THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

Similar documents
THE IMPLEMENTATION OF A SCREENING WORKFLOW FOR ION MOBILITY QUADRUOPOLE TIME-OF-FLIGHT MASS SPECTROMETRIC ANALYSIS OF PFOS ISOMERS

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

CASE STUDY 3: Quantitative and Qualitative Analysis of Perfluoroalkyl Substances (PFASs) in Wildlife Samples Using the Xevo G2-XS Q-Tof GOAL

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

A Rapid Approach to the Confirmation of Drug Metabolites in Preclinical and Clinical Bioanalysis Studies

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

LC-HRMS: Challenges for Routine Implementation

AB SCIEX SelexION Technology Used to Improve Mass Spectral Library Searching Scores by Removal of Isobaric Interferences

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

DEVELOPMENT OF PFCs HIGH SENSITIVITY ANALYSIS METHOD APPLIED RETENTION GAP TECHNIQUE WITH UPLC/MS/MS Tatsuya Ezaki 1, Nobutake Sato 1, Jun Yonekubo 1,

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Toxicity, Teratogenic and Estrogenic Effects of Bisphenol A and its Alternative. Replacements Bisphenol S, Bisphenol F and Bisphenol AF in Zebrafish.

Q-TOF PREMIER DYNAMIC RANGE ENHANCEMENT AND ACCURATE MASS MEASUREMENT PERFORMANCE

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Multi-stage Mass Spectrometry up to MS 4 on a QTof System

A Case of Pesticide Poisoning: The Use of a Broad-Scope Tof Screening Approach in Wildlife Protection

INTRODUCTION OVERVIEW

Live Webinar : How to be more Successful with your ACQUITY QDa Detector?

Electron Transfer Dissociation of N-linked Glycopeptides from a Recombinant mab Using SYNAPT G2-S HDMS

Extraction of Cocaine and Metabolites From Urine Using ISOLUTE SLE+ prior to LC-MS/MS Analysis

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

Optimization of the sample preparation and extraction methodology

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

Improved Extraction of THC and its Metabolites from Oral Fluid Using Oasis PRiME HLB Solid Phase Extraction (SPE) and a UPLC CORTECS C 18

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

TargetScreener. Innovation with Integrity. A Comprehensive Screening Solution for Forensic Toxicology UHR-TOF MS

Determination of Pharmaceuticals in Environmental Samples

Supporting Information

APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEY WORDS. Simultaneous high-throughput screening of melamine (MEL) and cyanuric acid (CYA).

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

Analysis of Labeled and Non-Labeled Proteomic Data Using Progenesis QI for Proteomics

Applying MRM Spectrum Mode and Library Searching for Enhanced Reporting Confidence in Routine Pesticide Residue Analysis

Rapid and Accurate Forensics Analysis using High Resolution All Ions MS/MS

EPA Method 535: Detection of Degradates of Chloroacetanilides and other Acetamide Herbicides in Water by LC/MS/MS

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Assay Robustness Improvement for Drug Urinalysis Using FAIMS and H-SRM on a Triple- Quadrupole Mass Spectrometer

Metabolic Phenotyping Using Atmospheric Pressure Gas Chromatography-MS

Simplified Workflow and Improved Confidence in Screening Methods on Time of Flight Mass Spectrometry

UPLC Intact MASS Analysis Application Kit

FUTURE CONFIRMATORY CRITERIA

Quantitative Analysis of Opioids Using a Triple-Quadrupole GC/MS/MS

DETERMINATION OF PESTICIDES IN FOOD USING UPLC WITH POLARITY SWITCHING TANDEM QUADRUPOLE LC/MS/MS

Analyzing Compounds of Environmental Interest Using an LC/Q-TOF Part 1: Dyes and Pigments. Application. Introduction. Authors. Abstract.

GC-APCI IMS of Diesel

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

Analysis of Opioids Using Isotope Dilution with GCMS-TQ8030 GC/MS/MS. No. GCMS No. SSI-GCMS-1401

Basic Principles for Purification Using Supercritical Fluid Chromatography

Analysis of Synthetic Cannabinoids and Metabolites: Adding New Compounds to an Existing LC-MS/MS Method

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

Analysis of Pharmaceuticals and Personal Care Products in River Water Samples by UHPLC-TOF

Application Note. Edgar Naegele. Abstract

Maximizing Triple Quadrupole Mass Spectrometry Productivity with the Agilent StreamSelect LC/MS System

Fereshteh Zandkarimi, Samanthi Wickramasekara, Jeff Morre, Jan F. Stevens and Claudia S. Maier

Integrated approach to HPLC method development: Using all the tools in the chromatographer s toolbox

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Plasma Metanephrines and 3-Methoxytyramine by LC/MS/MS Using Agilent SimpliQ WCX SPE, 1290 Infi nity LC, and 6460 Triple Quadrupole LC/MS

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Profiling of Diferulates (Plant Cell Wall Cross- Linkers) Using Ultrahigh-performance Liquid. Chromatography-Tandem Mass Spectrometry

Characterisation of allergens in cosmetics by GC GC TOF MS with Select-eV variable-energy electron ionisation

4.1 MATERIALS 4.2 EQUIPMENTS

Overview. Introduction. André Schreiber 1 and Yun Yun Zou 1 1 AB SCIEX, Concord, Ontario, Canada

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Fast Screening and Quantitation of Perfluorinated Sources from Textiles using Chemical Ionization GC-MS

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

WADA Technical Document TD2003IDCR

The precursor (TBA) 3 [H 3 V 10 O 28 ] was synthesised according to the literature procedure. 1 (TBA = n tetrabutylammonium).

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

[ instrument specifications ]

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

MassHunter TOF/QTOF Users Meeting

Accurate Mass Analysis of Hydraulic Fracturing Waters

Fast and Reliable Method for the Analysis of Methylmalonic Acid from Human Plasma

TOMAHAQ Method Construction

WADA Technical Document TD2015IDCR

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Routine MS Detection for USP Chromatographic Methods

PesticideScreener. Innovation with Integrity. Comprehensive Pesticide Screening and Quantitation UHR-TOF MS

Overview. Introduction. André Schreiber AB SCIEX Concord, Ontario (Canada)

Chemistry Instrumental Analysis Lecture 37. Chem 4631

Identifying Disinfection Byproducts in Treated Water

LC-MS/MS Method for the Determination of Diclofenac in Human Plasma

Introduction to the Q Trap LC/MS/MS System

Welcome! Course 7: Concepts for LC-MS

NEW TOOLS FOR FINDING AND IDENTIFYING METABOLITES IN A METABOLOMICS WORKFLOW

Simultaneous analysis for forensic drugs in human blood and urine using ultra-high speed LC-MS/MS

FORENSIC TOXICOLOGY SCREENING APPLICATION SOLUTION

PosterREPRINT COMPARISON OF PEAK PARKING VERSUS AUTOMATED FRACTION ANALYSIS OF A COMPLEX PROTEIN MIXTURE. Introduction

Determination of Pharmaceuticals in Water by SPE and LC/MS/MS in Both Positive and Negative Ion Modes Application

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Screening of pesticides residues by the time of flight analyzer (ToF) : Myth or reality?

Extraction of Aflatoxins and Ochratoxin from Dried Chili Using ISOLUTE. Myco Prior to LC-MS/MS Analysis

A S ENSIT IV E M E T HO D FO R T H E D E T E RM INAT IO N O F ENDO C RIN E- D IS RU P T ING COM P OUNDS IN RIV E R WAT E R BY L C / MS/MS

Application Note. David A. Weil Zoltan Timar Michael Zumwalt Edgar Naegele. Abstract

Transcription:

THE IMPLEMENTATION O A SCREENING WORKLOW OR ION MOBILITY QUADRUOPOLE TIME-O-LIGHT MASS SPECTROMETRIC ANALYSIS O POS ISOMERS Ken Rosnack ken_rosnack@waters.com Ingrid Ericson Jogsten and Bert van Bavel (MTM Research Centre) Mike McCullagh, Leonard Dillon, Mike Hodgkinson, Lauren Mullin, & Jennifer Burgess (Waters Corporation) 2015 Waters Corporation 1

Overview POS analysis collaboration between Waters Corporation and Örebro University Challenges of POS analysis Instrumentation: Synapt G2-S and HDMS E Ion mobility Analysis of environmental samples for POS using HDMS E Experimental Results Screening approach vs Software enabled identification (Development of prototype software) Conclusions 2015 Waters Corporation 2

Introduction: Poly and perfluoroalkyl substances (PASs) 2015 Waters Corporation 3

PCs research Houde M, Martin JW, Letcher RJ, Solomon KR, Muir DC (June 2006). "Biological monitoring of polyfluoroalkyl substances: A review". Environ. Sci. Technol. 40 (11): 3463 73. doi: 10.1021/es052580b. PMID 16786681. Supporting Information(PD). 2015 Waters Corporation 4

POS Analysis Challenges Matrix effects, retention time shifts. Correct POS isomer identification: The physical, chemical and biological properties may be affected by perfluoromethyl branching. Source elucidation. Response factors of individual isomers. Increased scientific interest in toxicity, environmental transport, degradation and bioaccumulation of isomers. POS and TDCA as well as other cholic acids have similar isomeric profiles, retention times and MRM transitions (499 m/z 80m/z). Interferences can be mistaken for POS and lead to a positive bias. 2015 Waters Corporation 5

Chemical Structures POS and Cholic Acid Interference s TDCA POS TCDCA Taurodeoxycholate Perfluorooctane sulfonate Taurochenodeoxycholic acid C 26 H 45 NO 6 S= [M-H] - = 498.2889 C 8 H 17 O 3 S= [M-H] - = 498.9297 2015 Waters Corporation 6

ragmentation Series for POS 2015 Waters Corporation 7

HDMS E Uses high resolution MS and high efficiency ion mobility based measurements and separations. Both precursor ion and fragment ion information can be acquired in a single HDMS E experiment. This technique offers some unique advantages to profiling complex matrices. HDMS E can provide a route to specific and unambiguous identification, enabling the distinction of POS isomers. UPLC_SynaptG2-S_12031309_IEJ.raw : 1 2015 Waters Corporation 8

Ion Mobility Spectrometry Ion mobility spectrometry (IMS) is a rapid, orthogonal, gas phase separation technique which allows another dimension of separation. Separation is driven by electric fields not under vacuum. Compounds can be differentiated based on size, shape and charge. 2015 Waters Corporation 9

Ion Mobility Spectrometry (IMS) Small Compact Slide courtesy of Severine Goscinny, ISP-WIV, Belgium Large Extended 2015 Waters Corporation 10

SYNAPT G2-S High Definition MS - Ion Mobility Explained 1. Increased sensitivity 2. Ion mobility 3. Accurate mass Size Shape Charge 2015 Waters Corporation 11

Ion Mobility: an Orthogonal Dimension of Separation TO MS -9-8 -7-6 LC IMS -5-4 -3-2 -1 10n seconds 2015 Waters Corporation 0 1 2 3 4 n 12

MS E ragmentation in Trap or transfer Alternate Low and High Energy Scans 2015 Waters Corporation 13

Environmental samples SLU project Anna Rotander, Sara Persson Mink 2015 Waters Corporation 14

Extraction of environmental samples 1 g homogenized liver sample, Add labeled IS Repeated ACN extraction Vortex & ultrasonication Condition: MeOH and water Load samples Wash: 4 ml NaAc (ph 4) 4 ml 20% MeOH SPE, Oasis WAX Dry cartridges ENVI-carb Elute: 4 ml MeOH (discarded) 4 ml NH 4 OH iltration, performance standards added Instrumental analysis 2015 Waters Corporation 15

Experimental UPLC: Waters ACQUITY UPLC I-Class (equipped with PC kit) Column: Waters ACQUITY UPLC BEH C18 (100 mm x 2.1 mm, 1.7 µm) Column temperature: 50 o C Mobile phase low: 0.30 ml/min A: H 2 O:MeOH/ACN 70:30 (80/20, 2 mm Ammonium Acetate) B: MeOH:ACN 80:20 (2 mm Ammonium Acetate) Gradient Time(min) low Rate %A %B Initial 0.300 100.0 0.0 0.50 0.300 100.0 0.0 16.00 0.300 65.0 35.0 22.00 0.300 65.0 35.0 27.00 0.300 10.0 90.0 27.10 0.300 0.0 100.0 28.00 0.300 0.0 100.0 28.10 0.450 100.0 0.0 34.00 0.450 100.0 0.0 2015 Waters Corporation 16

Experimental MS: Waters SYNAPT G2-S Ionisation Mode: ES- Desolvation Temperature: 550 C Acquisition Modes: IMS MS E M/Z Range: 50-600 Acquisition rate: 10 spectra/second Capillary Voltage: 2.3 kv Cone Voltage: 15 V Drift Gas: CO 2 and N 2 Collision Energy Ramp: 35-75 ev IMS Wave Velocity Range: 400 m/s to 550 m/s IMS Wave Height: 40 V Mobility Drift Gas Mass Polarisability (10e -24 cm 3 ) Nitrogen N 2 28.0123 1.7403 Carbon Dioxide 44.0098 2.9110 2015 Waters Corporation 17

BPI Chromatogram for HDMS Analysis of Extract of Mink Liver for POS. 50559 Components Detected 2015 Waters Corporation 18

LC-HDMS E means... Increased Peak Capacity IMS PEAK CAPACITY Peak capacity 2015 Waters Corporation 19

Extracted ion chromatograms for matrix interferences and the POS isomers DL-09-007:205A 10 000ng/ul UPLC_SynaptG2-S_12031309_IEJ 100 A 20.25 21.97 1: TO MS ES- 498.906_498.971 0.1000Da 4.14e6 Isobaric Interference s (A,B) D 20.47 G POS Isomers (C-G) % 19.96 21.66 C 20.78 21.83 18.53 E B 0 16.00 16.50 17.00 17.50 18.00 18.50 19.00 19.50 20.00 20.50 21.00 21.50 22.00 22.50 23.00 23.50 24.00 24.50 Time 2015 Waters Corporation 20

Mobility plots for the isobaric interferences and POS isomers using N 2 drift gas. Ion Mobility Separation TDCA Interference s (N 2 Drift Gas) UPLC_SynaptG2-S_12031311_IEJ.raw : 1 Ion Mobility Separation POS Isomers (N 2 Drift Gas) UPLC_SynaptG2-S_12031311_IEJ.raw : 1 Dt = 6 ms = 2 ms Dt = 4 ms 2015 Waters Corporation 21

Mobility plots for the isobaric interferences and POS isomers using CO 2 drift gas. Ion Mobility Separation TDCA/TCDCA Interference s (CO 2 Drift Gas) UPLC_SynaptG2-S_12031309_IEJ.raw : 1 A POS Isomer Ion Mobility Separations (CO 2 Drift Gas) POS isomers UPLC_SynaptG2-S_12031309_IEJ.raw : 1 UPLC_SynaptG2-S_12031309_IEJ.raw : 1 Dt = 9.2 ms = 2.7 ms Dt = 6.5 ms B 2015 Waters Corporation 22

Ion Mobility Separation Component drift plot showing drift times vs retention time for nominally isobaric interferences (A) and POS isomers (B) 2015 Waters Corporation 23

Time and Mobility Aligned ragmentation m/z m/z Drift time Drift time Precursor ions Precursor ions Precursor and products are time aligned 2015 Waters Corporation 24

Ion Mobility Resolved TDCA (Interference A) with MS E Precursor and ragmentation Spectra 2015 Waters Corporation 25

POS (C) isomer, ion mobility resolved from isobaric interference TCDCA (A) at retention time 20.55 mins O OH S O C 3 2015 Waters Corporation 26

POS (D) isomer, ion mobility resolved from isobaric interference TCDCA (A) at retention time 21.14 mins O OH S O 2015 Waters Corporation 27

Unassigned POS (E), ion mobility resolved from isobaric interference TDCA (A) at retention time 20.88 mins 2015 Waters Corporation 28

POS ISOMER C 2015 Waters Corporation 29

POS ISOMER D 2015 Waters Corporation 30

POS ISOMER E 2015 Waters Corporation 31

POS ISOMER 2015 Waters Corporation 32

POS ISOMER G 2015 Waters Corporation 33

Summary for major POS isomers and matrix interferences POS ISOMER IDENTIICATION POS Isomers C 5mPOS J 3mPOS D IsoPOS E 2,2- perfluoro- methyl POS (tentative) 1mPOS G npos Drift Time (ms) Mass Measurement Error 4.59 4.27 3.4 ppm - 0.23 ppm 4.68 3.66 ppm 4.47 3.12 ppm 4.43 3.72 ppm 4.75-14.91 (2.68ppm HE) Retention Time (mins) 20.55 21.14 21.48 22.40 22.80 TDCA Interferences Drift Time (ms) Mass Measurement Error A TDCA 6.65 3.59 ppm B TCDCA 6.64 1.64 ppm Retention Time (mins) 20.88 22.52 A summary of drift times, retention times and isomer assigments for major POS isomers and co-eluting matrix. 2015 Waters Corporation 34

Screening database A screening database was created for branched POS isomers based on observed retention times and unique product ions 1m-POS, 3m-POS, 4m-POS, 5m-POS, 6m-POS, 4,4dim- POS, 3,5-dim-POS, 4,5-dim-POS, 5,5-dim-POS Environmental samples and a technical blend was analysed and compared against the database. The software filtered the results to include only isomers having a positively identified product ion. 2015 Waters Corporation 35

Component summary for POS screening of mink liver extracts 2015 Waters Corporation 36

Software enabled identification Extracted ion chromatogram and spectrum for both low energy (top) and high energy (bottom) collision states. Using the structure, proposed product ions were deduced from the observed spectral peaks, as indicated by the blue molecule icons. 2015 Waters Corporation 37

Drift time corrected spectrum Spectrum for the same chromatographic peak, 1-POS, with interference from TDCA evident in the top spectrum. The bottom spectrum is from the same chromatographic peak and injection, but with the removal of any ions that do not share the same drift time as 1-POS. 2015 Waters Corporation 38

Conclusions Co-eluting isobaric biological interference s TDCA and TCDCA have been resolved from POS isomers using ion mobility. Utilising CO 2 as a mobility drift gas further enhanced the mobility resolution between POS isomers and isobaric TDCA / TCDCA interference isomers. The enhanced mobility resolution induced using CO 2 has a drift gas also enabled distinctive drift times to be obtained for the POS isomers. Single component precursor ion and fragmentation spectra have been generated for POS isomers and TDCA / TCDCA interference POS isomers can be characterised without contribution from isobaric interference isomers of TDCA / TCDCA. UPLC IMS MS E facilitates accurate and informative data generation by isomerspecific analysis. This will be increasingly important as regulatory, scientific, and public awareness of the environmental impact of perflouralkylsubstances increases. 2015 Waters Corporation 39

Acknowledgements BENGT LUNDQVIST MINNE Waters Centre of Innovation Contact: ingrid.ericson@oru.se 2015 Waters Corporation 40

Thank You!!! Questions??? Ken Rosnack ken_rosnack@waters.com Ingrid Ericson Jogsten and Bert van Bavel (MTM Research Centre) Mike McCullagh, Leonard Dillon, Mike Hodgkinson, Lauren Mullin, & Jennifer Burgess (Waters Corporation) 2015 Waters Corporation 41