Mitigations to Flow Induced Vibration (FIV) in Control Valve Piping System using Visco-Elastic Dampers & Neoprene Pads

Similar documents
Fatigue Life Estimation of Piping System for Evaluation of Acoustically Induced Vibration (AIV)

API th Edition Ballot Item 6.5 Work Item 41 Flow Induced Vibration Guidance

THERMOWELL VIBRATION INVESTIGATION AND ANALYSIS

Analysis And Control Of Severe Vibration Of A Screw Compressor Outlet Piping System

MOOC QP Set 2 Principles of Vibration Control

Global J. of Mech., Engg. & Comp. Sciences, 2012: 2 (1)

Acoustic Resonance in Main Steam Line Side Branches

Centrifugal Compressor Root Cause Analysis. (Pulsation and Vibration Issues)

Effect of Angular movement of Lifting Arm on Natural Frequency of Container Lifting Mechanism using Finite Element Modal Analysis

Smallbore. Definition of a Cutoff Natural Frequency for. Jim McGhee, Xodus Group

Dynamic Analysis on Vibration Isolation of Hypersonic Vehicle Internal Systems

VIBRATION ANALYSIS OF E-GLASS FIBRE RESIN MONO LEAF SPRING USED IN LMV

Fatigue-Ratcheting Study of Pressurized Piping System under Seismic Load

DEVELOPMENT OF SEISMIC ISOLATION TABLE COMPOSED OF AN X-Y TABLE AND WIRE ROPE ISOLATORS

Sizing Thermowell according to ASME PTC 19.3

VIBRATION ENERGY FLOW IN WELDED CONNECTION OF PLATES. 1. Introduction

FLUID STRUCTURE INTERACTIONS PREAMBLE. There are two types of vibrations: resonance and instability.

93. Study on the vibration characteristics of structural of hydrocyclone based on fluid structure interaction

International Journal of Modern Trends in Engineering and Research e-issn No.: , Date: April, 2016

Chapter a. Spring constant, k : The change in the force per unit length change of the spring. b. Coefficient of subgrade reaction, k:

DSC HW 3: Assigned 6/25/11, Due 7/2/12 Page 1

STRUCTURAL ANALYSIS OF A WESTFALL 2800 MIXER, BETA = 0.8 GFS R1. By Kimbal A. Hall, PE. Submitted to: WESTFALL MANUFACTURING COMPANY

Numerical Investigation of Vortex Induced Vibration of Two Cylinders in Side by Side Arrangement

Experimental Study and Analysis of Flow Induced Vibration in a pipeline

Comptes Rendus Mecanique

VIBRATION ANALYSIS OF AN AUTOMOTIVE SILENCER

CFD DESIGN OF A GENERIC CONTROLLER FOR VORTEX-INDUCED RESONANCE


The Simulation of Dropped Objects on the Offshore Structure Liping SUN 1,a, Gang MA 1,b, Chunyong NIE 2,c, Zihan WANG 1,d

How to avoid pressure oscillations in district heating systems

Analysis of flow characteristics of a cam rotor pump

Noise and Vibration Analysis of a Heat Exchanger: a Case Study

Vibration Control Prof. Dr. S. P. Harsha Department of Mechanical & Industrial Engineering Indian Institute of Technology, Roorkee

Comparison between the visco-elastic dampers And Magnetorheological dampers and study the Effect of temperature on the damping properties

EVALUATING DYNAMIC STRESSES OF A PIPELINE

Wake Frequency Calculations Solid Drilled Thermowells

Proceedings of the ASME nd International Conference on Ocean, Offshore and Arctic Engineering OMAE2013 June 9-14, 2013, Nantes, France

Jumper Analysis with Interacting Internal Two-phase Flow

INTERNATIONAL OIML D 25 DOCUMENT. Vortex meters used in measuring systems for fluids ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

Class XI Physics Syllabus One Paper Three Hours Max Marks: 70

Hydraulic Design Of Polyethylene Pipes

Address for Correspondence

Hysteresis Modelling of an MR Damper Applied to Suspension System

Modal and Static Structural Analysis of Exhaust Collector Box for Compressor test facility

Applied Fluid Mechanics

Damping in dense gas acoustic structure interaction

Damping of materials and members in structures

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

ROLLER BEARING FAILURES IN REDUCTION GEAR CAUSED BY INADEQUATE DAMPING BY ELASTIC COUPLINGS FOR LOW ORDER EXCITATIONS

DELTA FLOWMETER FOR GAS SERVICE (INSERTION TYPE) MODEL VF SERIES

TitleOn the Design Wind Force of. Author(s) YOKOO, Yoshitsura; ISHIZAKI, Hatsuo.

Fluids. Fluids in Motion or Fluid Dynamics

THE EFFECT OF TWO PHASE (AIR-WATER) FLOW CHARACTERISTICS ON MOMENTUM FLUX DUE TO FLOW TURNING ELEMENTS AT ATMOSPHERIC CONDITIONS

FIV INFLUENCE BEND RADIUS ON MULTIPHASE FLOW INDUCED FORCES ON A BEND STRUCTURE

Study of the influence of the resonance changer on the longitudinal vibration of marine propulsion shafting system

Spacecraft Structures

OMAE FLUID-STRUCTURE INTERACTION MODELING OF SUBSEA JUMPER PIPE

TE 75R RESEARCH RUBBER FRICTION TEST MACHINE

Design Optimization for an Expansion Loop in Petrochemical Refinery

Appendix A Satellite Mechanical Loads

A Sample Durability Study of a Circuit Board under Random Vibration and Design Optimization

Testing Elastomers and Plastics for Marc Material Models

405 Compact Orifice Series and 1595 Conditioning Orifice Plate Flow Test Data Book and Flow Handbook

Random vibration analysis and fatigue life evaluation of auxiliary heater bracket

ABSTRACT I. INTRODUCTION

The Behaviour of Simple Non-Linear Tuned Mass Dampers

T1 T e c h n i c a l S e c t i o n

Finite Element Analysis of Piezoelectric Cantilever

Self-Excited Vibration in Hydraulic Ball Check Valve

Index. Branching device (see also Division of vibrational power), 42, 114

DEVELOPMENT OF ACTIVELY TUNED VIBRATION ABSORBER FOR WASHING MACHINE

VORTEX INDUCED VIBRATIONS

BEL Frahm Damper System

1. Introduction. 1.1 Overview of Study:

NORTH SEA FLOW MEASUREMENT WORKSHOP 2004 In. St Andrews, Scotland

Dynamics of Machinery

Analysis of Flow Regulating Pressure Valve by using Finite Element Analysis

HELMHOLTZ RESONATORS FOR DAMPING COMBUSTOR THERMOACOUSTICS

This document is a preview generated by EVS

Estimation of damping capacity of rubber vibration isolators under harmonic excitation

Answers to questions in each section should be tied together and handed in separately.

ISO INTERNATIONAL STANDARD. Acoustics Acoustic insulation for pipes, valves and flanges

Investigation of Cryogenic Cooling Systems Activated by Piezoelectric Elements

Turbulence Modeling Applied to Flow over a Hydraulic Ball Check Valve

A Guide to linear dynamic analysis with Damping

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

A modal approach for vibration analysis and condition monitoring of a centrifugal pump

STUDIES ON UNDERWATER VIBRATION ISOLATION MODULE

HVAC Clinic. Duct Design

FINAL DRAFT: October 25, 2010 API TECHNICAL REPORT FUEL GAS MEASUREMENT. FINAL DRAFT: October 25, 2010 Page 0

UNIVERSITY OF SASKATCHEWAN Department of Physics and Engineering Physics

FLOW IN PIPES. Mark J McCready University of Notre Dame July 24, chemeprof.com

Preliminary Examination - Dynamics

COMPARISON BETWEEN 2D AND 3D ANALYSES OF SEISMIC STABILITY OF DETACHED BLOCKS IN AN ARCH DAM

Vortex Induced Vibrations

WTS Table of contents. Layout

507F. Multi-Port Sanitary Ball Valve. Full Port ISO 5211 Mounting Pad. For Automated & Manual Service. Pharmaceutical. Bio-Technology.

Analysis and Optimization of Engine Mounting Bracket

Fundamentals of silencing and their practical application in screw compressor plants

ME3560 Tentative Schedule Spring 2019

Transcription:

IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 07 January 2017 ISSN (online): 2349-784X Mitigations to Flow Induced Vibration (FIV) in Control Valve Piping System using Visco-Elastic Dampers & Neoprene Pads Mr. Bhagwat B. Kedar Ms. Jayshri S. Gulave M. Tech. Student (CAD/CAM & Automation) M. E. Student (Heat Power) Department of Mechanical Engineering Department of Mechanical Engineering Veermata Jijabai Technological Institute Mumbai, India Matoshri College of Engineering & Research, Nashik, India Abstract The control valve piping is vibrating due to high flow rate and high velocity, also this line is running at different flow rate condition. The generic calculations based on Energy Institute Guidelines [1] indicate that the flow is Turbulent and Likelihood of Failure is more than one. This number is alarming and detailed analysis considering change in flow, pipe route, supports etc. is recommended to be performed. This Paper aims to study the 12-inch Control Valve Piping Vibrations observed at site due high flow rates and high velocity. and also attempts to find probable cause of the vibration and the solution to minimize these vibrations. Keywords: FIV, CAESAR II, LOF, Visco-Elastic Damper, Vibration Pads I. INTRODUCTION Pipe will exhibit a series of natural frequencies which depends on the distribution of mass and stiffness throughout the system, and the distribution are influenced pipe diameter, material properties, wall thickness, location of lumped masses (such as valves), pipe supports and also fluid density. Each natural frequency will have unique deflection shape associated with it, which is called mode shapes, which has the locations of zero motion (node) and maximum motion (Antinodes). The response of the pipe work to an applied excitation is dependent upon the relationship between the frequency of excitation and the system s natural frequencies. Vibration generated in the pipe work may lead to high cycle fatigue of components (such as Small bore connections) or the failure at welds in the main line itself. II. FLOW INDUCED VIBRATION Flow-induced vibration, or vortex shedding, is due to high flow velocities and High mass flow rates such as in a piping dead leg of a centrifugal compressor system. with certain flow conditions, piping systems will develop high levels of noise and vibration that can damage the pipes and related systems such as tube bundles, side cavities, and bluff or tapered bodies in flow streams. Pipe damage compromises plant safety, forces shutdowns, increases maintenance, and reduces efficiency and capacity. Fig. 1: Example of vortex shedding from an object in the flow stream. III. VISCO-ELASTIC DAMPER Viscoelastic dampers reduce vibrations by converting kinetic energy into heat thus damping the motion of the system. Damping, as a method to reduce unwanted vibrations, is most effective in cases where the vibratory system is excited with a frequency close to its natural frequency. [3] Viscoelastic dampers may be used to solve very different vibration problems. A typical example is the damping of operational vibrations in an industrial piping system e.g. in a power plant. Whenever the piping systems cannot be isolated from the source of vibration, damping might be an adequate measure to reduce the motion of the piping to an acceptable level. The Construction and mounting of the Visco-Elastic Damper is shown in Fig. 2. All rights reserved by www.ijste.org 40

Fig. 2: (a) Visco-Elastic Damper at site (b) Construction of Visco-Elastic Damper Top Connection plate Bottom connection plate Serial Number plate Position Indicator Housing Fluid Piston IV. CASE STUDY System Description The system consists of 12-inch control valve piping which is observed to be vibrating at site. Also this line is running at different flow rate condition. [5] The line serves between Potassium carbonate solutions to the rich solution flash tank. Points at which Amplitude of Vibration is noted in the System were noted as A, B, C, D, E, F, G, H, & I as shown in Fig. 3. Fig. 3: Typical System from Vibration Report Approach towards Solution Following approach has been applied to find most probable solution to Vibration problem in 12- inch control valve. A Qualitative Analysis has been carried out to identify the potential Excitation Mechanism that may exist. (LOW to HIGH). A Quantitative Analysis of an LOF score for each identified excitation mechanism from Qualitative Analysis and Periodic flow frequency calculation. Based on LOF score (0-1) Recommendation & corrective Actions have been recommended. Dynamic stress Analysis of the system using CAESAR-II to simulate analysis model with site observations. To propose corrective actions using results. All rights reserved by www.ijste.org 41

Input Data Mitigations to Flow Induced Vibration (FIV) in Control Valve Piping System using Visco-Elastic Dampers & Neoprene Pads Table - 1 Input Data Sr. No Input Unit Case 01 Max Flow Case 02 Max Flow Case 03 Max Flow 1 Fluid Density kg/ m 3 1169 1169 1169 2 Viscosity Pa-s 0.25 0.25 0.25 5 Operating Temperature 0 C 124 124 124 6 Upstream Pressure of the control valve Pa 1372931 211823.6 267721.5 7 Downstream Pressure of the control valve Pa 200546 197113.7 197113.7 8 Mass Flow Rate kg/sec 325.45 148.75 310.16 9 Pipe Size mm 323.85 323.85 323.85 10 Wall Thickness of Main Line mm 10.3124 10.3124 10.3124 11 Fluid Velocity m/sec 4.278 2.32 3.95 12 Maximum Span Length between supports on line of interest m 3.21 3.21 3.21 13 Speed of Sound in Fluid m/sec 2000 2000 2000 14 Length of Side branch m 3.21 3.21 3.21 Likelihood of Failure (LOF) Calculation Flow Induced Turbulence a) Step 1: Determine ρv 2 For single phase flow ρv 2 = (actual density) x (actual velocity) (1) Kinetic Energy =1169 4.278 2 Kinetic Energy =21934.201 kg/m-s 2 b) Step 2: Determine Fluid Viscosity Factor As the fluid in this example is gas the fluid viscosity factor (FVF) must be calculated; this requires the gas dynamic viscosity (µ gas). Fluid Viscosity Factor (FVF) = 0.25 µ 1 10 3 (2) Fluid Viscosity Factor (FVF) = 1 10 3 Fluid Viscosity Factor (FVF) = 15.82 c) Step 3: Determine Support Arrangement The pipe support arrangement must now be determined. This requires the maximum span lengths between supports to be identified and compared with the criteria. In all cases the support classification is Stiff (14-16Hz). d) Step 4: Determine Flow Induced Vibration Factor Fv Flow Induced Vibration Factor (Fv) = 686540 ( 323.8 10.35 ) 0.80 Flow Induced Vibration Factor (Fv) = 44183 e) Step 5: Calculation of Likelihood of Failure (LOF) Finally, the LOF for each line is calculated using: Flow Induced Vibration Factor (Fv) = α ( D ext T )β (3) Likelihood of Failure (LOF) = ρv2 FVF (4) Fv Likelihood of Failure (LOF) = 21394.20 44183 15.82 Likelihood of Failure (LOF) = 7.661 As the value of Likelihood of Failure (LOF) for both the PSV is greater than 1, some corrective Actions should be taken to reduce the value of LOF below 1. Flow Induced Pulsation a) Step 1: Determine critical side branch diameter Critical Diameter (d crit) = 1000 ( 400 πρv 2)0.5 (5) 400 Critical Diameter (d crit) = 1000 ( π 21394.20 )0.5 Critical Diameter (d crit) = 77.145 mm b) Step 2: Determine Reynolds Number For the two side branches the Reynolds Number of the flow in the main line is calculated using: Reynold s Number (Re) = ρvd char (6) 1000μ All rights reserved by www.ijste.org 42

Reynold s Number (Re) = 1169 4.278 303.15 1000 0.25 Reynold s Number (Re) = 6064.19 Where D Char is internal diameter of main line The Reynolds Number is below 1.6x10 7 and therefore S 1 needs to be calculated. c) Step 3: Calculate Strouhal Number Strouhal Number (S 1) = 0.420 ( d int D int ) 0.316 ( v c ) 0.083 ( Re 10 6) 0.065 (7) Strouhal Number (S 1) = 0.420 ( 303.15 303.15 )0.316 ( 4.278 2000 ) 0.083 ( 6064.19 10 6 ) 0.065 Strouhal Number (S 1) = 0.97491 Note, as the ratio of d int/d int not equal to 1 Strouhal Number (S 1) = fundamental Strouhal Number (S) = 0.97491 d) Step 4: Calculate Fundamental Excitation Frequency Fundamental Excitation Frequency (Fv) = S v (8) d int Fundamental Excitation Frequency (Fv) = 0.97491 4.278 1000 303.15 Fundamental Excitation Frequency (Fv) = 13.75 e) Step 5: Calculate fundamental acoustic natural frequency of side branch c Fundamental Acoustic Natural Frequency (Fs) = 0.206 Fundamental Acoustic Natural Frequency (Fs) = 0.206 2000 3.25 Fundamental Acoustic Natural Frequency (Fs) = 126.76 f) Step 6: Obtain LOF score The ratio of F v/f s is calculated: Ratio Fv/Fs=13.75/126.769=0.1084 Therefore, ratio of Fv/Fs is less than 1 scores an LOF of 0.29. Pulsation: Flow Induced Excitation LOF = 0.29 FIV Analysis Results L branch (9) From the Qualitative Assessment we get the value of Kinetic Energy (ρv 2 ) between 5000 & 20000 which falls under MEDIUM probability of failure due to Flow Induced Turbulence & Flow Induced Excitations, to calculate Likelihood of Failure (LOF). There is also possibility of Acoustic Induced Vibration (AIV) for Case-1 as pressure ratio is greater than 1.8. But, the possibility of failure due to AIV is ruled out as the Fluid used in the system is Liquid [1]. The support span founds to be adequate with respect to Quantitative Analysis. However, the requirement of additional supports or change in the supports can be obtained post Dynamic Stress Analysis results. Table - 2 Summary of Likelihood of Failure (LOF) score for FIV Sr. No. Excitation Mechanism Maximum Flow Normal Flow Minimum Flow 1 Flow Induced Turbulence 7.665 6.546 1.982 2 Flow Induced Pulsation 0.29 0.290 0.290 Dynamic Stress Analysis using CAESAR II The static model is generated to check the overall behavior of the pipe and supports. It has been informed that no supports at site are lifting off. Hence it can be concluded that all the rest supports are active. This is due to the fact that the supports are resting on platform connected to Flash Tank. The problem is then needs to be solved mainly for vibration purpose considering linear boundary conditions. The original model is shown following Figure 4. Fig. 4: Original CAESAR II Model All rights reserved by www.ijste.org 43

Based on vibration analysis report the harmonic analysis has been performed to simulate site conditions. The Vibration Survey Report has been used to simulate the model. The result obtained at 265kg/sec flow rate nearest to the control valve (Point D as per vibration measurement report) as shown in Fig. 3 (a) has been considered as bench mark results for comparison near to the control valve LV6301. The Vertical displacement of 215.4 microns found to be the largest amplitude [5]. Following table provides the comparison between actual data and calculated values. Table - 3 Comparison of results as per CAESAR II model and vibration report CAESAR II node Vibration Reading HD: Horizontal Displacements as per CAESAR II Frequency, Hz no. Point report, mm results, mm 340 A 0.114 5.6 0.005 300 B 0.084 11.9 0.02 310 C 0.084 14, R 0.014 210 D 0.215 15 0.217 220 E 0.131 15.6 0.14 150 F 0.114 4.4, R 0.12 160 G 0.085 4 0.15 Since the most probable source of vibration is the Flow Induced Turbulence in the control valve, the permanent solution may call for flow change and piping layout changes. However, at present the scope is to make minimum changes in the existing piping and that too without taking shut down. Hence, the scope is limited to avoid vibration transferring to the structure. The Detailed harmonic analysis suggested providing a viscoelastic damper to isolate the vibrations transferred to the structure. However, the before implementing this big change it is recommended to explore the option of Isolating pads. Recommendations The following recommendation shall be implemented in sequence one after another. It means First set of recommendation shall be implemented & vibration shall be observed. In case of unsatisfactory results implement second set. This approach may save cost. First Set of Recommendations Provide Temporary support to the pipe. Cut the trunnion at node 5020 next to the valve LV-6301 and attach a base plate to it and provide 2 Neoprene rubber pads each of 1 thickness using clamps [4]. Provide an additional clamp shoe at node 175. Insert 2 nos. of Neoprene isolating rubber pads each 1 thick to the base plate of shoe for isolation purpose. The assembly of support to be provided at node 175. Following diagram shows the general arrangement of the supports as per Solution 1. Fig. 5: Supports as per Solution 1 Following Table-4 provides a data sheet for selection of Isolation pads located at support Table - 4 Isolation or Neoprene Pad Data Sheet Material of the isolation pad to be used Neoprene rubber or Equivalent Operating temperature ( C) 124 C Excitation frequency (Hz) 4 Hz to 16Hz Load on each pad 0.6 N / sq.mm Stiffness of isolation pad 120 kn/mm Thickness of the isolation pad (mm) 2" THK pad. 1 Nos for each support All rights reserved by www.ijste.org 44

Permissible deformation 0.1 mm to 0.13 mm Application To isolate Pipe base from Supporting platform in event of Flow induced vibrations Second Set of Recommendations Keep support provided at node 5020 as it is. At node 175 instead of Neoprene pads, provide a viscoelastic damper [2]. The following diagram shows general arrangement of pipe supports. Fig. 6: Supports as per Solution 2 Following Table-5 provides a data sheet for selection of Damper located at support Table - 4 Isolation or Neoprene Pad Data Sheet Operating Temperature ( C) 124 C Critical frequencies at which vibration experienced 15 Hz Hot cold thermal displacement (mm) 1 mm to 2 mm Vertical damping resistance 335 kns/m Thermal movement of pipe in vertical direction 2 mm Maximum damping force 2000N to 4000N Application To isolate Pipe base from Supporting platform in event of FIV Damping fluid Bitumen based fluids allowing high damping parameters more than 2000lb-sec/inch at 16Hz V. RESULTS The displacement observed at various points after implementing the Solution 1 is as follows: Table - 4 Comparison of results as per Soln. 1 CAESAR II model and vibration report CAES AR II node no. Vibration Reading Point HD: Horizontal Displacements as per report, mm Frequency, Hz CAESAR II results, mm Solution 1 340 A 0.114 5.6 0.001 300 B 0.084 11.9 0.001 310 C 0.084 14, R 0.001 210 D 0.2154 15 0.036 220 E 0.131 15.6 0.05 150 F 0.114 4.4, R 0.026 160 G 0.085 4 0.034 The amplitude of vibration found to be reduced down considerably, after implementing the recommended Solutions with reference of previous vibration report. All rights reserved by www.ijste.org 45

VI. CONCLUSION The vibration measurement report has been considered as a reference to simulate the Piping system in stress analysis software CAESAR II. The bench mark results of vibration measurement at 265kg/sec have been compared against CAESAR II results. A harmonic analysis has been performed and solutions have been recommended. By considering the fact that those are to be implemented while system is in running condition. The solutions 1 suggest providing isolating rubber pads of higher frequencies at two locations. If solution one does not yield satisfactory results, then a viscous damper has been recommended as solution 2. Solution 2 results are predicted to be better than Solution 1. However, cannot be predicted as actual Damper properties will be available by vendor at later stage. ACKNOWLEDGMENT Author would like to thank Mr. Rajiv Desai and whole staff of the Protton Engineering for their direct or indirect support and contribution for this work. REFERENCES [1] V. A. Carucci and R. T. Mueller, Acoustically Induced Piping Vibration in High Capacity Pressure Reducing Systems, ASME 82-WA/PVP-8; 1982. [2] Energy Institute, Guidelines for the Avoidance of Vibration Induced Fatigue in Process Pipework 2 nd Edition, 2008. [3] F. L. Eisinger, Designing Piping Systems against Acoustically-Induced Structural Fatigue, ASME 1996, PVP-vol. 328; 1996. [4] Frank P. Barutzki, Extending the Service Life of Piping Systems through the Application of Viscous Fluid Dampers GERB Vibrations Control Systems, Inc. [5] VICODA- Product Boucher, Vibration Control Devices and Application UK. [6] WARCO-BILTRITE, Rubber Product Catalogue USA, November 1, 2014 [7] Vibration Survey Report EG 2- LV 6301 Provided by Vendor. All rights reserved by www.ijste.org 46