Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Similar documents
Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur

Combustion Ion Chromatography. Fast and reliable determination of halogens and sulfur using pyrohydrolysis

Analysis of various clays with Metrohm Combustion IC

Air Monitoring. Semi-continuous determination of ambient air quality

881 Compact IC pro 882 Compact IC plus. Compact ion chromatography for intelligent, reliable and precise analysis

881 Compact IC pro / 882 Compact IC plus for ion chromatography. Intelligent. Reliable. Precise.

Suppression in anion chromatography. More sensitive analysis of anions and organic acids

883 Basic IC plus. The smallest Metrohm ion chromatograph

Anion and Cation analysis with Professional IC - automatic dilution and sample preparation with SPM

861 Advanced Compact IC

Ion chromatography. Ion chromatography

Metrohm Inline Sample Preparation. Ion chromatography analyses could not be easier

Accurate and Reproducible Determination of Organic Halogens Using Combustion Ion Chromatography

Determination of chlorine, bromine, and sulfur in polyethylene materials using combustion IC with a carbonate/bicarbonate eluent

DETERMINATION OF TOTAL HALOGEN CONTENT IN HALOGEN-FREE FLUXES BY INDUCTIVELY COUPLED PLASMA AND SOME LIMITATIONS OF ION CHROMATOGRAPHY

Cyanide and sulfide analysis using amperometric detection and Metrosep A Supp /4.0

Metrohm Inline Sample Preparation. Making your ion chromatography more efficient

Intelligent Ion Chromatography. 850 Professional IC 872 Extension Module 858 Professional Sample Processor

Determination of Adsorbable Organic Halogen in Wastewater

Mobile coulometer for water determination anywhere you want

novaa 800 D Atomic Absorption Spectrometer

Automation in ion chromatography. Save time and money through automated sample preparation and analysis

Determination of Chloride, Fluoride, Bromide, Nitrate, Sulphate and Phosphate in Water Sample...

ION CHROMATOGRAPHY SYSTEM S 150

Characterization of Polymers and Plastics (pellets, powders and films) by the Thermo Scientific FLASH 2000 Elemental Analyzer

Burning Through the Confusion: See How Combustion IC Provides Superior Halide Analysis

Automation in ion chromatography. Save time and money through automated sample preparation and analysis

Innovative. Intuitive. Concentration (ppb) R = Versatile. Hydra II C Mercury Analyzer

Theory of Ion Chromatography

Ion Analysis of Hydraulic Fluids in Fracking Process

Hydra-C Application Note: 1076

Basic Digestion Principles

Mira Metrohm Instant Raman Analyzer. Always ready to measure

ECS8020 ORGANIC ELEMENTAL ANALYZER CHNS-O Analyzer

Chemical Analysis. Low Level Oxygenates Analyzer. Trace Analysis of Oxygenates in Hydrocarbon Matrices. Gas Chromatography.

110 Lowell Rd Hudson, NH USA Tel:

The art of elemental analysis

Compact Titration. Compact Titrator G20. One Click Titration Simple & Dependable

Elemental Analysis: CHNS/O characterization of polymers and plastics

ERALY SERVOCOULOMETRE MIPO5: DETERMINATION OF CHLORINE AND BROMINE

Chemical Analysis. PIONA+ Analyzer. Characterization of Engine Fuels by Hydrocarbon Group Type. Gas Chromatography. think forward

Chromatography. Gas Chromatography

OXITEST Oxidation Test Reactor

Application Note S/SL

Sulfur speciation in mining leachates by ion exchange with direct UV detection, using a perchlorate mobile phase.

3. Chemical industry. Because of their modular design, the instruments in the TOC-L series can be equipped for any possible measurement

Accurate and Precise Sulfur Analysis using the Thermo Scientific FlashSmart Elemental Analyzer

Product Descriptions and Offerings

costech instruments ECS 4010 Elemental Combustion System CHNS-O

Atomic Absorption Spectrometer ZEEnit P series

TYPES OF CHEMICAL REACTIONS

Maintenance with OQ. ZEEnit 700. Operational Qualification OQ within the scope of a maintenance for the. Atomic Absorption Spectrometer

Automatic determination of the bromine number and the bromine index in petroleum products

Analysis of Trace (mg/kg) Thiophene in Benzene Using Two-Dimensional Gas Chromatography and Flame Ionization Detection Application

Enhancing the productivity of food sample analysis with the Agilent 7700x ICP-MS

2Fe 2 O 3 +3H 2 S FeS+FeS x +S+3H 2 O

Ion Analysis of Hydraulic Fluids in Fracking Process

Method for Nitrite determination on Low-Range Samples

columns IonPac AS17-C Anion Exchange Column

Chlorinated Compounds in Hydrocarbon Streams Using a Halogen Specific Detector (XSD)

Making Improvements to Today s Natural Gas Analysis Systems

NON-METHANE ORGANIC CARBON ANALYZER (NMOC Method 25)

Dionex IonPac AS28-Fast-4µm column

Gas Chromatography (GC)! Environmental Organic Chemistry CEE-PUBH Analysis Topic 5

Petrochemical. Transformer Oil Gas Analysis - TOGA

Finnigan TC/EA. High Temperature Conversion Elemental Analyzer

Thermo Scientific ConFlo IV Universal Interface. Continuous Flow Interface. Isotope Ratio MS

Technical Procedure for Concentration Determination of Methamphetamine in Liquids via HPLC

White Paper. Overview: NDIR Definition:

Mole Conversions Worksheet

Chromatographic Methods of Analysis Section: 5 Gas Chromatography (GC) Prof. Tarek A. Fayed

The Elzone II Particle Count and Size Analyzer

Chapter 31 Gas Chromatography. Carrier Gas System

2035 Process Analyzer. Customized online monitoring of industrial processes and wastewater

FEATURE ARTICLE. The CS-100 Series High-precision Chemical Solution Monitor in the Semiconductor Cleaning Process. Takaaki Yada.

Pros and Cons of Water Analysis Methods

Chemical formula - tells you how many atoms of each element are in a compound example: CO 2 (carbon dioxide) has one carbon atom and two oxygen atoms

Chemical Reactions CHAPTER Reactions and Equations

Exploring the Benefits of Automated Unattended Sample Derivatization Prior to Gas Chromatography Analysis

Thermal Analysis Premium

GUIDELINES FOR THE DESIGN OF CHROMATOGRAPHIC ANALYTICAL METHODS INTENDED FOR CIPAC COLLABORATIVE STUDY

High-Speed Environmental Analysis Using the Agilent 7500cx with Integrated Sample Introduction System Discrete Sampling (ISIS DS)

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB5009.

VUV ANALYTICS VGA-100 GC DETECTOR Gas Chromatograph Agilent 6890 equipped with a 7683 model autosampler Restek 30m x 0.25mm x 0.

Application Note. Author. Abstract. Pharmaceutical QA/QC. Vinayak A.K Agilent Technologies Bangalore, India

YEAR 10- Chemistry Term 1 plan

Oxidation-Reduction Reactions

Ch 9 Stoichiometry Practice Test

Application Note. An Optimum Solution for the Automatic Control of Cutting Oils

Using a Reagent-Free ion chromatography system to monitor trace anion contamination in the extracts of electronic components

Compact Titration Compact Titrator G20. One Click Titration Simple & Dependable

HPLC Praktikum Skript

Application Bulletin

Problems with the measurement of NH 4 with Ion Chromatography

M06/4/CHEMI/HP3/ENG/TZ0/XX CHEMISTRY HIGHER LEVEL PAPER 3. Candidate session number 0 0. Friday 19 May 2006 (morning) 1 hour 15 minutes

Evolution of the Halogen Free concept in the world. Framework regulatory and influence in the local market. Santiago de Chile 30/06/2018

Cambridge IGCSE Chemistry. Topic 5: Electricity and chemistry. Notes.

THE UNITED REPUBLIC OF TANZANIA MINISTRY OF EDUCATION AND CULTURE FORM TWO SECONDARY EDUCATION EXAMINATIONS INSTRUCTIONS

Total sulphur content

859 Titrotherm. Thermometric titration the ideal complement to potentiometric titration

Transcription:

Combustion Ion Chromatography Fast and reliable determination of halogens and sulfur

Combustion digestion and ion chromatography combined in one system 02 Combustion Ion Chromatography (CIC) extends the range of ion chromatography to all types of combustible samples. The focus here is primarily on the simul taneous de ter mination of the various halogens and sulfur in wi dely differing matrices. Metrohm s CIC System, including sample preparation, is completely automated. CIC is superior to offline digestion methods with regard to sample throughput on the one hand and precision and correctness of the results on the other. With CIC, unlike with alternative methods, the concentrations of the different halogens can each be de termined separately. The principle In CIC the samples are first digested under an argon at mosphere in the oven unit and then burnt with oxygen. In the 920 Absorber Module, the resulting gaseous compounds are passed into an absorption solution, which is then transferred inline to a Metrohm ion chromatography system, where it is analyzed. Schematic representation of a complete Combustion IC system Configuration with an 881 Compact IC pro Anions - MCS, a 920 Absorber Module and a Combustion Module from Analytik Jena equipped with solid autosampler

The advantages of CIC at a glance Extended range of application of IC for all kinds of combustible samples Simultaneous determination of sulfur and halogens Quantification of the concentration for each halogen Ideal for checking the latest analytical standards with regard to halogen-free products (RoHS, WEEE...) High sample throughput High precision and accuracy MagIC Net TM ion chromatography software for control and data management all information in one sample table or report Flame sensor ensures optimum combustion time with an universal method FDA and GLP standards are met Calibration with just one standard thanks to Metrohm intelligent Partial Loop Injection Technique (MiPT) Completely automated sample preparation for solid and liquid samples with just one modular sample changer 03

04 Applications CIC is ideal for routine analysis in a variety of fields, as it requires neither specific prior knowledge about the sample matrix nor complicated method development. Not only is CIC recommended for quality control of raw materials, intermediates and finished products; the method is also suitable for easy and exact monitoring of compliance with the relevant laws, standards and regulatory requirements in the environmental field (e.g. DIN EN 228, IEC 60502-1, RoHS, WEEE,...). Examples of areas and products where ion chromatographic analyses are possible with CIC are: environmentally relevant substances (oil, plastic waste, glass, activated carbon,...) electronic components (printed circuit boards, resin, cables, insulation,...) fuels (gasoline, kerosene, crude oil, heating oil, coal, catalysts,...) plastics (polymers such as polyethylene, polypropylene,...) coloring agents (pigments, paints,...) pharmaceutical products (raw substances, intermediates, finished products,...) foods (oils, spices, flavorings and fragrances,...) Conductivity [µs/cm] 5.5 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 chloride bromide sulfate Conductivity [µs/cm] 180 160 140 120 100 80 60 40 1.6 0.8 chloride 0.0 0 2 14 sulfate 0.5 20 0.0 0 2 4 6 8 10 12 14 16 18 Time [min] 20 0 0 2 4 6 8 10 12 14 16 18 20 Time [min] Determination of halogens and sulfur in certifi ed polyethylene pellets ERM-EC681k: chloride: 102.4%, bromide 95.4%, sulfur 100.3%. Injection volume 20 µl Determination of halogens and sulfur in coal reference material NIST 2682b: chloride: 103.4%, sulfur 96.8%. Injection volume 100 µl Conditions (both analyses): Metrosep A Supp 5-150/4.0; eluent: 3.2 mmol/l Na 2 CO 3, 1.0 mmol/l NaHCO 3, 0.7 ml/min; column temperature 30 C; oven temperature 1050 C; absorption solution: 100 mg/l H 2 O 2 Metrohm CIC complies with the following standards ASTM D7359-08 Standard Test Method for Total Fluo rine, Chlorine and Sul fur in Aromatic Hydro carbons and Their Mixtures by Oxidative Pyrohydrolytic Combustion followed by Ion Chromatography Detection (Combustion Ion Chroma to graphy CIC) UOP991-11 Chloride, Fluoride, and Bromide in Liquid Or ganics by Com bustion Ion Chromato graphy (CIC) ASTM D5987-96(2007) Standard Test Method for Total Fluorine in Coal and Coke by Pyrohydrolytic Ex traction and Ion Selective Electrode or Ion Chromatograph Methods

05 A flame sensor measures the intensity of light in the Combustion Module and controls the combustion digestion automatically. Combustion digestion controlled automatically Metrohm s new CIC consists of a Combustion Module from Analytik Jena and an absorption and IC part from Metrohm. In the Combustion Module the sample digestion is controlled automatically. The principle is simple. An optical fiber carries the light emitted during combustion from the pyrolysis oven to an optical sensor. The optical sensor measures the intensity of the light and controls the feed rate of the sample boat into the oven in proportion to it. As a result, the duration of the com bustion is optimized so that, firstly, combustion is always complete (no soot formation), and, secondly, there is no need for waiting times as a safety buffer. Thanks to the automated control of sample digestion, method development for combustion is not needed both different samples and different sample quantities can be treated with using the same universal «method». Sample changer The MMS 5000 autosampler ensures fully automatic de livery of solid and liquid samples. With the appropriate kit for liquid or solid samples, respectively this multimatrix sampler can be converted in minutes without much effort. The combustion system is unaffected and can therefore be brought back into operation within a few minutes. CIC automation. Liquid or solid samples the MMS 5000 autosampler can work with either.

Perfect liquid handling the 920 Absorber Module 06 In the Metrohm CIC System the Combustion Mo dule and ion chromatograph are linked together by the 920 Ab sorber Module. The 920 Absorber Module ensures that the gaseous compounds of the analytes are brought into solution. The professional liquid handling also includes the input of water for combustion, matrix elimination of the hydrogen peroxide (oxidizing agent), and rinsing procedures. Furthermore, an automatic calibration of the analytical sys tem can be obtained from a single multi-ion standard using the Metrohm intelligent Partial Loop Injection Technique (MiPT). Because MiPT allows flexible injection volumes (4-200 µl), a large concentration range can be covered. The following are available for the entire liquid handling: a 10-port valve, a 6-port injection valve and two patented Metrohm 800 Dosino dosing units. The 920 Absorber Module can also be used as a semionline sampler for direct absorption of gas compounds (NH 3, HNO 2, HNO 3, HCl, SO 2 ) from the air. In this way, for example, volatile organic acids (hydrochloric acid, sulfuric acid) can be monitored in process flue gases or in the am bient air at workplaces. 881 Compact IC 920 Absorber Module Combustion Module

07 Easy operation with MagIC Net TM software The complete CIC system is controlled by MagIC Net TM, the proven software for ion chromatography. MagIC Net TM offers great flexibility with regard to configuration, layout and programming. Extensive monitoring and control func tions are available to the user. MagIC Net TM meets all FDA and GLP requirements and is also available in numerous languages. A modern data management system and a powerful report generator round off the package. MagIC Net TM guarantees easy, robust and reliable handling of the system. Thanks to an intelligent operating con cept, the user is able at all times to maintain an overview of all the liquid quantities that are introduced into the absorption solution. Consequently, it is possible to work without an internal standard or other aids.

Ordering information Metrohm markets the complete system, including installation, service and training all from the same supplier. Instruments 2.881.3030 Metrohm Combustion IC The package contains: 2.881.0030 Compact IC pro Anion MCS 2.850.9010 IC Conductivity Detector 2.920.0010 Absorber Module 2.136.0700 Combustion Module 6.6059.241 MagIC Net TM 2.4 Compact 6.1006.310 Metrosep A PCC 1 HC/4.0 Sample changers 2.136.0800 Autosampler MMS 5000 (no sampler head/rack) 6.7302.000 MMS 5000 Kit for Solid Samples 6.7303.000 MMS 5000 Kit for Liquid Samples Columns 6.1031.420 Metrosep A Supp 16-150/4.0 6.1031.500 Metrosep A Supp 16 Guard/4.0 Subject to modifications Layout by Ecknauer+Schoch ASW, printed in Switzerland by Metrohm AG, CH-9100 Herisau 8.108.5025EN 2012-10 www.metrohm.com