Neutron imaging with a Micromegas detector

Similar documents
A new detector for neutron beam monitoring

PoS(FNDA2006)010 FAST NEUTRON DETECTORS BASED ON MICROMEGAS TECHNOLOGY. S. Andriamonje * I. Giomataris and J. Pancin

Discharge studies in Micromegas detectors in low energy hadron beams

ATLAS New Small Wheel Phase I Upgrade: Detector and Electronics Performance Analysis

Detecting low energy recoils with Micromegas

New neutron detector based on Micromegas technology for ADS projects

Precision Calibration of Large Area Micromegas Detectors Using Cosmic Muons

Track Resolution Measurements for a Time Projection Chamber with Gas Electron Multiplier Readout

Measurement of the n_tof beam profile in the second experimental area (EAR2) using a silicon detector

Performance of high pressure Xe/TMA in GEMs for neutron and X-ray detection

Simulating the Charge Dispersion Phenomena in Micro Pattern Gas Detectors with a Resistive Anode

GEM at CERN. Leszek Ropelewski CERN PH-DT2 DT2-ST & TOTEM

Breakdown limit studies in high-rate gaseous detectors

& SUN ZhiJia 1;2. Abstract

PoS(EPS-HEP2015)232. Performance of a 1 m 2 Micromegas Detector Using Argon and Neon based Drift Gases

Nuclear Instruments and Methods in Physics Research A

GEM-based photon detector for RICH applications

Neutron capture and fission reactions on. sections, -ratios and prompt -ray emission from fission. 1 Introduction and Motivation

arxiv:physics/ v1 [physics.ins-det] 2 Aug 2000

ACTAR TPC: an active target and time projection chamber for nuclear physics

Electron transparency, ion transparency and ion feedback of a 3M GEM

GEM: A new concept for electron amplification in gas detectors

Angular resolution of the gaseous micro-pixel detector Gossip

Determination of the boron content in polyethylene samples using the reactor Orphée

A fast triple GEM detector for high-rate charged-particle triggering

A Complete Simulation of a Triple-GEM Detector

Micro Pixel Chamber with resistive electrodes for spark reduction

Position sensitive detection of thermal neutrons with solid state detectors (Gd Si planar detectors)

MONTE-CARLO SIMULATIONS OF TIME- RESOLVED, OPTICAL READOUT DETECTOR for PULSED, FAST-NEUTRON TRANSMISSION SPECTROSCOPY (PFNTS)

Simulation of GEM-TPC Prototype for the Super-FRS Beam Diagnostics System at FAIR

Performance of a triple-gem detector for high-rate particle triggering

Advances in the Micro-Hole & Strip Plate gaseous detector

Spatial resolution measurement of Triple-GEM detector and diffraction imaging test at synchrotron radiation

PHOTOELECTRON COLLECTION EFFICIENCY AT HIGH PRESSURE FOR A GAMMA DETECTOR ENVISAGING MEDICAL IMAGING

Investigation of GEM space point resolution for a TPC tracker

Fission Fragment characterization with FALSTAFF at NFS

MICROMEGAS Signal: Numerical Simulation Based on Neon-Isobutane and Neon-DME

CCD readout of GEM-based neutron detectors

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

The Compact Muon Solenoid Experiment. Conference Report. Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

Recent developments on Micro-Pattern Gaseous Detectors

Detectors in Nuclear and High Energy Physics. RHIG summer student meeting June 2014

This paper should be understood as an extended version of a talk given at the

ACTAR TPC: an active target and time projection chamber for nuclear physics. 17/09/2015 T. Roger COMEX 5 1

A complete simulation of a triple-gem detector

Digital imaging of charged particle track structures with a low-pressure optical time projection chamber

Particle Energy Loss in Matter

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

An ultra-low-background detector for axion searches

Micro-pattern gaseous detectors

Development of New MicroStrip Gas Chambers for X-ray Applications

Neutron Structure Functions and a Radial Time Projection Chamber

TPC-like analysis for thermal neutron detection using a GEMdetector

NEW DEVELOPMENTS IN GASEOUS DETECTORS. Fabio Sauli. CERN, Geneva, Switzerland

arxiv:physics/ v2 27 Mar 2001

High Spatial Resolution in thermal Neutron Detection: from CASCADE to BASTARD. Markus Köhli. DPG Frühjahrstagung Münster

Background optimization for a new spherical gas detector for very light WIMP detection

A Triple-GEM Telescope for the TOTEM Experiment

EEE4106Z Radiation Interactions & Detection

Micromegas detectors & the Great Pyramid. S. Procureur

Flux and neutron spectrum measurements in fast neutron irradiation experiments

A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC

Neutrons for Science (NFS) at SPIRAL-2

COMMISSIONING TESTS OF THE NEW NEUTRON RADIOGRAPHY FACILITY AT THE LVR-15 REACTOR ABSTRACT

4.1 Phenomenology of particle detection in a gas

Spatial resolution of a MPGD TPC using the charge dispersion signal

TitleDevelopment of an MeV gamma-ray ima. works must be obtained from the IEE

Geometry Survey of the Time-of-Flight Neutron-Elastic Scattering (Antonella) Experiment

Millimetre wave attenuation of prototype diagnostic components for the ITER bolometers

Rate Dependency Study on Gas Electron Multiplier Gain

Test-bench for the Characterization of MicroMegas Modules for the T2K ND280 TPC

First Measurement of a 127 kev Neutron Field with a µ-tpc Spectrometer

SUMMER STUDENT PROGRAM

Study of GEM-like detectors with resistive electrodes for RICH applications

Neutrons For Science (NFS) at SPIRAL-2 (Part II: pulsed neutron beam)

Digital Hadron Calorimetry for the Linear Collider using GEM Technology

Bolometry. H. Kroegler Assciazione Euratom-ENEA sulla Fusione, Frascati (Italy)

Alpha-Energies of different sources with Multi Channel Analyzer

Development of a Radiation Hard CMOS Monolithic Pixel Sensor

What detectors measure

arxiv: v1 [physics.ins-det] 28 Mar 2016

Study of the HARPO TPC for a high angular resolution g-ray polarimeter in the MeV-GeV energy range. David Attié (CEA/Irfu)

PERFORMANCE OF WIRE POSITION SENSORS IN A RADIATION ENVIRONMENT. CERN, Geneva, Switzerland

Evaluation and reduction of ion back-flow in multi-gem detectors

Bulk Micromegas detectors for large TPC applications

Characterization of 3D thermal neutron semiconductor detectors

Performance of triple GEM tracking detectors in the COMPASS experiment

arxiv: v1 [physics.ins-det] 7 Dec 2018

A proposal to study gas gain fluctuations in Micromegas detectors

arxiv: v1 [physics.ins-det] 29 Jun 2011

Status and Challenges of CEPC Time Projection Chamber Detector. Huirong On behalf of CEPC Tracking Subgroup

Photon Instrumentation. First Mexican Particle Accelerator School Guanajuato Oct 6, 2011

The ATLAS Liquid Argon Calorimeter: Construction, Integration, Commissioning Ph. Schwemling on behalf of the ATLAS LAr Group

arxiv: v1 [physics.ins-det] 10 May 2011

The CONNIE experiment

Time-of-Flight PET using Cherenkov Photons Produced in PbF 2

arxiv: v3 [physics.ins-det] 25 Oct 2016

PANDA Muon System Prototype

Performance studies of MicroMegas for the ATLAS experiment

Gas Electron Multiplier detectors with high reliability and stability. Abstract. Introduction

Transcription:

Neutron imaging with a Micromegas detector S Andriamonje A, V. Dangendorf B, I. Espagnon C, H. Friedrich B, A. Giganon A, I. Giomataris A, F. Jeanneau C *, R. Junca C, A. Menelle D, J. Pancin A, A. Pluquet C, L. R. Rodríguez E, M. Voytchev C A DSM/DAPNIA, CEA-Saclay, 91191 Gif sur Yvette Cedex, France B PTB, Braunschweig, Germany C DRT/DeTeCS, CEA-Saclay, 91191 Gif sur Yvette Cedex, France D DSM/DRECAM/LLB, CEA-Saclay, 91191 Gif sur Yvette Cedex, France E Dpto de Física, Universidad de Burgos, Avda. Cantabria s/n., 09006 Burgos, Spain Abstract Due to its performances for neutron detection, the micropattern gaseous detector Micromegas is designed for neutron imaging. In this paper will be presented new results obtained with thermal neutrons near Orphée reactor at CEA Saclay. The goal of studies with a bi-dimensional detector was to tune different parameters in order to achieve the best spatial resolution which is around 160 µm (defined as the standard deviation) in double amplification mode and 180 µm in classical mode. Several D imaging tests have been carried out and an example, which shows different problems inherent in the substrate manufacturing, will be presented. Then, a tomographic section of a multi-wires cable, achieved with a one-dimensional Micromegas, will be presented. The high number of pillars sustaining the micromesh has lead to local inefficiencies, disturbing the tomographic reconstruction, but this result, the first tomography carried out with this kind of detector, is very encouraging. I. INTRODUCTION ICROMEGAS (MICRO-MEsh GAseous Structure) is a gaseous detector developed in Saclay since 1996 [1] and initially designed for fundamental research purposes, specially for detection and localization of charged particles. Several studies have already been performed with this detector [-5], demonstrating its capacity to work at high particles flux with a good spatial resolution. In this study, the performances of this detector are evaluated for applications in thermal neutron imaging. New results obtained near Orphée facility in Saclay, with a D prototype, will be presented. Previous investigations gave promising results in terms of spatial resolution which will introduce a study about D imaging and the problems met with the D readout plane. A second part will be dedicated to a tomographic section obtained with a Micromegas 1D prototype which have previously achieve a spatial resolution around 60 µm [5]. M II. THE MICROMEGAS DETECTOR A. Detector principle When charged particles travel through the gas, electrons are produced between the drift electrode and the micromesh by ionization process. Then they drift towards the micromesh under the action of the electric field (~1 kv/cm) applied in the conversion gap (0.7 mm). After the micromesh, they are multiplied in the narrow amplification gap (50 or 100 µm) see figure 1 and the subsequent electron avalanche induces a current on the anode strips. Fig. 1. Micromegas principle for neutron detection. However, a neutron/charged particle converter is necessary to produce ionization. The conversion reactions used are neutron capture on 6 Li (or 6 LiF) and 10 B (respectively with cross section of 940 and 3840 barns), deposited on the drift electrode: 6 4 3 3 Li + n He(.05MeV ) + 1H (.73MeV ) Q = 4.78 MeV 10 4 7 5 B + n He(1.47MeV) + 3Li(0.83MeV) Q =.7 MeV * Corresponding author: F. Jeanneau; tel: +33-(0)1-69089348; fax: +33-(0)1-69089348; email address: fabien.jeanneau@cea.fr Manuscript received October 6, 004. This work was supported in part by the Conseil Régional d Ile de France. Since the incoming neutron energy is negligible compared to the reaction Q value, the two reactions products (alpha, triton or 7 Li) are emitted in opposite directions. The optimal

thickness of the converter (table 1) has been estimated by simulation in each cases taking into account the exit of the products from the converter (see figure for the 6 Li converter). TABLE I DIFFERENT CONVERTERS PARAMETERS Type 6 Li (1) 6 LiF () 10 B (3) Thickness [µm] 100 / 4 0.8 Efficiency (%) 18 1.1 / 5.9 3.6 Thickness optimal [µm] 130 33 3.4 Efficiency max (%) 18 6.4 7.8 Evaporated in: (1) Physikalisch Technische Bundesanstalt (PTB), Braunschweig, Germany () University of Burgos, Spain (3) CERN, Geneva, Switzerland III. D IMAGING STUDY Tests and measurements have been carried out near Orphée reactor in Saclay. The detector has been irradiated in a 0.05 ev neutron beam of 10 6 n.cm -.s -1, after two collimators (B 4 C and Cd) defining a 10 10 mm² working area. A. Prototype description The D readout, which is the main part of this D prototype, is made on a coppered Kapton where are etched the strips with a pitch of 300 µm. Strips consist in hexagonal pixels connected like on the figure 3, on the upper face in one dimension and on the other face by metallic holes in the second dimension. Fig. 3. Plan of the D readout (pitch=300µm) Fig.. 6 Li conversion efficiency Conversion products are emitted isotropically so, in order to minimize the strip multiplicity for large angles, the conversion gap is reduced to few hundreds of micrometers; amplification gap is 50 µm high. Two working modes can be used: normal mode, when amplification takes place in the lower gap, or pre-amplification mode, when the electric field applied in the conversion gap is high enough to amplify the signal so that the global detector gain is a contribution from the two stages. B. Electronics and data acquisition system For each event, the spatial distribution of the deposited charge on the 384 strips is collected by 4 GASSIPLEX [6] boards (96 channels per board) performing charge preamplification and multiplexing. A VME electronics, composed of a sequencer (CAEN model V551) and CRAMs (CAEN model V550-10 bits), is used to command the GASSIPLEX and store their signals, and the acquisition system is triggered by the amplified micromesh signal. Once all the ADC values have been stored in the CRAMs, data are transferred on a PC via VME-MXI- card (National Instruments). The whole system is managed by a LabView software allowing a pedestal suppression, in order to acquire data with a higher frequency (around.5 khz). B. Data analysis Once the normal distribution of the electronic noise is registered for each channel (obtained without neutron beam), the mean value of the distribution gives the pedestal value, and the standard deviation will be used to discriminate the signal from the noise. These values are registered in the acquisition system so that it will record the channels with an ADC value larger than the pedestal value plus typically 3 rms. Empty channels are then suppressed before registration, minimizing the data flow and allowing the acquisition system to run at higher frequency. The data file contains the event number and the list of the fired strips with their ADC value. Every contiguous strips with a signal is stored in a cluster by a C++ code which corrects eventually dead strips by the mean value of their neighbours. The main cluster is the one which contains the higher charge strip and several parameters are needed from this cluster: charge and number of the maximum strip, total number of strips, total charge (sum of all ADC values) and the barycentre of the cluster charge, which is related to the incident neutron position. Using these parameters it is possible to reconstruct the incident neutron beam on the plane of strips, and to improve the spatial resolution and so the image quality, by applying cuts on the cluster charge or multiplicity. The selection criteria are: - at least one cluster in X AND Y

- cluster multiplicity: in order to limit the error on the barycentre calculation, only low multiplicity (, 3 or 4 strips) are considered - charge: no saturation strips C. Spatial resolution estimation In order to determine the spatial resolution of the detector, an image with neutrons of a calibrated object is used, here a hole ( 0.6 mm) in a Cadmium foil (thickness 0.8 mm). The image is fitted by the convolution of a square function and a Gaussian function: T ( x, y) a + = p + A Erf ( ) ( ) x µ + y µ a ( x µ ) + ( y µ ) x σ y + Erf where p is the noise level, A is a constant, a is the half width of the hole, µ x and µ y are the centers of the hole and σ is the gaussian r.m.s. and gives the spatial resolution value. x σ y Fig. 6. 1D spatial resolution for different cluster multiplicities. The optimal resolution is around 160 µm and is obtained for a multiplicity equals to, as it is represented on the figure 7. D. Results Figure 4 and 5 show the image and profile of 0.6 mm holes. The plane of strips was containing a lot of dead strips and the spatial resolution study was carried out using a small working zone (10 10 mm² centered on the images of the holes). Fig. 7. D spatial resolution for multiplicity of Fig. 4. Images of 0.6 mm holes obtained on the whole surface of the detector Fig. 5. Closer detail and profiles of the holes in the working zone Events selection is quite hard to obtain an optimal spatial resolution, so the number of events conserved after selection, and the global efficiency of the detector, is decreasing from a resolution around 300 µm, with 90 % of good events, to a resolution around 160 µm, with only 15 % of events kept. Two different working modes have been studied as it is said before. Better results, in terms of spatial resolution, are obtained in pre-amplification mode, and that can be explained by a better neutron position reconstruction due to the shape of the clusters (see figure 8). In normal mode, electrons created along the way of the particle in the conversion gap will lead to a uniform signal. On the other hand, in pre-amplification mode, electrons created at the beginning of the conversion gap, and corresponding exactly to the neutron position, have a bigger contribution to the signal. The cluster barycentre is then shifted towards the particle entry point, and then will affect the spatial resolution. Following results have been calculated with the hole presenting less statistics because of the dead strip passing through the other one (see figure 5). Figure 6 shows the 1D (Y) resolution variations as a function of event selection (cluster multiplicity).

IV. TOMOGRAPHY WITH A 1D MICROMEGAS DETECTOR Fig. 8. Shape of the charge cluster in pre-amplification and normal mode Finally, the D spatial resolution is about 180 µm in normal mode and 160 µm in pre-amplification mode with an acceptation rate of 15 %. A new prototype has been mounted with a new plane of strips in order to perform an image of a real object: a Gadolinium foil of 100 µm thick on which have been etched the letters CEA. Figure 9 shows the scheme of the etching and the image obtained in neutron beam. The three letters of the object are well reconstructed, and the dimensions respected, but the image quality is not very good because of inefficiency area. After a carefully electric test of the plane of strips, some cross-talk between the strips of the directions has been found out, causing significant signal losses on some strips. Cluster barycentre is then affected by this effect which degrades spatial resolution and response homogeneity. Nevertheless these results are very encouraging and a special attention is carried on the manufacturing of the new plane of strips in order to improve the D performances of this detector. Fig. 9. Scheme of the gadolinium foil (100 µm) etching and image obtained with the detector. A. Setup description Measurements for tomography have been performed in march 004 at GKSS in Geesthacht, Germany, near the GeNF (Geesthacht Neutron Facility) reactor which is dedicated to neutron spectroscopy with 15 experimental areas, like POLDI area (POLarised DIffractometer) delivering a thermal neutron flux of 8.10 4 n.cm -.s -1 with an optimal L/D ratio around 000. The tomographic section of a multi-wires cable ( 6 mm), containing 1 wires ( 0.5 mm each), has been achieved using a 1D Micromegas (same principle than before but with a 1D readout plane of strips). Between the object and the detector is located a 1 mm wide slit in order to reduce scattered neutrons (see figure 10). Fig. 10. Schematic view of the tomographic setup (not on scale) A remote control motor hold and rotate the object between each projections. B. Tomography test results The total number of projections is 81, on 360, with a counting rate around 00 neutrons per seconds and per projection. The time allocated for each projections is about 1000 secondes and so a tomographic section can be performed in about 6 hours. Because of a poor statistics, it was not possible to apply the event selection necessary to reach the optimal resolution (keeping only the low multiplicity events). Cuts in our case are: a multiplicity below 1 strips and no events with a too high deposited charge per strip, in order to select the event perpendicular to the direction of the strips. These cuts ensure a spatial resolution around 100 µm, calculated with the image of a slit of 500 µm wide parallel to the strips. An image of the beam with no object I 0 (x) is needed for the tomographic reconstruction to monitor the beam and the defects of the detector. Each projection I i (x) is normalized with the empty run, by adjusting the number of events on the edges of the object, so that the beam or acquisition time variations are corrected. Then the ratio Log(I 0 (x)/i i (x)) gives an evaluation of the integral of the neutron attenuation coefficient in the projection direction, as it is represented on figure 11 for the projection at 0. Some structures due to the wires in the cable are visible but the normalization is not enough efficient

to remove totally the influence of the pillars sustaining the micromesh. Fig. 11. Projection at 0 after normalization. The reconstruction is represented on the figure 1 (bottom) with the sinogram corresponding to the piling of the projections on the left. Some wires and the sheath are well reconstructed but the image center is quite blurred. As a comparison, the section of the same object obtained with image plates is better (see figure 1 right). The main reason to explain this difference of quality is certainly the high number of pillars on the plane of strips, deposited every 0.6 mm, which could be decreased by a factor 4. Local inefficiencies due to pillars are interpreted as concentric circles, degrading the spatial resolution, specially near the rotation center. Another reason is the lack of statistics and the fact that the optimal set of cuts cannot be applied to achieve the best spatial resolution, but this could be improved using a higher neutron flux. V. CONCLUSION The D prototype equipped with its acquisition electronics worked well during the experiments near Orphée reactor. A D spatial resolution of around 160 µm (in terms of standard deviation) has been reached in pre-amplification mode and around 180 µm in normal mode, with an acceptation level of 15 % (multiplicity equals to in X and in Y). Taking into account the dead strips, these results are very encouraging. An image has been performed with a new plane of strips and has permitted to detect cross-talk between the directions of the plane of strips. Manufacturing process is optimized to avoid this kind of defects which degrades the spatial resolution and leads to local inefficiencies, some strips loosing the main part of their signal. Further measurements are necessary. A tomographic section has been carried out with a 1D prototype near the GKSS reactor in Geesthacht. The image of a multi-wires cable obtained after reconstruction do not present the same quality than the one obtained with image plate. The main reason is the high number of pillars on the plane of strips, leading to local inefficiencies and then to artefacts in the reconstruction process. Moreover, it was not possible to apply the optimal set of cuts due to the lack of statistics. The results obtained are very encouraging despite the technical problems encountered. Decreasing the number of pillars and using a more high neutron flux could be simple solutions to perform new measurements and conclude about the relevance of this kind of devices for neutron imaging. VI. REFERENCES [1] I. Giomataris, Ph. Rebourgeard, J.-P. Robert, and G. Charpak, "Micromegas: a high-granularity position-sensitive gaseous detector for high particle-flux environments," Nuclear Instruments and Methods in Physics Research A 376 (1996) 9-35. [] J. Pancin et al., "Measurement of the n-tof beam profile with a Micromegas detector," Nuclear Instruments and Methods in Physics Research A 54 (004) 10-114. [3] J. Derré, I. Giomataris, Ph. Rebourgeard, H. Zaccone, J.-P. Perroud, and G. Charpak, "Fast signals and single electron detection with a Micromegas photodetector," Nuclear Instruments and Methods in Physics Research A 449 (000) 314-3. [4] J. Derré, I. Giomataris, "Recent experimental results with Micromegas," Nuclear Instruments and Methods in Physics Research A 477 (00) 3-8. [5] S. Andriamonje et al., "Comparison between image plate and Micromegas detector for thermal neutron tomography," Advances in Neutron Scattering Instrumentation, Proceedings of SPIE, Volume 4785 (00). [6] J.-C. Santiard et al., CERN-ECP/94-17. Fig. 1. (left) Sinogram of the 81 projections, (right) tomographic section using image plates, (bottom) tomographic section using the Micromegas detector.