First tests of the big volume ultra low background gamma spectrometer

Similar documents
Coincidence gamma-ray spectrometry

RADON EQUILIBRIUM MEASUREMENT IN THE AIR *

Compton suppression spectrometry

Measurement of 39 Ar in Underground Argon for Dark Matter Experiments

Cosmogenic and primordial radioisotopes in copper bricks shortly exposed to cosmic rays

Design, Construction, Operation, and Simulation of a Radioactivity Assay Chamber

SECTION 8 Part I Typical Questions

Quality Assurance. Purity control. Polycrystalline Ingots

GERDA Meeting, September 2009, LNGS. News from Low-Level-Lab: Attempt to Reduce Neutron Background at Shallow Depths

Ultra-Low Background Counting and Assay Studies At SNOLAB

Neutrino Physics. Neutron Detector in the Aberdeen Tunnel Underground Laboratory. The Daya Bay Experiment. Significance of θ 13

A coincidence method of thorium measurement

Introduction to Environmental Measurement Techniques Radioactivity. Dana Pittauer 1of 48

Ultra-Low Background Measurement Capabilities At SNOLAB

ON THE OMNIPRESENT BACKGROUND GAMMA RADIATION OF THE CONTINUOUS SPECTRUM

- The CONUS Experiment - COherent elastic NeUtrino nucleus Scattering

Status of the GERDA experiment

The Ones That Got Away: Neutron Leakage Spectra

Low Background Experiments and Material Assay. Tessa Johnson NSSC Summer School July 2016

Measurements of natural radioactivity in the salt cavern of the Polkowice Sieroszowice copper mine

Study well-shaped germanium detectors for lowbackground

EFFICIENCY SIMULATION OF A HPGE DETECTOR FOR THE ENVIRONMENTAL RADIOACTIVITY LABORATORY/CDTN USING A MCNP-GAMMAVISION METHOD

Low Background Counting At SNOLAB

Interactive Web Accessible Gamma-Spectrum Generator & EasyMonteCarlo Tools

The Dortmund Low Background Facility Low-Background Gamma Ray Spectrometry with an Artificial Overburden

hν' Φ e - Gamma spectroscopy - Prelab questions 1. What characteristics distinguish x-rays from gamma rays? Is either more intrinsically dangerous?

Basic hands-on gamma calibration for low activity environmental levels

Testing Dynamical Reduction Models at the Gran Sasso underground laboratory

Results of the 2015 national indoor radon intercomparison measurements in Serbia

SuperCDMS SNOLAB: A G2 Dark Matter Search. Ben Loer, Fermilab Center for Particle Astrophysics On behalf of the SuperCDMS Collaboration

The NEXT-100 experiment for Neutrino-less Double Beta decay: Main features, Results from Prototypes and Radiopurity issues.

Gamma-Spectrum Generator

Inaccuracy Determination in Mathematical Model of Labsocs Efficiency Calibration Program

arxiv:nucl-ex/ v2 21 Jul 2005

Search for Dark Matter with Liquid Argon and Pulse Shape Discrimination

TECHNICAL WORKING GROUP ITWG GUIDELINE ON LABORATORY APPLICATIONS OF HIGH-RESOLUTION GAMMA SPECTROMETRY

Introduction to Radiological Sciences Neutron Detectors. Theory of operation. Types of detectors Source calibration Survey for Dose

The XENON Dark Matter Project: Status of the XENON100 Phase. Elena Aprile Columbia University

Germanium Detectors. Germanium, a special material. Detectors, big is beautiful. Operational features. Applications. Iris Abt

ABSORPTION OF BETA AND GAMMA RADIATION

K 40 activity and Detector Efficiency

Low Background NAA: A powerful tool for Physics of Rare Experiments and Environmental Sciences

28th Seismic Research Review: Ground-Based Nuclear Explosion Monitoring Technologies DESIGN OF A PHOSWICH WELL DETECTOR FOR RADIOXENON MONITORING

Preparation of Standard Source as a Petri Dish for Plant by Using

Identification of Naturally Occurring Radioactive Material in Sand

DOUBLE BETA DECAY OF 106 Cd - EXPERIMENT TGV (Telescope Germanium Vertical) EXPERIMENT SPT (Silicon Pixel Telescope)

Gamma and X-Ray Detection

Chem 481 Lecture Material 3/20/09

EXPERIMENTAL STUDY OF NEUTRON FIELDS PRODUCED IN PROTON REACTIONS WITH HEAVY TARGETS. Nuclear Physics Institute AS CR, Rez Czech Republic

Background rejection techniques in Germanium 0νββ-decay experiments. ν=v

Measurement of Specific Activities of Some Biological Samples for Some Iraq Governorates

Backgrounds in PICO. Eric Vázquez Jáuregui SNOLAB. AARM Meeting Fermilab; Batavia IL, USA; March 19, 2014

DARK MATTER SEARCHES AT CANFRANC: ANAIS AND ROSEBUD: an update INTRODUCTION AND EXPERIMENTAL GOALS SUMMARY OF RECENT ACHIEVEMENTS AND EFFORTS

Technical Specifications and Requirements on Direct detection for Dark Matter Searches

PHYS 3650L - Modern Physics Laboratory

Isotopes and Radioactive Decay

Gamma Ray Photons and Neutrons from Mars: Student Reading

ANAIS: Status and prospects

The 46g BGO bolometer

arxiv: v1 [nucl-ex] 13 Nov 2014

Testing Dynamical Reduction Models at the underground Gran Sasso Laboratory

Trace Element Analysis of Geological, Biological & Environmental Materials By Neutron Activation Analysis: An Exposure

29th Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies AUTOMATED QA/QC CHECK

Overview about the Work with Liquid Scintillators

Background Neutron Studies for Coherent Elastic Neutrino-Nucleus Scattering Measurements at the SNS

arxiv: v1 [physics.ins-det] 26 May 2015

Shielding Strategies. Karl Tasso Knöpfle MPI Kernphysik, Heidelberg

An introduction to Neutron Resonance Densitometry (Short Summary)

The GERmanium Detector Array

Background simulations and shielding calculations

Background Characterization and Rejection in the LZ Detector. David Malling Brown University IDM 2012 July 25, 2012

arxiv: v1 [nucl-ex] 20 Dec 2008

He-3 Neutron Detectors

Analysis of Radioactive Disequilibrium in Natural Decay Chains due to Processing

INTRODUCTION TO MEDICAL PHYSICS 1 Quiz #1 Solutions October 6, 2017

Rivelazione di neutrini solari - Borexino Lino Miramonti 6 Giugno 2006 Gran Sasso

Measurement of induced radioactivity in air and water for medical accelerators

K 40 activity and Detector Efficiency

Chapter Four (Interaction of Radiation with Matter)

ANAIS: Status and prospects

Simulating Gamma-Ray Telescopes in Space Radiation Environments with Geant4: Detector Activation

Background and sensitivity predictions for XENON1T

Preparatory experiments for cold-neutron induced fission studies at IKI

Cross Calibration for using Neutron Activation Analysis with Copper Samples to measure D-T Fusion Yields

Natural Radiation K 40

Background by Neutron Activation in GERDA

Radioactivity measurements and risk assessments in soil samples at south and middle of Qatar

X-RAY SCATTERING AND MOSELEY S LAW. OBJECTIVE: To investigate Moseley s law using X-ray absorption and to observe X- ray scattering.

Complex set of cosmic rays monitoring

Multi Channel Analyzer (MCA) Analyzing a Gamma spectrum

Digital simulation of neutron and gamma measurement devices

SCINTILLATION DETECTORS AND PM TUBES

Radiation in Environment

The first model was based only on the CANBERRA information which we. drawing. Canberra refused any other information.

DETECTORS. I. Charged Particle Detectors

Basic physics Questions

Interaction of Ionizing Radiation with Matter

2010 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies

Analysis of γ spectrum

the DarkSide project Andrea Pocar University of Massachusetts, Amherst

Transcription:

First tests of the big volume ultra low background gamma spectrometer N. Todorović,, D. MrđaM rđa,, I. Bikit, M. Vesković,, S. Forkapić,, J. Slivka Departman za fiziku, PMF, Novi Sad

1. Introduction Even in the absence of a radioactive source, germanium spectrometer ter exhibits certain counting rate,caused by natural radioactive elements distributed in the surrounding of the detector and by cosmic rays. The naturally occurring radioactivity originates from 3 radioactive chains 232 Th, 238 U and 235 U, and from 40 K. Natural potassium contains 0.0117% of 40 K emitting the 1460.8 kev gamma quanta. Very often, this line is one of the major background components. Lead, which is often used as shielding material, may contain 210 Pb which will contribute to the background, mainly the by the bremsstrahlung of its daughter 210 Bi. The responsibility of the manufacturer is to reduce the radioactivity of detector itself and of passive shield by careful l selection of radiopure materials. The neutrons produced by cosmic rays can manifest themselves by different nuclear reactions characterized by gamma lines. That can be the inelastic scattering of fast neutrons ( (n,n( n,n,, ) reactions ), or absorption of thermal neutrons ( (n,( n,γ) ) reactions).

2. Experimental results and discussion The ultra-low low background, big volume germanium spectrometer, made by Canberra is located in the surface laboratory of Department of Physics P in Novi Sad ( Fig.1). It has 100% relative efficiency ( the same absolute a efficiency as 3"x 3" NaI(Tl) ) detector at 1332 kev),what corresponds to about 380 cm 3 of detector active volume. The front window of detector end- cap is only 0.89 mm thick and it is made of an high-strength carbon fiber composite, which provides greater than 85 % transmissions for photon p energy above 15 kev,, and nearly 100% transmissions for photon energy above 20 kev.. The spectrometer is closed-end end coaxial type with U-style U cryostat configuration. Fig.1 View of the ultra low-background germanium spectrometer (a) ;

Detector shield is constructed with layered bulk lead. The outer five inches (125 mm) is ordinary low-background lead while the innermost one inch (25 mm) is selected for 210 Pb content of about 20 Bq/kg. The passive shield has a inner lining to stop the lead K-shell K X-rays X in the energy range of 75-85 kev.. Lining materials (Fig. 1 b) are low-background tin with a thickness of 1 mm, and high purity copper with a thicknesses of 1.5 mm. Also, the Sn X-rays ( 25-28 kev) ) are reduced by copper. The shield is equipped with a gas port for the introduction of nitrogen from Dewar vessel to flush the shield interior and reduce background from radon and radon daughters. The total mass of the shield is 1633 kg. Fig 1b. Position of the detector housing inside lead shield

The comparison between background spectra of bare detector and shielded detector is presented on Fig. 2. Vertical axis represents the total number of registered events, while the horizontal axes represents the energies of gamma quanta in kev.. The acquisition time was 517 ks. The reduction factor found for the complete spectrum, in the range of 40keV to 2768keV was 238. The 511 kev annihilation line is reduced less than the other environmental background lines due to its cosmic origin. Fig.2. Background spectra of bare big volume Ge detector ( upper spectrum) and shielded detector (lower spectrum ) Table 1.Comparison of intensities for several significant gamma lines

The most prominent gamma lines in the background of shielded big- volume Ge spectrometer are neutron induced lines (Fig.3). These lines are listed in Table 2. Their intensities are compared with corresponding background lines of 32 % relative efficiency Ge detector shielded by lead (wall thickness 12 cm, inner layers Sn (3.5 mm)+ Cu (0.5 mm), total mass 708 kg). Table 2.The intensities of neutron produced background gamma lines in Ge detectors of relative efficiencies 100% and 32%. The ratios of intensities are given in 5-th column. Fig.3. Gamma lines produced by neutrons in (n,n, ) reactions and (n,γ) reactions. The numbers near the peaks represent energies in [kev].

Fig.4. The ratio of intensities of neutron induced lines in 100% relative efficiency Ge detector and 32% relative efficiency Ge detector,respectively. Value 3.125 is the ratio of relative efficiencies for two detectors.

The comparison of several background lines intensities and integral count rates for big volume detector and 32% relative efficiency detector is presented in Table 3. Table 3.

For the future purpose, the ultra-low low gamma spectrometer will be upgraded by two plastic scintillators ( Fig.5). These two plastics and Ge detector will operate in the coincidence mode. In such configuration, system will be used for the investigation of different processes induced by direct interaction of cosmic muons and certain materials.

3. Conclusions The new ultra-low low background big volume gamma spectrometer exhibits very good performances. From comparison with another ultra-low low background system of 32% relative efficiency Ge spectrometer (Tab.3) it is obvious that the new system has lower integral count rate and lower intensities of background lines ( having in mind efficiencies ratio of 3.125 for these two detectors). For the reduction of neutron induced gamma lines relatively thin layers of materials with high concentration of boron will be used. A good example are only 3.2 mm thick FLEX BORON silicon sheets, which contain 25 weight-percent of uniformly distributed boron with high cross section for thermal neutrons.