Modeling of Polluted High Voltage Insulators

Similar documents
EVALUATION OF FLASHOVER VOLTAGE ON POLLUTED INSULATORS WITH ARTIFICIAL NEURAL NETWORK

(Online First) Improved mathematical model of polluted insulators nonlinear behaviour under ac voltage based on experimental tests

ELECTRIC FIELD AND VOLTAGE DISTRIBUTION ALONG INSULATORS UNDER POLLUTION CONDITIONS. V T Kontargyri N C Ilia I F Gonos I A Stathopulos

Comparison between artificial neural networks algorithms for the estimation of the flashover voltage on insulators

Experimental Study of the Artificial Neural Network Solutions for Insulators Leakage Current Modeling in a Power Network

The Lightning Study of Overhead Transmission Lines

Simulation of the Electric Field on Composite Insulators Using the Finite Elements Method

Finite Element Analysis of Disc Insulator Type and Corona Ring Effect on Electric Field Distribution over 230-kV Insulator Strings

Performance analysis of 1200 kv ceramic disc insulator string under normal and faulted conditions

Insulator Selection Tool IST 2018

Electric Field and Potential Distributions along Non-Ceramic Insulators with Water Droplets. Integrated Engineering Software - Website Links

BP 145 RP, Biskra, Algeria

COMPUTER METHODS FOR THE DETERMINATION OF THE CRITICAL PARAMETERS OF POLLUTED INSULATORS

Flashover Performance of Station Post Insulators under Icing Conditions based on Electric Field Distribution

A Review of the Dynamic Modelling of Pollution Flashover on High Voltage Outdoor Insulators

Insulator Contamination Forecasting Based on Fractal Analysis of Leakage Current

Power System Engineering Prof. Debrapriya Das Department of Electrical Engineering Indian Institute of Technology, Kharagpur

Modeling of Transmission Line and Substation for Insulation Coordination Studies

SCIENCE & TECHNOLOGY

Measurement and simulation of the voltage distribution and the electric field on a glass insulator string

Electric Field Analysis and Experimental Evaluation of 400 kv Silicone Composite Insulator

Electric Field Stress Calculation on High Voltage Insulator

Measurement and simulation of the electric field of high voltage suspension insulators

3D modeling of Electrical Field and Electrical Potential in different contamination condition in Polymeric Insulator

I n many cold-climate regions of the world, overhead

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Aging Detection of Glass Disc Insulator by Using Infrared Camera

EFFECT OF ATMOSPHERIC CONDITIONS ON CABLE TERMINATION TO SWITCHGEAR

Effect of Humidity on the Flashover Voltage of Insulators at Varying Humidity and Temperature Conditions

EFFECT OF CLIMATIC VARIATIONS ON POLLUTION DEPOSIT ON ELECTRIC INSULATION AND RELATED FAILURE

INTRODUCTION. The variation of the voltage distribution of an insulator string with ambient conditions has been studied

EFFECT OF DIELECTRIC BARRIERS TO THE ELECTRIC FIELD OF ROD-PLANE AIR GAP

Transient analysis of the behaviour of grounding systems consisted by driven rods

Collation Studies of Sequence Impedances for Underground Cables with Different Layouts

Modeling of High Voltage Insulator Strings through Finite Element Method

Measurement of wettability for polymer materials using non-contact surface resistivity

Dynamics and Modeling of AC Arc on Surface of Ice

Electrical, Electronic and Computer Engineering ENEL4HB - High Voltage 2

Winai Onchantuek, Boonruang Marungsri, Anant Oonsivilai, Thanatchai Kulworawanichpong. WSEAS TRANSACTIONS on POWER SYSTEMS

IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 22, NO. 1, JANUARY /$ IEEE

Evaluation of the risk of failure due to switching overvoltages of a phase to phase insulation

Reliability Enhancement of Line Insulator of a Transmission System using Artificial Neural Network Sumit Mathur #1, G.K. Joshi* 2

Copyright 2014 IEEE. Paper presented at 2014 IEEE conference on electrical insulation and dielectric phenomena, Des Moines, USA, October, 2014.

VOLTAGE DISTRIBUTION ACROSS STRING INSULATORS BY SPHERE GAP METHOD

EXPERIMENTAL DEVELOPMENTS ON SOIL IONIZATION: NEW FINDINGS

Study of Insulator Flashovers caused by Atmospheric Ice Accumulation

Fatima Michael College of Engineering & Technology

Electro - Principles I

Estimation of the Electric Field and Potential Distribution on Three Dimension Model of Polymeric Insulator Using Finite Element Method

Electric Field and Potential Distributions along Dry and Clean Non-Ceramic Insulators. Integrated Engineering Software - Website Links

On Designing of a High Voltage Standard Capacitor Using a Semi-Analytical Field Computation Method

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

Evaluation of Critical Components of Non-Ceramic Insulators In-Service: Role of Defective Interfaces

A New High Voltage 4H-SiC Lateral Dual Sidewall Schottky (LDSS) Rectifier: Theoretical Investigation and Analysis

SIGNIFICANCE OF TRANSPOSITION FOR 220KV TOWER

CHAPTER 5 ANALYSIS OF ELECTRIC FIELD AND VOLTAGE DISTRIBUTION

Thermal Analysis by Conduction Convection and Radiation in a Power Cable

STUDIES ON LIGHTNING CHARACTERISTICS

/14/$ IEEE

Simulation of Partial Discharge in Solid Dielectric Material

EPRI Lightning Protection Design Workstation

Analysis and Prediction of Electric Field Intensity and Potential Distribution along Insulator Strings by using 3D models

Electromagnetic Theory Prof. D. K. Ghosh Department of Physics Indian Institute of Technology, Bombay

Temperature and Field Dependence of Field Grading Tubes for Medium Voltage XLPE Cable Joints

HUMIDITY INFLUENCES ON THE BREAKDOWN OF ROD-PLANE GAPS UNDER POSITIVE IMPULSES IN ATMOSPHERIC AIR

DC Flashover Performance of Various Types of Ice-Covered Insulator Strings under Low Air Pressure

Study on the design of semiconducting anti icing RTV coatings

Modeling Electric Field and Potential Distribution of an Model of Insulator in Two Dimensions by the Finite Element Method

Finite Element Analysis on Post Type Silicon Rubber Insulator Using MATLAB

An Introduction to Insulation Resistance Testing

Prof. Dr. Magdi El-Saadawi

Code No: RR Set No. 1

Analysis of Very Fast Transients in EHV Gas Insulated Substations

Comparing Experimental Apples and Oranges with Quantile-Quantile Plots

Outline. ECE 477 Digital Systems Senior Design Project. Module 7 Capacitor Selection Guidelines. Film Ceramic Electrolytic Miscellaneous

Capacitor Construction

Arrangement of conductors in 220 kv double circuit line to reduce E-fields in view of public exposure

Simulation Studies of Composite Insulators used in High Voltage Transmission

Insulation Resistance and Polarization of Rotating Machines

A Novel Optimized Design for Busbar Structures using Finite Element Methods

Test method to assess the suitability of materials and surfaces to avoid problems from static electricity by measurement of capacitance loading

Finite Element Method Application in Analyzing Magnetic Fields of High Current Bus Duct

FEATURES APPLICATIONS DESCRIPTION QUICK REFERENCE DATA. PILKOR components

Study of Time Correlation Between Lightning Data Recorded by LLS and Relay Protection

Exponential Expression of Relating Different Positive Point Electrode for Small Air Gap Distance

Comparison of Radial Movement of Metallic Particles in a Single Phase Gas Insulated Busduct

Series of Integers in Arithmetic Progression with a Common Property of Two Parts of Equal Sums

Keywords- Metal Oxide Surge Arrester, Model, Transient, Laboratory Experiment, Simulation.

SIMULATION OF THE POTENTIAL AND ELECTRIC FIELD DISTRIBUTION ON HIGH VOLTAGE INSULATOR USING THE FINITE ELEMENT METHOD

Evaluation of Capacitance in Motor Circuit Analysis Findings. Howard W Penrose, Ph.D., CMRP President, SUCCESS by DESIGN

A Novel Method to Integrate Thermal and Electrical Stress in HVDC Cable

UNCERTAINTIES IN THE APPLICATION OF ATMOSPHERIC AND ALTITUDE CORRECTIONS AS RECOMMENDED IN IEC STANDARDS

Study of Transient Behaviour of the Capacitor Voltage Transformer

Power System Research Group Electrical Engineering Dept., University of Saskatchewan Saskatoon, Canada


Some Aspects of Stress Distribution and Effect of Voids Having Different Gases in MV Power Cables

A New Model Reference Adaptive Formulation to Estimate Stator Resistance in Field Oriented Induction Motor Drive

The Effect of Harmonic Distortion on a Three phase Transformer Losses

Optimal Placement of Line Surge Arresters Based on Predictive Risk Framework Using Spatiotemporally Correlated Big Data

Optimal Performance Enhancement of Capacitor in Radial Distribution System Using Fuzzy and HSA

Transcription:

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn 2278-1676,p-ISSN 2320-3331, Volume 9, Issue 2 Ver. II (Mar Apr. 2014), PP 12-16 Modeling of Polluted High Voltage Insulators Omkar Singh 1, Rishabh Kushwaha 2 1-2 Department of Electrical Engineering Indian Institute of Technology (BHU), Varanasi, India Abstract High voltage insulators play a very important role in the transmission of power from generation to the consumer end, and in protecting the supporting towers from the high voltage lines as well as it also prevents the flashover due to the sudden rise of voltage and due to other causal factors. In this paper we have analyzed the effects of pollution on the insulator on the critical flashover voltage. Particularly, we have achieved our result by energy analysis of the insulator and the line supplying the energy. Some modification as per the requirement is done from the account of the value of constants such as A the arc constant n the arc index and K a constant multiplied before R p the resistance of the polluted layer. Overall a new equation of flashover voltage is achieved which differs from the model [1] by some factor i.e., constant. Keywords Flashover voltage, Arc constant, Arc index, ESDD (equivalent salt deposition density) I. Introduction Modeling of polluted insulators for the determination of flashover voltages prior the insulator failure is used in the transmission line application. The modeling is not done using any type of experiments on the insulators. It is the theoretical analysis of the various research papers published on the very same subject. In the development of this paper we have incorporated some of the ideas and explanation of the previous theories and equations with modification to reach the higher accuracy. The study of different type of insulators is done w.r.t their geometrical structures, as it is going to play a key role in the determination of the flashover voltages. In the modern days transmission system the flashover of the insulators is common, so this requires a great concern over the subject. In this paper the various equations of V the flashover voltage is compared with the approximate mathematical equation of the same, which is obtained using numerical method of approximation. And certain new variables are added to the final expression for the flashover voltage V. the model of Ghosh & Chatterji[1], Topalis[2], Gorur[3], Dhabhi M[4] have been compared with the approximate mathematical model and some important conclusions have been obtained. II. Details of proposed model The development of models for the flashover of polluted insulators which could take into account the real experimental conditions is not an easy task because of the complexity of the phenomena which can occur (Rizk 1981). Indeed, the non-uniformity of the polluted distribution due to the non-uniformity of deposits, wetting and drying leads to the appearance of multiple dry bands and then to multiple arcs. Nevertheless, many attempts have been made to generate models allowing one to predict roughly the critical characteristics of the polluted insulators (the flashover voltage, critical length and leakage current). For that purpose, the assumptions that there is a single dominant arc, a uniform pollution distribution and uniform wetting have been made. So, the arc is assumed to move only on the surface of the insulator. In the following model, we will consider similar assumptions. fig.1 By energy analysis of the circuit diagram i.e., power supplied before leakage current came into effect is equal to the power at the present condition. 12 Page

( ( )) (1) where x is the length of the arc, L is the leakage distance of the insulator and I is the leakage current. The resistance Ra per unit length of the arc(ω/cm) is defined as follows ( ) Where A and n are the arc constant and Rp, per unit length of the pollution layer(ω/cm) is where Deq is the equivalent diameter of the polluted insulator and σ is the surface conductivity, which is dependent on the equivalent salt deposit density C (ESDD), by σ= (369.05. C +0.42) where C is expressed in mg/cm 2.The equivalent diameter Deq of the insulator is given by Where F is the form factor of the insulator which is given by F = ( ) By solving (1) we get a quadratic equation in variable V, which can be solved easily to get the critical voltage. By solving we get the following result, ( ( )) (2) Before finding the roots of the equation, we are more concerned about the discriminant of the quadratic equation which is given by, (( ( )) ) (( ( )) ) ( ( ( )) ) By considering first three term of the binomial expansion and putting the corresponding value of discriminant in the solution of quadratic equation,, we get that ( ) (2) Where K = R p (L-x) + R a x When differentiating the above equation with respect to x and equating to zero, we obtain the critical current I I = (A/(Rp)) (1/n+1) (3) On the other hand, by differentiating equation ( ) ( ) [ ] (4) and by combining equations (3) and (4), we obtain the critical arc length x c as x c = [1 - ( ) ] (5) The plot of suggested model VS various other model are shown as below with respect to I and setting it equal to zero, we obtain fig.2 13 Page

fig.3 fig.4 As for as the fig.3 and 4 are concerned, they show the different aspects of studies that can be done on the particular equation which we have got. Our model as shown in the diagram lies always above the plot of Dhabi s model for the same parameters. From fig.3 the important thing which can be noted down is that there is a considerable gap between the two plots, as our plot is considerably lower than the other model with which it is compared. Which gives us a great advantage in modelling of the insulator for the case of high voltage application. As low value of flashover voltage is achieved for same value of arc constant this implies that where other model was giving higher value of flashover voltage, our model suffice with the experimental one and it is quite accurate with some level of tolerance From fig.4, it is observed that there is an appreciable amount of similarity still our plot is below the plot of the other model. Which signifies that the two models have the same sort of reasoning and logic but addition or removal of some parameter in the final flashover equation gives birth to a brand new equation. The advantage of the model deduced from the particular study is that, if the insulator is modelled according to our model the flashover voltage will be reduced to a greater margin. The flashover of the polluted insulator occurring at voltages lower than that suggested by earlier paper given in the references shows that there is flashover at those voltages[1],[2],[3] but it occurs below those voltages i.e., at the voltage approximately near to that suggested by this model. The above discussion was based on the plots as shown in the fig.2, fig.3and fig.4. III. Absolute study The following equation of flashover voltage as obtained- [ { ( ) } ( ) ] (6) And the three different plots explain this.. 14 Page

From the equation perspective the additional term containing C is major distinguishing factor as well as it brings accuracy as it reduces the tolerance level by certain percentage.the equation is almost similar to the previous equations as obtained by earlier researchers. By neglecting KC/2 term in equation-(2), as KC/r<<<1, we get our flashover equation as given below [ ] (7) Which shows that it is a function of Rp, which is obviously nonlinear. It depends on the value of n. As the value of n increases, the variation of flashover with R p tends to linearize itself. As n tends to infinity, flashover is proportional to R p. Most of the work on pollution flashover of insulators have used constant values of A and n for different atmosphere, assuming the arc to glide through either steam (A = 530, n = 0.24) or water vapor ( A = 63, n = 0.76).Alston [5] recommended that a combination A = 530 and n = 0.24 can yield good results for most problems. But there is still no consensus as to what values of A and n should be used in case of different polluted atmosphere. In fact, the optimal combination of A and n may be dependent on the chemical nature of the pollutants. In this model we have have used different values of A and n representing different electrolyte. Different sets of A and n in the following table represent NACl, CaCl 2 and FeCl 3 respectively. IV. Comparison of modelled output with experimental result TABLE 1 Showing the Critical Flashover Voltage by the present model and Practical value of it. R p (KΩ/cm) in L(cm) A n V model in KV 10 8 360 0.59 9.51 11 15 5 360 0.59 7.17 8 10 12 461 0.42 12.50 14 15 8 461 0.42 9.61 11 10 5 270 0.66 6.07 7 21.6 8 270 0.66 11.03 12 V(exp) KV From the Table 1, it can be seen that for values greater than 10, the error is quite high(in between 10-15%) but for the values less than 10, error is less than 7%.So we can say that this model can be used for the insulator with high contamination level. This model is based on an energy balance, an equivalent electrical circuit and the physical characteristics of the arc. The results given by the model that we elaborated are in good accordance with those obtained using the known empirical relations, especially insofar as the critical current and voltage are concerned. V. Conclusion The deficiency of applying the classical equation for the determination of critical flashover voltage of polluted insulators has been overcome by the selection of appropriate arc constants A and n for different chemical composition of the pollutants. The proposed mathematical model V = f (R p, L,A, n) thus takes into account the effect of change in the chemical nature of the pollutants under ac voltage application to predict accurately the flashover voltage. The computed results closely follow the experimental values. The model is validated against experimental and theoretical data of other researchers, and is observed to be good in predicting both critical V and I of practical insulators of a variety of geometries. Acknowledgements The present paper wouldn t be completed without the help and specified direction of our respected Professor Ravi S. Gorayan of Department of Electrical Engineering Indian Institute of Technology (BHU), Varanasi. We are thankful and are highly obliged to him. Moreover we are thankful to our mutual support without which the paper wouldn t be completed. Finally the advises of our seniors was also contributing, so we thank to them with the bottom of our heart. References [1] Polluted Insulator Flashover Model for ac Voltage P. S. Ghosh and N. Chatterjee, IEEE Transactions on Dielectrics and Electrical Insulation Vol. 2 No. 1, February 1995. [2] Dielectric behaviour of polluted porcelain insulators by F.V.Topalis, I.F.Gonos and I.A.Stathopulos. [3] Gorur, R. S., & Olsen, R. (2006). Prediction of flashover voltage of insulators using low voltage surface resistance measurement. Power System Engineering Research Center, Final Project Report, Arizona State University. 15 Page

[4] A new proposal model for flashover of polluted insulators by N Dhahbi-Megriche, A Beroual and L Krahenbuhl J. Phys. D Appl. Phys. 30 (1997) 889 894. [5] Alston, L. L., & Zoledziowski, S. (1963). Growth of discharges on polluted insulation.proceedings of the IEEE, 110(7), 1260 1266. [6] Suflis, S. A., Gonos, I. F., Topalis, F. V., & Stathopulos, I. A. (2003). Study of the dielectric behaviour of non-uniformly polluted insulators. In XIIIth international symposium on HV engineering, Netherlands. [7] Singer, H "Present and Future Topics of HV Field Calculation and Measurement, Proceedings of the 9 th International Conference on High Voltage Engineering, (Graz University of Technology), September 1995, pp. 9008-(1-4). [8] A. H. Rahal and C. Huraux, Flashover Mechanism of HV Insulator, IEEE Trans. PAS, Vol. 98, No. 6, pp. 2223-2231, Nov./dec. 1979. [9] The Electric Field Of Insulators WL Vosloo and JP Holtzhausen, Eskom / University of Stellenbosch, South Africa [10] Boheme H and Obenaus F 1966 Pollution flashover tests on insulators in the laboratory and in systems and the model concept of creepage path flashover, Cigr e, paper 407. [11] Kimoto, I., Fujimura, T., & Naito, K. (1973). Performance of insulators for direct current transmission line under polluted condition. IEEE Transactions on PAS, 92,943 949. [12] Sundararajan R, Sadhureddy N R and Gorur R S 1995 Computer aided design of porcelain insulators under polluted condition IEEE Trans. Dielectrics Electric Insulator. 2 121 7. [13] Wilkins, R. (1969). Flashover voltage of high voltage insulators with uniform surface pollution films. Proceedings of the IEEE, 116, 457 465. [14] Dhahbi-Megriche, N., & Beroual, A. (2000). Flashover dynamic model of polluted insulators under ac voltage. IEEE Transactions on Dielectrics and Electrical Insulation, 7(2), 283 289. [15] Wilkins R and Albaghdadi AJ 1971 Arc propagation along an electrolyte surface Proc. IEE 118 1886 92 [16] Gencoglu, M. T., & Cebeci, M. (2008). Computation of AC flashover voltages of polluted HV insulators using a dynamic arc model. European Transactions on Electrical Power, doi10.1002/etep.249. [17] P. S. Ghosh, S. Chakravorti and N. Chatterjee, Pollution Flashover of Electrolytic Surface under Power Frequency High Voltages, IE (India), Journal-EL, pp. 180-184, 1992. [18] Phillips, A.J. et al "Water Drop Corona on Full-Scale 500 kv Non-Ceramic Insulators ", IEEE Transactions on Power Delivery, Vol. 14, No. 1, January 1999, pp. 258-265. 16 Page