A Guide to Recording Fluorescence Quantum Yields

Similar documents
Study of absorption and re-emission processes in a ternary liquid scintillation system *

DETERMINATION OF RELATIVE FLUORESCENCE QUANTUM YIELD USING THE AGILENT CARY ECLIPSE

Characterisation of Luminescent Down-Shifting Materials for the Enhancement of Solar Cell Efficiency

Singlet. Fluorescence Spectroscopy * LUMO

Chapter 15 Molecular Luminescence Spectrometry

A Fluorometric Analysis of Quinine in Tonic Water

Chem 310 rd. 3 Homework Set Answers

Supplementary information for. Observation of photovoltaic action from photoacid-modified Nafion due to light-driven ion transport

single-molecule fluorescence resonance energy transfer

27-1 (a) Resonance fluorescence is observed when excited atoms emit radiation of the same

Reflection = EM strikes a boundary between two media differing in η and bounces back

Department of Chemistry Physical Chemistry Göteborg University

Spectroscopy. Page 1 of 8 L.Pillay (2012)

Solution reduction synthesis of amine terminated carbon quantum dots

FLS980 Series Reference Guide

LABORATORY OF ELEMENTARY BIOPHYSICS

Experiment. Quantification of Ascorbic acid by Fluorescence Spectroscopy1

Supplementary Methods: Determination of the spectral

Molecular Luminescence Spectroscopy

SUPPORTING INFORMATION

Chapter 11. Basics in spin-orbit couplings

Photoinduced Guest Transformation Promotes Translocation of Guest from Hydroxypropyl-β-Cyclodextrin to Cucurbit[7]uril

Supporting Information

S2. INTRODUCTION TO ULTRA-VIOLET / VISIBLE SPECTROSCOPY

FLUORESCENCE APPLICATIONS

INTRODUCTION The fundamental law of spectrophotometry is known as the Beer-Lambert Law or Beer s Law. It may be stated as: log(po/p) = A

A Fluorometric Analysis of Quinine in Tonic Water

What the Einstein Relations Tell Us

Chemistry 524--Final Exam--Keiderling May 4, :30 -?? pm SES

C101-E145 TALK LETTER. Vol. 17

Chem Homework Set Answers

Chapter 6 Photoluminescence Spectroscopy

CHEM Outline (Part 15) - Luminescence 2013

Detection of toxic mercury ions using a ratiometric CdSe/ZnS nanocrystal sensor

Complete the following. Clearly mark your answers. YOU MUST SHOW YOUR WORK TO RECEIVE CREDIT.

LAB #3: FLUROESCENCE SPECTROSCOPY AND ELECTRON TRANSFER (This lab is adapted from the U of MN Phsyical Chemistry lab manual)

Supporting Information

Facile bulk production of highly blue fluorescent

Lab 11: Must what goes in be the same as what comes out? Spectroscopy & Fluorescence in Chlorophyll.

1 WHAT IS SPECTROSCOPY?

1. Photoreduction of Benzophenone in 2-Propanol

Fluorescence Workshop UMN Physics June 8-10, 2006 Basic Spectroscopic Principles Joachim Mueller

Experiment #9. Atomic Emission Spectroscopy

6. A solution of red Kool-Aid transmits light at a wavelength range of nm.

CHAPTER 5 SPECTRAL CHARACTERISTICS OF NONLINEAR DYES IN LIQUID MEDIUM

UV-Vis optical fiber assisted spectroscopy in thin films and solutions

Chemistry 2. Molecular Photophysics

Energy transfer and optical gain studies of FDS: Rh B dye mixture investigated under CW laser excitation

Determining Riboflavin Content in a Multivitamin: Things to do before the lab

Physical Chemistry Advanced laboratory course. Excimer formation

A Determination of DNA-DAPI Binding using Fluorescence Spectroscopy

CD Basis Set of Spectra that is used is that derived from comparing the spectra of globular proteins whose secondary structures are known from X-ray

Measurement Examples. Excitation and Emission Scans. Steady State Fluorescence Anisotropy. Kinetic Measurements

Basics of UV-Visible Spectroscopy *

Wavelength λ Velocity v. Electric Field Strength Amplitude A. Time t or Distance x time for 1 λ to pass fixed point. # of λ passing per s ν= 1 p

Fluorescence (Notes 16)

A Fluorescence Turn-On Sensor for the Detection of Palladium Ions that Operates Through In-Situ Generation of Palladium Nanoparticles

Photoperoxidation of a Diamino Zinc Porphyrazine to the seco-zinc Porphyrazine: Suicide or Murder?

Cyanine Dyes as Ratiometric Fluorescence Standards for the Far-Red Spectral Region

Design and Development of a Smartphone Based Visible Spectrophotometer for Analytical Applications

Reflection = EM strikes a boundary between two media differing in η and bounces back

PHOTOCHEMISTRY NOTES - 1 -

Ultraviolet-Visible and Infrared Spectrophotometry

Identification of ultrafast processes in ZnPc by pump-probe spectroscopy

Spectroscopy II Introduction: Spectrophotometry and Fluorometry

Introduction ENERGY. Heat Electricity Electromagnetic irradiation (light)

Electronic Spectra of Complexes

R O Y G B V. Spin States. Outer Shell Electrons. Molecular Rotations. Inner Shell Electrons. Molecular Vibrations. Nuclear Transitions

Supporting Information for. Metallonaphthalocyanines as Triplet Sensitizers for Near-Infrared. Photon Upconversion beyond 850 nm

ELECTRONIC SUPPLEMENTARY INFORMATION (ESI) variable light emission created via direct ultrasonic exfoliation of

Chemistry Instrumental Analysis Lecture 5. Chem 4631

Raman spectroscopy of phthalocyanines and their sulfonated derivatives

Triaryl Amine N-Functionalised 2,7-Linked Carbazole Polymers as a. New Class of Blue Emitting Materials for LED Applications

The Hydrogen Spectrum

Absorption, Emission and Fluorescence Spectroscopies. R. Corn - Chem M3LC

Lecture 5. Anisotropy decay/data analysis. Enrico Gratton

FLUORESCENCE QUANTUM YIELDS OF SOME RHODAMINE DYES

Traceable UV-Vis Reference Materials

PART VI : MOLECULAR LUMINESCENCE SPECTROSCOPY (Recommendations 1985)

Absorption, Emission and Fluorescence Spectroscopies. Chem M3LC. R. Corn

Energy. Position, x 0 L. Spectroscopy and the Particle-in-a-Box. Introduction

Theoretical Model for the Effect of Temperature on the Fluorescence Spectrum of Laser Dye (Rh6G) in Acetone

Data Quality and Post Processing

CHEM*3440. Photon Energy Units. Spectrum of Electromagnetic Radiation. Chemical Instrumentation. Spectroscopic Experimental Concept.

Photoluminescence enhancement of carbon dots by gold. nanoparticles conjugated via PAMAM dendrimers

Supporting Information

A. K. R. Junker et al 1 Investigating subtle 4f vs. 5f...

Chapter 4 Ultraviolet and visible spectroscopy Molecular Spectrophotometry

The photoluminescent graphene oxide serves as an acceptor rather. than a donor in the fluorescence resonance energy transfer pair of

Chem 454 instrumental Analysis Exam 1 February 6 th, 2008

A Characterization of Small Molecule and Polymer Dyes for Use in Luminescent Solar Concentrators

AS 101: Day Lab #2 Summer Spectroscopy

Fluorescence Workshop UMN Physics June 8-10, 2006 Quantum Yield and Polarization (1) Joachim Mueller

Electronic Supporting Information (ESI)

Introduction. Molecules, Light and Natural Dyes. Experiment

Reference literature. (See: CHEM 2470 notes, Module 8 Textbook 6th ed., Chapters )

Chapter 17: Fundamentals of Spectrophotometry

Supporting Information

College of Chemistry and Chemical Engineering, Shenzhen University, Shenzheng, Guangdong, P. R. China. 2

Atomic Emission and Molecular Absorption Spectra

Transcription:

Oa~äëíçåd~êÇÉåëIpí~åãçêÉIjáÇÇäÉëÉñe^TN_nIrh A Guide to Recording Fluorescence Quantum Yields Introduction: When a fluorophore absorbs a photon of light, an energetically excited state is formed. The fate of this species is varied, depending upon the exact nature of the fluorophore and its surroundings, but the end result is deactivation (loss of energy) and return to the ground state. The main deactivation processes which occur are fluorescence (loss of energy by emission of a photon), internal conversion and vibrational relaxation (non radiative loss of energy as heat to the surroundings), and intersystem crossing to the triplet manifold and subsequent non radiative deactivation. The fluorescence quantum yield (ΦF) is the ratio of photons absorbed to photons emitted through fluorescence. In other words the quantum yield gives the probability of the excited state being deactivated by fluorescence rather than by another, non radiative mechanism. The most reliable method for recording ΦF is the comparative method of Williams et al.,1 which involves the use of well characterised standard samples with known ΦF values. Essentially, solutions of the standard and test samples with identical absorbance at the same excitation wavelength can be assumed to be absorbing the same number of photons. Hence, a simple ratio of the integrated fluorescence intensities of the two solutions (recorded under identical conditions) will yield the ratio of the quantum yield values. Since ΦF for the standard sample is known, it is trivial to calculate the ΦF for the test sample. In practice, the measurement is slightly more complicated than this because it must take into account a number of considerations. For example: The presence of concentration effects, e.g. self quenching; The use of different solvents for standard and test samples; The validity in using the standard sample and its ΦF value. These considerations are answered by Working within a carefully chosen concentration range and acquiring data at a number of different absorbances (i.e. concentrations) and ensuring linearity across the concentration range; Including the solvent refractive indices within the ratio calculation; Cross calibrating the standard sample with another, to ensure both are behaving as expected and allowing their ΦF values to be used with confidence. The measurement of ΦF values is challenging if the values are to be trusted. Incorrect quantum yields are all too easy to obtain!

Oa~äëíçåd~êÇÉåëIpí~åãçêÉIjáÇÇäÉëÉñe^TN_nIrh General Experimental Considerations: Standard samples. The standard samples should be chosen to ensure they absorb at the excitation wavelength of choice for the test sample, and, if possible, emit in a similar region to the test sample. The standard samples must be well characterised and suitable for such use. A number of lists of good fluorescent standard samples are available, including: J. R. Lakowicz, Principles of Fluorescence Spectroscopy, Kluwer Academic/Plenum Press, New York, 1999, Second Edition. J. C. Scaiano (Ed.), Handbook of Organic Photochemistry, CRC Press, 1989. A list of standard samples, with their literature quantum yields, is given at the end of this document. Cuvettes. Standard 10 mm path length fluorescence cuvettes are sufficient for running the fluorescence measurements. In order to minimise errors in calculating the absorbance of each solution, it is advisable to use absorption cuvettes with extended path lengths (for example, 20 mm, 50 mm). Concentration range. In order to minimise re absorption effects (Dhami et al.2) absorbances in the 10 mm fluorescence cuvette should never exceed 0.1 at and above the excitation wavelength. Above this level, non linear effects may be observed due to inner filter effects, and the resulting quantum yield values may be perturbed. Remember that this maximum allowable value of the recorded absorbance must be adjusted depending upon the path length of the absorption cuvette being used (for example, 10 mm 0.1 maximum, 20 mm 0.2 maximum etc). Sample preparation. It is vital that all glassware is kept scrupulously clean, and solvents must be of spectroscopic grade and checked for background fluorescence. Procedure: 1. Record the UV vis absorbance spectrum of the solvent background for the chosen sample. Note down the absorbance at the excitation wavelength to be used. 2. Record the fluorescence spectrum of the same solution in the 10 mm fluorescence cuvette. Calculate and note down the integrated fluorescence intensity (that is, the area of the fluorescence spectrum) from the fully corrected fluorescence spectrum. 3. Repeat steps 1. and 2. for five solutions with increasing concentrations of the chosen sample. (There will be six solutions in all, corresponding to absorbances at the excitation wavelength of ~0/solvent blank, 0.02, 0.04, 0.06, 0.08 and 0.10.) 4. Plot a graph of integrated fluorescence intensity vs absorbance. The result should be a straight line with gradient m, and intercept 0. 5. Repeat steps 1. to 4. for the remaining samples.

Oa~äëíçåd~êÇÉåëIpí~åãçêÉIjáÇÇäÉëÉñe^TN_nIrh Figure 1: Example of an absorption and emission data set obtained for five different concentrations of a sample. Note that the absorption measurements have been recorded with a 50 mm path length cuvette, and have not been background corrected the solvent blank absorption is shown in the figure. Note that all the fluorescence spectra must be recorded with constant slit widths. Changing this parameter between samples will invalidate the quantum yield measurement. Ideally the band pass of the excitation monochromator should be set to the same value as the UV vis absorbance spectrometer used for the absorbance measurements, although so long as the difference between the two is not excessive the success of the measurement will not be compromised. Another approach to this, when using the Jobin Yvon spectrofluorometers (FluoroLog and FluoroMax), is the in situ measurement of optical transmission through the sample whilst in the fluorometer sample chamber, by use of the transmission accessory. However, this does remove the opportunity of using long path length absorbance cells for increased accuracy, and whilst speeding up the acquisition process, may not be suitable for more difficult measurements. Although the above methodology does require the use of a single excitation wavelength throughout the quantum yield measurements, when using the Jobin Yvon FluoroLog and FluoroMax systems the use of different excitation wavelengths for specific samples is possible. In this case, the data must be corrected for the changes in excitation intensity, by dividing the spectrally corrected emission data by the spectrally corrected excitation intensity, corresponding to Sc/Rc. However, the practice of maintaining just one excitation wavelength for all samples will reduce the chance for errors in the inherently difficult quantum yield measurement.

Oa~äëíçåd~êÇÉåëIpí~åãçêÉIjáÇÇäÉëÉñe^TN_nIrh Calculation of Fluorescence Quantum Yields from Acquired Data: The gradients of the graphs obtained in 4. above are proportional to the quantum yield of the different samples. Absolute values are calculated using the standard samples which have a fixed and known fluorescence quantum yield value, according to the following equation: Where the subscripts ST and X denote standard and test respectively, Φ is the fluorescence quantum yield, Grad the gradient from the plot of integrated fluorescence intensity vs absorbance, and η the refractive index of the solvent. Figure 2: linear plots for two standard samples. The gradient for each sample is proportional to that sample s fluorescence quantum yield. Conversion into an absolute quantum yield is achieved through the equation given in the text. First, the two standard compounds are cross calibrated using this equation. This is achieved by calculating the quantum yield of each standard sample relative to the other. For example, if the two standard samples are labelled A and B, initially A is treated as the standard (ST) and B as the test sample (X), and the known ΦF for A is used. Following this, the process is reversed, such that B is now treated as the standard (ST) and A becomes the test sample (X). In this manner, the quantum yields of A and B are calculated relative to B and A respectively. The values of ΦF(A) and ΦF(B) obtained by experiment in this way should match the literature values. The match is generally considered valid and acceptable if the data obtained is of good quality (i.e., good linearity with a zero intercept) and the experimental quantum yields match their literature counterparts within ±10%. If the values show a larger error than this, fresh standard solutions should be prepared, and the process repeated. Possible reasons for a poor match include contamination or degradation of the samples or inaccurate spectral correction of the spectrofluorimeter.

Oa~äëíçåd~êÇÉåëIpí~åãçêÉIjáÇÇäÉëÉñe^TN_nIrh Once the standard samples have been cross calibrated and an acceptable match obtained, the quantum yield values for the test samples can then be calculated, using the same equation above. For each test sample, two ΦF values will be obtained, one relative to standard A, the other to standard B. The simple average of these two values represents the quantum yield of the test sample. The error in the reported value must be considered based upon the observed errors in the gradients; a value of ±10% is normal. Planning: As can be seen above, the measurement of fluorescence quantum yields is laborious and time consuming. Nonetheless, with careful planning the process can be made as efficient as possible. For example, there is no point in performing all measurements until the standard samples have been cross calibrated (a long day s work recording data for two standard samples and six test samples may come to nothing if, at the end of the day, analysis of the two standard samples shows an unacceptable match). Take measurements for the standard samples only, and check their cross calibration is acceptable before moving on to record data for the remaining test samples. Conclusions: The measurement of fluorescence quantum yields can often be difficult and troublesome, and the need for absolute care during every step cannot be over emphasised. However, it is possible to make such measurements routinely, and following these guidelines should make this an achievable goal. Acknowledgements: Dr Andy Beeby at the Department of Chemistry, University of Durham, U.K. is thanked for providing data and for useful discussions concerning this methodology. References: 1) A. T. R. Williams, S. A. Winfield and J. N. Miller, Relative fluorescence quantum yields using a computer controlled luminescence spectrometer, Analyst, 1983, 108, 1067. 2) S. Dhami, A. J. de Mello, G. Rumbles, S. M. Bishop, D. Phillips and A. Beeby, Phthalocyanine fluorescence at high concentration: dimers or reabsorption effect? Photochem. Photobiol., 1995, 61, 341.

Oa~äëíçåd~êÇÉåëIpí~åãçêÉIjáÇÇäÉëÉñe^TN_nIrh A Table of Standard Materials and Their Literature Quantum Yield Values Compound Solvent Literature Quantum Emission Reference yield range / nm Cresyl violet Methanol 0.54 600 650 J. Phys. Chem., 1979, 83, 696 Rhodamine 101 Ethanol + 0.01% HCl 1.00 600 650 J. Phys. Chem., 1980, 84, 1871 Quinine sulfate 0.1M H2SO4 0.54 400 600 J. Phys. Chem., 1961, 65, 229 Fluorescein 0.1M NaOH 0.79 500 600 J. Am. Chem. Soc., 1945, 1099 Norharmane 0.1M H2SO4 0.58 400 550 J. Lumin., 1992, 51, Harmane 0.1M H2SO4 0.83 400 550 J. Lumin., 1992, 51, Harmine 0.1M H2SO4 0.45 400 550 J. Lumin., 1992, 51, 2 methylharmane 0.1M H2SO4 0.45 400 550 J. Lumin., 1992, 51, Chlorophyll A Ether 0.32 600 750 Trans. Faraday Soc., 1957, 53, 646 55 Zinc phthalocyanine 1% pyridine in toluene 0.30 660 750 J. Chem. Phys., 1971, 55, 4131 Benzene Cyclohexane 0.05 270 300 J. Phys. Chem., 1968, 72, 325 Tryptophan Water, ph 7.2, 25C 0.14 300 380 J. Phys. Chem., 1970, 74, 4480 2 Aminopyridine 0.1M H2SO4 0.60 315 480 J. Phys. Chem., 1968, 72, 2680 Anthracene Ethanol 0.27 360 480 J. Phys. Chem., 1961, 65, 229 9,10 diphenyl anthracene Cyclohexane 0.90 400 500 J. Phys. Chem., 1983, 87, 83