bleeding ) and the HPLC equipment which should be in a good working condition. 14. What is the most important parameter to set with SEDEX Detectors? Evaporation temperature is the most important parameter in LT-ELSD. For non-volatile compounds, select a high evaporation temperature (e.g. 50-60 C) to completely evaporate the mobile phase, thus minimizing the baseline noise and obtain the highest sensitivities (highest S/N ratios). Elsewhere, the outstanding and unrivalled advantage of the Low-Temperature Technology of SEDEX detectors enables the highest sensitivities for semi-volatile and thermo-labile compounds. Indeed, just setting the temperature in the range of 30-40 C also provides the highest signals for these compounds without compromising the evaporation of the mobile phase. 15. Can SEDEX Detectors be controlled externally? The latest SEDEX models have got the RS-232 connection feature and can be controlled by chromatography software. Drivers are available for ChemStation, EZChrom Elite, Xcalibur and Clarity.

16. What are the main considerations when using SEDEX Detectors with other detectors? SEDEX detectors need to be the last detector when connected in series with UV or RI detectors. Alternatively, SEDEX detectors can be connected in parallel with MS detector by means of a flow splitter.