RESPONSE CALCULATIONS OF THE CdZnTe DETECTOR USING EGS4. James C. Liu, W. R. Nelson and R. Seefred

Similar documents
MEASURE SYNCHROTRON RADIATION AT PEP-II? y. W. R. Nelson. Stanford Linear Accelerator Center. Stanford University, Stanford, CA 94309

Development of Gamma-ray Monitor using CdZnTe Semiconductor Detector

In order to get the energy response of the CZT detector, the measurements were done using the mono-energetic X-ray beam sources from 10 to 40 kev and

Efficiency and Attenuation in CdTe Detectors

(a) Mono-absorber. (b) 4-segmented absorbers. (c) 64-segmented absorbers

Measurement of material uniformity using 3-D position sensitive CdZnTe gamma-ray spectrometers

Recent Activities on Neutron Standardization at the Electrotechnical Laboratory

2 Improvements of Programs 2.1 L-X ray Energy dependent L subshell cross sections In 1996 version of L-X ray calculation [5], the ratio of L sub

Since the beam from the JNC linac is a very high current, low energy beam, energy loss induced in the material irradiated by the beam becomes very lar

7. a XV-2 high spatial resolution lm detector (Kodak). Important parameters of these detectors are given in Table1. The ionization chambers and the di

EE 5344 Introduction to MEMS CHAPTER 5 Radiation Sensors

Comparison of the Photo-peak Efficiencies between the Experimental Data of 137 Cs Radioactive Source with Monte Carlo (MC) Simulation Data

Semiconductor Detectors

EEE4106Z Radiation Interactions & Detection

X-Ray Spectrum Generation for a Multiphase Flow Meter

Scintillation Detector

Semiconductor X-Ray Detectors. Tobias Eggert Ketek GmbH

- CdZnTe. À.À. Çàõàð åíêî, À.À. Âåðåâêèí... Ìîäåëèðîâàíèå ôóíêöèè îòêëèêà... [1, 2]. [1 4]. (, 241 Am, 137 Cs, 60 Co)., [5]. CdZnTe (, 661,67, CdZnTe

Radiation Protection Dosimetry (2006), Vol. 118, No. 3, pp Advance Access publication 6 October 2005

Estimate of Large CZT Detector Absolute Efficiency

POSITRON AND POSITRONIUM INTERACTIONS WITH CONDENSED MATTER. Paul Coleman University of Bath

Problem P7. Stéphanie Ménard. Dosimetry Department Fontenay-aux FRANCE IRSN QUADOS IRSN

DETECTORS. I. Charged Particle Detectors

Photon and primary electron arithmetics in photoconductors for digital mammography: Monte Carlo simulation studies

Comparative Analysis of Nuclear Cross Sections in Monte Carlo Methods for Medical Physics Applications

Development of semiconductor imaging detectors for a Si/CdTe Compton camera

Development and characterization of 3D semiconductor X-rays detectors for medical imaging

A NEW TECHNIQUE FOR STUDYING THE FANO FACTOR AND THE MEAN ENERGY PER ION PAIR IN COUNTING GASES

The Compton Effect. Martha Buckley MIT Department of Physics, Cambridge, MA (Dated: November 26, 2002)

PHYS 3650L - Modern Physics Laboratory

Geant4 Monte Carlo code application in photon interaction parameter of composite materials and comparison with XCOM and experimental data

Trace Element Analysis of Geological, Biological & Environmental Materials By Neutron Activation Analysis: An Exposure

THE spectroscopic performance of large volume CdZnTe

PERFORMANCE IMPROVEMENT OF CZT DETECTORS BY LINE ELECTRODE GEOMETRY

CHARACTERISTICS OF DEGRADED ELECTRON BEAMS PRODUCED BY NOVAC7 IORT ACCELERATOR

Particle Energy Loss in Matter

SIMPLE USE OF EGS4 BY EXCEL MACRO FILE

Application Note ANCZT-2 Rev. 3 Charge Trapping in XR-100T-CdTe and -CZT Detectors

MEASUREMENT OF DIAGNOSTIC X-RAY SPECTRA USING CdZnTe DETECTOR

SUPPLEMENTARY INFORMATION

Final report on DOE project number DE-FG07-99ID High Pressure Xenon Gamma-Ray Spectrometers for Field Use

Applied Nuclear Physics (Fall 2006) Lecture 21 (11/29/06) Detection of Nuclear Radiation: Pulse Height Spectra

Positron Annihilation Spectroscopy

Drift plane. substrate (20ÉIm polyimide) 200ÉIm. Back strip (180ÉIm width) Base (Ceramic) Anode strip (10ÉIm width) Cathode strip (100ÉIm width)

The GEANT Low Energy Compton Scattering (GLECS) Package for use in Simulating Advanced Compton Telescopes

New trends in CdTe detectors for X and γ-ray applications

Stability and Characteristics of Large CZT Coplanar Electrode Detectors

THE COMPTON EFFECT Last Revised: January 5, 2007

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

Radiation Detection for the Beta- Delayed Alpha and Gamma Decay of 20 Na. Ellen Simmons

SENSITIVITY ANALYSIS TO EVALUATE THE TRANSPORT PROPERTIES OF CdZnTe DETECTORS USING ALPHA PARTICLES AND LOW-ENERGY GAMMA-RAYS

DEVELOPMENT OF A NEW POSITRON LIFETIME SPECTROSCOPY TECHNIQUE FOR DEFECT CHARACTERIZATION IN THICK MATERIALS

Development of a Dosimetric System using Spectrometric Technique suitable for Operational Radiation Dose Measurements and Evaluation

Response Function of the BGO and NaI(Tl) Detectors Using Monte Carlo Simulations

Radiation Detection and Measurement

III. Energy Deposition in the Detector and Spectrum Formation

Advantages / Disadvantages of semiconductor detectors

arxiv:astro-ph/ v1 6 Mar 2001

Germanium Detectors. Germanium, a special material. Detectors, big is beautiful. Operational features. Applications. Iris Abt

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Chapter 4 Scintillation Detectors

Gamma Spectroscopy. References: Objectives:

Introduction into Positron Annihilation

Polarised Geant4 Applications at the ILC

Gamma and X-Ray Detection

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March-2014 ISSN

GAMMA RAY SPECTROSCOPY

Hard X- and g-ray measurements with a large volume coplanar grid CdZnTe detector

Particle Energy Loss in Matter

Count. Count. 200mm. PMT scintillation. PMT flourescence. PMT fluorescence. PMT fluorescence. PMT fluorescence. 50mm. 42mm

ESTIMATION OF 90 SCATTERING COEFFICIENT IN THE SHIELDING CALCULATION OF DIAGNOSTIC X-RAY EQUIPMENT

Lecture notes on Chapter 13: Electron Monte Carlo Simulation. Nuclear Engineering and Radiological Sciences NERS 544: Lecture 13, Slide # 1:13.

MEASUREMENT AND DETECTION OF RADIATION

Copyright 2008, University of Chicago, Department of Physics. Experiment VI. Gamma Ray Spectroscopy

Monte Carlo radiation transport codes

Analysis of γ spectrum

Development of a Spectral Model Based on Charge Transport for the Swift/BAT 32K CdZnTe Detector Array

Monte Carlo Simulator to Study High Mass X-ray Binary System

Gamma Radiation Absorption Characteristics of Concrete with Components of Different Type Materials

Effects of Etching and Chemo-Mechanical Polishing on the Electrical Properties of CdZnTe Nuclear Detectors

Results of a Si/CdTe Compton Telescope

Radiation Transport Calculations by a Monte Carlo Method. Hideo Hirayama and Yoshihito Namito KEK, High Energy Accelerator Research Organization

MONTE-CARLO MODELING OF SILICON X-RAY DETECTORS

Radioactivity. Lecture 6 Detectors and Instrumentation

Characterization of the 3 MeV Neutron Field for the Monoenergetic Fast Neutron Fluence Standard at the National Metrology Institute of Japan

Detection and measurement of gamma-radiation by gammaspectroscopy

PHOTON-NEUTRON SHIELDING CALCULATIONS FOR ELECTRON STORAGE RINGS. J. C. Liu, W. R. Nelson and K. R. Kase ~~~_

Jazan University College of Science Physics Department. Lab Manual. Nuclear Physics (2) 462 Phys. 8 th Level. Academic Year: 1439/1440

ORTEC AN34 Experiment 10 Compton Scattering

On the energy deposition by electrons in air and the accurate determination of the air-fluorescence yield

Quantitative Assessment of Scattering Contributions in MeV-Industrial X-ray Computed Tomography

Simulating Gamma-Ray Telescopes in Space Radiation Environments with Geant4: Detector Activation

Alpha-Gamma discrimination by Pulse Shape in LaBr 3 :Ce and LaCl 3 :Ce

Maximum-Likelihood Deconvolution in the Spatial and Spatial-Energy Domain for Events With Any Number of Interactions

Monte Carlo radiation transport codes

Chapiter VII: Ionization chamber

Chemical Engineering 412

physics/ Sep 1997

INTERACTIONS OF RADIATION WITH MATTER

A Measurement of Monoenergetic Neutrons from 9 Be(p,n) 9 B

Transcription:

SLAC-PUB-8606 (September 5, 2000) RESPONSE CALCULATIONS OF THE CdZnTe DETECTOR USING EGS4 James C. Liu, W. R. Nelson and R. Seefred Stanford Linear Accelerator Center, MS 48, P. O. Box 4349, Stanford, CA 94309, USA Presenter s e-mail: james@slac.stanford.edu ABSTRACT The spectral response of a CdZnTe semiconductor detector has been calculated with the EGS4 Code System. The latest low-energy photon production and transport routines developed at KEK, which consider the K and L shell fluorescent photon production in compounds, bound Compton scattering, Doppler broadening, etc., were included in the EGS4 code. The calculations of the CdZnTe detector also took into account the collection efficiency of the produced electron-hole pairs (described by Hecht equation) and the modification on spectral peaks due to both the Fano factor and electronic-noise broadening. The calculated results are compared with measurements made with encapsulated 241 Am and 137 Cs disk sources. It was found that, by trying various mobility-lifetime values for holes, the calculated spectral response still did not have perfect agreement with measurements. Work supported by the US Department of Energy under contract DE-AC-03-76SF00515 Submitted to the 2 nd International Workshop on EGS4 KEK, Tsukuba, Japan, August 8-10, 2000 INTRODUCTION In a previous study [1], the EGS4 Code System [2] was used to calculate the spectral response for a CdZnTe detector (called CZT hereafter) that was used to measure the synchrotron radiation leakage spectra in a PEP-II accelerator radiation environment. In that paper, minor disagreements were found when the EGS4-calculated photon spectra were compared with measurements made using encapsulated 241 Am, 133 Ba and 109 Cd disk sources. In the previous study, the following processes were standard with EGS4: photoelectric effect (with angular sampling from the Sauter formula), coherent (Rayleigh) and Compton scattering (unbound), discrete Moller and Bhabha interactions, positron annihilation (in-flight and at-rest), continuous energy loss, Moliere multiple scattering applied to charged-particle tracks, and pair production/bremsstrahlung (with angular sampling). In addition to these processes, the simulations also specifically took into account: 1) production of K-shell fluorescence from a CZT mixture, using an improvement to a method developed for EGS4 by Del Guerra et al [3], 2) collection of electron-hole pairs (the signal) using the Hecht equation [4], 3) narrowing of the signal by considering Fano factor and broadening of the signal due to electronic-noise. Recently Hirayama and Namito at KEK have developed routines to treat low-energy photon production and transport in materials [5,6]. The routines mainly consider bound Compton scattering, Doppler broadening, and the K and L shell fluorescent photon production in elements, as well as in compounds. Therefore, in this study we incorporated the KEK routines into the EGS4 Code System in order to compare with the previous study. In addition, to further resolve the above-mentioned discrepancy between EGS4 calculations and measurements, this time we have studied in depth the calculation algorithm of spectral response, particularly by using various mobility-lifetime values in the Hecht equation. Additional photon spectra measurements using 241 Am and 137 Cs disk sources were also made to compare with EGS4 calculations.

EGS4 CALCULATIONS Detector Material and Energy Cutoffs The CZT detector was made by ev Products, Inc. (model ev-180-3-3-2-s; 375 Saxon Blvd., Saxonburg, PA 16056, USA). The CZT material data was created with the MIXT option of PEGS4 using a density of 5.86 g/cm 3 and RHOZ values of 50.58, 3.27 and 63.80 for Cd, Zn and Te, respectively (corresponding to atomic percentages of 45, 5 and 50%). The PEGS4 energy limits were chosen to be (AP=0.001, UP=10.0) and (AE=0.521, UE=10.511) MeV for photons and electrons, respectively. In addition to turning on the Rayleigh scattering option (IRAYL=1) and the option of radiative stopping powers compliant with ICRU-37 (IAPRIM=1), all the KEK low-energy photon options (IXRAY=1, IBOUND=1, INCOH=1, ICPROF=-3, IMPACT=1) were turned on. The photon transport cutoff PCUT was set at 0.001 MeV. The electron cutoff energy ECUT was set at 1.511 MeV, forcing the kinetic energy of the electrons to be deposited at their points of creation, except for 137 Cs (ECUT was then 0.561 MeV). The rationalization for doing this is based on the fact that the ranges of secondary electrons from all radioisotopic source photons (except 137 Cs) in CZT are much smaller than the dimensions of the CZT crystal. In any case, a check was made with ECUT=AE=0.521 MeV (i.e., 10 kev kinetic energy) and the results were essentially the same as with higher ECUT values. It was also found that the use of PRESTA [7] did not change the results. Measurements and EGS4 Geometry The measurement and the corresponding EGS4 geometry in this study (see Figure 1) were similar to that in the previous study. X-ray photographs showed that the CZT crystal (3x3 mm 2 and 2 mm thick), mounted inside a BNC-type connector, is 0.575 cm from the 0.25-mm-thick beryllium window of CZT detector. An aluminum cylinder of 0.45 cm inner radius and 0.1 cm thickness surrounds the crystal. Our EGS4 user code utilized a generalized cylinder/azimuthal plane/slab geometry package (ucrtz.mortran and ucrtz.data), with the cylindrical radius of the CZT crystal chosen to be 0.17 cm to provide an equivalent cross-sectional area of 9 mm 2. The 241 Am or 137 Cs disk source was positioned at 10 cm away from the beryllium window. The radiation sources were sealed in plastic discs, 25 mm in diameter and 5 mm thick (the source was actually about 1 mm deep). The input gamma and X-ray energies, and their corresponding intensities, were taken from ICRP Publication 38 [8] for each of the three sources: 241 Am, 133 Ba and 109 Cd. A single energy of 662 kev was used for 137 Cs source. Energy sampling was done by means of a simple cumulative distribution table. Due to the large distance, a point source and a monodirectional photon beam toward the front face of CZT detector were assumed in the calculations. To reduce electronic noises, the BNC-CZT unit was attached directly to a matching connector on an inverting low-noise, charge-sensitive preamplifier (ev Products, model ev-550). A bias voltage of +200 V (+400 V for 137 Cs) was supplied to the detector through the preamplifier, with the front surface of the crystal negatively biased in order to maximize the collection of holes. Output pulses were processed with a pulse-shaping amplifier having a 0.5 µsec shaping time and sent to a PC-based multi-channel analyzer. Scoring of Electron-Hole Pair Collection Electron-hole pairs are created whenever energy is deposited in a semiconductor. The average energy required to create an electron-hole pair is denoted as the W value (we used W = 4.6 ev for the CdZnTe). The output pulse is proportional to the charge that is collected which, in turn, is controlled primarily by the mobility-lifetime products, µ e τ e and µ h τ h (units: cm 2 /V), for electrons and holes, respectively. The mobility of charge carriers in CdZnTe is much smaller than in Si and Ge detectors and, thus, the charge carriers are easily trapped in the crystal while they drift to the electrodes. The charge-collection efficiency is defined as the ratio of the number of charge carriers collected at the electrodes to the total number of carriers generated by the radiation energy deposition. If the effect of detrapping is neglected, the charge-collection efficiency η(z) for charge carriers at depth z in a semiconductor crystal of thickness d (cm) can be determined by means of the Hecht equation [3]: η(z) = (λ e /d)(1-e -(d-z)/λe ) + (λ h /d)(1-e -z/λh ) (1) where λ e = µ e τ e E and λ h = µ h τ h E are the mean free paths (units: cm) for electrons and holes, respectively, z is the depth into the crystal from the negatively-biased (voltage V in volts) front surface and E is the electric field strength (E=V/d) in the detector.

Typical mobility-lifetime values we used in the Hecht equation were µ e τ e = 7x10-3 cm 2 /V and µ h τ h = 5x10-5 cm 2 /V. With a high voltage of 200 V and a detector thickness of d = 0.2 cm, the λ e is 7 cm and λ h is 0.05 cm. Therefore, it is clear that holes can be easily trapped particularly when they are produced at depths far away from the negatively-biased electrode. Since the low-energy photons from 241 Am deposit energy primarily near the front face while the 662-keV photons of 137 Cs deposit energy uniformly along the depth, the charge collection effect is more pronounced for 137 Cs photons, which also makes it a better source to examine the effect of mobility-lifetime value. Fano Factor and Electronic Noise Broadening To compare the EGS4-calculated spectra with experimental results, the Fano factor and the peak broadening due to electronic noise, etc. were also considered [9]. Namely, for each incident photon, a running sum of the total number of electron-hole pairs that are created at the EDEP sites in the detector is kept with each contribution multiplied by the corresponding charge-collection efficiency determined by the Hecht equation. To be more specific, we first determine the charge collected (unstraggled) per photon event N: N = Σ η(z) Edep (z) / W, (2) where Edep(z) is the energy deposited at depth z from the front surface of the crystal. The total standard deviation is then determined from: σ 2 = fn + σ enc 2, (3) where f is the Fano factor for CZT and σ enc is a standard deviation to account for the equivalent noise charge of the electronics [9]. We used values for W, f and σ enc similar to those reported by Bencivelli et al. [10] for Cd-Te; f=0.14 and σ enc =150 e-h pairs. Finally, the straggled (broadened) charge that is collected, Ns, is statistically determined by sampling from a Gaussian peak, centered about N with σ. The corresponding energy, Es = WNs, is then histogrammed for each incident photon event for comparison with experiment. RESULTS Figure 2 shows that 241 Am spectra calculated using EGS4 with the latest KEK low-energy photon production and transport routines and that with Nelson s approach for compounds (the previous study) have perfect agreement for the major peaks above 10 kev. Similar comparisons for 133 Ba and 109 Cd also gave good agreement. Hereafter throughout the paper the results will be those calculated using the EGS4 with the KEK routines. Figure 3 indicates that, as expected, the choice of different values for parameters W, Fano factor f, and density ρ of CdZnTe did not affect the spectrum much. The measured photon spectrum is shown in Figure 4 for 241 Am (+200 V and 0.5 µs) and Figure 5 for 137 Cs (+400 V and 0.5 µs). To illustrate our response calculation algorithm, Figure 6 shows the 241 Am photon spectrum at different stages of CZT spectral response calculations. The top figure is the energy deposition spectrum, the middle one is the spectrum taking into account the charge collection and peak modification from Fano factor and electronic noise (but W value is not included yet), and the bottom one is the final photon spectrum with the W value included. To examine the Hecht equation and its parameters, we first studied the effect of hole s mobility-lifetime value. Figure 7 shows three 241 Am photon spectra calculated using three values of µ h τ h while Figure 8 gives three corresponding 137 Cs photon spectra. After comparing these calculated spectra with the measurements in Figure 4 and 5, it is clear that a µ h τ h value of 5x10-5 cm 2 /V gave better (not perfect yet) agreements for both cases of 241 Am and 137 Cs. The results using the other two extreme values (3x10-4 and 7x10-6 ) are not correct. This seems to be consistent with the µ h τ h values stated in [11,12]. Setting the µ h τ h value at 5x10-5 cm 2 /V, Figure 9 shows the 241 Am photon spectra calculated with two different values of µ e τ e (1x10-3 and 7x10-3 cm 2 /V) and σ enc (150 and 200 e-h). A µ e τ e value of 7x10-3 seems to be correct and the value of 1x10-3 gave a wrong peak position result. The choice of σ enc at 150 and 200 e-h does not affect the results. Similar conclusions were obtained for the case of 137 Cs source.

CONCLUSIONS In this study we have used EGS4 to simulate the response of a CZT crystal, mounted within a BNC connector, taking into account the incomplete collection of charge by means of the Hecht equation. We have found perfect agreement for the calculated spectra between the EGS4 with the latest KEK low-energy photon routines and the standard EGS4 with Nelson s approach for compounds. This study has also shown that all of the photo and escape peaks appear at the correct energies, but the peak widths are not in perfect agreement with experiment. The most important parameter, mobility-lifetime for hole µ h τ h, should be around 5x10-5 cm 2 /V, while the mobilitylifetime for electron µ e τ e, should be about 7x10-3 cm 2 /V. The other parameters do not affect the spectra as much as the mobility-lifetime value. The remaining discrepancy may be due to that the Hecht model itself is too simple. REFERENCES 1. W. R. Nelson, T. Borak, R. Malchow, W. Toki and J. Kadyk, EGS4 calculations for a CdZnTe detector to measure synchrotron radiation at PEP-II, Proceedings of the First International Workshop on EGS4, KEK, Tsukuba, Japan, August 26-29, 1997. 2. W. R. Nelson, H. Hirayama and D. W. O. Rogers, The EGS4 Code System", SLAC Report 265, 1985. 3. A. Del Guerra, W. R. Nelson and P. Russo, A simple method to introduce K-Edge sampling for compounds in the code EGS4 for x-ray element analysis", Nucl. Instr. Meth. A306, p378, 1991 [Erattum: Nucl. Instr. Meth. A359 (1995) 637]. 4. G. Baldazzi, D. Bollini, F. Casali, P. Chirco, A. Donati, W. Dusi, G. Landini, M. Rossi and J. B. Stephen, Timing response of CdTe detectors", Nucl. Instr. Meth. A326, p319, 1993. 5. H. Hirayama and Y. Namito, Implementation of a general treatment of photoelectric-related phenomena for compounds or mixtures in EGS4, KEK Internal Report, In Preparation, 2000. 6. H. Hirayama and Y. Namito, LSCAT: low-energy photon-scattering expansion for the EGS4 code (inclusion of electron impact ionization), KEK Internal Report, In Preparation, 2000. 7. A. F. Bielajew and D. W. O. Rogers, PRESTA: The Parameter Reduced Electron Step Transport Algorithm for Electron Monte Carlo Transport", Nucl. Instr. Meth. B18, p165, 1987; also NRC-PIRS-0042, 1986. 8. Radioactive Transformations, Publication 38, International Commission of Radiological Protection, Annals of the ICRP 11-13, 1983. 9. W. R. Leo, Techniques for Nuclear and Particle Physics Experiments (Springer-Verlag, Second Edition, 1994; see Chapter 10. 10. W. Bencivelli, E. Bertolucci, U. Bottigli, A. Del Guerra, A. Messineo, W. R. Nelson, P. Randaccio, V. Rosso, P. Russo and A. Stefanini, Evaluation of elemental and compound semiconductors for x-ray digital radiography", Nucl. Instr. Meth. A310, p210, 1991. 11. H. Nishizawa, et al., Calculation of CdTe semiconductor detector response, Proceedings of the First International Workshop on EGS4, KEK, Tsukuba, Japan, August 26-29, 1997. 12. G. A. Johansen and E. Abro, A new CdZnTe detector system for low-energy gamma-ray measurement, Sensors and Actuators A54, p493-498, 1996.

R 0.55 I max = 3 0.45 2 Plastic 0.1 Air Be J max = 1 0.025 0.2 Al 8556A7 I = 1 γ 0.17 10.0 CZT 0.575 1.0 0 0.1 10.0 10.025 10.6 10.8 11.8 K = 1 2 3 4 5 6 K max Z All Units in cm Figure 1. Irradiation geometry for the CdZnTe detector using 241 Am and 137 Cs disk sources. 10 7 10 6 KEK Nelson 10 5 10 3 10 2 8556A1 0 20 40 60 80 Figure 2. Comparison of 241 Am spectra calculated with EGS4 using two different schemes; the latest KEK low-energy photon production and transport routines and Nelson s approach for compounds. 120 80 Curve W(eV) Fano ρ(gm/cm 3 ) Dash 5.0 0.20 5.78 Solid 4.6 0.14 5.86 40 8556A4 0 0 20 40 60 80 Figure 3. Comparison of 241 Am spectra calculated with EGS4 (with the KEK low-energy photon routines) using different values for parameters of W, Fano factor f, and density ρ of CdZnTe.

0.012 0.010 Counts (Arb.) 0.008 0.006 0.004 0.002 0.000 0 10 20 30 40 50 60 70 Photon Figure 4. 241 Am photon spectrum measured using CdZnTe detector (+200 V and 0.5 µs). 10 1 Fractional Counts 10 2 10 3 10 4 8556A14 0 200 400 Photon 600 Figure 5. 137 Cs photon spectrum measured using CdZnTe detector (+400 V and 0.5 µs).

10 8 50M Cases 10 6 10 2 10 0 0 20 40 60 80 8556A10 10 7 10 6 10 5 10 3 10 2 0 2 4 6 8 10 12 14 Number of e h Pairs (x10 3 ) 8556A9 10 7 10 6 10 5 10 3 10 2 0 10 20 30 40 50 60 70 80 8556A8 Figure 6. 241 Am photon spectrum at three stages of CdZnTe response calculation: energy deposition spectrum (top), electron-hole pair spectrum (middle), and photon spectrum (bottom).

1.2 3 x 10 4 5 x 10 5 7 x 10 6 x 10 6 0.8 0.4 0 8556A5 0 20 40 60 80 Figure 7. 241 Am photon spectrum calculated with EGS4 using three values of µ h τ h (units in cm 2 /V). 10 5 3x10 4 7x10 6 5x10 5 10 3 10 2 8556A15 0 200 400 600 Figure 8. 137 Cs photon spectrum calculated with EGS4 using three values of µ h τ h (units in cm 2 /V). (x ) 120 80 µτ e σ enc Curve (cm 2 /V) (e h) Dash 1x10 3 150 Solid 7x10 3 200 40 0 0 20 40 60 80 8556A16 Figure 9. 241 Am photon spectrum calculated with EGS4 using different values of µ e τ e and σ enc.