Quality Assurance Plan. March 30, Chemical Crystallography Laboratory

Similar documents
Structure Report for J. Reibenspies

Small Molecule Crystallography Lab Department of Chemistry and Biochemistry University of Oklahoma 101 Stephenson Parkway Norman, OK

Small Molecule Crystallography Lab Department of Chemistry and Biochemistry University of Oklahoma 101 Stephenson Parkway Norman, OK

Changing and challenging times for service crystallography. Electronic Supplementary Information

Facilities Management

Supplementary Information. Single Crystal X-Ray Diffraction

Laboratory Manual 1.0.6

RPR 29 CYCLOTRON RADIOCHEMISTRY LABORATORY

RADIATION SAFETY GUIDELINES FOR NON-USERS

Responsibilities: Effective Date: November Revision Date: February 8, VP, Facilities and Construction Management. Issuing Authority:

Zinc Metal Determination Perkin Elmer Atomic Absorption Spectrometer AAnalyst Procedures

Data Collection. Overview. Methods. Counter Methods. Crystal Quality with -Scans

THE UNIVERSITY OF NEWCASTLE SCHOOL of BIOMEDICAL SCIENCES

X-ray practical: Crystallography

Supporting Information

Scientific Integrity: A crystallographic perspective

Chemical Hygiene Plan for Laboratories

XRD RAPID SCREENING SYSTEM FOR COMBINATORIAL CHEMISTRY

Approval Block. Prepared by: Signature Date Evan Parnell 08 NOV Reviewed by: Signature Date. Approved by: Signature Date

Sigma Bond Metathesis with Pentamethylcyclopentadienyl Ligands in Sterically. Thomas J. Mueller, Joseph W. Ziller, and William J.

Remote Asymmetric Induction in an Intramolecular Ionic Diels-Alder Reaction: Application to the Total Synthesis of (+)-Dihydrocompactin

STANDARD OPERATING PROCEDURE NO. 70 DENSITY AND VOLUMETRIC WATER CONTENT BY THE SAND REPLACEMENT METHOD

Sample Alignment (2D detector) Part

APPENDIX E. Crystallographic Data for TBA Eu(DO2A)(DPA) Temperature Dependence

APPLICATION FOR AUTHORIZATION

Department of Chemistry Research Support Facilities Sept. 5,

Application Note SC-XRD 505 Single Crystal Diffraction

M2 TP. Low-Energy Electron Diffraction (LEED)

County of Cortland HAZARD COMUNICATION POLICY

Hach Method Total Organic Carbon in Finished Drinking Water by Catalyzed Ozone Hydroxyl Radical Oxidation Infrared Analysis

Chapter X: Radiation Safety Audit Program

CHEMICAL MANAGEMENT PLAN

ALLOWAY METHOD OUTLINE

Supporting Information. for. Angew. Chem. Int. Ed Wiley-VCH 2004

HOW TO ANALYZE SYNCHROTRON DATA

Applied Nuclear Science Educational, Training & Simulation Systems

Department of Environmental Health and Safety Laboratory Decommissioning and Clearance

Methyl acetoacetate at 150 K. The crystal structure of methyl acetoacetate, C 5 H 8 O 3, at 150 K contains discrete molecules.

HAZARD COMMUNICATION SAFETY PROGRAM

Supporting Information

University of Tennessee Safety Procedure

SYRACUSE UNIVERSITY RADIATION PROTECTION PROGRAM APPLICATION FOR USE OF RADIOACTIVE MATERIALS

Introduction to single crystal X-ray analysis VI. About CIFs Alerts and how to handle them

Sample Alignment Part

addenda and errata [N,N 0 -Bis(4-bromobenzylidene)-2,2-dimethylpropane-j Corrigendum Reza Kia, a Hoong-Kun Fun a * and Hadi Kargar b

MEMO. SUBJECT: 2004 Annual Assessment Reports for BS Chemistry

Individual Laboratory Safety & Chemical Hygiene Plan

Chemical Donation Policy. Santa Clara University (SCU) 500 El Camino Real Santa Clara, CA 95053

Reaction Landscape of a Pentadentate N5-Ligated Mn II Complex with O 2

Overview - Macromolecular Crystallography

HAZARD COMMUNICATION PROGRAM

Laboratory-Specific Information

Compact Orifice FlowMeter

Health, Safety, Security and Environment

Laboratory Certification Workshop

Application for Radioactive Material Use

High-Throughput in Chemical Crystallography from an industrial point of view

S8 TIGER Series 2 for ASTM D 6443

and Environmental Science Centre

metal-organic compounds

Setting The motor that rotates the sample about an axis normal to the diffraction plane is called (or ).

CHEMICAL INVENTORY ENTRY GUIDE

Rule 2. Rule 1. Rule 4. Rule 3. Rule 5. Rule 6. Rule 7. Rule 8

Accurate Measurement of Transmittance and Reflectance for Engineering Applications

The Art of in situ Cryocrystallization

Structure Validation in Chemical Crystallography with CheckCIF/PLATON

Atomic and nuclear physics

Hoffman Estates High School Engineering Students Return to ChemMatCARS For Argonne National Laboratory s ESRP

CALIFORNIA INSTITUTE OF TECHNOLOGY BECKMAN INSTITUTE X-RAY CRYSTALLOGRAPHY LABORATORY

QUALIFICATION SPECIFICATION

Supporting Information

Determination of the Rydberg constant, Moseley s law, and screening constant (Item No.: P )

Drexel University Chemistry Department Safety Training. September 2005

UNIVERSITY OF HOUSTON ENVIRONMENTAL HEALTH AND & LIFE SAFETY POLICIES AND PROCEDURES I. PURPOSE

HAZARD COMMUNICATION PROGRAM

Electrical safety testing Checklist

Stephen F. Nelsen, Asgeir E. Konradsson, Rustem F. Ismagilov, Ilia A. Guzei N N

Scandium and Yttrium Metallocene Borohydride Complexes: Comparisons of (BH 4 ) 1 vs (BPh 4 ) 1 Coordination and Reactivity

X-Rays Edited 2/19/18 by DGH & Stephen Albright

Ionizing Radiation Awareness (Non-User)

Crystals, X-rays and Proteins

Supplementary File. Modification of Boc-protected CAN508 via acylation and Suzuki-Miyaura Coupling

Standard Operating Procedure for: ph using Oakton ph 5+ Handheld ph Meter. Missouri State University. and

Technical Procedure for General Laboratory Equipment

Hazard Communication Policy

RADIATION SAFETY TRAINING SEALED SOURCES

(+-)-3-Carboxy-2-(imidazol-3-ium-1-yl)- propanoate

The Reciprocal Lattice

Iron Complexes of a Bidentate Picolyl NHC Ligand: Synthesis, Structure and Reactivity

Swanning about in Reciprocal Space. Kenneth, what is the wavevector?

electronic reprint (2,4,6-Trinitrophenyl)guanidine Graham Smith, Urs D. Wermuth and Jonathan M. White Editors: W. Clegg and D. G.

Atomic and nuclear physics

The University of Jordan Accreditation & Quality Assurance Center Course Syllabus Course Name: Practical Physics 4 ( )

Space Group & Structure Solution

ANALYSIS OF HYDRATES

Fast, Intuitive Structure Determination IV: Space Group Determination and Structure Solution

PARTICLE SIZE ANALYTICAL RANGES AND APPLICABILITY. m mm (10-6 m) nm (10-9 m)

Radioactive Waste Management

Multi-element process analyzer

The Abstraction of Iodine from Aromatic Iodides by Alkyl Radicals. Steric and Electronic Effects 1

Transcription:

Quality Assurance Plan Page 1 of 7 Quality Assurance Plan March 30, 2017 Chemical Crystallography Laboratory Author: Douglas R. Powell

Quality Assurance Plan Page 2 of 7 Distribution Douglas R. Powell, Laboratory Manager Prof. George B. Richter-Addo, Chair, Faculty User s Committee Laboratory copy maintained by Douglas R. Powell Revision Record Date Version Responsible Person Description of Change 1/4/2013 001 Douglas R. Powell Initial Release 1/30/2013 002 Douglas R. Powell Minor revisions 3/30/2017 003 Douglas R. Powell Minor revisions Table of Contents A. Project Summary 3 B. Project Description. 3 C. Quality Objectives and Criteria for Measurement of Data 4 D. Special Training and Certification. 4 E. Documents and Records. 5 F. Quality Control 5 G. Instrument Testing, Inspection, and Maintenance. 5 H. Assessment and Reporting. 6 I. References.. 6

Quality Assurance Plan Page 3 of 7 A. Project Summary Provide a single crystal chemical analysis service of small-molecule compounds to the students and researchers at the University of Oklahoma and more broadly to the citizens of the state of Oklahoma. A chemical analysis of a single crystal provides a geometrical description of the molecular and ionic species found in the crystal. Crystals are made up of repeating blocks of molecules. Because of the nature of the interaction between the radiation source and the atoms in these molecules, a model of the molecules from an average unit cell is produced. This laboratory strives to produce the best models of the molecular geometry available from the crystals provided and the department s instrument. This plan describes the activities carried out to assure that the best models are produced. B. Project Description The diffraction experiment involves shooting a beam of nearly monochromatic X-rays at a crystalline sample, measuring the relative intensities of the resulting diffraction pattern, and analyzing the diffraction data to determine the location and types of atoms (the model). From these atom locations, the bonding geometry between the atoms is determined. Our lab follows the guidelines for collecting and processing data, and refining chemical models that are set forth by the International Union of Crystallographers, IUCr, as described in the structure verification program checkcif (http://checkcif.iucr.org/). This verification program is utilized by the editors of all major journals to evaluate the quality of a small-molecule crystal structure that is included in any submitted manuscript. Small-molecule crystal structure analyses typically produce more data than is needed to uniquely determine the model, often producing 10-20 times as many unique data as there are variables in the model. These highly over-determined models nearly always lead to an unambiguous result. A statistical analysis of the data set is carried out as a part of each analysis. Standard uncertainties for the intensity data, the cell parameters, the atomic parameters, and the derived geometry objects are always reported. The crystal structure determinations conducted in this lab utilize a Bruker APEX ccd detector mounted on a 3-circle D8 goniometer with a sealed tube X-ray source, and a mono-capillary collimator. The samples are routinely cooled to 100 K using a nitrogen-gas streaming, Oxford Cryostream700 low-temperature device. This instrument was installed at the University of Oklahoma in 2002.

Quality Assurance Plan Page 4 of 7 C. Quality Objectives and Criteria for Measurement of Data Crystals are selected based upon their size and appearance. Single crystals are much easier to analyze than twinned crystals. Larger crystals tend to produce stronger (better) data sets. Experimental conditions such as counting time, thickness of slices of diffraction space, and sample-to-detector distance are optimized to produce the best data for the selected crystal. Typically, several crystals are screened to find the crystal with the strongest diffraction pattern for any sample. When possible, the counting time per image is adjusted to produce observable intensites at the highest scattering angles. Using this criteria to select the counting time, data will typically produce an average I/ (I) ratio of > 10 (the prefered level of precision used in this lab). Unfortunately, not all crystals diffract to IUCr minimum limits of sin max / > 0.6 Å -1. Data are still collected on these samples presuming that some description of the crystal structure is better than no description of the crystal structure. The solid angle thickness of slices is routinely set at 0.5 so that each diffraction maximum appears on 2-3 consecutive slices (images) of diffraction space. When the samples scatter poorly producing large spots, the thickness of each image is adjusted to make 2-3 slices through each spot. In most cases, leaving the sample-to-detector distance at 5 cm is sufficient. However, when a unit cell axial length in the sample is > 25 Å, the diffraction maxima appear to blend together forming diffraction lines. The sample-to-detector distance is increased to produce diffraction patterns with discrete spots. Note that when this distance is > 7 cm, then data must be collected with at least two swing-angle detector settings to collect sufficient data for the IUCr minimum standards. To attain the best quality measurements of our diffraction intensities, multiple measurements of the symmetry-unique data are made. For systems with monoclinic or higher symmetry, our lab tries to achieve an average data redundancy of at least 4. For triclinic systems, our lab tries to achieve an average data redundancy of at least 3. D. Special Training and Certification All users of the facility must have annual training in radiation safety from the University s Radiation Safety Office (http://www.ouhsc.edu/rso/), as well as annual training from the University s Environmental Health and Safety Office in chemical hazards, chemical waste disposal, and fire safety. The lab manager should have training from the manufacturer on the operation and maintenance of the instrument. Other users of the facility will be trained by the lab manager in the use of the instrument and computer software.

Quality Assurance Plan Page 5 of 7 E. Documents and Records Records of the radiation safety training will be maintained by the University s Radiation Safety Office. Records of the chemical and fire safety training will be maintained by the University s Environmental Health and Safety Office. Records of lab user s training will be maintained by the CCL laboratory manager. F. Quality Control Users are to follow the procedures outlined in the series of standard operating procedures prepared for the Chemical Crystallography Laboratory. APEX Instrument Operating Instructions OUCB-CCL-1.003 3/30/2017 Alignment and Calibration of the APEX Instrument OUCB-CCL-2.003 3/30/2017 Mounting Samples OUCB-CCL-3.003 3/30/2017 Center the Sample on the Instrument OUCB-CCL-4.003 3/30/2017 Data Collection Using APEX3 OUCB-CCL-5.003 3/30/2017 Data Reduction and Processing OUCB-CCL-6.003 4/10/2017 Chemical Waste Disposal from Detector Chiller OUCB-CCL-7.002 3/30/2017 All crystal structures determined in this lab will be evaluated using the checkcif program developed by the International Union of Crystallographers (http://checkcif.iucr.org/). Serious issues such as A and B level alerts must be addressed in a lab report describing the structure. G. Instrument Testing, Inspection, and Maintenance Weekly checks of the general laboratory conditions will be made to assure that all pieces of equipment are working as specified. Problem issues will be noted and addressed as soon as possible. The precision of the instrument will be assessed by the results of a semi-annual analysis of a standard sample, provided by the manufacturer. For these analyses, the instrument will first be aligned according to the procedures in Alignment and Calibration of the APEX instrument. Then intensity data will be collected and processed by a standard procedure, and the values of average I, average I/ (I), cell parameters, and refined R1 and wr2 kept by the lab manager as a permanent lab record for this instrument. Annually these preventive maintenance steps will be performed: check and clean all screens in the water cooling system for the generator, replace the cooling water in the Haskris and Neslab

Quality Assurance Plan Page 6 of 7 water coolers, clean and lubricate the gears of the omega and 2theta drives, empty, drain, and dry the 60 liter supply Dewar for the LT device, check all voltages in the D8 controller using the D8Tools program. Assessment and Reporting The checkcif report for each crystal structure will be included with data files for each project. External assessment of crystal structures submitted for publication is provided by reviewers of manuscripts that include the crystal structures. Users are encouraged to discuss ideas for improving lab activities with either the lab manager or the faculty supervisor chairing the lab faculty committee. Annual surveys will be sent out to all users asking for additional input. All suggestions will be strongly considered and, when possible, will be implemented. An annual report of the productivity of the facility is presented to both the chair of the faculty oversight committee and the Department s assistant chairman. References http://checkcif.iucr.org/ Web site to submit crystal structure model and data to verify and validate one or more crystal structures. http://www.ouhsc.edu/rso/ Web site for the Radiation Safety Office of the University of Oklahoma. APEX Instrument Operating Instructions. OUCB-CCL-1.003, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma. Alignment and Calibration of the APEX Instrument, OUCB-CCL-2.003, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma. Mounting Samples, OUCB-CCL-3.003, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma. Center the Sample on the Instrument, OUCB-CCL-4.003, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma.

Quality Assurance Plan Page 7 of 7 Data Collection Using APEX3, OUCB-CCL-5.004, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma. Data Reduction and Processing, OUCB-CCL-6.003, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma. Chemical Waste Disposal from Detector Chiller, OUCB-CCL-7.002, Chemical Crystallography Laboratory, Department of Chemistry and Biochemistry, University of Oklahoma.