Acrylamide (electrophoresis grade), AR grade captopril, L-cysteine, glutathione,

Similar documents
Supporting Information

Agilent 1290 Infinity Quaternary LC Stepwise Transfer to Methods with MS-Compatible Mobile Phases

770-9P. Sensitivity and Selectivity - A Case Study of LC/MS Enantioselective Resolution of Bupivacaine Using Vancomycin as a Chiral Stationary Phase

The Agilent InfinityLab 2D-LC Solution with Active Solvent Modulation

CHAPTER V ANALYTICAL METHODS ESTIMATION OF DICLOFENAC. Diclofenac (gift sample from M/s Micro Labs Ltd., Pondicherry)

Application Note. Author. Abstract. Food Safety. Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India

Rapid method development to study plasma stability of diverse pharmaceutical compounds using Rapid Resolution LC and triple quadrupole MS

ANALYTICAL METHOD PROCEDURES

3.1. Preparation of Buffer Solutions

Separation of Enantiomers of Amphetamine-Related Drugs and Their Structural Isomers

Self-assembly of PEGylated Gold Nanoparticles. with Satellite Structures as Seeds

Fumonisin. Fumonisin B 1 Fumonisin B 2. Fumonisin B 3. CAS No.:

A graphene oxide-based AIE biosensor with high selectivity toward bovine serum albumin

Electronic Supplementary Information

Measuring Drug-to-Antibody Ratio (DAR) for Antibody-Drug Conjugates (ADCs) with UHPLC/Q-TOF

ANALYTICAL REPORT 1. 4-Me-TMP (C15H21NO2) Remark other NPS detected: none. sample contains some impurities (benzeneacetic acid + others)

LC/MS/MS qua ntitation of β-estradiol 17-acetate using an Agilent 6460 Triple Quadrupole LC/MS working in ESI negative ion mode

Accurate Mass Analysis of Hydraulic Fracturing Waters: Identification of Polyethylene Glycol Surfactants by LC/Q-TOF-MS

In vivo monitoring of hydrogen sulfide using a cresyl violet-based ratiometric fluorescence probe

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Microdetermination of phosphorus using the SPECTRAmax PLUS microplate spectrophotometer: choice of microplate, cuvette or test tube assay formats

Oxidation of thiols to disulfides by dioxygen catalyzed by a bioinspired organocatalyst

Strikingly different miscibility of n-octanol in highly-confined and quasi-confined water

Encapsulation of enzyme in metal ion-surfactant nanocomposites for

Supplementary Figure 1. Structures of substrates tested with 1. Only one enantiomer is shown.

Ultrafast Analysis of Buprenorphine and Norbuprenorphine in Urine Using the Agilent RapidFire High-Throughput Mass Spectrometry System

Determination of an Equilibrium Constant

Developing a fast, generic method for rapid resolution LC with quadrupole MS detection. Application Note

Determination of Beta-Blockers in Urine Using Supercritical Fluid Chromatography and Mass Spectrometry

ANALYTICAL REPORT 1 1P-LSD (C23H29N3O2) N,N-diethyl-7-methyl-4-propanoyl-6,6a,8,9-tetrahydroindolo[4,3-fg]quinoline-9-

Chapter 2. Materials and Methods

16 Malachite green 17 Leucomalachite green

DEVELOPMENT OF HPLC METHOD FOR ANALYSIS OF NITRITE AND NITRATE IN VEGETABLE

The Agilent 1260 Infinity Analytical SFC System with Time-of-Flight Mass Spectrometric Detection

Analysis of Metals, Halides, and Inorganic Ions Using Hydrophilic Interaction Chromatography

Clinical Toxicology. Biomass Component Extraction: The uneaten cooked plant specimen was prepared for

Natural montmorillonite nanosheet colloid-catalyzed hydrogen peroxide

Acknowledgement: 4F-PBP (C14H18FNO) T: +386 (0) E: Vodovodna Ljubljana SLOVENIJA

CEE 684 (697K) Dichloropropanone Lab

ANALYTICAL REPORT 1 CUMYL-4CN-BINACA (C22H24N4O) 1-(4-cyanobutyl)-N-(1-methyl-1-phenylethyl)-1H-indazole-3-carboxamide

Rapid Screening and Confirmation of Melamine Residues in Milk and Its Products by Liquid Chromatography Tandem Mass Spectrometry

H 3 CO H 3 CO S CH 3

Chapter 4: Verification of compendial methods

ADVANTAME (TENTATIVE)

Determination of Carbonyl Compounds In Water by Dinitrophenylhydrazine Derivatization and HPLC/UV*

Supporting Information

Achieve confident synthesis control with the Thermo Scientific ISQ EC single quadrupole mass spectrometer

Analytical determination of testosterone in human serum using an Agilent Ultivo Triple Quadrupole LC/MS

Macrolides in Honey Using Agilent Bond Elut Plexa SPE, Poroshell 120, and LC/MS/MS

Determination of Hormones in Drinking Water by LC/MS/MS Using an Agilent InfinityLab Poroshell HPH Column (EPA 539)

Determination of Trace Cations in Power Plant Waters Containing Morpholine

Co-solvent exfoliation and suspension of hexagonal boron nitride

Analysis of Low-Calorie Sweeteners by Liquid Chromatography-Tandem Mass Spectrometry

High-Resolution Sampling 2D-LC for Pharmaceutical Impurity Analysis

ICP-OES Application Note Number 35

Supplementary information 1. INSTRUCTIONS FOR STUDENTS

CHEMISTRY. Section II (Total time 95 minutes) Part A Time 55 minutes YOU MAY USE YOUR CALCULATOR FOR PART A.

A periodic table is attached for use with the exam. You may remove it and do not need to turn it in with the exam. Score

Fast ph-assisted functionalization of silver nanoparticles with monothiolated DNA

VALIDATION OF A UPLC METHOD FOR A BENZOCAINE, BUTAMBEN, AND TETRACAINE HYDROCHLORIDE TOPICAL SOLUTION

High Sensitivity HPLC Analysis of Perchlorate in Tap Water Using an Agilent 6460 Triple Quadrupole LC/MS System

Supporting Information

Accurate Mass Analysis of Hydraulic Fracturing Waters

Accurate Mass Measurement for Intact Proteins using ESI-oa-TOF. Application Note. Donghui Yi and Christine Miller Agilent Technologies

Fast peaks in chromatograms of Sudan dyes

DETERMINATION OF DRUG RELEASE DURING DISSOLUTION OF NICORANDIL IN TABLET DOSAGE FORM BY USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

Impact factor: 3.958/ICV: 4.10 ISSN:

Volume 6, Issue 2, January February 2011; Article-015

Research Article METHOD DEVELOPMENT AND VALIDATION FOR SIMULTANEOUS ESTIMATION OF ELBASVIR AND GRAZOPREVIR BY RP-HPLC

Determination of Orthophosphate Ion

CIPAC. CIPAC Free relevant impurities methods:

BENZYLPIPERAZINE Latest Revision: June 1, 2005

Determination of Orthophosphate Ion

Fractionation of Acidic, Basic, and Neutral Drugs from Plasma with an SPE Mixed Mode Strong Cation Exchange Polymeric Resin (Agilent SampliQ SCX)

CHAPTER - 2 EXPERIMENTAL TECHNIQUE. Potassium permanganate has been used for. oxidation of many systems. Oxidations by permanganate

Analysis of Cannabinoids and Amphetamines in Serum by RRLC/Triple Quadrupole Mass Spectrometry Using a Multimode Ion Source. Application.

CEE 697K Bromide Lab

Application Note. Author. Abstract. Food Testing & Agriculture. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Analysis of Phthalates in Body Wash using Solid-Supported Liquid-Liquid Extraction

Experiment 7 Buffer Capacity & Buffer Preparation

Sodium Chloride - Analytical Standard

1-(2-METHOXYPHENYL)PIPERAZINE Latest revision: June 27, 2005

Experiment 1 (Part A): Plotting the Absorption Spectrum of Iron (II) Complex with 1,10- Phenanthroline

Supporting Information. for. Inhibition of peptide aggregation by means of

CHAPTER - 3 ANALYTICAL PROFILE. 3.1 Estimation of Drug in Pharmaceutical Formulation Estimation of Drugs

Kinetic Isotope Effects

Mass Relationships in Chemical Reactions

Quantitative Analysis of Water-Soluble B-Vitamins in Cereal Using Rapid Resolution LC/MS/MS. Application. Authors. Abstract.

Application Note. Author. Abstract. Pharmaceutical QA/QC. Siji Joseph Agilent Technologies, Inc. Bangalore, India

c. K 2 CO 3 d. (NH 4 ) 2 SO 4 Answer c

Electronic Supplementary Material (ESI) for Chemical Communications This journal is The Royal Society of Chemistry 2013

Supporting Information

Amphetamines, Phentermine, and Designer Stimulant Quantitation Using an Agilent 6430 LC/MS/MS

Department of Environmental Toxicology, University of California, Davis, California

AIM To verify Beer - Lambert s law and to determine the dissociation constant (Ka) of methyl red, Spectrophotometrically.

A near-infrared colorimetric fluorescent chemodosimeter for the detection of glutathione in living cells

Diquat 1,1 -ethylene-2,2 -bipyridium dibromide salt Paraquat 1,1 -dimethyl-4,4 -bipyridium dichloride salt Initial Preparation

Introduction to biochemical practicals. Vladimíra Kvasnicová

1. Preliminary qualitative analysis of unknown substances (liquid or solid).

Supporting Information

Transcription:

Electronic Supplementary Material (ESI) for Toxicology Research. This journal is The Royal Society of Chemistry 2014 Materials and Methods Chemicals Acrylamide (electrophoresis grade), AR grade captopril, L-cysteine, glutathione, Ellman s reagent, (ESSE), sodium chloride, Tris.HCl, potassium hydrogen phthalate, potassium dihydrogen phosphate, ascorbic acid (H 2 ASc), and HPLC grade methanol were purchased from Aldrich (Fairlawn, NJ). Deionised water was prepared in house using a Labconco Water Pro PS deionizer (Labconco Water Corporation, Kansas City, MO). All stock and working solutions were prepared in deionised water. HCl (Analar grade) was obtained from BDH Laboratories (Poole, England). Spectrophotometric Measurements The acrylamide-thiol (AA-SR) complexes were monitored spectrophotometrically on a HP 8453 Diode Array Spectrophotometer with 1 cm path length quartz cuvettes. The wavelengths monitored were 327 nm for ESSE and 409 nm for the Ellman s thiolate (ES - ) anion. The diode array spectrophotometer was operated in the kinetic mode for determination of reaction parameters and in the standard mode for quantifying the rate constants associated with each AA-thiol reaction. Temperature was maintained by a Lauda-Brinkmann RM6 B Ciculator/Thermostated Water Bath (Lauda Dr. R. Wobser, GMBH and Co., Lauda- Königshofen, Germany). In the kinetic mode, all reactions were conducted at 310 K. In the standard mode with varied AA concentrations, the reactions were conducted at 310 K. For varied thiol concentrations, the reactions were conducted at 293, 298, 303 K for CySH and 303, 310, and 315 K for CapSH and GSH. Mixtures containing CapSH and GSH were measured at 1 minute

intervals while CySH mixtures were measured at 30 s intervals. The ph of the final solutions were recorded using an Orion Research Expandable ion Analyzer EA 920 (Orion Research Inc., Boston, M.A., U.S.A.) calibrated with buffers: 4.01 (0.0496 mol dm -3 K 2 HC 8 H 4 O 4 ) and 6.87 (0.025 mol dm -3 KH 2 PO 4 ). LC/DAD/MS Analysis The AA SR complexes were analyzed on an Agilent 1100 Series LC coupled to an Agilent 1100 Series MS Detector (Agilent, Technologies, Palo Alto, CA, U.S.A.). Separation of the complexes were achieved using a Zorbax Eclipse XDB C18 column (150 mm x 4.6 mm ID x 5 µm particle size; Agilent Technologies, Palo Alto, CA, U.S.A.) with a Zorbax XDB C18 guard column (12.5 mm x 4.6 mm i.d.) at a flow rate of 0.2 ml/min; Operating parameters were: positive electrospray ionization (+ESI) in the SIM and scan modes; SIM ions: 308, 379, 380, 613; scan range: 300 400 amu (for the AA SG complex); Mobile phase: methanol/water (5 + 95 v/v)%; run time 8.00 min; MS: Drying gas temperature: 350 o C; drying gas flow: 12 L/min; nebulizer gas pressure: 35 psig; capillary voltage: 3000 V.; Fragmentor voltage: 80V (scan), 70V (SIM); DAD: 195 ± 10 nm with a reference of 360 ± 100 nm. Preparation of Thiol Solutions Preliminary Studies Stability of Thiols Solutions of CapSH, CySH, and GSH, were all prepared at concentrations of 6.5 x 10-4 mol dm -3 in deionised water. 1.00 ml of each thiol solution was transferred to 10.00 ml volumetric flasks containing Tris/HCl buffer solutions (ph 7.4; ionic strength (I) = 0.2 mol dm -3 (NaCl)) or HCl (ph 4.5; I = 0.2 mol dm -3 (NaCl)) and made up to the mark with deionised water for a final thiol concentration of 6.5 x 10-5 mol dm -3.

A 1.0 x 10-4 mol dm -3 stock solution of ESSE was prepared in deionised water. 1.00 ml of each of the buffered thiol solutions and 1.00 ml of ESSE were mixed in 1 cm quartz cuvettes. The reactions were monitored spectrophotometically in the kinetic mode at 310 K at a cycle time of 10 s for 9000 s. Variation of Acrylamide Concentration 1.00 ml of each thiol solution was transferred to 10.00 ml volumetric flasks containing Tris/HCl buffer solutions (ph 7.4; I = 0.2 mol dm -3 (NaCl)). A 1.0 mol dm -3 AA solution was prepared in deionised water and various amounts added to the buffer solutions for final AA concentrations ranging from 9.963 x 10-3 mol dm -3 to 9.963 x 10-2 mol dm -3 i.e. pseudo-first order conditions with respect to AA. 1.00 ml of each of the thiol buffer solutions and 1.00 ml of 1.0 x 10-4 mol dm -3 ESSE were added to quartz cuvettes at various times to measure the rate of thiol decomposition. Variation of Thiol Concentration Varying volumes of each thiol stock solution were added to 10.00 ml volumetric flasks containing Tris/HCl buffer solutions (ph 7.4; I = 0.2 mol dm -3 (NaCl)) to give final thiol concentrations within the range of 1.0 x 10-5 mol dm -3 to 1.0 x 10-4 mol dm -3. The AA concentration was kept constant for each thiol. The AA concentration used for CapSH was 4.986 x 10-2 mol dm -3 and 9.963 x 10-3 mol dm -3 for both CySH and GSH. 1.00 ml of each of the thiol solutions and 1.00 ml of ESSE solution were added to quartz cuvettes at 30 s and 1 min intervals as described in Preliminary Studies. The reactions were monitored in the standard mode at a temperature at 310 K and the pseudo-first order rate constants, k obs, for the thiol

decomposition were calculated. Variable Temperature Studies Values of k obs, for each thiol were determined at three temperatures while varying the ph of the mixtures. The ph range used was 7.10 9.10 (Tris/HCl buffer). The ionic strength was kept constant at 0.2 mol dm -3 (NaCl). Thiol concentration was kept at 6.5 x 10-5 mol dm -3, and the AA concentration was also kept constant for each thiol. The AA concentration used for CapSH, CySH, and GSH were: 4.986 x 10-2 mol dm -3, 9.963 x 10-3 mol dm -3, and 1.993 x 10-2 mol dm -3, respectively. GSH and CapSH solutions were monitored at 303, 310, and 315 K while CySH solutions were monitored at 293, 298, and 303 K. Statistical Analysis of Data The pseudo-first order rate constants, k obs, for the thiol decomposition were calculated from absorbance time data using the StatGraphics Centurion XV.I Software (SGS). k obs values at each temperature were used to calculate the specific rate constants, k, and the pk s for each thiol. Activation parameters, ΔH, ΔS, ΔG for each thiol were calculated from Eyring plots. Parameters generated from the Eyring plots were used to construct an isokinetic plot. Computational Studies Gas phase (1 atm) geometries and energies were optimized using the BVP86 DFT functional 1 and Ahlrichs TZVP basis set 2 as available in the PQS programme 3. Transition state geometries were optimized until a single imaginary vibrational frequency corresponding to displacement along the intrinsic reaction coordinate was found. The energy differences between

reactants, transition states and products were computed relative to that of the combined energy of the isolated reactants in each case. Energy partition function analysis was used to determine the thermal corrections to the energy of each molecule (enthalpic and entropic) at different temperatures from translational, rotational and vibrational modes. With water as solvent, energies and optimized geometries were computed using the COSMO 4 electrostatic screening model and the output transferred to the ADF 5 programme for COSMO-RS 6 calculations at infinite dilution. References 1. A. D. Becke, Phys Rev A, 1988, 38, 3098-3100. 2. A. Schafer, H. Horn and R. Ahlrichs, J. Chem. Phys., 1992, 97, 2571-2577. 3. J. Baker, T. Janowski, K. Wolinski and P. Pulay, WIREs Comput. Mol. Sci., 2012, 2, 63-72. 4. A. Klamt, J. Phys. Chem., 1995, 99, 2224-2235 5. A. Vrije Universiteit, The Netherlands. 6. C. C. Pye, T. Ziegler, E. van Lenthe and J. N. Louwen, Can. J. Chem., 2009, 87, 790-797.