Prep 150 LC System: Considerations for Analytical to Preparative Scaling

Similar documents
Peptide Isolation Using the Prep 150 LC System

UPC 2 Strategy for Scaling from Analytical to Preparative SFC Separations

Streamlining the Analysis of Oral Contraceptives Using the ACQUITY UPLC H-Class System

Basic Principles for Purification Using Supercritical Fluid Chromatography

Routine MS Detection for USP Chromatographic Methods

USP Method Transfer and Routine Use Analysis of Irbesartan Tablets from HPLC to UPLC

A Quality by Design (QbD) Based Method Development for the Determination of Impurities in a Peroxide Degraded Sample of Ziprasidone

Online Reaction Monitoring of In-Process Manufacturing Samples by UPLC

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

Implementation of Methods Translation between Liquid Chromatography Instrumentation

Effects of Aqueous Sample Content and Aqueous Co-Solvent Composition on UPC 2 Separation Performance

Successfully Scaling and Transferring HPLC and UPLC Methods

Multi-Channel SFC System for Fast Chiral Method Development and Optimization

The Use of the ACQUITY QDa Detector for a Selective, Sensitive, and Robust Quantitative Method for a Potential Genotoxic Impurity

[ a ppl ic at ion no t e ]

Dilution(*) Chromatography

Application Note. Pharmaceutical QA/QC. Author. Abstract. Siji Joseph Agilent Technologies, Inc. Bangalore, India

Expediting Achiral SFC Method Development Using a Multi-Channel SFC System with MS Detection

SEAMLESS INTEGRATION OF MASS DETECTION INTO THE UV CHROMATOGRAPHIC WORKFLOW

LC Technical Information

Automating Method Development with an HPLC System Optimized for Scouting of Columns and Eluents

Rapid, Reliable Metabolite Ratio Evaluation for MIST Assessments in Drug Discovery and Preclinical Studies

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

A Workflow Approach for the Identification and Structural Elucidation of Impurities of Quetiapine Hemifumarate Drug Substance

DEMONSTRATING SUPERIOR LINEARITY: THE ACQUITY UPLC PHOTODIODE ARRAY DETECTOR

Analysis of Organic Light Emitting Diode Materials by UltraPerformance Convergence Chromatography Coupled with Mass Spectrometry (UPC 2 /MS)

-xt. -xt SYSTEM. Specifications for PAL-xt Systems. Valid for PAL-xt System models only. Prep and Load Platform

ANALYSIS OF BASIC COMPOUNDS

Varian Galaxie Chromatography Data System for Preparative HPLC

HPLC Praktikum Skript

Transferring Yesterdays Methods to Tomorrows Technology: The Evolution from HPLC to UPLC TM

Performance characteristics of the Agilent 1290 Infinity Quaternary Pump

Lirui Qiao, 1 Rob Lewis, 2 Alex Hooper, 2 James Morphet, 2 Xiaojie Tan, 1 Kate Yu 3

High Performance Liquid Chromatography. Table 1: Allowed HPLC Adjustment of USP <621> and EP <2.2.46>

Identification and Characterization of an Isolated Impurity Fraction: Analysis of an Unknown Degradant Found in Quetiapine Fumarate

Supporting Information Synthesis of BODIPY-Peptide Conjugates for Fluorescence Labeling of EGFR over-expressing Cells

Impact of Instrument Dispersion on Performance of HPLC Capillary Columns

Solvent Flexibility for Size-Based Polymer Analysis Using the Advanced Polymer Chromatography (APC) System

Application Note Pharmaceutical QA/QC. Agilent Application Solution. Authors. Abstract. Syed Salman Lateef Agilent Technologies, Inc.

Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation, Milford, MA USA APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS

UPLC Intact MASS Analysis Application Kit

Agilent 1200 Infinity Series HDR DAD Impurity Analyzer System for the Quantification of Trace Level of Genotoxic Impurity

Open Column Chromatography, GC, TLC, and HPLC

ACQUITY UPLC Peptide BEH C 18, 130Å and 300Å Columns

[application note] ACQUITY UPLC/SQD ANALYSIS OF POLYMER ADDITIVES. Peter J. Lee, and Alice J. Di Gioia, Waters Corporation, Milford, MA, U.S.A.

Luna 2.5 µm C18(2)-HST. Advantages of 2.5 µm for increasing the speed of analysis while maintaining high efficiency

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

Quantitation of High Resolution MS Data Using UNIFI: Acquiring and Processing Full Scan or Tof-MRM (Targeted HRMS) Datasets for Quantitative Assays

Chromatography. Gas Chromatography

Quad-Z 215 with Disposable Tips: Implementing the Use of ZipTips for the Purification of Biological Samples

LC and LC/MS Column Selection Flow Chart

Sensitive HILIC UHPLC-UV determination of steviol glycoside natural sweeteners

Fast methods for the determination of ibuprofen in drug products

LC walk-up system using the Agilent 1200 Series LC Method Development Solution and Agilent Easy Access software. Application Note

Comparing the Microlab 600 to Volumetric Glassware and Air Displacement Pipettes. January 2013

UPLC Method Development and Validation

Transferring HPLC methods from the HP 1090 Series to the Agilent 1100 Series HPLC system

Extraction of Methylmalonic Acid from Serum Using ISOLUTE. SAX Prior to LC-MS/MS Analysis

Analysis of Beer by Comprehensive 2D-LC with the Agilent 1290 Infinity 2D-LC system

Figure 1. Structures for Vitamin B2 and Vitamin B1.

C HA R AC T E RIZ AT IO N O F INK J E T P RINT E R C A RT RIDG E INK S USING A CHEMOMETRIC APPROACH

Comparing the MICROLAB 600 to Volumetric Glassware and Air Displacement Pipettes. June 2011

Biochemistry. Biochemical Techniques HPLC

Simplified Approaches to Impurity Identification using Accurate Mass UPLC/MS

HPLC Preparative Scaleup of Calcium Channel Blocker Pharmaceuticals Application

Method Transfer between HPLC and UHPLC Instruments Equipment-related challenges and solutions

Automated method development using Agilent 1100 Series HPLC systems, Agilent ChemStation and ChromSword software. Application

Application Note. Author. Abstract. Xinlei Yang Agilent Technologies Co. Ltd Shanghai, China

Accurate quantification of oleanolic acid and ursolic acid in traditional chinese medicine

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

STUDY OF LOADABILITY AND SELECTIVITY OF PHARMACEUTICAL COMPOUNDS ON RPLC COLUMNS

Exceptional Selectivity of Agilent ZORBAX Eclipse Plus Phenyl-Hexyl Columns to Separate Estrogens

TEMPLATE FOR AN EXAMPLE STANDARD TEST METHOD

ChromTech HPLC System

Analysis of Stachydrine in Leonurus japonicus Using an Agilent ZORBAX RRHD HILIC Plus Column with LC/ELSD and LC/MS/MS

637. Thiamethoxam. HPLC method

Enantiomeric and Diastereomeric Separations of Pyrethroids Using UPC 2

High Performance Liquid Chromatography

Speeding up 2D chromatography (HPLCxSEC) at it s limits. ..fast, faster ups broken...

Welcome to our E-Seminar: Choosing HPLC Columns for Faster Analysis Smaller and Faster

Using High Speed/High Resolution Size Exclusion Chromatography Separation of Polymeric Materials with Light Scattering Detection

Liquid Chromatography

OVERVIEW INTRODUCTION. Michael O Leary, Jennifer Gough, Tanya Tollifson Waters Corporation, Milford, MA USA

LC III: HPLC. Originally referred to as High-Pressure Liquid Chromatography. Now more commonly called High Performance Liquid Chromatography

Rapid Screening and Analysis of Components in Nonalcoholic Drinks Application

Scaling Up to Preparative Chromatography

Fast and Flexible Optimization of Modifier Concentrations Using an Agilent 1290 Infinity LC System with Blend Assist

Evaluation of Ketone Containing Terpene Compounds using Evaporative Light Scattering Detection

High Pressure/Performance Liquid Chromatography (HPLC)

Performance evaluation of the Agilent 1290 Infinity 2D-LC Solution for comprehensive two-dimensional liquid chromatography

Figure 1. Structures for Vitamin B2 and Vitamin B1.

Quantitative Analysis of EtG and EtS in Urine Using FASt ETG and LC-MS/MS

Yun W. Alelyunas, Mark D. Wrona, Russell J. Mortishire-Smith, Nick Tomczyk, and Paul D. Rainville Waters Corporation, Milford, MA, USA INTRODUCTION

Analysis of Serum 17-Hydroxyprogesterone, Androstenedione, and Cortisol by UPLC-MS/MS for Clinical Research

PosterREPRINT AN INTERACTIVE PHYSICOCHEMICAL PROPERTY PROFILING SOFTWARE FOR EARLY CANDIDATE ANALYSIS IN DRUG DISCOVERY INTRODUCTION

Nexera UC Unified Chromatography

Traditional Herbal Medicine Structural Elucidation using SYNAPT HDMS

The new Agilent 1290 Infinity Quaternary LC

Ultrafast and sensitive analysis of sweeteners, preservatives and flavorants in nonalcoholic beverages using the Agilent 1290 Infinity LC system

for Acclaim Mixed-Mode HILIC-1 Column

Transcription:

Andrew Aubin and Jo-Ann Jablonski Waters Corporation, Milford, MA, USA APPLICATION BENEFITS The Prep 150 LC System is an affordable, highly reliable system for preparative chromatography and is suitable for large bio-molecule compound isolation. Using the Prep 150 LC System, analytical chromatography can be easily and successfully scaled to preparatory chromatography using a systematic approach. INTRODUCTION To minimize the consumption of sample and solvents, there is a benefit in developing separation methods on a small scale and transferring them to a larger scale. Taking into account the important parameters and applying appropriate scaling factors, users can successfully scale up from analytical chromatography to larger scale preparative separations. In this application note, the analytical scale separation of chicken egg white is used to demonstrate the calculations and techniques used to successfully transfer from a 4.6 mm I.D. analytical column separation to a 19 mm I.D. preparatory column separation. The Prep 150 LC System is controlled by ChromScope Software, an intuitive and easy-to-use software that enables users to quickly purify compounds, reducing the amount of time required for training. WATERS SOLUTIONS Alliance HPLC System Prep 150 LC System Empower 3 Software ChromScope v. 1.4.1 Software XBridge Protein BEH C 4 OBD Prep Column, 300Å XBridge Protein BEH C 4 Column, 300Å KEY WORDS ChromScope, scaling, preparative HPLC, OBD prep columns, Prep 150 LC, egg white 1

E X P E R IM E N TA L Sample description Lyophilized chicken egg white was dissolved in mobile phase A at a concentration of 10 mg/ml. The sample was filtered through a 0.45-µm syringe tip filter prior to use. Method conditions Analytical scale separation: System: Alliance 695 with a 998 PDA Detector Flow rate: 1.5 ml/min Mobile phase A: Water + 0.05% TFA Mobile phase B: Acetonitrile + 0.05% TFA Gradient: 10 to 60% B over 15 minutes Injection volume: 5 µl Detection: UV at 0 nm Data: Empower 3 Column: XBridge Protein BEH C 4 Column, 300Å, 5 µm, 4.6 mm x 150 mm Preparative chromatographic separations were carried out using two different Waters Prep 150 LC System configurations to demonstrate scaling capability. Configuration 1 Pump: 545 Binary Gradient Module Detector: 489 UV Detector with Semi Prep Flow Cell Injector: Manual Prep Injector configured with a ml loop Collector: Fraction Collector 3 Configuration Pump: 545 Quaternary Gradient Module Detector: 998 Photo Diode Array with Semi Prep Flow Cell Injector: 707 Autosampler configured with a 10 ml loop Collector: Fraction Collector 3 Both Prep 150 LC System configurations were controlled using ChromScope Software, v1.4.1. Column temp.: Flow rate: Mobile phase A: Mobile phase B: Gradient on configuration 1: Ambient 5.6 ml/min Water + 0.05% TFA Acetonitrile + 0.05% TFA 10 to 60% B over 15 minutes following a 0.7 min isocratic hold Gradient on configuration : 10 to 60% B over 14.75 minutes Injection volume: 46 µl Detection: UV at 0 nm Column: XBridge Protein BEH C 4 OBD Prep Column, 300Å, 5 µm, 19 mm x 150 mm

RESULTS AND DISCUSSION Successful method scaling from analytical HPLC to preparative HPLC requires a systematic approach and attention to several factors. Factor 1: Analytical method Users should try and develop the best analytical method possible. Better analytical methods mean better preparatory methods. Three of the most common issues users encounter when developing methods that will be scaled to prep are: Column heating. Prep systems generally do not have column heating capability, therefore the analytical method should be developed at room temperature. Column heating is possible at a preparative scale, details of these techniques have been previously described. 1 No loading studies. If possible, it is helpful for users to do a loading study at the analytical scale to confirm that adequate resolution will be maintained at the preparative scale. Inadequate re-equilibration time. Following a gradient separation (regardless of scale), the system and column need to be re-equilibrated prior to the next injection. The best rule of thumb for re-equilibration is to pump 3X system volume plus 5X column volume of the initial mobile phase composition prior to the injection. Factor : Mobile phases, samples, and columns Mobile phases need to be the same at both the analytical and preparative scales, identical A, identical B, and same additive concentration. Samples need to be made at the same concentration using the same diluent. For the greatest chance of success, try to use columns of the same length, chemistry, and particle size. Using matched columns will provide similar resolution of critical pairs at all separation scales. Waters offers a wide range of column chemistry choices available in analytical and preparative scale dimensions. Of course, it is possible to use columns of different lengths and particle sizes; the chromatography will be similar, but the resolution of some components will be different and loading capacity could also be affected. Factor 3: Flow rates To maintain separation quality, the flow rate must be scaled based on column dimensions. With columns of identical particle size, the following equation is used to geometrically scale flow rate: F PREP = F ANALYTICAL D D PREP ANALYTICAL where F is flow rate (ml/min) and D is the inner diameter of the column (mm). For example, a 1.5 ml/min flow rate on a 4.6 mm I.D. column equates to a 5.6 ml/min flow rate on a 19 mm I.D. column., 3

Factor 4: Injection volume To maintain peak shape and loading capacity, the injection volume needs to be suitably scaled using the following equation: D PREP LPREP Vol PREP = VolANALYTICAL, D ANALYTICAL LANALYTICAL where Vol is the injection volume (µl), D is the inner diameter of the column (mm), and L is the column length (mm). For example, a 5 µl injection on a 4.6 x 150 mm column corresponds to a 46 µl injection on a 19 x 150 mm preparative column. Factor 5: Gradient scaling When columns are of identical length, changes to the gradient profile are required based on the system volume. To make these adjustments, the system volume must be measured for both the analytical and preparative system. Details on this procedure are included in the Preparative OBD Columns Calculator (Figure 1). The columns calculator provides an easy to use tool that aids in all of the analytical-to-preparative scaling calculations described in this application note. A version of the columns calculator is also embedded in Waters ChromScope Software. Figure 1. Waters Preparative OBD Columns Calculator home screen. To demonstrate the previously described techniques, the analytical separation method (developed on an HPLC system with a system volume of 0.65 ml) described in the experimental section was scaled to preparative 19 mm I.D. preparative column on two independent Prep 150 LC Systems, a manual injector configuration (system volume of 4.5 ml) and an automated injector based configuration (system volume of 17.5 ml). The scaled flow rates and injection volumes (all calculated using the Preparative OBD Columns Calculator) are shown in the experimental section. 4

As can been seen from Figure, the analytical method provides good separation of major peaks in the egg white sample. Regardless of the Prep 150 LC System configuration, the scaled preparative chromatography is very similar (Figures 3 and 4). When compared to the original 4.6 mm I.D. scale, it can be seen that in terms of resolution and retention time the chromatography is again very similar (Table 1). This simple experiment demonstrates that a systematic approach to scale up meets the goal of maintaining chromatographic resolution between key components and enables users to better predict chromatographic performance between analytical and preparative chromatography. 3.00.80.60 1.190.40.0.00 1.80 1.60 AU 1.40 1.0 1.00 0.80 0.60 0.40 0.0 6.005 8.750 9.58 11.799 0.00 0.00 1.00.00 3.00 4.00 5.00 6.00 7.00 8.00 9.00 10.00 11.00 1.00 13.00 14.00 15.00 16.00 Minutes Figure. Separation of a chicken egg white sample using a XBridge Protein BEH C 4 Column, 300Å, 5 µm, 4.6 mm x 150 mm on an Alliance HPLC System. Elapsed Time (min) Figure 3. Separation of a chicken egg white sample using a XBridge Protein BEH C 4 OBD Prep Column, 300Å, 5 µm, 19 mm x 150 mm on Prep 150 LC System configuration 1. 5

Elapsed Time (min) Figure 4. Separation of a chicken egg white sample using a XBridge Protein BEH C 4 OBD Prep Column, 300Å, 5 µm, 19 mm x 150 mm on Prep 150 LC System configuration. Alliance HPLC Alliance HPLC Prep 150 LC Config. 1 Prep 150 LC Config. 1 Table 1. Retention time and resolution comparison (minutes) of the 4 major peaks. Prep 150 LC Config. Prep 150 LC Config. RT (minutes) Resolution RT (minutes) Resolution RT (minutes) Resolution 6.00 5.91 5.96 8.75 7. 8.6 8.5 8.6 8. 9.58.6 9.47. 9.39 1.9 1.19 5.5 1.0 4.9 1.00 5.1 6

CONCLUSIONS Analytical chromatography can be successfully scaled to preparatory chromatography easily by using a systematic approach. The use of identical column chemistry and identical column lengths maintains separation quality. Knowing and using the system volume for both the analytical and prep systems aids in error-free scale-up. References 1. Effective Use of Temperature Control in Compound Isolation, Jo-Ann M. Jablonski, Thomas E. Wheat, Diane M. Diehl. Waters Application Note, 009, Part Number: 7000954en. Developing Focused Gradients for Isolation and Purification, Jo-Ann M. Jablonski, Thomas E. Wheat, Diane M. Diehl, Waters Application Note, 009, Part Number: 7000955en The Waters Prep OBD Calculator aids in the scaling calculations. Developing methods on the analytical scale and transferring them to preparatory scale reduces solvent and sample consumption while reducing waste disposal cost compared to developing separation methods at the preparatory scale only. Waters, The Science of What s Possible, XBridge, Alliance, and Empower are registered trademarks of Waters Corporation. ChromScope and OBD are trademarks of Waters Corporation. All other trademarks are the property of their respective owners. 015 Waters Corporation. Produced in the U.S.A. July 015 70005458EN AG-PDF Waters Corporation 34 Maple Street Milford, MA 01757 U.S.A. T: 1 508 478 000 F: 1 508 87 1990 www.waters.com