L. Seda Mut Neslihan Ötük

Similar documents
Lecture 8: Mass Spectrometry

Lecture 8: Mass Spectrometry

Fundamentals of Mass Spectrometry. Fundamentals of Mass Spectrometry. Learning Objective. Proteomics

TANDEM MASS SPECTROSCOPY

LC-MS Based Metabolomics

(Refer Slide Time 00:09) (Refer Slide Time 00:13)

Università degli Studi di Bari CHIMICA ANALITICA STRUMENTALE

Mass Spectrometry. A truly interdisciplinary and versatile analytical method

Ionization Techniques Part IV

Mass Spectrometry. What is Mass Spectrometry?

Mass Spectrometry. General Principles

Qualitative Organic Analysis CH 351 Mass Spectrometry

( 1+ A) 2 cos2 θ Incident Ion Techniques for Surface Composition Analysis Ion Scattering Spectroscopy (ISS)

Analysis of Polar Metabolites using Mass Spectrometry

Chemistry 311: Topic 3 - Mass Spectrometry

MASS ANALYSER. Mass analysers - separate the ions according to their mass-to-charge ratio. sample. Vacuum pumps

Molecular Mass Spectrometry

Introduction to Mass Spectrometry

Mass Spectrometry for Chemists and Biochemists

Extrel Application Note

CHROMATOGRAPHY AND MASS SPECTROMETER

Secondary Ion Mass Spectroscopy (SIMS)

Temperature-Programmed Desorption

Press Release: The Nobel Prize in Chemistry October 2002 The Royal Swedish Academy of Sciences has decided to award the Nobel Prize in

Mass spectrometry gas phase transfer and instrumentation

Secondary Ion Mass Spectrometry (SIMS)

2. Separate the ions based on their mass to charge (m/e) ratio. 3. Measure the relative abundance of the ions that are produced

for the Novice Mass Spectrometry (^>, John Greaves and John Roboz yc**' CRC Press J Taylor & Francis Group Boca Raton London New York

Temperature-Programmed Desorption. C-874 University of Delaware

Mass Spectrometry and Proteomics - Lecture 2 - Matthias Trost Newcastle University

MS731M: Chemical Analysis of Materials

CHAPTER A2 LASER DESORPTION IONIZATION AND MALDI

Molecular Mass Spectrometry

Mass Spectrometry: Introduction

Secondary Ion Mass Spectrometry (SIMS) Thomas Sky

Introduction to GC/MS

Lecture 15: Introduction to mass spectrometry-i

Mass Spectrometry Course

Mass Spectrometry (MS)

Hiden SIMS Secondary Ion Mass Spectrometers. Analysers for surface, elemental and molecular analysis

LECTURE-11. Hybrid MS Configurations HANDOUT. As discussed in our previous lecture, mass spectrometry is by far the most versatile

Translational Biomarker Core

Secondary ion mass spectrometry (SIMS)

Secondary Ion-Mass Spectroscopy (SIMS)

MS Goals and Applications. MS Goals and Applications

MS Goals and Applications. MS Goals and Applications

Mass Analyzers. Principles of the three most common types magnetic sector, quadrupole and time of flight - will be discussed herein.

Instrumental Analysis. Mass Spectrometry. Lecturer:! Somsak Sirichai

FIB - SIMS. Focussed Ion Beam Secondary Ion Mass Spectrometry.

Types of Analyzers: Quadrupole: mass filter -part1

This is the total charge on an ion divided by the elementary charge (e).

Mass Spectroscopy. Base peak. Molecular Ion peak. The positively charged fragments produced are separated, based on their mass/charge (m/z) ratio. M+.

Mass spectrometry. Talián Csaba Gábor PTE Institute of Biophysics

Mass spectrometry of proteins, peptides and other analytes: principles and principal methods. Matt Renfrow January 11, 2008

The Splendors (and no Miseries) of Mass Spectrometry

Mass Spectrometry. Hyphenated Techniques GC-MS LC-MS and MS-MS

Introduction to the Q Trap LC/MS/MS System

Mass spectrometry and elemental analysis

Application Note GA-301E. MBMS for Preformed Ions. Extrel CMS, 575 Epsilon Drive, Pittsburgh, PA I. SAMPLING A CHEMICAL SOUP

Introduction to SIMS Basic principles Components Techniques Drawbacks Figures of Merit Variations Resources

Secondary ion mass spectrometry (SIMS)

RECOMMENDATIONS FOR NOMENCLATURE OF MASS SPECTROMETRY

Mass Spectrometry in MCAL

The Emergence of Benchtop Tandem Quadrupole Mass Spectrometers as a Routine Tool in Quantitative GC/MS/MS Applications

Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. Molecular weight of polymers. H i

Introduction to LC-MS

Application of Surface Analysis for Root Cause Failure Analysis

20.2 Ion Sources. ions electrospray uses evaporation of a charged liquid stream to transfer high molecular mass compounds into the gas phase as MH n

Chemistry Instrumental Analysis Lecture 34. Chem 4631

CHARACTERIZATION of NANOMATERIALS KHP

Welcome to Organic Chemistry II

MASS SPECTROSCOPY (MS)

MS/MS .LQGVRI0606([SHULPHQWV

Secondary-Ion Mass Spectrometry

Surface and Interface Characterization of Polymer Films

Harris: Quantitative Chemical Analysis, Eight Edition

3.1 Early History of Atomic Theories

LIQUID CHROMATOGRAPHY-MASS SPECTROMETRY (LC/MS) Presented by: Dr. T. Nageswara Rao M.Pharm PhD KTPC

MSE 321 Structural Characterization

MSE 321 Structural Characterization

Lecture 22 Ion Beam Techniques

Overview of NETCHEM MSc & PhD courses: mass spectrometry in EFSC

12. Structure Determination: Mass Spectrometry and Infrared Spectroscopy

Secondary Ion Mass Spectrometry (SIMS) for Surface Analysis

Surface Characterization of Advanced Polymers

ToF-SIMS or XPS? Xinqi Chen Keck-II

Observations Regarding Automated SEM and SIMS Analysis of Minerals. Kristofor Ingeneri. April 22, 2009

History of Mass spectroscopy. Mass Spectroscopy. Introduction... Uses of Mass Spec. Where are Mass Spectrometers Used? Mass Spectroscopy Units

Mass Analyzers. mass measurement accuracy/reproducibility. % of ions allowed through the analyzer. Highest m/z that can be analyzed

TECHNIC A L WORK ING GROUP ITWG GUIDELINE ON SECONDARY ION MASS SPECTROMETRY (SIMS)

Secondaryionmassspectrometry

Mass spectrometry.

Methods of surface analysis

Propose a structure for an alcohol, C4H10O, that has the following

Improvement of bulk analysis of environmental samples by using a multiple collector ICP-MS

Research Equipment in the UCA Chemistry Department

Auxiliary Techniques Soft ionization methods

BST 226 Statistical Methods for Bioinformatics David M. Rocke. January 22, 2014 BST 226 Statistical Methods for Bioinformatics 1

Introduction to Mass Spectrometry (MS)

Interpretation of Organic Spectra. Chem 4361/8361

Transcription:

L. Seda Mut 20970802 Neslihan Ötük 20622809 Beytepe Ankara 12.04.2012

Outline Historical Background of MS and SIMS What is MS and SIMS? Working Principle of MS and SIMS Instrumental Structures What properties can be measured with MS, SIMS? Advantages and Disadvantages

Historical background History of MS JJ Thomson built MS prototype to measure m/z of electron, awarded Nobel Prize in 1906 MS concept first put into practice by Francis Aston, a physicist working in Cambridge England in 1919 and awarded Nobel Prize in 1922 1948-52 - Time of Flight (TOF) mass analyzers introduced 1955 - Quadrupole ion filters introduced by W. Paul, also invents the ion trap in 1983 (wins 1989 Nobel Prize) 1968 - Tandem mass spectrometer appears Mass spectrometers are now one of the MOST POWERFUL ANALYTIC TOOLS IN CHEMISTRY

History of SIMS In 1910 British physicistj. J. Thomson observed a release of positive ions and neutral atoms from a solid surface induced by ion bombardment. Improved vacuum pump technology in the 1940s enabled the first prototype experiments on SIMS at the University of Vienna, Austria In the early 1960s two SIMS instruments were developed. One was an American project for analyzing moon rocks the other at the University of Paris. These first instruments were based on a magnetic double focusing sector field mass spectrometer and used argon for the primary beam ions. Recent developments are focusing on novel primary ion species likec60or ionized clusters of gold and bismuth

Mass Spectrometry Mass spectrometry (MS) is an analytical technique that measures the mass-to-charge ratio of charged particles. Mass spectrometers have been used in both qualitative and quantitative ways to determine the elemental composition and structure of specific compounds. Analytical method to measure the molecular or atomic weight of samples.

Mass Spectrometry is Used for Determining the chemical and structural information about molecules Idenfication of unknown compounds Quantification of known compounds Determining the relative abundance of the isotopes and to measure their exact masses Measuring molecular mass of a sample

MS applications Geological: Oil composition Pharmaceutical:Drug mechanisms, pharmacokinetics, drug discovery Space applications: analysis the composition of plasmas and solar wind. Clinical:Drug testing, hemoglobin analysis Environmental:Water quality, food contamination Biotechnology:The analysis of proteins, peptides etc. Vacuums: In high-vacuum systems, mass spectrometers are used to measure for any residual gases.

Mass Spectrometer MS instruments consist of three modules: Mass spectrometer components (http://www.emsl.pnl.gov/capabilities/viewinstrument.jsp?id=34006)

How a mass spectrometer works? An ion source, converts gas phase sample molecules --> ions A mass analyzer; sorts the ions by their masses by applying electromagnetic fields A detector; measures the value of an indicator quantity and thus provides data for calculating the abundances of each ion present

Mass Spectrometry Principles Sample + _ Ionizer Mass Analyzer Detector Mass spectrometry illustration (http://www.lamondlab.com/msresource/lcms/massspectrometry/massspectrometry.php)

Mass Spectrometer Create ions Separate ions Detect ions Ionization method MALDI Electrospray (Proteins must be charged and dry) Mass analyzer MALDI-TOF Triple Quadrapole MALDI-QqTOF QqTOF Mass spectrum Database analysis

Mass spectrometer (http://www.chemguide.co.uk/analysis/masspec/howitworks.html)

Data analysis of MS Many mass spectrometers work in either negative ion mode or positive ion mode. It is very important to know whether the observed ions are negatively or positively charged. This is often important in determining the neutral mass but it also indicates something about the nature of the molecules. Different types of ion source result in different arrays of fragments produced from the original molecules. An electron ionization source produces many fragments and mostly single-charged (1-) radicals (odd number of electrons), whereas an electrospray source usually produces non-radical quasimolecular ions that are frequently multiply charged

An example to a mass spectrum (http://en.wikipedia.org/wiki/mass_spectrometry#chro matographic_techniques_combined_with_mass_spectro metry) Results can also depend heavily on how the sample was prepared and how it was run/introduced

Examples of mass spec data output Ex: B You can scan in B or V to sweep masses across a single detector. OR You can put different masses into multiple cups without changing B or V.

Ionizers (http://www.asms.org/whatisms/p12.html)

http://www.authorstream.com/presentation/sr eeramdileep-584348-mass-spectroscopy/

http://www.authorstream.com/presentation/sreeramdileep- 584348-mass-spectroscopy/

http://www.authorstream.com/presentation/sreeramdileep- 584348-mass-spectroscopy/

http://www.authorstream.com/presentation/ sreeramdileep-584348-mass-spectroscopy/

Advantages of Mass Spectroscopy Providesmolecular weightsof peptides and proteins with highaccuracy (0.1-0.01%) Highlysensitive Sample puritynot important Can be coupledwith on-lineseparationmethodssuch as HPLC and capillaryelectrophoresisfor the analysis of mixtures

Disadvantages of Mass Spectroscopy Noncovalentcomplexesare oftendisrupted Cannotdistinguishstereoisomers Expensiveinstrumentation Fewfor proteins and peptides, as purityand sample requirementsare not restrictive(fmolpmolquantitiescan be used) Otherbiopolymers(nucleicacid, carbohydrates) are moredifficultto analyze

SIMS Secondary ion mass spectrometry (SIMS) is based on the observation that charged particles (Secondary Ions) are ejected from a sample surface when bombarded by a primary beam of heavy particles.

Secondary ion mass spectroscopy Basic Overview

What properties can be measured/tested with SIMS? -Secondary ion mass spectrometry(sims) is a technique used inmaterials science and surface science to analyze the composition of solid surfaces andthin films by sputtering the surface of the specimen with a focused primaryion beamand collecting and analyzing ejected secondary ions. -These secondary ions are measured with a mass spectrometerto determine the elemental, isotopic, or molecular composition of the surface.

SECONDARY ION SPUTTERING http://www.geos.ed.ac.uk/facilities/ionprobe/sims4.pdf

Advantages of SIMS The elements from H to U may be detected. Most elements may be detected down to concentrations of 1ppm or 1ppb. Isotopic ratios may be measured, normally to a precision of 0.5 to 0.05%. Two dimensional ion images may be acquired. A secondary ion leaves the surface at a point close to its original location. This enables localised analysis of the sample to be undertaken and is the cornerstone of ion imaging.

The volume of material sputtered is small. Using a highenergy and high primary beam densities (dynamic SIMS) a volume of a 100 to 1000 μm3 is analysed. In contrast, using lowenergy and low primary beam densities (static SIMS) the material sputtered is exceedingly small, with surface mono-layers lasting hours or days. Three dimensional ion images may be acquired by scanning (rastering) the primary beam and detecting the ion signal as the sample is gradually eroded. Little or no sample preparation may be needed.

Limitations of SIMS The material sputtered from the sample surface consists not only of mono-atomic ions but molecular species that in places can dominate the mass spectrum, making analysis of some elements impossible. The sputtering process is poorly understood. No quantitative model currently exists that can accurately predict the secondary ionisation process. In order to obtain quantitative information a suitable standard has to be used and empirical corrections applied. The sensitivity of an element is strongly dependent on the composition of the matrix and the type of primary beam used. Standards should, therefore, be close to the composition of the unknown. This is particularity true for isotopic analysis. Samples must be compatible with an ultra high vacuum.

TYPICAL APPLICATIONS of SIMS Analyzing biological materials The investigation of possible links between glass failure and polishing residue in optical components used in powerful lasers,

References http://www.authorstream.com/presentation/asguest114953-1199123-mass-spectrometry/ http://www.ehow.com/list_7150856_uses-mass-spectrometer.html http://www2.chemistry.msu.edu/faculty/reusch/virttxtjml/spectrpy/massspec/masspe c1.htm http://www.chemguide.co.uk/analysis/masspec/howitworks.html http://www.emsl.pnl.gov/capabilities/viewinstrument.jsp?id=34006 http://en.wikipedia.org/wiki/secondary_ion_mass_spectrometry http://www.lamondlab.com/msresource/lcms/massspectrometry/massspectrometry.ph p http://www.chemguide.co.uk/analysis/masspec/howitworks.html http://en.wikipedia.org/wiki/mass_spectrometry#chromatographic_techniques_combine d_with_mass_spectrometry http://www.asms.org/whatisms/p12.html http://www.authorstream.com/presentation/sreeramdileep-584348-mass-spectroscopy/