HFM-6 and HFM-7 OPERATOR S MANUAL

Similar documents
HFM-6, HFM-7, & HFM-8 OPERATOR S MANUAL

CR10TCR THERMOCOUPLE REFERENCE

MODEL 107 TEMPERATURE PROBE INSTRUCTION MANUAL

CR10XTCR THERMOCOUPLE REFERENCE

CR10XTCR THERMOCOUPLE REFERENCE

PTA-427 BAROMETRIC PRESSURE TRANSDUCER OPERATOR S MANUAL

User s Guide. Waterproof Palm ph Meter Model PH220. Introduction

3WHB10K 3-WIRE HALF BRIDGE TERMINAL INPUT MODULE INSTRUCTION MANUAL

SkyScan EWS-PRO - Manual -

Low Pressure Sensor Amplified Analog Output SM6295-BCM-S

MODEL HMP45C TEMPERATURE AND RELATIVE HUMIDITY PROBE INSTRUCTION MANUAL

Field Pro Operation and Installation Manual

SP-LITE SILICON PYRANOMETER INSTRUCTION MANUAL

FLT5A FLT5A. abc. abc. Thermometer User Guide. Thermometer User Guide. Internet:

Medium Pressure Sensor Analog Output

Small Gage Pressure Sensor

IRTS-P PRECISION INFRARED TEMPERATURE SENSOR INSTRUCTION MANUAL

TEST METHOD FOR STILL- AND FORCED-AIR JUNCTION-TO- AMBIENT THERMAL RESISTANCE MEASUREMENTS OF INTEGRATED CIRCUIT PACKAGES

RISE TIME EVALUATION OF THE HEAT FLUX MICROSENSOR (HFM) ON A HOT- AIR-GUN TEST RIG

AM 500A 500 WATT AM 1A 1 KILOWATT AM BROADCAST TRANSMITTERS. October, 1999 IM No

Technical Notes. Introduction. PCB (printed circuit board) Design. Issue 1 January 2010

NOVALYNX CORPORATION MODEL 110-WS-16BP BAROMETRIC PRESSURE SENSOR INSTRUCTION MANUAL

Small, Gauge Pressure Sensor

INSTRUCTION MANUAL. Laser Diode Sarcomere Length. Aurora Scientific Inc. 360 Industrial Parkway South, Unit 4 Aurora, Ontario, Canada L4G 3V7

Small Absolute Pressure Sensor

User Manual. Stick-Style Water-Resistant Infrared Thermometer with 8:1 Distance-to-Sight Ratio. Model with NIST-Traceable Calibration

Temperature Profile for 36 Marker Spheres on 3M 788 ACCR Conductor 3M Company

Coefficient of Thermal Expansion for 477-T16 ACCR

CM3 PYRANOMETER INSTRUCTION MANUAL

Calibrating the Thermal Camera

SKELESCOPE REFLECTOR TELESCOPE WITH TABLE TOP TRIPOD SK-100 INSTRUCTION MANUAL

ISOCON-6. 24V AC or DC POWERED ISOLATING SIGNAL CONVERTER

LUDLUM MODEL 42-5 NEUTRON BALL CART. August 2015 Serial Number PR and Succeeding Serial Numbers

BB1 & BB2 INSTALLATION & MAINTENANCE INSTRUCTIONS

Thermal Resistance Measurement

CAUTION: BEFORE YOU BEGIN, ALWAYS MAKE SURE THE WEAPON IS UNLOADED AND SAFE TO HANDLE.

OPERATION MANUAL. 3 in 1, IR, Type K/J/R/E/T, Pt 100 ohm THERMOMETER. Model : TM-2000

IR F ( C) ENGLISH INSTRUCTION MANUAL. Thermometer

Stick-Style Water-Resistant Infrared Thermometer for Foodservice Applications with 4:1 Distance-to-Sight Ratio Model

Latest generation testo air velocity & IAQ probes with cable handle. Instruction manual

EVERLIGHT ELECTRONICS CO., LTD.

566/568. Infrared Thermometers. Getting Started

Emissivity: Understanding the difference between apparent and actual infrared temperatures

Temperature Scales. Temperature, and Temperature Dependent on Physical Properties. Temperature. Temperature Scale

IC Temperature Sensor Provides Thermocouple Cold-Junction Compensation

3mm Advanced Super Flux LEDs B84-YSC-A1T1U1DH-AM

University of Connecticut Department of Electrical and Computer Engineering. ECE 4901: Fall 2017 Spring 2018

Franck-Hertz Experiment

MET ONE RAIN GAGE MODELS 380, 385, 380M, 385M

Owner's Manual NSL100B BUILDERS LEVEL NSL500B TRANSIT LEVEL

STATIC GAS MONITOR Type SGM/DEW Revision A of 20 aprile 2016

3mm Photodiode PD204-6B

OEM Silicon Pressure Die

IntraSense TM Series 1-French Wire-Connected Pressure Sensor SMI-1A AAUU

Avery Dennison LW Series Retroreflective Window Sticker Film Issued: July 2013

FIELD GUIDE FOR HORUS SCOPES

Power Resistors, for Mounting onto a Heatsink Thick Film Technology

Recommended Land Pattern: [mm]

Infrared Temperature Calibration 101 Using the right tool means better work and more productivity

INSTRUCTION MANUAL. CR10XTCR Thermocouple Reference. Revision: 1/03. Copyright (c) Campbell Scientific, Inc.

AN3002 Thermocouple measurement

HL-800K Infrared Laser Thermometer. -50 C to +800 C (13:1 ratio) User Manual

Recommended Land Pattern: [mm]

P-LED EALP03SXARA0-AM. Lead (Pb) Free Product - RoHS Compliant

SM98A Harsh Media Backside Absolute Pressure Series

MEASURING INSTRUMENTS

Chapter 1. Blackbody Radiation. Theory

e/m APPARATUS Instruction Manual and Experiment Guide for the PASCO scientific Model SE D 5/ PASCO scientific $5.

product manual H-4204 Proving Ring Penetrometer

5mm Silicon PIN Photodiode, T-1 3/4 PD333-3B/H0/L2

2N4921, 2N4922, 2N4923. Medium Power Plastic NPN Silicon Transistors 1.0 AMPERE GENERAL PURPOSE POWER TRANSISTORS VOLTS, 30 WATTS

PHS-25CW/3BW Benchtop ph Meter Instruction Manual

Power Resistors for Mounting Onto a Heatsink Thick Film Technology

5484BN/R7DC-AHJB/XR/MS(ELA)

Fischer 1508BTH-45 5" Brass Barometer with Temperature & Humidity User Manual

Safety Precautions WARNING If critical situations that could lead to user s death or serious injury is assumed by mishandling of the product.

Recommended Land Pattern: [mm]

Resistivity vs. Temperature of a Superconductor WARNING

Peltier Application Note

SK Series BOX PLOW INSTALLATION & OWNER S MANUAL TABLE OF CONTENTS

ISOCON-3 MAINS POWERED ISOLATING SIGNAL CONVERTER

Section 7. Temperature Measurement

MIL-STD-883E METHOD THERMAL CHARACTERISTICS

INSTRUCTION MANUAL. SP Lite2 Pyranometer. August Copyright 2017 Campbell Scientific (Canada) Corp.

Recommended Land Pattern: [mm]

INFRARED THERMOMETER Model : TM-959

D501 and D501-RS. Microscanner D-Series IR Thermometers. no effect. no effect. no effect. no effect no effect

WARRANTY AND ASSISTANCE

2N5655G, 2N5657G. Plastic NPN Silicon High-Voltage Power Transistors 0.5 AMPERE POWER TRANSISTORS NPN SILICON VOLTS, 20 WATTS

AN78Lxx/AN78LxxM Series

Fischer Instruments Chrome and Black Wood Base Weather Station with Barometer, Hygrometer, Thermometer and Quartz Clock User Manual

Bante210 Benchtop ph Meter Instruction Manual

PHS-25CW/3BW Benchtop ph Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

User s Manual: MODEL 904-T CLINOMETER PAK

Manual. CBT Sensor H3L3 v1.0. Updates to this manual found at:

Technical Data Sheet 3ψ Infrared Piranha

Integrated Circuits Thermal Test Method Environment Conditions - Natural Convection (Still Air)

WeatherHub2 Quick Start Guide

ASEN 2002 Experimental Laboratory 1: Temperature Measurement and an Blow Dryer Test

DeFelsko PosiTector Dew Point Meter with Anemometer (DPMA)

Transcription:

HFM-6 and HFM-7 OPERATOR S MANUAL Version 6.0 Copyright 2012 by Vatell Corporation Vatell Corporation P.O. Box 66 Christiansburg, VA 24073 Phone: (540) 961-3576 Fax: (540) 953-3010

WARNING: Read instructions carefully and completely before using the HFM. Improper usage could damage the unit. Save this manual for safety and operating instructions, as well as warranty information. FORWARD Thank you for purchasing the Vatell Heat Flux Microsensor (HFM). The HFM is designed to give fast, flexible heat flux measurements with built-in temperature compensation. To fully appreciate the capilities of your HFM, please read this Operator's Manual thoroughly. If you have any questions or need any assistance please contact: Vatell Corporation P.O. Box 66 Christiansburg, VA 24073 Phone: (540) 961-3576 Fax: (540) 951-3010 Email: mkt@vatell.com Please indicate model and serial number in all correspondence. UNPACKING AND INSPECTION The HFM package should include 1) The Vatell HFM 2) An individual calibration sheet for each HFM 3) This operator s manual. The face of the sensor is protected by a rubber cap. Please keep the cap and cover the sensor face with it whenever the HFM is not in use. If any of these items are missing or damaged, contact Vatell Corporation at the address listed in the Foreword section of this manual.

HFM-6 and HFM-7 Operators Manual Tle of Contents FORWARD. 2 UNPACKING AND INSPECTION... 2 USE OF THE VATELL HEAT FLUX MICROSENSOR. 4 Output from the HFM. 4 Example Measurement 6 Modes of Heat Transfer.. 7 Radiation... 7 Conduction.. 8 Convection.. 8 Mixed Mode Heat Transfer. 9 Sensor Temperature vs. Application Temperature.. 9 Sensor Response Time and Amplifier Gain. 10 HFM Calibration. 10 CARE AND MAINTENANCE.. 11 GLOSSARY OF HEAT TRANSFER 12 HFM SPECIFICATIONS 13 HFM MOUNTING. 14 WARRANTY.. 15 March 2012 Page 3

USE OF THE VATELL HEAT FLUX MICROSENSOR The Vatell Heat Flux Microsensor (HFM) will provide excellent heat flux measurement for a wide variety of applications, as long as it is used properly. This document will explain the use of the HFM and important factors to take into consideration when making measurements. The temperature correction equations described for the HFM and accompanying Vatell amplifier can be performed by the heat flux computation program on the CD that is shipped with these products, but are reviewed here for user edification. Output from the HFM Two measurements are made with the HFM. The first is a temperature measurement obtained from a resistance temperature sensing element (RTS) which consists of a pure platinum thin film deposited in a loop pattern around the outer edge of the sensor face. The second is a heat flux measurement obtained from a thermopile heat flux sensor (HFS) that occupies most of the surface area on the sensor face. The HFS signal should not be confused with the output from a thermocouple. The HFS acts like a differential voltage source, and so should not be grounded. Best results can be obtained by connecting it to a differential amplifier, such as the Vatell AMP-6 or similar amplifier. The RTS measurement is critical to proper heat flux measurement, because the HFS is temperature dependent. The RTS relies on the fact that the thin film resistance changes as a function of temperature. This function is close to linear for most temperatures of interest, although strictly speaking it is better described by a cubic polynomial. The function is characterized for each HFM at Vatell, and takes the form: T a R 3 b R 2 c R d (1) where: T is the temperature (in Celsius). a, b, c, d are the coefficients of the polynomial, which are given on the Calibration Data Sheet supplied with the sensor. R is the electrical resistance of the RTS (in ohms). Equation (1) could be used to compute the temperature if direct measurements of the RTS resistance are being made. Alternatively, the RTS may be driven by a current source, as is done with Vatell amplifiers, and the resulting voltage may be measured. In this case, zeroing the RTS output from the amplifier at some temperature between 0 C and 250 C, where the RTS response is most linear, can increase the precision of the measurement. The base resistance for this temperature is given by: R0 et0 f (2) where: R 0 is the RTS resistance (in ohms) calculated for temperature T 0 (in Celsius) at which the amplifier is zeroed. March 2012 Page 4

e, f are the coefficients describing the nearly linear temperature/resistance curve at low temperatures, which are given on the Calibration Data Sheet. The resistance of the RTS is related to the voltage output from the amplifier by: VRTS R R0 (3) ( I )( G ) RTS RTS where: V RTS I RTS G RTS is the voltage output of the RTS amplifier channel (in volts), which may be positive or negative. is the excitation current through the RTS used to generate V RTS (in amps), equal to 1x10-4 amps for Vatell amplifiers. is the amplifier gain for the RTS channel. For the AMP-6 and AMP-10, this value is given on the Gain Settings Lel on the bottom of the amplifier; for the AMP-8 it is given next to the BNC connector output. The resistance value from equation (3) can then be entered into equation (1) to determine the temperature. Once the temperature, T, is known, the heat flux can be computed from: VHFS GHFS q (4) g T h where: q is the heat flux (in W/cm 2 ). V HFS is the instantaneous amplified voltage signal from the HFS (in V). G HFS is the amplifier gain for the HFS channel. For the AMP-6 and AMP-10, this value is given on the Gain Settings Lel on the bottom of the amplifier; for the AMP-8 it is given next to the BNC connector output. g, h are coefficients for the relationship between sensitivity and temperature. These are given on the Calibration Data Sheet. The resistance of the RTS includes the resistance of the wires in the sensor s cle. One should note that during the calibration of the RTS at Vatell, the sensor is always connected to the measuring equipment through a standard 2 meter Vatell amplifier cle, which adds an offset to the resistance of out one ohm to the resistance of the sensor s cle. When using the HFM with a Vatell amplifier, no corrective action is required, as the offset is incorporated into the calibration data. If the Vatell amplifier cle is not used, or if a nonstandard cle length is used, the offset for the cle will be slightly different. In many cases, the difference of an ohm will not seriously impact heat flux measurements, but for the most accurate measurements, this difference in resistance should be applied to the coefficient f before computing the temperature. March 2012 Page 5

Example Measurement: The following is an example on using the HFM and the AMP-6 to measure heat flux. For our example, we want to measure the heat flux in a furnace that has a thermocouple to monitor its temperature during a slow temperature ramp. Note that if a Vatell amplifier is not availle, some other differential amplifier should be used to read the HFS voltage output in order to obtain the best signal. 1. First the RTS must be initialized. To do this, we need to measure the temperature of the sensor while the furnace is at low (preferly room) temperature. In our example furnace, the thermocouple used to monitor the furnace temperature can be used for our initialization temperature, as long as we ensure that the furnace and the HFM are at the same temperature. Since both the furnace and the HFM are at a uniform room temperature when we start, we can assume that this is the case. Be sure to allow the amplifier sufficient time to warm up, however; this takes approximately 8 minutes for Vatell amplifiers. This will prevent drift in measurements taken later. 2. The RTS offset potentiometer is adjusted until the amplifier output for the RTS channel measures close to zero volts. To find R 0 the resistance can be measured directly across the connector pins of the HFM, or it can be computed from the ambient temperature, as shown in step 3. 3. The thermocouple reads 27 C, which is our T 0. From the Calibration Data Sheet we find that e = 0.354994 /C and f = 147.308. Now with equation (2) we compute R e T 0 0 f o (0.354994/ C)(27 o C) 147.308 156.9 4. Because our system is thermally static at the moment, there is no heat flux, so we can zero the HFS signal. This is done by adjusting the HFS offset potentiometer until the amplifier output for the HFS channel measures close to zero. 5. When the furnace is turned on, the HFS begins to register a voltage, indicating that the sensor is measuring heat flux. Note that a positive voltage indicates heat flow into the sensor face and a negative voltage indicates heat flow out of the sensor face. 6. After 1 minute, we take a measurement. The HFS channel reads 0.290 V (290,000 V) and the RTS channel reads 1.03 V. The gain setting for the HFS and RTS channels are 1000 and 500 respectively. From the Gain Settings Lel on the bottom of the AMP-6, we find that these correspond to actual gains of G HFS = 980.6 and G RTS = 495.1. Recall that the excitation current for the Vatell amplifier, I RTS, is 1x10-4 amps. 7. The resistance of the RTS is computed using equation (3). For our example VRTS R R0 ( I )( G ) RTS RTS 103. V 4 156. 8928 ( 1x10 A)( 4951. ) 177. 6967 8. The temperature can now be computed from equation (1). Note that for accurate determination of the heat flux, the temperature measurement must be at the face of the sensor. This is why the RTS temperature value has to be used instead of some other March 2012 Page 6

temperature reading, such as that of the furnace thermocouple. The coefficients, which can be found on the Calibration Data Sheet, are a = -1.13938x10-5, b = 7.99230x10-3, c = 1.12145, and d = -301.613. The temperature is then T a R ( 1.13938x10 (1.12145)(177.6967) ( 301.613) 86.10 3 o b R C 2 c R d 5 )(177.6967) 3 (7.9923x10 3 )(177.6967) 9. Finally the heat flux, q, is computed from equation (4), using coefficient values from the Calibration Data Sheet of g = 0.026844 V/W/cm 2 /C and h = 73.2807 V/W/cm 2 : VHFS GHFS q g T h 290,000V 980.6 2 o o (0.026844V/W/cm / C)(86.10 C) 73.2807V/W/cm 3.912W/cm 2 Modes of Heat Transfer The HFM can measure heat flux in all three modes of heat transfer, radiative, conductive, and convective, but the nature of the heat transfer may impact measurements and so needs to be taken into consideration. Radiation Measurements and the Importance of Emissivity All heat flux transducers made by Vatell are calibrated using radiative heat sources, because they are the most consistently repeatle. However, the fraction of the radiation sorbed by the transducer is never 100%, and so the sorbed heat flux differs from the incident heat flux. The relation of incident and sorbed heat flux for a radiation source is given by q (5) q in 2 2 where is the emissvity All Vatell heat flux transducers are calibrated in terms of incident heat flux, so that for a radiative heat flux measurement, the heat flux is simply the output voltage divided by the sensitivity of the transducer. Vatell transducers are typically coated with a high temperature black paint, which has an emissivity of 0.86 and a fairly flat spectral response over most wavelengths of interest. The output voltage from the transducer is a function of the heat flux and the sensitivity, which can be expressed as: V S q S q (6) o in in March 2012 Page 7

where V o S in q in S q is the output voltage of the transducer is the sensitivity of the transducer for incident radiative heat flux; this number is given on the calibration certificate is the incident heat flux is the sensitivity of the transducer for sorbed heat flux is the sorbed heat flux The sensitivity to incident and sorbed heat flux is related by the emissivity as: S in =S (7) To find the incident heat flux from a radiation source, use the equation q V o in (8) Sin If the standard coating is removed or replaced with some other coating of known emissivity, the new emissivity must be used to calculate incident heat flux. For example, if the transducer is coated with colloidal graphite that has an emissivity of 0.82, the radiative heat flux would be given by q V o Standard in (9) Sin graphite Conduction Measurements When the heat flux is not from a radiation source, the sensitivity should be scaled by the emissivity because the emissivity only affects radiation measurements. Exercise caution when doing conduction measurements to prevent damage to the face of the HFM. When in contact with a hard or rough surface, Vatell recommends the use of a buffer like silicon grease to achieve good thermal contact without damaging the thin-film sensor. For a conductive heat flux, the governing equation is where q T V V o o k (10) n S Sin k is the thermal conductance T n is the thermal gradient with n as the unit vector normal to the surface across which the heat flux is being measured. Convection Measurements As with conduction measurements, when measuring convective heat flux the sensitivity must be scaled by the emissivity to determine the proper value. For convection, the heat flux equation is March 2012 Page 8

q V V o o ht (11) S Sin where h T is the heat transfer coefficient. is the temperature difference between the transducer and the fluid. The heat transfer coefficient is a function of the thermal conductivity of the fluid, and the fluid flow characteristics. Unfortunately fluid flow is extremely complex and difficult to model; consequently the heat transfer coefficient is difficult to determine except in an empirical fashion. Heat flux transducers are commonly used in fact to determine the heat transfer coefficient. By using the heat flux measurement in conjunction with temperature measurements of the fluid and the transducer face to obtain a T, the heat transfer coefficient can be found. This procedure assumes that the heat transfer coefficient for the transducer and the surrounding system are the same, so that the incident and sorbed heat fluxes are equal. The accuracy of this assumption will vary with different system configurations and materials. In general, the less the transducer alters the system the better. Measurements with Mixed Modes of Heat Transfer All three modes of heat transfer can be measured as described ove. When radiation is mixed with convection however, there is the question of what fraction of the heat flux needs to be corrected for emissivity, and what fraction does not. Ideally the different modes can be isolated so that the question does not occur; for example, using a radiometer to view only radiation sources. If the modes cannot be differentiated experimentally, some intelligent estimates of the relative fractions of the heat flux that each mode contributes must be made. In these cases the emissivity of the HFM should be as high as possible to minimize error. Sensor Temperature versus Application Temperature The HFM has an RTS to monitor the temperature of the substrate on which the thermopile has been deposited, in order to account for temperature variations in the HFS signal. The substrate temperature that the RTS measures should not be taken as the transient temperature of the test surface or the heat flux source. This is because the thermal gradient through the test surface and the HFM will not be the same unless the system is in thermal equilibrium. Consequently the RTS will register a transient temperature somewhere between the test surface temperature and the ambient surface temperature, as depicted below. Heat Source Test Surface Temperature T 2 Substrate Temperature T 3 Thermal Gradient HFM T 2 = T 1 + n(t) T 3 = T 1 + m(t) m n for transient March 2012 Page 9 T Ambient Surface Temperature T 1

The RTS can be used to measure the test surface temperature once the system is in thermal equilibrium, provided that the test surface is at a uniform temperature. In such a case the temperature gradient through the HFM and the test surface will be the same because of the high thermal conductivity of the HFM. Sensor Response Time and Amplifier Gain The time constant of the uncoated HFM is 17 s, which give it a 0-95% rise time (R) of 50 s. For a coated HFM, those numbers are 300 s and 900 s respectively. The measured response may be slower than that however, because it is dependent on the bandwidth and gain of the amplifier being used. There is an inherent trade-off between bandwidth and gain. This is usually expressed in the Gain-Bandwidth product F = GB (12) which is a constant for simple amplifiers. Consequently, higher gains result in lower bandwidth. To take full advantage of the speed of the HFM, the bandwidth of the amplifier should be B 2 2 R 50x10 s 6 40kHz Knowing the minimum bandwidth required for an application, the maximum gain can be computed. For example, to fully utilize the time response of the HFM with an amplifier having a Gain-Bandwidth product of 1 MHz, the maximum gain would be F G B 1MHz 25 40kHz For more sophisticated amplifiers, like the Vatell AMP-6 or AMP-10, the Gain-Bandwidth product is not necessarily constant. Refer to the specification sheet to determine bandwidth at any given gain. To keep signal noise to a minimum, one should set the gain as high as possible while keeping the bandwidth large enough to achieve the needed time response. HFM Calibration Each HFM is individually calibrated in a multi-step procedure. The first step is to remove hysteresis in the RTS. The hysteresis effect causes the temperature versus resistance curve of the RTS to shift as the sensor is heated and cooled, so that the resistance for a given temperature changes with each temperature cycle. The more a sensor is temperature cycled, however, the less pronounced this shift becomes. For purposes of the HFM, the hysteresis becomes negligible after several temperature cycles, the exact number of which has been empirically determined and is conducted on each sensor before the next calibration step. March 2012 Page 10

The RTS is then characterized in a computer-controlled furnace that maps resistance values to corresponding temperature values. From these data points a curve fit is performed to acquire the coefficients for equation (1). The linear low temperature portion of this curve (between 0 C and 250 C) is used to generate the linear fit for the coefficients for equation (2). Finally the HFS is calibrated by comparing its output voltage (V HFM ) against the output voltage of a standardized reference heat flux gage (V ref ) when each gage is exposed to the same radiation heat flux source (q). Both the HFM and the reference gage are coated with the same hightemperature black paint, which is a high emissivity coating (so that HFM = ref = 0.86). The sensitivity of the HFM (S HFM ) is calculated from the sensitivity of the reference gage (S ref ) by q S )( V ) ( S )( V ) (13) ( HFM HFM ref ref Because the HFM is calibrated to incident heat flux, the emissivity is factored into the sensitivity automatically. Equation (10) is applied to a whole series of data points during the calibration, allowing a linear fit of the data so that the coefficients of equation (4) can be obtained. CARE AND MAINTENANCE Proper care of the HFM will insure good performance throughout its lifetime. Vatell recommends regular calibrations to maintain optimal measurements. Sensor Face Although the HFM has a protective alumina coating over the surface, it is a thin-film device and as such it should be handled with care. To prevent altering the surface emissivity, the face of the sensor should never be touched (except in the case of a conduction measurement, and then care should be taken not to damage the thin-film). If the face of the sensor needs to be cleaned, use dry compressed air to dust it off. For more extensive cleaning, please return the HFM to Vatell for recoating and recalibration. Cles The Teflon cles on the low temperature HFM units and at the connector end of the high temperature units are durle and flexible, with a bend radius equal to the diameter of the cle. They can take a maximum temperature of 200 C. Note that the epoxy in the transition ferrule on the high temperature sensors can only go up to 130 C. The metal Inconel cles on the high temperature sensors can survive much higher temperatures, up to 600 C, but have limited flexibility, having a bend radius of 2.5 cm. Although the Inconel cles can be straightened and bent again, repeated bending should be kept to a minimum. March 2012 Page 11

GLOSSARY FOR HEAT TRANSFER As in any technical discussion, keeping the terminology straight is important. Refer to this glossary if things start to get confusing. Heat is the amount of energy moved across a thermodynamic barrier, and is measured in Joules (J). Heat transfer is the rate at which energy moves across the thermodynamic barrier, measured in Watts (W), that is, Joules per second. Heat transfer occurs in three different modes, conduction, convection, and radiation. Heat flux is the rate of energy transfer per unit area, expressed in W/m², W/cm², or similar units. Heat flux can be positive or negative, depending on the direction of heat transfer. Temperature is a fundamental property that indicates the internal energy of matter. Any temperature scale (Celsius, Fahrenheit, etc.) may be used as long as the units are kept consistent. Conduction is a mode of heat transfer through a substance, either solid or fluid, on a molecular level as a result of a temperature gradient being present. Convection is a mode of heat transfer when there is fluid flow. As in conduction, a temperature gradient must be present, but convection is influenced by fluid flow, which alters the temperature gradient. Radiation is a mode of heat transfer that occurs via electromagnetic radiation, and does not require any transport medium or material. Emissivity is the ratio of the actual energy emitted by a real body to that emitted by a blackbody. Emissivity can be considered equal to sorptivity for a gray body; that is a body whose emissivity is independent of wavelength and which reflects radiation in a diffuse manner. Most objects can be reasonly approximated as gray bodies. A thermocouple is used to measure temperature. It consists of a pair of junctions between two different metals that will produce a voltage proportional to the temperature difference between the junctions of the wires due to the Seebeck effect. Commercially availle thermocouples will appear to have only one junction; the second junction is essentially where the two leads are connected to a voltmeter or electronic thermometer. For a thermocouple to give an accurate reading the second junction must be at a reference temperature; frequently this is taken to be room temperature. For more accurate measurements, the second junction is lowered to a known temperature, such as the ice point. A thermopile is an array of thermocouples. By connecting many thermocouples in series, the temperature sensitivity is increased, because the thermocouple voltages add when linked in series. Like a thermocouple, the thermopile reads the temperature difference between two points. For a heat flux transducer, these two points are the top and bottom layers of the thermopile. March 2012 Page 12

HFM SPECIFICATIONS HFM Model HFM-6D/H HFM-7E/H HFM-7E/L HFM-8E/L HFM-10 Time Response (µs) 17 (300) 17 (300) 17 (300) 17 (300) 17 (300) uncoated (coated) Minimum Sensitivity 10 150 150 150 150 (µv/w/cm²) Max Face 800 600/400 350 350 350 Temperature* ( C) Metallurgy Pt/Pt-Rh NiCr/CuNi NiCr/CuNi NiCr/CuNi NiCr/CuNi Temperature Sensor RTD RTD RTD Thermocouple None Housing material Nickel Nickel Copper & Copper & Brass Copper Brass Cle Mineral sheath Mineral sheath Teflon coated Teflon coated Teflon coated *Max face temperature listed; max cle temperature is 600 C for E/H units and 200 C for others. HFM-7E/H max face temperature lists short term and continuous use temperature respectively. Transducer Calibration Accuracy: ±3% Repeatility: 2% Field-of-View: 180 March 2012 Page 13

HFM MOUNTING March 2012 Page 14

WARRANTY Vatell Corporation warrants that this product will be free from defects in materials and workmanship for a period of 90 days from the date of shipment. If the product proves defective during this warranty period, Vatell Corporation, at its option, either will repair the defective product without charge for parts and lor, or will provide a replacement in exchange for the defective product. In order to obtain service under this warranty, the customer must notify Vatell Corporation in writing of the defect before the expiration of the warranty period and make arrangements for service. The customer shall be responsible for packaging and shipping of the defective product to Vatell Corporation with shipping charges prepaid. Vatell Corporation will pay for the return of the product to the customer, if the shipment is to a location within the United States of America. The customer is responsible for paying all shipping charges, duties, taxes, and any other charges for products returned to locations outside of the USA. This warranty shall not apply to any defect, failure or damage caused by improper use or improper or inadequate maintenance and care. THIS WARRANTY IS GIVEN IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED. VATELL CORPORATION DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VATELL CORPORATION'S REPAIR OR REPLACEMENT OF A DEFECTIVE PRODUCT IS THE SOLE AND EXCLUSIVE REMEDY PROVIDED TO THE CUSTOMER FOR WARRANTED DEFECTS. VATELL CORPORATION WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES. March 2012 Page 15